Non-Destructive Testing of YBCO Coated-Conductor by Multi-Channel HTS SQUID Gradiometers

We developed a non-destructive testing (NDT) system utilizing multi-channel high-temperature superconductor (HTS) SQUID gradiometers in order to examine rare earth (RE)-123 coated conductors striated into multi-filamentary lines. The 5-channel HTS SQUID gradiometer array was composed of ramp-edge ju...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on applied superconductivity 2009-06, Vol.19 (3), p.804-807
Hauptverfasser: Hato, T., Adachi, S., Wakana, H., Hata, K., Tarutani, Y., Machi, T., Tanabe, K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We developed a non-destructive testing (NDT) system utilizing multi-channel high-temperature superconductor (HTS) SQUID gradiometers in order to examine rare earth (RE)-123 coated conductors striated into multi-filamentary lines. The 5-channel HTS SQUID gradiometer array was composed of ramp-edge junctions with LaErBaCuO and SmBaCuO electrode layers, and fabricated by using an HTS multilayer fabrication technique. The parallel gradiometers detected the vertical element of magnetic field gradient induced around defects by an eddy current. It was demonstrated that we can detect macroscopic defects in each filamentary superconducting line at high speed up to 30 m/h.
ISSN:1051-8223
1558-2515
DOI:10.1109/TASC.2009.2019025