Continuous Flow Electrocoagulation System for Enhanced Phosphorous Removal in Decentralized Wastewater Treatment Systems

Decentralized wastewater treatment systems (DWTS) are significant contributors to the eutrophication of surface water bodies due to a lack of treatment mechanisms that target dissolved phosphorus removal. Existing advanced treatment systems are expensive to operate, large in nature, and require freq...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Water (Basel) 2025-01, Vol.17 (2), p.202
Hauptverfasser: Hayden, James, Abbassi, Bassim
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 2
container_start_page 202
container_title Water (Basel)
container_volume 17
creator Hayden, James
Abbassi, Bassim
description Decentralized wastewater treatment systems (DWTS) are significant contributors to the eutrophication of surface water bodies due to a lack of treatment mechanisms that target dissolved phosphorus removal. Existing advanced treatment systems are expensive to operate, large in nature, and require frequent maintenance, making them unattractive to DWTS owners. This study aims to investigate the development of a continuous flow treatment system that uses electrocoagulation (EC) to remove dissolved phosphorus from small wastewater streams such as septic tank effluent (STE). Operational parameters, including system hydraulic retention time (HRT), applied current density, and wastewater composition, were optimized to maximize total phosphorus (TP) removal most cost-effectively. Using an HRT of 10 min, an applied current density of 2.0 mA/cm2, and an influent concentration of 20 mg/L, the orthophosphate (OP) and TP removal percentages achieved were 99.9 and 88.1%, respectively. Under these conditions, the average effluent Al3+ concentration in the treated effluent was measured to be 1.0 mg/L while the total suspended solids concentration was measured to be 51 mg/L. The operation cost was estimated to be 0.056 CAD/m3. The results demonstrate that the EC reactor is effective in removing dissolved phosphorus from wastewater and is therefore a viable option in mitigating the risk of downstream eutrophication caused by inadequately treated STE.
doi_str_mv 10.3390/w17020202
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_3159615651</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3159615651</sourcerecordid><originalsourceid>FETCH-LOGICAL-c621-d4f9215f582334aab2c791b59bce5423c28f6b38c746ecb0e4d4f6e9073d89273</originalsourceid><addsrcrecordid>eNpNUEtLAzEQDqJgqT34DwKePFTz3N0cpbYqFBQteFyy6azdspvUJGutv96UFnHmMAPzPZgPoUtKbjhX5HZLc8L2fYIGjOR8LISgp__2czQKYU1SCVUUkgzQ98TZ2Nje9QHPWrfF0xZM9M44_dG3OjbO4rddiNDh2nk8tSttDSzxy8qFzcr5Pe8VOvelW9xYfA8GbPS6bX4S6F0n4lZH8HjhQccu3Y5q4QKd1boNMDrOIVrMpovJ43j-_PA0uZuPTcboeClqxaisZcE4F1pXzOSKVlJVBqRg3LCizipemFxkYCoCIjEyUOnhZaFYzofo6iC78e6zhxDLteu9TY4lp1JlVGaSJtT1AWW8C8FDXW5802m_Kykp99GWf9HyX-2RbRI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3159615651</pqid></control><display><type>article</type><title>Continuous Flow Electrocoagulation System for Enhanced Phosphorous Removal in Decentralized Wastewater Treatment Systems</title><source>MDPI - Multidisciplinary Digital Publishing Institute</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Hayden, James ; Abbassi, Bassim</creator><creatorcontrib>Hayden, James ; Abbassi, Bassim</creatorcontrib><description>Decentralized wastewater treatment systems (DWTS) are significant contributors to the eutrophication of surface water bodies due to a lack of treatment mechanisms that target dissolved phosphorus removal. Existing advanced treatment systems are expensive to operate, large in nature, and require frequent maintenance, making them unattractive to DWTS owners. This study aims to investigate the development of a continuous flow treatment system that uses electrocoagulation (EC) to remove dissolved phosphorus from small wastewater streams such as septic tank effluent (STE). Operational parameters, including system hydraulic retention time (HRT), applied current density, and wastewater composition, were