A short review on wearable sensors used in the evaluation and rehabilitation of total knee arthroplasty patients

Osteoarthritis is a condition that affects the load-bearing joints leading to functional impairment and reduced quality of life. The knee joint is the most commonly affected joint. It is a condition that progresses gradually. In the initial stages, symptomatic management can be done by conservative...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Fokmare, Pranali, Phansopkar, Pratik, Ansari, Khalid
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page
container_title
container_volume 3188
creator Fokmare, Pranali
Phansopkar, Pratik
Ansari, Khalid
description Osteoarthritis is a condition that affects the load-bearing joints leading to functional impairment and reduced quality of life. The knee joint is the most commonly affected joint. It is a condition that progresses gradually. In the initial stages, symptomatic management can be done by conservative treatment. In the severe stage, the primary treatment is total knee arthroplasty. Restricted knee flexion after TKA is a common clinical manifestation and a cause of patient dissatisfaction. Because of this, exercises are important after surgery to gain functional mobility. So, to find the effect of interventions given after TKR, the new technologies can be used to assess the outcomes. Post-TKA surgery to evaluate the range of motion and gait and to make patients exercise using wearable sensors is growing in popularity, as it is easy to use and gives accurate results and feedback to the patient when exercising. The Inertial Measurement Units are made up of a microelectromechanical system. This device collects information about the motions as it is worn on the body, and the data is stored and can be displayed in the software. This gives accurate measures of the outcomes and can be a better assessment and rehabilitation option over the traditional methods.
doi_str_mv 10.1063/5.0240711
format Conference Proceeding
fullrecord <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_proquest_journals_3142698449</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3142698449</sourcerecordid><originalsourceid>FETCH-LOGICAL-p631-abb91c6907db5f8c0f62530f35ad53a446097140621a960425e9970c6418054e3</originalsourceid><addsrcrecordid>eNotkE1Lw0AQhhdRsFYP_oMFb0LqbPYj2WMpfkHBSw_ewiSZkNSYjbubFv-9kfY0MDzvO8zD2L2AlQAjn_QKUgWZEBdsIbQWSWaEuWQLAKuSVMnPa3YTwh4gtVmWL9i45qF1PnJPh46O3A38SOix7IkHGoLzgU-Bat4NPLbE6YD9hLGbORzqOdVi2fVdPK1cw6OL2POvgYijj613Y48h_vJxJmiI4ZZdNdgHujvPJdu9PO82b8n24_V9s94mo5EiwbK0ojIWsrrUTV5BY1ItoZEaay1RKQM2EwpMKtAaUKkmazOojBI5aEVyyR5OtaN3PxOFWOzd5If5YiGFSo3NlbIz9XiiQnV-oRh9943-txBQ_AstdHEWKv8AUrFn8A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>3142698449</pqid></control><display><type>conference_proceeding</type><title>A short review on wearable sensors used in the evaluation and rehabilitation of total knee arthroplasty patients</title><source>American Institute of Physics (AIP) Journals</source><creator>Fokmare, Pranali ; Phansopkar, Pratik ; Ansari, Khalid</creator><contributor>Gawande, Snehal P. ; Rajguru, Vijaya S. ; Adhau, Sarala P.</contributor><creatorcontrib>Fokmare, Pranali ; Phansopkar, Pratik ; Ansari, Khalid ; Gawande, Snehal P. ; Rajguru, Vijaya S. ; Adhau, Sarala P.</creatorcontrib><description>Osteoarthritis is a condition that affects the load-bearing joints leading to functional impairment and reduced quality of life. The knee joint is the most commonly affected joint. It is a condition that progresses gradually. In the initial stages, symptomatic management can be done by conservative treatment. In the severe stage, the primary treatment is total knee arthroplasty. Restricted knee flexion after TKA is a common clinical manifestation and a cause of patient dissatisfaction. Because of this, exercises are important after surgery to gain functional mobility. So, to find the effect of interventions given after TKR, the new technologies can be used to assess the outcomes. Post-TKA surgery to evaluate the range of motion and gait and to make patients exercise using wearable sensors is growing in popularity, as it is easy to use and gives accurate results and feedback to the patient when exercising. The Inertial Measurement Units are made up of a microelectromechanical system. This device collects information about the motions as it is worn on the body, and the data is stored and can be displayed in the software. This gives accurate measures of the outcomes and can be a better assessment and rehabilitation option over the traditional methods.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/5.0240711</identifier><identifier>CODEN: APCPCS</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Evaluation ; Inertial platforms ; Inertial sensing devices ; Joint replacement surgery ; Knee ; Microelectromechanical systems ; Orthopaedic implants ; Rehabilitation ; Surgery ; Wearable technology</subject><ispartof>AIP conference proceedings, 2024, Vol.3188 (1)</ispartof><rights>Author(s)</rights><rights>2024 Author(s). Published under an exclusive license by AIP Publishing.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/acp/article-lookup/doi/10.1063/5.0240711$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,794,4512,23930,23931,25140,27924,27925,76384</link.rule.ids></links><search><contributor>Gawande, Snehal P.</contributor><contributor>Rajguru, Vijaya S.</contributor><contributor>Adhau, Sarala P.