Water quality monitoring by nanostructured films in a sensing unit system
Presented here is a study about the capability of a sensing unit to detect changes in river water quality. In order to determine its accuracy, water quality was monitored at 11 points along the Veado River in Presidente Prudente, Brazil. To have a basis for comparison, a water quality index (WQI) wa...
Gespeichert in:
Veröffentlicht in: | Desalination and water treatment 2012-02, Vol.40 (1-3), p.209-214 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 214 |
---|---|
container_issue | 1-3 |
container_start_page | 209 |
container_title | Desalination and water treatment |
container_volume | 40 |
creator | BARBOSA CAJUELA, Kássia GUENKA DAUER, Paaron CAMARGO ROSA, Miria CUBA TERAN, Francisco Javier ALBERTO GIACOMETTI, Jose |
description | Presented here is a study about the capability of a sensing unit to detect changes in river water quality. In order to determine its accuracy, water quality was monitored at 11 points along the Veado River in Presidente Prudente, Brazil. To have a basis for comparison, a water quality index (WQI) was developed following methods previously applied in different watersheds. Results showed an accurate relationship between WQI and electric impedance readings detected by the sensing unit. Principal components analysis (PCA) was used to derive results in a form that can be correlated with WQI calculated for each sample point, which showed the potential application of this device. |
doi_str_mv | 10.1080/19443994.2012.671172 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1017971399</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1934060552</sourcerecordid><originalsourceid>FETCH-LOGICAL-c276t-f4461c4770de6b106a3743622057e260e32be5b978a76e81b7f8ccd952b4ffed3</originalsourceid><addsrcrecordid>eNpdkE1LxDAQhoMouKz7DzwERPDSNUnz0Rxl8WNhwYvisaRpIlnadDfTHvrvbVndg3OZYXjel5kXoVtK1pQU5JFqznOt-ZoRytZSUarYBVrM6yzXhbw8z5pfoxXAnkwluBKcLdD2y_Qu4eNgmtCPuO1i6LsU4jeuRhxN7KBPg-2H5GrsQ9MCDhEbDC7CDA0TjmGE3rU36MqbBtzqty_R58vzx-Yt272_bjdPu8wyJfvMcy6p5UqR2smKEmlyxXPJGBHKMUlczionKq0Ko6QraKV8YW2tBau4967Ol-jh5HtI3XFw0JdtAOuaxkTXDVBSQpVWdHp3Qu_-oftuSHG6rqQ650QSIdhE8RNlUweQnC8PKbQmjZNVOUdc_kVczhGXp4gn2f2vuQFrGp9MtAHOWiZUIYTS-Q8Ge3p-</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1934060552</pqid></control><display><type>article</type><title>Water quality monitoring by nanostructured films in a sensing unit system</title><source>Alma/SFX Local Collection</source><creator>BARBOSA CAJUELA, Kássia ; GUENKA DAUER, Paaron ; CAMARGO ROSA, Miria ; CUBA TERAN, Francisco Javier ; ALBERTO GIACOMETTI, Jose</creator><creatorcontrib>BARBOSA CAJUELA, Kássia ; GUENKA DAUER, Paaron ; CAMARGO ROSA, Miria ; CUBA TERAN, Francisco Javier ; ALBERTO GIACOMETTI, Jose</creatorcontrib><description>Presented here is a study about the capability of a sensing unit to detect changes in river water quality. In order to determine its accuracy, water quality was monitored at 11 points along the Veado River in Presidente Prudente, Brazil. To have a basis for comparison, a water quality index (WQI) was developed following methods previously applied in different watersheds. Results showed an accurate relationship between WQI and electric impedance readings detected by the sensing unit. Principal components analysis (PCA) was used to derive results in a form that can be correlated with WQI calculated for each sample point, which showed the potential application of this device.</description><identifier>ISSN: 1944-3994</identifier><identifier>EISSN: 1944-3986</identifier><identifier>DOI: 10.1080/19443994.2012.671172</identifier><language>eng</language><publisher>L'Aquila: Desalination Publications</publisher><subject>Applied sciences ; Brazil ; Change detection ; Components ; Detection ; Electric impedance ; Electric potential ; Environmental monitoring ; Exact sciences and technology ; Freshwater ; Mathematical analysis ; Monitoring ; Nanostructure ; Pollution ; Principal components analysis ; River water ; Rivers ; Water monitoring ; Water quality ; Water quality management ; Water treatment and pollution ; Watersheds</subject><ispartof>Desalination and water treatment, 