optimized to maximize total phosphorus (TP) removal most cost-effectively. Using an HRT of 10 min, an applied current density of 2.0 mA/cm2, and an influent concentration of 20 mg/L, the orthophosphate (OP) and TP removal percentages achieved were 99.9 and 88.1%, respectively. Under these conditions, the average effluent Al3+ concentration in the treated effluent was measured to be 1.0 mg/L while the total suspended solids concentration was measured to be 51 mg/L. The operation cost was estimated to be 0.056 CAD/m3. The results demonstrate that the EC reactor is effective in removing dissolved phosphorus from wastewater and is therefore a viable option in mitigating the risk of downstream eutrophication caused by inadequately treated STE.</description><identifier>ISSN: 2073-4441</identifier><identifier>EISSN: 2073-4441</identifier><identifier>DOI: 10.3390/w17020202</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Adsorption ; Aluminum ; Chemical oxygen demand ; Electrodes ; Eutrophication ; Phosphorus removal ; Reactors ; Water treatment</subject><ispartof>Water (Basel), 2025-01, Vol.17 (2), p.202</ispartof><rights>2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c621-d4f9215f582334aab2c791b59bce5423c28f6b38c746ecb0e4d4f6e9073d89273</cites><orcidid>0000-0002-0770-9800</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Hayden, James</creatorcontrib><creatorcontrib>Abbassi, Bassim</creatorcontrib><title>Continuous Flow Electrocoagulation System for Enhanced Phosphorous Removal in Decentralized Wastewater Treatment Systems</title><title>Water (Basel)</title><description>Decentralized wastewater treatment systems (DWTS) are significant contributors to the eutrophication of surface water bodies due to a lack of treatment mechanisms that target dissolved phosphorus removal. Existing advanced treatment systems are expensive to operate, large in nature, and require frequent maintenance, making them unattractive to DWTS owners. This study aims to investigate the development of a continuous flow treatment system that uses electrocoagulation (EC) to remove dissolved phosphorus from small wastewater streams such as septic tank effluent (STE). Operational parameters, including system hydraulic retention time (HRT), applied current density, and wastewater composition, were optimized to maximize total phosphorus (TP) removal most cost-effectively. Using an HRT of 10 min, an applied current density of 2.0 mA/cm2, and an influent concentration of 20 mg/L, the orthophosphate (OP) and TP removal percentages achieved were 99.9 and 88.1%, respectively. Under these conditions, the average effluent Al3+ concentration in the treated effluent was measured to be 1.0 mg/L while the total suspended solids concentration was measured to be 51 mg/L. The operation cost was estimated to be 0.056 CAD/m3. The results demonstrate that the EC reactor is effective in removing dissolved phosphorus from wastewater and is therefore a viable option in mitigating the risk of downstream eutrophication caused by inadequately treated STE.</description><subject>Adsorption</subject><subject>Aluminum</subject><subject>Chemical oxygen demand</subject><subject>Electrodes</subject><subject>Eutrophication</subject><subject>Phosphorus removal</subject><subject>Reactors</subject><subject>Water treatment</subject><issn>2073-4441</issn><issn>2073-4441</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2025</creationdate><recordtype>article</recordtype><sourceid>BENPR</sourceid><recordid>eNpNUEtLAzEQDqJgqT34DwKePFTz3N0cpbYqFBQteFyy6azdspvUJGutv96UFnHmMAPzPZgPoUtKbjhX5HZLc8L2fYIGjOR8LISgp__2czQKYU1SCVUUkgzQ98TZ2Nje9QHPWrfF0xZM9M44_dG3OjbO4rddiNDh2nk8tSttDSzxy8qFzcr5Pe8VOvelW9xYfA8GbPS6bX4S6F0n4lZH8HjhQccu3Y5q4QKd1boNMDrOIVrMpovJ43j-_PA0uZuPTcboeClqxaisZcE4F1pXzOSKVlJVBqRg3LCizipemFxkYCoCIjEyUOnhZaFYzofo6iC78e6zhxDLteu9TY4lp1JlVGaSJtT1AWW8C8FDXW5802m_Kykp99GWf9HyX-2RbRI</recordid><startdate>20250114</startdate><enddate>20250114</enddate><creator>Hayden, James</creator><creator>Abbassi, Bassim</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><orcidid>https://orcid.org/0000-0002-0770-9800</orcidid></search><sort><creationdate>20250114</creationdate><title>Continuous