Robust sensor fusion improves heart rate estimation : Clinical evaluation

To determine if Robust Sensor Fusion (RSF), a method designed to fuse data from multiple sensors with redundant heart rate information can be used to improve the quality of heart rate data. To determine if the improved estimate of heart rate can reduce the number of false and missed heart rate alarm...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical monitoring 1997-11, Vol.13 (6), p.379-384
Hauptverfasser: FELDMAN, J. M, EBRAHIM, M. H, BAR-KANA, I
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 384
container_issue 6
container_start_page 379
container_title Journal of clinical monitoring
container_volume 13
creator FELDMAN, J. M
EBRAHIM, M. H
BAR-KANA, I
description To determine if Robust Sensor Fusion (RSF), a method designed to fuse data from multiple sensors with redundant heart rate information can be used to improve the quality of heart rate data. To determine if the improved estimate of heart rate can reduce the number of false and missed heart rate alarms. A total of 85 monitoring periods were investigated, 12 from the operating room, 60 from adult ICU and 13 from pediatric ICU. The operating room periods began with induction of anesthesia and ended at the completion of the anesthetic. For the ICU data, four hour blocks of time were studied. For each monitoring period, HR values were recorded at 5 second intervals or less from the ECG, SpO2 and IAC using a SpaceLabs Medical Gateway connected to a SpaceLabs Medical PC2. Fused estimates of HR were derived for every time point using RSF and all results accepted regardless of confidence value. Data were annotated manually to identify the "reference" HR (that HR value most likely to be correct) at all time points. All HR values from the sensors and the fused estimate that were different from the reference HR by more than +/- 5 beats/min were considered inaccurate. For each monitoring period, the total time per hour that data were either inaccurate or unavailable was calculated for each sensor as well as the fused estimates. The total time of false and missed HR alarms was found for all sensors and the fused estimate by comparing the data to thresholds for both high and low HR alarms at 150 bpm, 130 bpm, 110 bpm and 50 bpm, 40 bpm, 30 bpm respectively. The fused estimate of HR was consistently as good or better than the estimate available from any individual sensor. The fused estimates also consistently reduced the incidence of false alarms compared with individual sensors without an unacceptable incidence of missed alarms. Redundancy in sensor measurements can be used to improve HR estimation in the clinical setting. Methods like RSF which improve the quality of monitored data and reduce nuisance alarms will enhance the value of patient monitors to clinicians.
doi_str_mv 10.1023/A:1007476707284
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_journals_863395295</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2329458171</sourcerecordid><originalsourceid>FETCH-LOGICAL-c308t-a19591fde7dac78175375564723eb32baa755a2b22af27ec624262fabd3c1dd03</originalsourceid><addsrcrecordid>eNpdkM1Lw0AQxRdRaq2ePQmLiLfo7uwmk-2tFD8KBUH0HCbJBlPSpO4mBf97txo8eBpm3o_hvcfYpRR3UoC6X8ylEKgxQYGQ6iM2BZA6QqXEMZsGJY2kQTxlZ95vhBCQGpiwidEmBiOmbPXa5YPvubet7xyvBl93La-3O9ftrecfllzPHfWWW9_XW-oP8pwvm7qtC2q43VMz_FzP2UlFjbcX45yx98eHt-VztH55Wi0X66hQIu0jkiY2siotllRgKjFWGMeJRlA2V5AThZUgB6AK0BYJaEigorxUhSxLoWbs9vdvsPg5BFfZtvaFbRpqbTf4DE2MMoEkgNf_wE03uDZ4y9JEqUMBcYCuRmjIt7bMdi6EdF_ZWFDQb0adfMhbOWqL2v9hIFFrKdQ3oN5zqg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>863395295</pqid></control><display><type>article</type><title>Robust sensor fusion improves heart rate estimation : Clinical evaluation</title><source>MEDLINE</source><source>SpringerNature Journals</source><creator>FELDMAN, J. M ; EBRAHIM, M. H ; BAR-KANA, I</creator><creatorcontrib>FELDMAN, J. M ; EBRAHIM, M. H ; BAR-KANA, I</creatorcontrib><description>To determine if Robust Sensor Fusion (RSF), a method designed to fuse data from multiple sensors with redundant heart rate information can be used to improve the quality of heart rate data. To determine if the improved estimate of heart rate can reduce the number of false and