Fracture strength and fatigue of polysilicon determined by a novel thermal actuator [MEMS]
A novel thermal actuator for the determination of polysilicon fracture strength and investigation of its fatigue is presented. The actuator consists of two narrow beams, which expand due to electrical heating, and a cold plate to which a short fracture beam is attached. Because of its small dimensio...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on electron devices 2000-07, Vol.47 (7), p.1522-1528 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1528 |
---|---|
container_issue | 7 |
container_start_page | 1522 |
container_title | IEEE transactions on electron devices |
container_volume | 47 |
creator | Kapels, H. Aigner, R. Binder, J. |
description | A novel thermal actuator for the determination of polysilicon fracture strength and investigation of its fatigue is presented. The actuator consists of two narrow beams, which expand due to electrical heating, and a cold plate to which a short fracture beam is attached. Because of its small dimensions, the actuator can be used for on-wafer testing. This method is suitable for tensile and compressive material. Using different types of fracture beams fracture strengths were compared for uniaxial tension and bending test. Using Weibull statistics, the fracture strength for polysilicon has been found to be (2.9/spl plusmn/0.5) GPa in tensile tests and (3.4/spl plusmn/0.5) GPa in bending tests. In fatigue investigations, we observe that fracture strength decreases slowly with time to 2.2 GPa after 10/sup 6/ cycles. |
doi_str_mv | 10.1109/16.848302 |
format | Article |
fullrecord | <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_proquest_journals_885233327</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>848302</ieee_id><sourcerecordid>2435130511</sourcerecordid><originalsourceid>FETCH-LOGICAL-c370t-5c3817d084397df02da9dac70cdac57131bac42a9ded3173499baa5ac8467143</originalsourceid><addsrcrecordid>eNpdkM1LAzEQxYMoWKsHr56CB8HD1nxuskcprQotHuxJkZAm2XbLdlOTrND_3pSKBy8zzJsfj8cD4BqjEcaoesDlSDJJETkBA8y5KKqSladggBCWRUUlPQcXMW7yWTJGBuB9GrRJfXAwpuC6VVpD3VlY69Ssegd9DXe-3cembYzvoHXJhW3TOQuXe6hh579dC9M6i7qFByOdfIAf88n87fMSnNW6je7qdw_BYjpZjJ-L2evTy_hxVhgqUCq4oRILiySjlbA1IlZXVhuBTJ5cYIqX2jCSRWcpFpRV1VJrro1kpcCMDsHd0XYX_FfvYlLbJhrXtrpzvo-KCE64QGUGb_-BG9-HLkdTUnJCKSUiQ_dHyAQfY3C12oVmq8NeYaQODStcqmPDmb05so1z7o_7ff4AMpR11A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>885233327</pqid></control><display><type>article</type><title>Fracture strength and fatigue of polysilicon determined by a novel thermal actuator [MEMS]</title><source>IEEE Electronic Library (IEL)</source><creator>Kapels, H. ; Aigner, R. ; Binder, J.</creator><creatorcontrib>Kapels, H. ; Aigner, R. ; Binder, J.</creatorcontrib><description>A novel thermal actuator for the determination of polysilicon fracture strength and investigation of its fatigue is presented. The actuator consists of two narrow beams, which expand due to electrical heating, and a cold plate to which a short fracture beam is attached. Because of its small dimensions, the actuator can be used for on-wafer testing. This method is suitable for tensile and compressive material. Using different types of fracture beams fracture strengths were compared for uniaxial tension and bending test. Using Weibull statistics, the fracture strength for polysilicon has been found to be (2.9/spl plusmn/0.5) GPa in tensile tests and (3.4/spl plusmn/0.5) GPa in bending tests. In fatigue investigations, we observe that fracture strength decreases slowly with time to 2.2 GPa after 10/sup 6/ cycles.</description><identifier>ISSN: 0018-9383</identifier><identifier>EISSN: 1557-9646</identifier><identifier>DOI: 10.1109/16.848302</identifier><identifier>CODEN: IETDAI</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Fatigue</subject><ispartof>IEEE transactions on electron devices, 2000-07, Vol.47 (7), p.1522-1528</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2000</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c370t-5c3817d084397df02da9dac70cdac57131bac42a9ded3173499baa5ac8467143</citedby><cites>FETCH-LOGICAL-c370t-5c3817d084397df02da9dac70cdac57131bac42a9ded3173499baa5ac8467143</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/848302$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/848302$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Kapels, H.</creatorcontrib><creatorcontrib>Aigner, R.</creatorcontrib><creatorcontrib>Binder, J.