2012-02, Vol.40 (1-3), p.209-214</ispartof><rights>2015 INIST-CNRS</rights><rights>Copyright Desalination Publications</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=25785579$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>BARBOSA CAJUELA, Kássia</creatorcontrib><creatorcontrib>GUENKA DAUER, Paaron</creatorcontrib><creatorcontrib>CAMARGO ROSA, Miria</creatorcontrib><creatorcontrib>CUBA TERAN, Francisco Javier</creatorcontrib><creatorcontrib>ALBERTO GIACOMETTI, Jose</creatorcontrib><title>Water quality monitoring by nanostructured films in a sensing unit system</title><title>Desalination and water treatment</title><description>Presented here is a study about the capability of a sensing unit to detect changes in river water quality. In order to determine its accuracy, water quality was monitored at 11 points along the Veado River in Presidente Prudente, Brazil. To have a basis for comparison, a water quality index (WQI) was developed following methods previously applied in different watersheds. Results showed an accurate relationship between WQI and electric impedance readings detected by the sensing unit. Principal components analysis (PCA) was used to derive results in a form that can be correlated with WQI calculated for each sample point, which showed the potential application of this device.</description><subject>Applied sciences</subject><subject>Brazil</subject><subject>Change detection</subject><subject>Components</subject><subject>Detection</subject><subject>Electric impedance</subject><subject>Electric potential</subject><subject>Environmental monitoring</subject><subject>Exact sciences and technology</subject><subject>Freshwater</subject><subject>Mathematical analysis</subject><subject>Monitoring</subject><subject>Nanostructure</subject><subject>Pollution</subject><subject>Principal components analysis</subject><subject>River water</subject><subject>Rivers</subject><subject>Water monitoring</subject><subject>Water quality</subject><subject>Water quality management</subject><subject>Water treatment and pollution</subject><subject>Watersheds</subject><issn>1944-3994</issn><issn>1944-3986</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNpdkE1LxDAQhoMouKz7DzwERPDSNUnz0Rxl8WNhwYvisaRpIlnadDfTHvrvbVndg3OZYXjel5kXoVtK1pQU5JFqznOt-ZoRytZSUarYBVrM6yzXhbw8z5pfoxXAnkwluBKcLdD2y_Qu4eNgmtCPuO1i6LsU4jeuRhxN7KBPg-2H5GrsQ9MCDhEbDC7CDA0TjmGE3rU36MqbBtzqty_R58vzx-Yt272_bjdPu8wyJfvMcy6p5UqR2smKEmlyxXPJGBHKMUlczionKq0Ko6QraKV8YW2tBau4967Ol-jh5HtI3XFw0JdtAOuaxkTXDVBSQpVWdHp3Qu_-oftuSHG6rqQ650QSIdhE8RNlUweQnC8PKbQmjZNVOUdc_kVczhGXp4gn2f2vuQFrGp9MtAHOWiZUIYTS-Q8Ge3p-</recordid><startdate>20120201</startdate><enddate>20120201</enddate><creator>BARBOSA CAJUELA, Kássia</creator><creator>GUENKA DAUER, Paaron</creator><creator>CAMARGO ROSA, Miria</creator><creator>CUBA TERAN, Francisco Javier</creator><creator>ALBERTO GIACOMETTI, Jose</creator><general>Desalination Publications</general><general>Elsevier Limited</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QH</scope><scope>7QL</scope><scope>7QO</scope><scope>7ST</scope><scope>7T7</scope><scope>7TN</scope><scope>7UA</scope><scope>8FD</scope><scope>C1K</scope><scope>F1W</scope><scope>FR3</scope><scope>H96</scope><scope>H97</scope><scope>KR7</scope><scope>L.G</scope><scope>M7N</scope><scope>P64</scope><scope>SOI</scope><scope>7SU</scope></search><sort><creationdate>20120201</creationdate><title>Water quality monitoring by nanostructured films in a sensing unit system</title><author>BARBOSA CAJUELA, Kássia ; GUENKA DAUER, Paaron ; CAMARGO ROSA, Miria ; CUBA TERAN, Francisco Javier ; ALBERTO GIACOMETTI, Jose</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c276t-f4461c4770de6b106a3743622057e260e32be5b978a76e81b7f8ccd952b4ffed3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Applied sciences</topic><topic>Brazil</topic><topic>Change detection</topic><topic>Components</topic><topic>Detection</topic><topic>Electric impedance</topic><topic>Electric potential</topic><topic>Environmental monitoring</topic><topic>Exact sciences and technology</topic><topic>Freshwater</topic><topic>Mathematical analysis</topic><topic>Monitoring</topic><topic>Nanostructure</topic><topic>Pollution</topic><topic>Principal