Defining Concrete Compressive Strain in Unbonded Post-Tensioned Walls
The nominal flexural strength of a concrete member is determined when the strain at the extreme compression fiber reaches 0.003, which implies an accurate measurement or calculation of the concrete strains in the member's critical region. The challenges associated with defining this strain usin...
Gespeichert in:
Veröffentlicht in: | ACI structural journal 2012-01, Vol.109 (1), p.101-112 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 112 |
---|---|
container_issue | 1 |
container_start_page | 101 |
container_title | ACI structural journal |
container_volume | 109 |
creator | Henry, Richard S Brooke, Nicholas J Sritharan, Sri Ingham, Jason M |
description | The nominal flexural strength of a concrete member is determined when the strain at the extreme compression fiber reaches 0.003, which implies an accurate measurement or calculation of the concrete strains in the member's critical region. The challenges associated with defining this strain using experimental and analytical means were demonstrated for precast concrete walls with unbonded post-tensioning. A series of laboratory tests was conducted to verify the critical compressive strains in post-tensioned (PT) precast concrete walls, which had no special confinement reinforcement in the wall toe. Test results confirmed the expected behavior of the wall panels and indicated that the onset of visible crushing in the wall toe may not occur until compressive strains develop that are significantly greater than 0.003. Despite employing several techniques, however, including displacement gauges, strain gauges, and photogrammetry, obtaining reliable and accurate experimental concrete strain measurements in the toe region of the wall proved challenging. To improve the understanding of the strain quantification at the nominal limit state, finite element analyses were conducted and the analysis results were compared with the experimental data. While some of the measured and analytically estimated strains provided comparable results in the critical wall toe region, a large spread in measured strains was observed and the average from several measurement devices was required for an accurate estimation of the nominal limit state. Overall, the three-dimensional (3-D) finite element model enabled an accurate and reliable estimation of the average concrete compressive strain. Based on this research, a strain of 0.005 is recommended for defining the nominal flexural strength of PT concrete walls. [PUBLICATION ABSTRACT] |
doi_str_mv | 10.14359/51683499 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1010887594</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2564778081</sourcerecordid><originalsourceid>FETCH-LOGICAL-c289t-a171f66246c676093aa99461a96f462729a5fb3ffc40704bbc4d782f7894f76d3</originalsourceid><addsrcrecordid>eNpdkEtLAzEUhYMoWKsL_8HgShejeU2Su5RaH1BQsMXlkMkkkjJNajIV_PcGqxvhwr0XPg7nHITOCb4mnDVw0xChGAc4QBMCnNeSCXKIJlgpqBnl5Bid5LzGmGHK-ATN76zzwYf3ahaDSXa05dhsk83Zf9rqdUzah6rMKnQx9LavXmIe66UN2cdQ3jc9DPkUHTk9ZHv2u6dodT9fzh7rxfPD0-x2URuqYKw1kcQJQbkwQgoMTGsALogG4bigkoJuXMecMxxLzLvO8F4q6qQC7qTo2RRd7nW3KX7sbB7bjc_GDoMONu5ySzApQWUDvKAX_9B13KVQ3LVAhASKsSrQ1R4yKeacrGu3yW90-ipK7U-f7V-f7Buq9GVR</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>916792008</pqid></control><display><type>article</type><title>Defining Concrete Compressive Strain in Unbonded Post-Tensioned Walls</title><source>American Concrete Institute Online Journal Archives</source><creator>Henry, Richard S ; Brooke, Nicholas J ; Sritharan, Sri ; Ingham, Jason M</creator><creatorcontrib>Henry, Richard S ; Brooke, Nicholas J ; Sritharan, Sri ; Ingham, Jason M</creatorcontrib><description>The nominal flexural strength of a concrete member is determined when the strain at the extreme compression fiber reaches 0.003, which implies an accurate measurement or calculation of the concrete strains in the member's critical region. The challenges associated with defining this strain using experimental and analytical means were demonstrated for precast concrete walls with unbonded post-tensioning. A series of laboratory tests was conducted to verify the critical compressive strains in post-tensioned (PT) precast concrete walls, which had no special confinement reinforcement in the wall toe. Test results confirmed the expected behavior of the wall panels and indicated that the onset of visible crushing in the wall toe may not occur until compressive strains develop that are significantly greater than 0.003. Despite employing several techniques, however, including displacement gauges, strain gauges, and photogrammetry, obtaining reliable and accurate experimental concrete strain measurements in the toe region of the wall proved challenging. To improve the understanding of the strain quantification at the nominal limit state, finite element analyses were conducted and the analysis results were compared with the experimental data. While some of the measured and analytically estimated strains provided comparable results in the critical wall toe region, a large spread in measured strains was observed and the average from several measurement