</creatorcontrib><title>Fracture strength and fatigue of polysilicon determined by a novel thermal actuator [MEMS]</title><title>IEEE transactions on electron devices</title><addtitle>TED</addtitle><description>A novel thermal actuator for the determination of polysilicon fracture strength and investigation of its fatigue is presented. The actuator consists of two narrow beams, which expand due to electrical heating, and a cold plate to which a short fracture beam is attached. Because of its small dimensions, the actuator can be used for on-wafer testing. This method is suitable for tensile and compressive material. Using different types of fracture beams fracture strengths were compared for uniaxial tension and bending test. Using Weibull statistics, the fracture strength for polysilicon has been found to be (2.9/spl plusmn/0.5) GPa in tensile tests and (3.4/spl plusmn/0.5) GPa in bending tests. In fatigue investigations, we observe that fracture strength decreases slowly with time to 2.2 GPa after 10/sup 6/ cycles.</description><subject>Fatigue</subject><issn>0018-9383</issn><issn>1557-9646</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNpdkM1LAzEQxYMoWKsHr56CB8HD1nxuskcprQotHuxJkZAm2XbLdlOTrND_3pSKBy8zzJsfj8cD4BqjEcaoesDlSDJJETkBA8y5KKqSladggBCWRUUlPQcXMW7yWTJGBuB9GrRJfXAwpuC6VVpD3VlY69Ssegd9DXe-3cembYzvoHXJhW3TOQuXe6hh579dC9M6i7qFByOdfIAf88n87fMSnNW6je7qdw_BYjpZjJ-L2evTy_hxVhgqUCq4oRILiySjlbA1IlZXVhuBTJ5cYIqX2jCSRWcpFpRV1VJrro1kpcCMDsHd0XYX_FfvYlLbJhrXtrpzvo-KCE64QGUGb_-BG9-HLkdTUnJCKSUiQ_dHyAQfY3C12oVmq8NeYaQODStcqmPDmb05so1z7o_7ff4AMpR11A</recordid><startdate>200007</startdate><enddate>200007</enddate><creator>Kapels, H.</creator><creator>Aigner, R.</creator><creator>Binder, J.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>L7M</scope><scope>7U5</scope></search><sort><creationdate>200007</creationdate><title>Fracture strength and fatigue of polysilicon determined by a novel thermal actuator [MEMS]</title><author>Kapels, H. ; Aigner, R. ; Binder, J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c370t-5c3817d084397df02da9dac70cdac57131bac42a9ded3173499baa5ac8467143</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Fatigue</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kapels, H.</creatorcontrib><creatorcontrib>Aigner, R.</creatorcontrib><creatorcontrib>Binder, J.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Solid State and Superconductivity Abstracts</collection><jtitle>IEEE transactions on electron devices</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Kapels, H.</au><au>Aigner, R.</au><au>Binder, J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fracture strength and fatigue of polysilicon determined by a novel thermal actuator [MEMS]</atitle><jtitle>IEEE transactions on electron devices</jtitle><stitle>TED</stitle><date>2000-07</date><risdate>2000</risdate><volume>47</volume><issue>7</issue><spage>1522</spage><epage>1528</epage><pages>1522-1528</pages><issn>0018-9383</issn><eissn>1557-9646</eissn><coden>IETDAI</coden><abstract>A novel thermal actuator for the determination of polysilicon fracture strength and investigation of its fatigue is presented. The actuator consists of two narrow beams, which expand due to electrical heating, and a cold plate to which a short fracture beam is attached. Because of its small dimensions, the actuator can be used for on-wafer testing. This method is suitable for tensile and compressive material. Using different types of fracture beams fracture strengths were compared for uniaxial tension and bending test. Using Weibull statistics, the fracture strength for polysilicon has been found to be (2.9/spl plusmn/0.5) GPa in tensile tests and (3.4/spl plusmn/0.5) GPa in bending tests. In fatigue investigations, we observe that fracture strength decreases slowly with time to 2.2 GPa after 10/sup 6/ cycles.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/16.848302</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0018-9383 |
ispartof | IEEE transactions on electron devices, 2000-07, Vol.47 (7), p.1522-1528 |
issn | 0018-9383 1557-9646 |
language | eng |
recordid | cdi_proquest_journals_885233327 |
source | IEEE Electronic Library (IEL) |
subjects | Fatigue |
title | Fracture strength and fatigue of polysilicon determined by a novel thermal actuator [MEMS] |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T07%3A51%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fracture%20strength%20and%20fatigue%20of%20polysilicon%20determined%20by%20a%20novel%20thermal%20actuator%20%5BMEMS%5D&rft.jtitle=IEEE%20transactions%20on%20electron%20devices&rft.au=Kapels,%20H.&rft.date=2000-07&rft.volume=47&rft.issue=7&rft.spage=1522&rft.epage=1528&rft.pages=1522-1528&rft.issn=0018-9383&rft.eissn=1557-9646&rft.coden=IETDAI&rft_id=info:doi/10.1109/16.848302&rft_dat=%3Cproquest_RIE%3E2435130511%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=885233327&rft_id=info:pmid/&rft_ieee_id=848302&rfr_iscdi=true |