Study and optimization of multiwire proportional chambers for Synchrotron facilities
Multiwire proportional chambers (MWPCs) are widely used in many different disciplines. The quality of the results depends on many factors such as gas gain, detector count rate, detection efficiency, spatial and energy resolution, and uniformity. We report here on a detailed study on how to optimize...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on nuclear science 2006-04, Vol.53 (2), p.544-548 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 548 |
---|---|
container_issue | 2 |
container_start_page | 544 |
container_title | IEEE transactions on nuclear science |
container_volume | 53 |
creator | Fernandez, F. Ramos-Lerate, I. Kocsis, M. Martinez, J.C. Beltran, D. Bordas, J. Toledo, J. |
description | Multiwire proportional chambers (MWPCs) are widely used in many different disciplines. The quality of the results depends on many factors such as gas gain, detector count rate, detection efficiency, spatial and energy resolution, and uniformity. We report here on a detailed study on how to optimize all these features, in particular regarding the use of MWPC at synchrotron radiation sources. Detector behavior has been analyzed in relation to geometry of the wire planes; electric field; frames design and window geometry; and gas parameters. From this study, general optimization criteria were obtained. The results of this study have been applied to produce a new design for a detector required to perform time-resolved X-ray diffraction/scattering experiments in the submillisecond time scale with a spatial resolution of 0.03 cm. In addition, we report on the outcome of simulations aiming at understanding the influence of manufacturing defects as well as gas quality. |
doi_str_mv | 10.1109/TNS.2006.871257 |
format | Article |
fullrecord | <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_proquest_journals_912090943</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1621361</ieee_id><sourcerecordid>1671275946</sourcerecordid><originalsourceid>FETCH-LOGICAL-c418t-5b9351b49e52a04467d5de9bdc92f1ab5c2c8114c304d065d750f544446a322f3</originalsourceid><addsrcrecordid>eNp9kU1LxDAQhoMouK6ePXgpHsRLdzNp0jZHEb9g0cOu55CmKZulbWqSIuuvN0sFwYNzGWZ43mFmXoQuAS8AMF9uXtcLgnG-KAsgrDhCM2CsTIEV5TGaYQxlyinnp-jM-10sKcNshjbrMNb7RPZ1YodgOvMlg7F9YpukG9tgPo3TyeDsYN2hL9tEbWVXaeeTxrpkve_V1tngoqSRyrQmGO3P0UkjW68vfvIcvT8-bO6f09Xb08v93SpVFMqQsopnDCrKNSMSU5oXNas1r2rFSQOyYoqoEoCqDNMa56wuGG4YjZHLjJAmm6ObaW5c8GPUPojOeKXbVvbajl6QEnC8FEfw9l8Q8vizgnGaR_T6D7qzo4uHe8GBYI45zSK0nCDlrPdON2JwppNuLwCLgxsiuiEObojJjai4mhRGa_1L5wSyHLJv1nCFpg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>912090943</pqid></control><display><type>article</type><title>Study and optimization of multiwire proportional chambers for Synchrotron facilities</title><source>IEEE Electronic Library (IEL)</source><creator>Fernandez, F. ; Ramos-Lerate, I. ; Kocsis, M. ; Martinez, J.C. ; Beltran, D. ; Bordas, J. ; Toledo, J.</creator><creatorcontrib>Fernandez, F. ; Ramos-Lerate, I. ; Kocsis, M. ; Martinez, J.C. ; Beltran, D. ; Bordas, J. ; Toledo, J.</creatorcontrib><description>Multiwire proportional chambers (MWPCs) are widely used in many different disciplines. The quality of the results depends on many factors such as gas gain, detector count rate, detection efficiency, spatial and energy resolution, and uniformity. We report here on a detailed study on how to optimize all these features, in particular regarding the use of MWPC at synchrotron radiation sources. Detector behavior has been analyzed in relation to geometry of the wire planes; electric field; frames design and window geometry; and gas parameters. From this study, general optimization criteria were obtained. The results of this study have been applied to produce a new design for a detector required to perform time-resolved X-ray diffraction/scattering experiments in the submillisecond time scale with a spatial resolution of 0.03 cm. In addition, we report on the outcome of simulations aiming at understanding the influence of manufacturing defects as well as gas quality.