A short review on wearable sensors used in the evaluation and rehabilitation of total knee arthroplasty patients
Osteoarthritis is a condition that affects the load-bearing joints leading to functional impairment and reduced quality of life. The knee joint is the most commonly affected joint. It is a condition that progresses gradually. In the initial stages, symptomatic management can be done by conservative...
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 1 |
container_start_page | |
container_title | |
container_volume | 3188 |
creator | Fokmare, Pranali Phansopkar, Pratik Ansari, Khalid |
description | Osteoarthritis is a condition that affects the load-bearing joints leading to functional impairment and reduced quality of life. The knee joint is the most commonly affected joint. It is a condition that progresses gradually. In the initial stages, symptomatic management can be done by conservative treatment. In the severe stage, the primary treatment is total knee arthroplasty. Restricted knee flexion after TKA is a common clinical manifestation and a cause of patient dissatisfaction. Because of this, exercises are important after surgery to gain functional mobility. So, to find the effect of interventions given after TKR, the new technologies can be used to assess the outcomes. Post-TKA surgery to evaluate the range of motion and gait and to make patients exercise using wearable sensors is growing in popularity, as it is easy to use and gives accurate results and feedback to the patient when exercising. The Inertial Measurement Units are made up of a microelectromechanical system. This device collects information about the motions as it is worn on the body, and the data is stored and can be displayed in the software. This gives accurate measures of the outcomes and can be a better assessment and rehabilitation option over the traditional methods. |
doi_str_mv | 10.1063/5.0240711 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_proquest_journals_3142698449</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3142698449</sourcerecordid><originalsourceid>FETCH-LOGICAL-p631-abb91c6907db5f8c0f62530f35ad53a446097140621a960425e9970c6418054e3</originalsourceid><addsrcrecordid>eNotkE1Lw0AQhhdRsFYP_oMFb0LqbPYj2WMpfkHBSw_ewiSZkNSYjbubFv-9kfY0MDzvO8zD2L2AlQAjn_QKUgWZEBdsIbQWSWaEuWQLAKuSVMnPa3YTwh4gtVmWL9i45qF1PnJPh46O3A38SOix7IkHGoLzgU-Bat4NPLbE6YD9hLGbORzqOdVi2fVdPK1cw6OL2POvgYijj613Y48h_vJxJmiI4ZZdNdgHujvPJdu9PO82b8n24_V9s94mo5EiwbK0ojIWsrrUTV5BY1ItoZEaay1RKQM2EwpMKtAaUKkmazOojBI5aEVyyR5OtaN3PxOFWOzd5If5YiGFSo3NlbIz9XiiQnV-oRh9943-txBQ_AstdHEWKv8AUrFn8A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>3142698449</pqid></control><display><type>conference_proceeding</type><title>A short review on wearable sensors used in the evaluation and rehabilitation of total knee arthroplasty patients</title><source>American Institute of Physics (AIP) Journals</source><creator>Fokmare, Pranali ; Phansopkar, Pratik ; Ansari, Khalid</creator><contributor>Gawande, Snehal P. ; Rajguru, Vijaya S. ; Adhau, Sarala P.</contributor><creatorcontrib>Fokmare, Pranali ; Phansopkar, Pratik ; Ansari, Khalid ; Gawande, Snehal P. ; Rajguru, Vijaya S. ; Adhau, Sarala P.</creatorcontrib><description>Osteoarthritis is a condition that affects the load-bearing joints leading to functional impairment and reduced quality of life. The knee joint is the most commonly affected joint. It is a condition that progresses gradually. In the initial stages, symptomatic management can be done by conservative treatment. In the severe stage, the primary treatment is total knee arthroplasty. Restricted knee flexion after TKA is a common clinical manifestation and a cause of patient dissatisfaction. Because of this, exercises are important after surgery to gain functional mobility. So, to find the effect of interventions given after TKR, the new technologies can be used to assess the outcomes. Post-TKA surgery to evaluate the range of motion and gait and to make patients exercise using wearable sensors is growing in popularity, as it is easy to use and gives accurate results and feedback to the patient when exercising. The Inertial Measurement Units are made up of a microelectromechanical system. This device collects information about the motions as it is worn on the body, and the data is stored and can be displayed in the software. This gives accurate measures of the outcomes and can be a better assessment and rehabilitation option over the traditional methods.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/5.0240711</identifier><identifier>CODEN: APCPCS</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Evaluation ; Inertial platforms ; Inertial sensing devices ; Joint replacement surgery ; Knee ; Microelectromechanical systems ; Orthopaedic implants ; Rehabilitation ; Surgery ; Wearable technology</subject><ispartof>AIP conference proceedings, 2024, Vol.3188 (1)</ispartof><rights>Author(s)</rights><rights>2024 Author(s). Published under an exclusive license by AIP Publishing.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/acp/article-lookup/doi/10.1063/5.0240711$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,794,4512,23930,23931,25140,27924,27925,76384</link.rule.ids></links><search><contributor>Gawande, Snehal P.</contributor><contributor>Rajguru, Vijaya S.</contributor><contributor>Adhau, Sarala P.