missed heart rate alarms. A total of 85 monitoring periods were investigated, 12 from the operating room, 60 from adult ICU and 13 from pediatric ICU. The operating room periods began with induction of anesthesia and ended at the completion of the anesthetic. For the ICU data, four hour blocks of time were studied. For each monitoring period, HR values were recorded at 5 second intervals or less from the ECG, SpO2 and IAC using a SpaceLabs Medical Gateway connected to a SpaceLabs Medical PC2. Fused estimates of HR were derived for every time point using RSF and all results accepted regardless of confidence value. Data were annotated manually to identify the "reference" HR (that HR value most likely to be correct) at all time points. All HR values from the sensors and the fused estimate that were different from the reference HR by more than +/- 5 beats/min were considered inaccurate. For each monitoring period, the total time per hour that data were either inaccurate or unavailable was calculated for each sensor as well as the fused estimates. The total time of false and missed HR alarms was found for all sensors and the fused estimate by comparing the data to thresholds for both high and low HR alarms at 150 bpm, 130 bpm, 110 bpm and 50 bpm, 40 bpm, 30 bpm respectively. The fused estimate of HR was consistently as good or better than the estimate available from any individual sensor. The fused estimates also consistently reduced the incidence of false alarms compared with individual sensors without an unacceptable incidence of missed alarms. Redundancy in sensor measurements can be used to improve HR estimation in the clinical setting. Methods like RSF which improve the quality of monitored data and reduce nuisance alarms will enhance the value of patient monitors to clinicians.</description><identifier>ISSN: 0748-1977</identifier><identifier>ISSN: 1387-1307</identifier><identifier>EISSN: 2214-7330</identifier><identifier>EISSN: 1573-2614</identifier><identifier>DOI: 10.1023/A:1007476707284</identifier><identifier>PMID: 9495290</identifier><identifier>CODEN: JCMOEH</identifier><language>eng</language><publisher>Boston, MA: Little</publisher><subject>Adult ; Anesthesia ; Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy ; Anesthesia: equipment, devices ; Biological and medical sciences ; Child ; Electrocardiography ; Estimates ; Heart Rate ; Humans ; Intensive Care Units ; Medical sciences ; Monitoring, Intraoperative ; Monitoring, Physiologic ; Sensors ; Signal Processing, Computer-Assisted ; Studies</subject><ispartof>Journal of clinical monitoring, 1997-11, Vol.13 (6), p.379-384</ispartof><rights>1998 INIST-CNRS</rights><rights>Kluwer Academic Publishers 1997</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c308t-a19591fde7dac78175375564723eb32baa755a2b22af27ec624262fabd3c1dd03</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2174410$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9495290$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>FELDMAN, J. M</creatorcontrib><creatorcontrib>EBRAHIM, M. H</creatorcontrib><creatorcontrib>BAR-KANA, I</creatorcontrib><title>Robust sensor fusion improves heart rate estimation : Clinical evaluation</title><title>Journal of clinical monitoring</title><addtitle>J Clin Monit</addtitle><description>To determine if Robust Sensor Fusion (RSF), a method designed to fuse data from multiple sensors with redundant heart rate information can be used to improve the quality of heart rate data. To determine if the improved estimate of heart rate can reduce the number of false and missed heart rate alarms. A total of 85 monitoring periods were investigated, 12 from the operating room, 60 from adult ICU and 13 from pediatric ICU. The operating room periods began with induction of anesthesia and ended at the completion of the anesthetic. For the ICU data, four hour blocks of time were studied. For each monitoring period, HR values were recorded at 5 second intervals or less from the ECG, SpO2 and IAC using a SpaceLabs Medical Gateway connected to a SpaceLabs Medical PC2. Fused estimates of HR were derived for every time point using RSF and all results accepted regardless of confidence value. Data were annotated manually to identify the "reference" HR (that