</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/TNS.2006.871257</identifier><identifier>CODEN: IETNAE</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Chambers ; Criteria ; Detectors ; Diffraction ; Electric fields ; Energy resolution ; Gas detectors ; Geometry ; Manufacturing defects ; Optimization ; proportional counter ; Spatial resolution ; Synchrotron radiation ; Virtual manufacturing ; Wire ; X-ray detection ; X-ray detectors ; X-ray diffraction ; X-ray scattering</subject><ispartof>IEEE transactions on nuclear science, 2006-04, Vol.53 (2), p.544-548</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2006</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c418t-5b9351b49e52a04467d5de9bdc92f1ab5c2c8114c304d065d750f544446a322f3</citedby><cites>FETCH-LOGICAL-c418t-5b9351b49e52a04467d5de9bdc92f1ab5c2c8114c304d065d750f544446a322f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1621361$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1621361$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Fernandez, F.</creatorcontrib><creatorcontrib>Ramos-Lerate, I.</creatorcontrib><creatorcontrib>Kocsis, M.</creatorcontrib><creatorcontrib>Martinez, J.C.</creatorcontrib><creatorcontrib>Beltran, D.</creatorcontrib><creatorcontrib>Bordas, J.</creatorcontrib><creatorcontrib>Toledo, J.</creatorcontrib><title>Study and optimization of multiwire proportional chambers for Synchrotron facilities</title><title>IEEE transactions on nuclear science</title><addtitle>TNS</addtitle><description>Multiwire proportional chambers (MWPCs) are widely used in many different disciplines. The quality of the results depends on many factors such as gas gain, detector count rate, detection efficiency, spatial and energy resolution, and uniformity. We report here on a detailed study on how to optimize all these features, in particular regarding the use of MWPC at synchrotron radiation sources. Detector behavior has been analyzed in relation to geometry of the wire planes; electric field; frames design and window geometry; and gas parameters. From this study, general optimization criteria were obtained. The results of this study have been applied to produce a new design for a detector required to perform time-resolved X-ray diffraction/scattering experiments in the submillisecond time scale with a spatial resolution of 0.03 cm. In addition, we report on the outcome of simulations aiming at understanding the influence of manufacturing defects as well as gas quality.</description><subject>Chambers</subject><subject>Criteria</subject><subject>Detectors</subject><subject>Diffraction</subject><subject>Electric fields</subject><subject>Energy resolution</subject><subject>Gas detectors</subject><subject>Geometry</subject><subject>Manufacturing defects</subject><subject>Optimization</subject><subject>proportional counter</subject><subject>Spatial resolution</subject><subject>Synchrotron radiation</subject><subject>Virtual manufacturing</subject><subject>Wire</subject><subject>X-ray detection</subject><subject>X-ray detectors</subject><subject>X-ray diffraction</subject><subject>X-ray scattering</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNp9kU1LxDAQhoMouK6ePXgpHsRLdzNp0jZHEb9g0cOu55CmKZulbWqSIuuvN0sFwYNzGWZ43mFmXoQuAS8AMF9uXtcLgnG-KAsgrDhCM2CsTIEV5TGaYQxlyinnp-jM-10sKcNshjbrMNb7RPZ1YodgOvMlg7F9YpukG9tgPo3TyeDsYN2hL9tEbWVXaeeTxrpkve_V1tngoqSRyrQmGO3P0UkjW68vfvIcvT8-bO6f09Xb08v93SpVFMqQsopnDCrKNSMSU5oXNas1r2rFSQOyYoqoEoCqDNMa56wuGG4YjZHLjJAmm6ObaW5c8GPUPojOeKXbVvbajl6QEnC8FEfw9l8Q8vizgnGaR_T6D7qzo4uHe8GBYI45zSK0nCDlrPdON2JwppNuLwCLgxsiuiEObojJjai4mhRGa_1L5wSyHLJv1nCFpg</recordid><startdate>20060401</startdate><enddate>20060401</enddate><creator>Fernandez, F.</creator><creator>Ramos-Lerate, I.</creator><creator>Kocsis, M.</creator><creator>Martinez, J.C.</creator><creator>Beltran, D.</creator><creator>Bordas, J.</creator><creator>Toledo, J.