components analysis</topic><topic>River water</topic><topic>Rivers</topic><topic>Water monitoring</topic><topic>Water quality</topic><topic>Water quality management</topic><topic>Water treatment and pollution</topic><topic>Watersheds</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>BARBOSA CAJUELA, Kássia</creatorcontrib><creatorcontrib>GUENKA DAUER, Paaron</creatorcontrib><creatorcontrib>CAMARGO ROSA, Miria</creatorcontrib><creatorcontrib>CUBA TERAN, Francisco Javier</creatorcontrib><creatorcontrib>ALBERTO GIACOMETTI, Jose</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Aqualine</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Biotechnology Research Abstracts</collection><collection>Environment Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Oceanic Abstracts</collection><collection>Water Resources Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Engineering Research Database</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) 2: Ocean Technology, Policy & Non-Living Resources</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) 3: Aquatic Pollution & Environmental Quality</collection><collection>Civil Engineering Abstracts</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) Professional</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Environment Abstracts</collection><collection>Environmental Engineering Abstracts</collection><jtitle>Desalination and water treatment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>BARBOSA CAJUELA, Kássia</au><au>GUENKA DAUER, Paaron</au><au>CAMARGO ROSA, Miria</au><au>CUBA TERAN, Francisco Javier</au><au>ALBERTO GIACOMETTI, Jose</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Water quality monitoring by nanostructured films in a sensing unit system</atitle><jtitle>Desalination and water treatment</jtitle><date>2012-02-01</date><risdate>2012</risdate><volume>40</volume><issue>1-3</issue><spage>209</spage><epage>214</epage><pages>209-214</pages><issn>1944-3994</issn><eissn>1944-3986</eissn><abstract>Presented here is a study about the capability of a sensing unit to detect changes in river water quality. In order to determine its accuracy, water quality was monitored at 11 points along the Veado River in Presidente Prudente, Brazil. To have a basis for comparison, a water quality index (WQI) was developed following methods previously applied in different watersheds. Results showed an accurate relationship between WQI and electric impedance readings detected by the sensing unit. Principal components analysis (PCA) was used to derive results in a form that can be correlated with WQI calculated for each sample point, which showed the potential application of this device.</abstract><cop>L'Aquila</cop><pub>Desalination Publications</pub><doi>10.1080/19443994.2012.671172</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1944-3994 |
ispartof | Desalination and water treatment, 2012-02, Vol.40 (1-3), p.209-214 |
issn | 1944-3994 1944-3986 |
language | eng |
recordid | cdi_proquest_miscellaneous_1017971399 |
source | Alma/SFX Local Collection |
subjects | Applied sciences Brazil Change detection Components Detection Electric impedance Electric potential Environmental monitoring Exact sciences and technology Freshwater Mathematical analysis Monitoring Nanostructure Pollution Principal components analysis River water Rivers Water monitoring Water quality Water quality management Water treatment and pollution Watersheds |
title | Water quality monitoring by nanostructured films in a sensing unit system |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T11%3A09%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Water%20quality%20monitoring%20by%20nanostructured%20films%20in%20a%20sensing%20unit%20system&rft.jtitle=Desalination%20and%20water%20treatment&rft.au=BARBOSA%20CAJUELA,%20K%C3%A1ssia&rft.date=2012-02-01&rft.volume=40&rft.issue=1-3&rft.spage=209&rft.epage=214&rft.pages=209-214&rft.issn=1944-3994&rft.eissn=1944-3986&rft_id=info:doi/10.1080/19443994.2012.671172&rft_dat=%3Cproquest_cross%3E1934060552%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1934060552&rft_id=info:pmid/&rfr_iscdi=true |