HR value most likely to be correct) at all time points. All HR values from the sensors and the fused estimate that were different from the reference HR by more than +/- 5 beats/min were considered inaccurate. For each monitoring period, the total time per hour that data were either inaccurate or unavailable was calculated for each sensor as well as the fused estimates. The total time of false and missed HR alarms was found for all sensors and the fused estimate by comparing the data to thresholds for both high and low HR alarms at 150 bpm, 130 bpm, 110 bpm and 50 bpm, 40 bpm, 30 bpm respectively. The fused estimate of HR was consistently as good or better than the estimate available from any individual sensor. The fused estimates also consistently reduced the incidence of false alarms compared with individual sensors without an unacceptable incidence of missed alarms. Redundancy in sensor measurements can be used to improve HR estimation in the clinical setting. Methods like RSF which improve the quality of monitored data and reduce nuisance alarms will enhance the value of patient monitors to clinicians.</description><subject>Adult</subject><subject>Anesthesia</subject><subject>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</subject><subject>Anesthesia: equipment, devices</subject><subject>Biological and medical sciences</subject><subject>Child</subject><subject>Electrocardiography</subject><subject>Estimates</subject><subject>Heart Rate</subject><subject>Humans</subject><subject>Intensive Care Units</subject><subject>Medical sciences</subject><subject>Monitoring, Intraoperative</subject><subject>Monitoring, Physiologic</subject><subject>Sensors</subject><subject>Signal Processing, Computer-Assisted</subject><subject>Studies</subject><issn>0748-1977</issn><issn>1387-1307</issn><issn>2214-7330</issn><issn>1573-2614</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNpdkM1Lw0AQxRdRaq2ePQmLiLfo7uwmk-2tFD8KBUH0HCbJBlPSpO4mBf97txo8eBpm3o_hvcfYpRR3UoC6X8ylEKgxQYGQ6iM2BZA6QqXEMZsGJY2kQTxlZ95vhBCQGpiwidEmBiOmbPXa5YPvubet7xyvBl93La-3O9ftrecfllzPHfWWW9_XW-oP8pwvm7qtC2q43VMz_FzP2UlFjbcX45yx98eHt-VztH55Wi0X66hQIu0jkiY2siotllRgKjFWGMeJRlA2V5AThZUgB6AK0BYJaEigorxUhSxLoWbs9vdvsPg5BFfZtvaFbRpqbTf4DE2MMoEkgNf_wE03uDZ4y9JEqUMBcYCuRmjIt7bMdi6EdF_ZWFDQb0adfMhbOWqL2v9hIFFrKdQ3oN5zqg</recordid><startdate>19971101</startdate><enddate>19971101</enddate><creator>FELDMAN, J. M</creator><creator>EBRAHIM, M. H</creator><creator>BAR-KANA, I</creator><general>Little</general><general>Springer Nature B.V</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>3V.</scope><scope>7RV</scope><scope>7SC</scope><scope>7SP</scope><scope>7U5</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>JQ2</scope><scope>K7-</scope><scope>K9.</scope><scope>KB0</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>M0S</scope><scope>M1P</scope><scope>NAPCQ</scope><scope>P5Z</scope><scope>P62</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>19971101</creationdate><title>Robust sensor fusion improves heart rate estimation : Clinical evaluation</title><author>FELDMAN, J. M ; EBRAHIM, M. H ; BAR-KANA, I</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c308t-a19591fde7dac78175375564723eb32baa755a2b22af27ec624262fabd3c1dd03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Adult</topic><topic>Anesthesia</topic><topic>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</topic><topic>Anesthesia: equipment, devices</topic><topic>Biological and medical sciences</topic><topic>Child</topic><topic>Electrocardiography</topic><topic>Estimates</topic><topic>Heart Rate</topic><topic>Humans</topic><topic>Intensive Care Units</topic><topic>Medical sciences</topic><topic>Monitoring, Intraoperative</topic><topic>Monitoring, Physiologic</topic><topic>Sensors</topic><topic>Signal Processing, Computer-Assisted</topic><topic>Studies</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>FELDMAN, J. M</creatorcontrib><creatorcontrib>EBRAHIM, M. H</creatorcontrib><creatorcontrib>BAR-KANA, I</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>ProQuest Central (Corporate)</collection><collection>Nursing &amp; Allied Health Database</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Computer Science Collection</collection><collection>Computer