Flow Electrocoagulation System for Enhanced Phosphorous Removal in Decentralized Wastewater Treatment Systems</title><author>Hayden, James ; Abbassi, Bassim</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c621-d4f9215f582334aab2c791b59bce5423c28f6b38c746ecb0e4d4f6e9073d89273</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2025</creationdate><topic>Adsorption</topic><topic>Aluminum</topic><topic>Chemical oxygen demand</topic><topic>Electrodes</topic><topic>Eutrophication</topic><topic>Phosphorus removal</topic><topic>Reactors</topic><topic>Water treatment</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hayden, James</creatorcontrib><creatorcontrib>Abbassi, Bassim</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Water (Basel)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hayden, James</au><au>Abbassi, Bassim</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Continuous Flow Electrocoagulation System for Enhanced Phosphorous Removal in Decentralized Wastewater Treatment Systems</atitle><jtitle>Water (Basel)</jtitle><date>2025-01-14</date><risdate>2025</risdate><volume>17</volume><issue>2</issue><spage>202</spage><pages>202-</pages><issn>2073-4441</issn><eissn>2073-4441</eissn><abstract>Decentralized wastewater treatment systems (DWTS) are significant contributors to the eutrophication of surface water bodies due to a lack of treatment mechanisms that target dissolved phosphorus removal. Existing advanced treatment systems are expensive to operate, large in nature, and require frequent maintenance, making them unattractive to DWTS owners. This study aims to investigate the development of a continuous flow treatment system that uses electrocoagulation (EC) to remove dissolved phosphorus from small wastewater streams such as septic tank effluent (STE). Operational parameters, including system hydraulic retention time (HRT), applied current density, and wastewater composition, were optimized to maximize total phosphorus (TP) removal most cost-effectively. Using an HRT of 10 min, an applied current density of 2.0 mA/cm2, and an influent concentration of 20 mg/L, the orthophosphate (OP) and TP removal percentages achieved were 99.9 and 88.1%, respectively. Under these conditions, the average effluent Al3+ concentration in the treated effluent was measured to be 1.0 mg/L while the total suspended solids concentration was measured to be 51 mg/L. The operation cost was estimated to be 0.056 CAD/m3. The results demonstrate that the EC reactor is effective in removing dissolved phosphorus from wastewater and is therefore a viable option in mitigating the risk of downstream eutrophication caused by inadequately treated STE.</abstract><cop>Basel</cop><pub>MDPI AG</pub><doi>10.3390/w17020202</doi><orcidid>https://orcid.org/0000-0002-0770-9800</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2073-4441
ispartof Water (Basel), 2025-01, Vol.17 (2), p.202
issn 2073-4441
2073-4441
language eng
recordid cdi_proquest_journals_3159615651
source MDPI - Multidisciplinary Digital Publishing Institute; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Adsorption
Aluminum
Chemical oxygen demand
Electrodes
Eutrophication
Phosphorus removal
Reactors
Water treatment
title Continuous Flow Electrocoagulation System for Enhanced Phosphorous Removal in Decentralized Wastewater Treatment Systems
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T20%3A03%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Continuous%20Flow%20Electrocoagulation%20System%20for%20Enhanced%20Phosphorous%20Removal%20in%20Decentralized%20Wastewater%20Treatment%20Systems&rft.jtitle=Water%20(Basel)&rft.au=Hayden,%20James&rft.date=2025-01-14&rft.volume=17&rft.issue=2&rft.spage=202&rft.pages=202-&rft.issn=2073-4441&rft.eissn=2073-4441&rft_id=info:doi/10.3390/w17020202&rft_dat=%3Cproquest_cross%3E3159615651%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3159615651&rft_id=info:pmid/&rfr_iscdi=true