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QL</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7T7</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>M7N</scope><scope>P64</scope></search><sort><creationdate>20060401</creationdate><title>Study and optimization of multiwire proportional chambers for Synchrotron facilities</title><author>Fernandez, F. ; Ramos-Lerate, I. ; Kocsis, M. ; Martinez, J.C. ; Beltran, D. ; Bordas, J. ; Toledo, J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c418t-5b9351b49e52a04467d5de9bdc92f1ab5c2c8114c304d065d750f544446a322f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Chambers</topic><topic>Criteria</topic><topic>Detectors</topic><topic>Diffraction</topic><topic>Electric fields</topic><topic>Energy resolution</topic><topic>Gas detectors</topic><topic>Geometry</topic><topic>Manufacturing defects</topic><topic>Optimization</topic><topic>proportional counter</topic><topic>Spatial resolution</topic><topic>Synchrotron radiation</topic><topic>Virtual manufacturing</topic><topic>Wire</topic><topic>X-ray detection</topic><topic>X-ray detectors</topic><topic>X-ray diffraction</topic><topic>X-ray scattering</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fernandez, F.</creatorcontrib><creatorcontrib>Ramos-Lerate, I.</creatorcontrib><creatorcontrib>Kocsis, M.</creatorcontrib><creatorcontrib>Martinez, J.C.</creatorcontrib><creatorcontrib>Beltran, D.</creatorcontrib><creatorcontrib>Bordas, J.</creatorcontrib><creatorcontrib>Toledo, J.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Fernandez, F.</au><au>Ramos-Lerate, I.</au><au>Kocsis, M.</au><au>Martinez, J.C.</au><au>Beltran, D.</au><au>Bordas, J.</au><au>Toledo, J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Study and optimization of multiwire proportional chambers for Synchrotron facilities</atitle><jtitle>IEEE transactions on nuclear science</jtitle><stitle>TNS</stitle><date>2006-04-01</date><risdate>2006</risdate><volume>53</volume><issue>2</issue><spage>544</spage><epage>548</epage><pages>544-548</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><coden>IETNAE</coden><abstract>Multiwire proportional chambers (MWPCs) are widely used in many different disciplines. The quality of the results depends on many factors such as gas gain, detector count rate, detection efficiency, spatial and energy resolution, and uniformity. We report here on a detailed study on how to optimize all these features, in particular regarding the use of MWPC at synchrotron radiation sources. Detector behavior has been analyzed in relation to geometry of the wire planes; electric field; frames design and window geometry; and gas parameters. From this study, general optimization criteria were obtained. The results of this study have been applied to produce a new design for a detector required to perform time-resolved X-ray diffraction/scattering experiments in the submillisecond time scale with a spatial resolution of 0.03 cm. In addition, we report on the outcome of simulations aiming at understanding the influence of manufacturing defects as well as gas quality.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TNS.2006.871257</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0018-9499 |
ispartof | IEEE transactions on nuclear science, 2006-04, Vol.53 (2), p.544-548 |
issn | 0018-9499 1558-1578 |
language | eng |
recordid | cdi_proquest_journals_912090943 |
source | IEEE Electronic Library (IEL) |
subjects | Chambers Criteria Detectors Diffraction Electric fields Energy resolution Gas detectors Geometry Manufacturing defects Optimization proportional counter Spatial resolution Synchrotron radiation Virtual manufacturing Wire X-ray detection X-ray detectors X-ray diffraction X-ray scattering |
title | Study and optimization of multiwire proportional chambers for Synchrotron facilities |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T21%3A51%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Study%20and%20optimization%20of%20multiwire%20proportional%20chambers%20for%20Synchrotron%20facilities&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=Fernandez,%20F.&rft.date=2006-04-01&rft.volume=53&rft.issue=2&rft.spage=544&rft.epage=548&rft.pages=544-548&rft.issn=0018-9499&rft.eissn=1558-1578&rft.coden=IETNAE&rft_id=info:doi/10.1109/TNS.2006.871257&rft_dat=%3Cproquest_RIE%3E1671275946%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=912090943&rft_id=info:pmid/&rft_ieee_id=1621361&rfr_iscdi=true |