Science Database</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>Advanced Technologies &amp; Aerospace Database</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of clinical monitoring</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>FELDMAN, J. M</au><au>EBRAHIM, M. H</au><au>BAR-KANA, I</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Robust sensor fusion improves heart rate estimation : Clinical evaluation</atitle><jtitle>Journal of clinical monitoring</jtitle><addtitle>J Clin Monit</addtitle><date>1997-11-01</date><risdate>1997</risdate><volume>13</volume><issue>6</issue><spage>379</spage><epage>384</epage><pages>379-384</pages><issn>0748-1977</issn><issn>1387-1307</issn><eissn>2214-7330</eissn><eissn>1573-2614</eissn><coden>JCMOEH</coden><abstract>To determine if Robust Sensor Fusion (RSF), a method designed to fuse data from multiple sensors with redundant heart rate information can be used to improve the quality of heart rate data. To determine if the improved estimate of heart rate can reduce the number of false and missed heart rate alarms. A total of 85 monitoring periods were investigated, 12 from the operating room, 60 from adult ICU and 13 from pediatric ICU. The operating room periods began with induction of anesthesia and ended at the completion of the anesthetic. For the ICU data, four hour blocks of time were studied. For each monitoring period, HR values were recorded at 5 second intervals or less from the ECG, SpO2 and IAC using a SpaceLabs Medical Gateway connected to a SpaceLabs Medical PC2. Fused estimates of HR were derived for every time point using RSF and all results accepted regardless of confidence value. Data were annotated manually to identify the "reference" HR (that HR value most likely to be correct) at all time points. All HR values from the sensors and the fused estimate that were different from the reference HR by more than +/- 5 beats/min were considered inaccurate. For each monitoring period, the total time per hour that data were either inaccurate or unavailable was calculated for each sensor as well as the fused estimates. The total time of false and missed HR alarms was found for all sensors and the fused estimate by comparing the data to thresholds for both high and low HR alarms at 150 bpm, 130 bpm, 110 bpm and 50 bpm, 40 bpm, 30 bpm respectively. The fused estimate of HR was consistently as good or better than the estimate available from any individual sensor. The fused estimates also consistently reduced the incidence of false alarms compared with individual sensors without an unacceptable incidence of missed alarms. Redundancy in sensor measurements can be used to improve HR estimation in the clinical setting. Methods like RSF which improve the quality of monitored data and reduce nuisance alarms will enhance the value of patient monitors to clinicians.</abstract><cop>Boston, MA</cop><pub>Little</pub><pmid>9495290</pmid><doi>10.1023/A:1007476707284</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0748-1977
ispartof Journal of clinical monitoring, 1997-11, Vol.13 (6), p.379-384
issn 0748-1977
1387-1307
2214-7330
1573-2614
language eng
recordid cdi_proquest_journals_863395295
source MEDLINE; SpringerNature Journals
subjects Adult
Anesthesia
Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy
Anesthesia: equipment, devices
Biological and medical sciences
Child
Electrocardiography
Estimates
Heart Rate
Humans
Intensive Care Units
Medical sciences
Monitoring, Intraoperative
Monitoring, Physiologic
Sensors
Signal Processing, Computer-Assisted
Studies
title Robust sensor fusion improves heart rate estimation : Clinical evaluation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T04%3A29%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Robust%20sensor%20fusion%20improves%20heart%20rate%20estimation%20:%20Clinical%20evaluation&rft.jtitle=Journal%20of%20clinical%20monitoring&rft.au=FELDMAN,%20J.%20M&rft.date=1997-11-01&rft.volume=13&rft.issue=6&rft.spage=379&rft.epage=384&rft.pages=379-384&rft.issn=0748-1977&rft.eissn=2214-7330&rft.coden=JCMOEH&rft_id=info:doi/10.1023/A:1007476707284&rft_dat=%3Cproquest_pubme%3E2329458171%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=863395295&rft_id=info:pmid/9495290&rfr_iscdi=true