devices was required for an accurate estimation of the nominal limit state. Overall, the three-dimensional (3-D) finite element model enabled an accurate and reliable estimation of the average concrete compressive strain. Based on this research, a strain of 0.005 is recommended for defining the nominal flexural strength of PT concrete walls. [PUBLICATION ABSTRACT]</description><identifier>ISSN: 0889-3241</identifier><identifier>EISSN: 1944-7361</identifier><identifier>DOI: 10.14359/51683499</identifier><language>eng</language><publisher>Farmington Hills: American Concrete Institute</publisher><subject>Accuracy ; Compressive properties ; Concretes ; Design ; Limit states ; Mathematical analysis ; Mathematical models ; Modulus of rupture in bending ; Strain ; Strain gauges ; Studies ; Walls</subject><ispartof>ACI structural journal, 2012-01, Vol.109 (1), p.101-112</ispartof><rights>Copyright American Concrete Institute Jan/Feb 2012</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c289t-a171f66246c676093aa99461a96f462729a5fb3ffc40704bbc4d782f7894f76d3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,4010,27900,27901,27902</link.rule.ids></links><search><creatorcontrib>Henry, Richard S</creatorcontrib><creatorcontrib>Brooke, Nicholas J</creatorcontrib><creatorcontrib>Sritharan, Sri</creatorcontrib><creatorcontrib>Ingham, Jason M</creatorcontrib><title>Defining Concrete Compressive Strain in Unbonded Post-Tensioned Walls</title><title>ACI structural journal</title><description>The nominal flexural strength of a concrete member is determined when the strain at the extreme compression fiber reaches 0.003, which implies an accurate measurement or calculation of the concrete strains in the member's critical region. The challenges associated with defining this strain using experimental and analytical means were demonstrated for precast concrete walls with unbonded post-tensioning. A series of laboratory tests was conducted to verify the critical compressive strains in post-tensioned (PT) precast concrete walls, which had no special confinement reinforcement in the wall toe. Test results confirmed the expected behavior of the wall panels and indicated that the onset of visible crushing in the wall toe may not occur until compressive strains develop that are significantly greater than 0.003. Despite employing several techniques, however, including displacement gauges, strain gauges, and photogrammetry, obtaining reliable and accurate experimental concrete strain measurements in the toe region of the wall proved challenging. To improve the understanding of the strain quantification at the nominal limit state, finite element analyses were conducted and the analysis results were compared with the experimental data. While some of the measured and analytically estimated strains provided comparable results in the critical wall toe region, a large spread in measured strains was observed and the average from several measurement devices was required for an accurate estimation of the nominal limit state. Overall, the three-dimensional (3-D) finite element model enabled an accurate and reliable estimation of the average concrete compressive strain. Based on this research, a strain of 0.005 is recommended for defining the nominal flexural strength of PT concrete walls. [PUBLICATION ABSTRACT]</description><subject>Accuracy</subject><subject>Compressive properties</subject><subject>Concretes</subject><subject>Design</subject><subject>Limit states</subject><subject>Mathematical analysis</subject><subject>Mathematical models</subject><subject>Modulus of rupture in bending</subject><subject>Strain</subject><subject>Strain gauges</subject><subject>Studies</subject><subject>Walls</subject><issn>0889-3241</issn><issn>1944-7361</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>8G5</sourceid><sourceid>BENPR</sourceid><sourceid>GUQSH</sourceid><sourceid>M2O</sourceid><recordid>eNpdkEtLAzEUhYMoWKsL_8HgShejeU2Su5RaH1BQsMXlkMkkkjJNajIV_PcGqxvhwr0XPg7nHITOCb4mnDVw0xChGAc4QBMCnNeSCXKIJlgpqBnl5Bid5LzGmGHK-ATN76zzwYf3ahaDSXa05dhsk83Zf9rqdUzah6rMKnQx9LavXmIe66UN2cdQ3jc9DPkUHTk9ZHv2u6dodT9fzh7rxfPD0-x2URuqYKw1kcQJQbkwQgoMTGsALogG4bigkoJuXMecMxxLzLvO8F4q6qQC7qTo2RRd7nW3KX7sbB7bjc_GDoMONu5ySzApQWUDvKAX_9B13KVQ3LVAhASKsSrQ1R4yKeacrGu3yW90-ipK7U-f7V-f7Buq9GVR</recordid><startdate>20120101</startdate><enddate>20120101</enddate><creator>Henry, Richard S</creator><creator>Brooke, Nicholas J</creator><creator>Sritharan, Sri</creator><creator>Ingham, Jason M</creator><general>American Concrete Institute</general><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>4T-</scope><scope>4U-</scope><scope>7QQ</scope><scope>7SR</scope><scope>7XB</scope><scope>88I</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FK</scope><scope>8G5</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AEUYN</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FR3</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KR7</scope><scope>L6V</scope><scope>M2O</scope><scope>M2P</scope><scope>M7S</scope><scope>MBDVC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope><scope>Q9U</scope></search><sort><creationdate>20120101</creationdate><title>Defining Concrete