</contributor><creatorcontrib>Fokmare, Pranali</creatorcontrib><creatorcontrib>Phansopkar, Pratik</creatorcontrib><creatorcontrib>Ansari, Khalid</creatorcontrib><title>A short review on wearable sensors used in the evaluation and rehabilitation of total knee arthroplasty patients</title><title>AIP conference proceedings</title><description>Osteoarthritis is a condition that affects the load-bearing joints leading to functional impairment and reduced quality of life. The knee joint is the most commonly affected joint. It is a condition that progresses gradually. In the initial stages, symptomatic management can be done by conservative treatment. In the severe stage, the primary treatment is total knee arthroplasty. Restricted knee flexion after TKA is a common clinical manifestation and a cause of patient dissatisfaction. Because of this, exercises are important after surgery to gain functional mobility. So, to find the effect of interventions given after TKR, the new technologies can be used to assess the outcomes. Post-TKA surgery to evaluate the range of motion and gait and to make patients exercise using wearable sensors is growing in popularity, as it is easy to use and gives accurate results and feedback to the patient when exercising. The Inertial Measurement Units are made up of a microelectromechanical system. This device collects information about the motions as it is worn on the body, and the data is stored and can be displayed in the software. This gives accurate measures of the outcomes and can be a better assessment and rehabilitation option over the traditional methods.</description><subject>Evaluation</subject><subject>Inertial platforms</subject><subject>Inertial sensing devices</subject><subject>Joint replacement surgery</subject><subject>Knee</subject><subject>Microelectromechanical systems</subject><subject>Orthopaedic implants</subject><subject>Rehabilitation</subject><subject>Surgery</subject><subject>Wearable technology</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2024</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNotkE1Lw0AQhhdRsFYP_oMFb0LqbPYj2WMpfkHBSw_ewiSZkNSYjbubFv-9kfY0MDzvO8zD2L2AlQAjn_QKUgWZEBdsIbQWSWaEuWQLAKuSVMnPa3YTwh4gtVmWL9i45qF1PnJPh46O3A38SOix7IkHGoLzgU-Bat4NPLbE6YD9hLGbORzqOdVi2fVdPK1cw6OL2POvgYijj613Y48h_vJxJmiI4ZZdNdgHujvPJdu9PO82b8n24_V9s94mo5EiwbK0ojIWsrrUTV5BY1ItoZEaay1RKQM2EwpMKtAaUKkmazOojBI5aEVyyR5OtaN3PxOFWOzd5If5YiGFSo3NlbIz9XiiQnV-oRh9943-txBQ_AstdHEWKv8AUrFn8A</recordid><startdate>20241210</startdate><enddate>20241210</enddate><creator>Fokmare, Pranali</creator><creator>Phansopkar, Pratik</creator><creator>Ansari, Khalid</creator><general>American Institute of Physics</general><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20241210</creationdate><title>A short review on wearable sensors used in the evaluation and rehabilitation of total knee arthroplasty patients</title><author>Fokmare, Pranali ; Phansopkar, Pratik ; Ansari, Khalid</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p631-abb91c6907db5f8c0f62530f35ad53a446097140621a960425e9970c6418054e3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Evaluation</topic><topic>Inertial platforms</topic><topic>Inertial sensing devices</topic><topic>Joint replacement surgery</topic><topic>Knee</topic><topic>Microelectromechanical systems</topic><topic>Orthopaedic implants</topic><topic>Rehabilitation</topic><topic>Surgery</topic><topic>Wearable technology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fokmare, Pranali</creatorcontrib><creatorcontrib>Phansopkar, Pratik</creatorcontrib><creatorcontrib>Ansari, Khalid</creatorcontrib><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fokmare, Pranali</au><au>Phansopkar, Pratik</au><au>Ansari, Khalid</au><au>Gawande, Snehal P.</au><au>Rajguru, Vijaya S.</au><au>Adhau, Sarala P.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>A short review on wearable sensors used in the evaluation and rehabilitation of total knee arthroplasty patients</atitle><btitle>AIP conference proceedings</btitle><date>2024-12-10</date><risdate>2024</risdate><volume>3188</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><coden>APCPCS</coden><abstract>Osteoarthritis is a condition that affects the load-bearing joints leading to functional impairment and reduced quality of life. The knee joint is the most commonly affected joint. It is a condition that progresses gradually. In the initial stages, symptomatic management can be done by conservative treatment. In the severe stage, the primary treatment is total knee arthroplasty. Restricted knee flexion after TKA is a common clinical manifestation and a cause of patient dissatisfaction. Because of this, exercises are important after surgery to gain functional mobility. So, to find the effect of interventions given after TKR, the new technologies can be used to assess the outcomes. Post-TKA surgery to evaluate the range of motion and gait and to make patients exercise using wearable sensors is growing in popularity, as it is easy to use and gives accurate results and feedback to the patient when exercising. The Inertial Measurement Units are made up of a microelectromechanical system. This device collects information about the motions as it is worn on the body, and the data is stored and can be displayed in the software. This gives accurate measures of the outcomes and can be a better assessment and rehabilitation option over the traditional methods.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/5.0240711</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-243X
ispartof AIP conference proceedings, 2024, Vol.3188 (1)
issn 0094-243X
1551-7616
language eng
recordid cdi_proquest_journals_3142698449
source American Institute of Physics (AIP) Journals
subjects Evaluation
Inertial platforms
Inertial sensing devices
Joint replacement surgery
Knee
Microelectromechanical systems
Orthopaedic implants
Rehabilitation
Surgery
Wearable technology
title A short review on wearable sensors used in the evaluation and rehabilitation of total knee arthroplasty patients
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T07%3A38%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=A%20short%20review%20on%20wearable%20sensors%20used%20in%20the%20evaluation%20and%20rehabilitation%20of%20total%20knee%20arthroplasty%20patients&rft.btitle=AIP%20conference%20proceedings&rft.au=Fokmare,%20Pranali&rft.date=2024-12-10&rft.volume=3188&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft.coden=APCPCS&rft_id=info:doi/10.1063/5.0240711&rft_dat=%3Cproquest_scita%3E3142698449%3C/proquest_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3142698449&rft_id=info:pmid/&rfr_iscdi=true