</contributor><creatorcontrib>Fokmare, Pranali</creatorcontrib><creatorcontrib>Phansopkar, Pratik</creatorcontrib><creatorcontrib>Ansari, Khalid</creatorcontrib><title>A short review on wearable sensors used in the evaluation and rehabilitation of total knee arthroplasty patients</title><title>AIP conference proceedings</title><description>Osteoarthritis is a condition that affects the load-bearing joints leading to functional impairment and reduced quality of life. The knee joint is the most commonly affected joint. It is a condition that progresses gradually. In the initial stages, symptomatic management can be done by conservative treatment. In the severe stage, the primary treatment is total knee arthroplasty. Restricted knee flexion after TKA is a common clinical manifestation and a cause of patient dissatisfaction. Because of this, exercises are important after surgery to gain functional mobility. So, to find the effect of interventions given after TKR, the new technologies can be used to assess the outcomes. Post-TKA surgery to evaluate the range of motion and gait and to make patients exercise using wearable sensors is growing in popularity, as it is easy to use and gives accurate results and feedback to the patient when exercising. The Inertial Measurement Units are made up of a microelectromechanical system. This device collects information about the motions as it is worn on the body, and the data is stored and can be displayed in the software. This gives accurate measures of the outcomes and can be a better assessment and rehabilitation option over the traditional methods.</description><subject>Evaluation</subject><subject>Inertial platforms</subject><subject>Inertial sensing devices</subject><subject>Joint replacement surgery</subject><subject>Knee</subject><subject>Microelectromechanical systems</subject><subject>Orthopaedic implants</subject><subject>Rehabilitation</subject><subject>Surgery</subject><subject>Wearable technology</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2024</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNotkE1Lw0AQhhdRsFYP_oMFb0LqbPYj2WMpfkHBSw_ewiSZkNSYjbubFv-9kfY0MDzvO8zD2L2AlQAjn_QKUgWZEBdsIbQWSWaEuWQLAKuSVMnPa3YTwh4gtVmWL9i45qF1PnJPh46O3A38SOix7IkHGoLzgU-Bat4NPLbE6YD9hLGbORzqOdVi2fVdPK1cw6OL2POvgYijj613Y48h_vJxJmiI4ZZdNdgHujvPJdu9PO82b8n24_V9s94mo5EiwbK0ojIWsrrUTV5BY1ItoZEaay1RKQM2EwpMKtAaUKkmazOojBI5aEVyyR5OtaN3PxOFWOzd5If5YiGFSo3NlbIz9XiiQnV-oRh9943-txBQ_AstdHEWKv8AUrFn8A</recordid><startdate>20241210</startdate><enddate>20241210</enddate><creator>Fokmare, Pranali</creator><creator>Phansopkar, Pratik</creator><creator>Ansari, Khalid</creator><general>American Institute of Physics</general><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20241210</creationdate><title>A short review on wearable sensors used in the evaluation and rehabilitation of total knee arthroplasty patients</title><author>Fokmare, Pranali ; Phansopkar, Pratik ; Ansari, Khalid</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p631-abb91c6907db5f8c0f62530f35ad53a446097140621a960425e9970c6418054e3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Evaluation</topic><topic>Inertial platforms</topic><topic>Inertial sensing devices</topic><topic>Joint replacement surgery</topic><topic>Knee</topic><topic>Microelectromechanical systems</topic><topic>Orthopaedic implants</topic><topic>Rehabilitation</topic><topic>Surgery</topic><topic>Wearable technology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fokmare, Pranali</creatorcontrib><creatorcontrib>Phansopkar, Pratik</creatorcontrib><creatorcontrib>Ansari, Khalid</creatorcontrib><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fokmare, Pranali</au><au>Phansopkar, Pratik</au><au>Ansari, Khalid</au><au>Gawande, Snehal P.</au><au>Rajguru, Vijaya S.</au><au>Adhau, Sarala P.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A short review on wearable sensors used in the evaluation and rehabilitation of total knee arthroplasty patients</atitle><btitle>AIP conference proceedings</btitle><date>2024-12-10</date><risdate>2024</risdate><volume>3188</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><coden>APCPCS</coden><abstract>Osteoarthritis is a condition that affects the load-bearing joints leading to functional impairment and reduced quality of life. The knee joint is the most commonly affected joint. It is a condition that progresses gradually. In the initial stages, symptomatic management can be done by conservative treatment. In the severe stage, the primary treatment is total knee arthroplasty. Restricted knee flexion after TKA is a common clinical manifestation and a cause of patient dissatisfaction. Because of this, exercises are important after surgery to gain functional mobility. So, to find the effect of interventions given after TKR, the new technologies can be used to assess the outcomes. Post-TKA surgery to evaluate the range of motion and gait and to make patients exercise using wearable sensors is growing in popularity, as it is easy to use and gives accurate results and feedback to the patient when exercising. The Inertial Measurement Units are made up of a microelectromechanical system. This device collects information about the motions as it is worn on the body, and the data is stored and can be displayed in the software. This gives accurate measures of the outcomes and can be a better assessment and rehabilitation option over the traditional methods.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/5.0240711</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0094-243X |
ispartof | AIP conference proceedings, 2024, Vol.3188 (1) |
issn | 0094-243X 1551-7616 |
language | eng |
recordid | cdi_proquest_journals_3142698449 |
source | American Institute of Physics (AIP) Journals |
subjects | Evaluation Inertial platforms Inertial sensing devices Joint replacement surgery Knee Microelectromechanical systems Orthopaedic implants Rehabilitation Surgery Wearable technology |
title | A short review on wearable sensors used in the evaluation and rehabilitation of total knee arthroplasty patients |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T07%3A38%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20short%20review%20on%20wearable%20sensors%20used%20in%20the%20evaluation%20and%20rehabilitation%20of%20total%20knee%20arthroplasty%20patients&rft.btitle=AIP%20conference%20proceedings&rft.au=Fokmare,%20Pranali&rft.date=2024-12-10&rft.volume=3188&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft.coden=APCPCS&rft_id=info:doi/10.1063/5.0240711&rft_dat=%3Cproquest_scita%3E3142698449%3C/proquest_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3142698449&rft_id=info:pmid/&rfr_iscdi=true |