Compressive Strain in Unbonded Post-Tensioned Walls</title><author>Henry, Richard S ; Brooke, Nicholas J ; Sritharan, Sri ; Ingham, Jason M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c289t-a171f66246c676093aa99461a96f462729a5fb3ffc40704bbc4d782f7894f76d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Accuracy</topic><topic>Compressive properties</topic><topic>Concretes</topic><topic>Design</topic><topic>Limit states</topic><topic>Mathematical analysis</topic><topic>Mathematical models</topic><topic>Modulus of rupture in bending</topic><topic>Strain</topic><topic>Strain gauges</topic><topic>Studies</topic><topic>Walls</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Henry, Richard S</creatorcontrib><creatorcontrib>Brooke, Nicholas J</creatorcontrib><creatorcontrib>Sritharan, Sri</creatorcontrib><creatorcontrib>Ingham, Jason M</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Docstoc</collection><collection>University Readers</collection><collection>Ceramic Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Science Database (Alumni Edition)</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest One Sustainability</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection (ProQuest)</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>ProQuest Engineering Collection</collection><collection>Research Library</collection><collection>Science Database</collection><collection>Engineering Database</collection><collection>Research Library (Corporate)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><collection>ProQuest Central Basic</collection><jtitle>ACI structural journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Henry, Richard S</au><au>Brooke, Nicholas J</au><au>Sritharan, Sri</au><au>Ingham, Jason M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Defining Concrete Compressive Strain in Unbonded Post-Tensioned Walls</atitle><jtitle>ACI structural journal</jtitle><date>2012-01-01</date><risdate>2012</risdate><volume>109</volume><issue>1</issue><spage>101</spage><epage>112</epage><pages>101-112</pages><issn>0889-3241</issn><eissn>1944-7361</eissn><abstract>The nominal flexural strength of a concrete member is determined when the strain at the extreme compression fiber reaches 0.003, which implies an accurate measurement or calculation of the concrete strains in the member's critical region. The challenges associated with defining this strain using experimental and analytical means were demonstrated for precast concrete walls with unbonded post-tensioning. A series of laboratory tests was conducted to verify the critical compressive strains in post-tensioned (PT) precast concrete walls, which had no special confinement reinforcement in the wall toe. Test results confirmed the expected behavior of the wall panels and indicated that the onset of visible crushing in the wall toe may not occur until compressive strains develop that are significantly greater than 0.003. Despite employing several techniques, however, including displacement gauges, strain gauges, and photogrammetry, obtaining reliable and accurate experimental concrete strain measurements in the toe region of the wall proved challenging. To improve the understanding of the strain quantification at the nominal limit state, finite element analyses were conducted and the analysis results were compared with the experimental data. While some of the measured and analytically estimated strains provided comparable results in the critical wall toe region, a large spread in measured strains was observed and the average from several measurement devices was required for an accurate estimation of the nominal limit state. Overall, the three-dimensional (3-D) finite element model enabled an accurate and reliable estimation of the average concrete compressive strain. Based on this research, a strain of 0.005 is recommended for defining the nominal flexural strength of PT concrete walls. [PUBLICATION ABSTRACT]</abstract><cop>Farmington Hills</cop><pub>American Concrete Institute</pub><doi>10.14359/51683499</doi><tpages>12</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0889-3241 |
ispartof | ACI structural journal, 2012-01, Vol.109 (1), p.101-112 |
issn | 0889-3241 1944-7361 |
language | eng |
recordid | cdi_proquest_miscellaneous_1010887594 |
source | American Concrete Institute Online Journal Archives |
subjects | Accuracy Compressive properties Concretes Design Limit states Mathematical analysis Mathematical models Modulus of rupture in bending Strain Strain gauges Studies Walls |
title | Defining Concrete Compressive Strain in Unbonded Post-Tensioned Walls |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T00%3A20%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Defining%20Concrete%20Compressive%20Strain%20in%20Unbonded%20Post-Tensioned%20Walls&rft.jtitle=ACI%20structural%20journal&rft.au=Henry,%20Richard%20S&rft.date=2012-01-01&rft.volume=109&rft.issue=1&rft.spage=101&rft.epage=112&rft.pages=101-112&rft.issn=0889-3241&rft.eissn=1944-7361&rft_id=info:doi/10.14359/51683499&rft_dat=%3Cproquest_cross%3E2564778081%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=916792008&rft_id=info:pmid/&rfr_iscdi=true |