Loading Properties of Capillary Porous-Layer Columns of Different Diameters with a Silica Gel Sorbent

The effect of the diameter of a capillary porous-layer column with a silica gel sorbent on the loading properties was studied. Three columns with diameters of 0.25, 0.32, and 0.53 mm with a regularly porous silica gel sorbent were prepared. The loading capacity of the column with a regularly porous...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Russian Journal of Physical Chemistry A 2024-10, Vol.98 (10), p.2340-2345
Hauptverfasser: Patrushev, Yu. V., Khamidov, Zh. Kh
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2345
container_issue 10
container_start_page 2340
container_title Russian Journal of Physical Chemistry A
container_volume 98
creator Patrushev, Yu. V.
Khamidov, Zh. Kh
description The effect of the diameter of a capillary porous-layer column with a silica gel sorbent on the loading properties was studied. Three columns with diameters of 0.25, 0.32, and 0.53 mm with a regularly porous silica gel sorbent were prepared. The loading capacity of the column with a regularly porous sorbent with a diameter of 0.32 mm was 7.3 times higher than for a commercial GS-GasPro column of the same diameter. The influence of the amount of the injected sample on the resolution of chromatographic peaks was shown using the separation of C 4 aliphatic hydrocarbons as an example.
doi_str_mv 10.1134/S0036024424701504
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_3103414981</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3103414981</sourcerecordid><originalsourceid>FETCH-LOGICAL-c198t-92ba9682a0958807e02194545b122fc91744cc06db56e4de8979a6b9b3080fab3</originalsourceid><addsrcrecordid>eNp1kE9Lw0AQxRdRsFY_gLcFz9HZP0l2jxK1CgELVfAWNumkbkmzcTdF-u3dWsGDeJqB-b03vEfIJYNrxoS8WQCIDLiUXObAUpBHZMJSwRKVibdjMtmfk_39lJyFsAaQUjI5IVg6s7T9is69G9CPFgN1LS3MYLvO-B2dO--2ISnNDj0tXLfd9N_EnW1b9NiPcTMbHNEH-mnHd2rowna2MXSGHV04X0fmnJy0pgt48TOn5PXh_qV4TMrn2VNxWyYN02pMNK-NzhQ3oFOlIEfgTMtUpjXjvG00y6VsGsiWdZqhXKLSuTZZrWsBClpTiym5OvgO3n1sMYzV2m19H19WgoGIibVikWIHqvEuBI9tNXi7iWErBtW-zepPm1HDD5oQ2X6F_tf5f9EXs7R1XQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3103414981</pqid></control><display><type>article</type><title>Loading Properties of Capillary Porous-Layer Columns of Different Diameters with a Silica Gel Sorbent</title><source>Springer Nature - Complete Springer Journals</source><creator>Patrushev, Yu. V. ; Khamidov, Zh. Kh</creator><creatorcontrib>Patrushev, Yu. V. ; Khamidov, Zh. Kh</creatorcontrib><description>The effect of the diameter of a capillary porous-layer column with a silica gel sorbent on the loading properties was studied. Three columns with diameters of 0.25, 0.32, and 0.53 mm with a regularly porous silica gel sorbent were prepared. The loading capacity of the column with a regularly porous sorbent with a diameter of 0.32 mm was 7.3 times higher than for a commercial GS-GasPro column of the same diameter. The influence of the amount of the injected sample on the resolution of chromatographic peaks was shown using the separation of C 4 aliphatic hydrocarbons as an example.</description><identifier>ISSN: 0036-0244</identifier><identifier>EISSN: 1531-863X</identifier><identifier>DOI: 10.1134/S0036024424701504</identifier><language>eng</language><publisher>Moscow: Pleiades Publishing</publisher><subject>Aliphatic hydrocarbons ; Chemistry ; Chemistry and Materials Science ; Physical Chemistry ; Physical Chemistry of Separation Processes. Chromatography ; Silica gel ; Sorbents</subject><ispartof>Russian Journal of Physical Chemistry A, 2024-10, Vol.98 (10), p.2340-2345</ispartof><rights>Pleiades Publishing, Ltd. 2024. ISSN 0036-0244, Russian Journal of Physical Chemistry A, 2024, Vol. 98, No. 10, pp. 2340–2345. © Pleiades Publishing, Ltd., 2024.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c198t-92ba9682a0958807e02194545b122fc91744cc06db56e4de8979a6b9b3080fab3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1134/S0036024424701504$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1134/S0036024424701504$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,776,780,27903,27904,41467,42536,51298</link.rule.ids></links><search><creatorcontrib>Patrushev, Yu. V.</creatorcontrib><creatorcontrib>Khamidov, Zh. Kh</creatorcontrib><title>Loading Properties of Capillary Porous-Layer Columns of Different Diameters with a Silica Gel Sorbent</title><title>Russian Journal of Physical Chemistry A</title><addtitle>Russ. J. Phys. Chem</addtitle><description>The effect of the diameter of a capillary porous-layer column with a silica gel sorbent on the loading properties was studied. Three columns with diameters of 0.25, 0.32, and 0.53 mm with a regularly porous silica gel sorbent were prepared. The loading capacity of the column with a regularly porous sorbent with a diameter of 0.32 mm was 7.3 times higher than for a commercial GS-GasPro column of the same diameter. The influence of the amount of the injected sample on the resolution of chromatographic peaks was shown using the separation of C 4 aliphatic hydrocarbons as an example.</description><subject>Aliphatic hydrocarbons</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Physical Chemistry</subject><subject>Physical Chemistry of Separation Processes. Chromatography</subject><subject>Silica gel</subject><subject>Sorbents</subject><issn>0036-0244</issn><issn>1531-863X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp1kE9Lw0AQxRdRsFY_gLcFz9HZP0l2jxK1CgELVfAWNumkbkmzcTdF-u3dWsGDeJqB-b03vEfIJYNrxoS8WQCIDLiUXObAUpBHZMJSwRKVibdjMtmfk_39lJyFsAaQUjI5IVg6s7T9is69G9CPFgN1LS3MYLvO-B2dO--2ISnNDj0tXLfd9N_EnW1b9NiPcTMbHNEH-mnHd2rowna2MXSGHV04X0fmnJy0pgt48TOn5PXh_qV4TMrn2VNxWyYN02pMNK-NzhQ3oFOlIEfgTMtUpjXjvG00y6VsGsiWdZqhXKLSuTZZrWsBClpTiym5OvgO3n1sMYzV2m19H19WgoGIibVikWIHqvEuBI9tNXi7iWErBtW-zepPm1HDD5oQ2X6F_tf5f9EXs7R1XQ</recordid><startdate>20241001</startdate><enddate>20241001</enddate><creator>Patrushev, Yu. V.</creator><creator>Khamidov, Zh. Kh</creator><general>Pleiades Publishing</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20241001</creationdate><title>Loading Properties of Capillary Porous-Layer Columns of Different Diameters with a Silica Gel Sorbent</title><author>Patrushev, Yu. V. ; Khamidov, Zh. Kh</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c198t-92ba9682a0958807e02194545b122fc91744cc06db56e4de8979a6b9b3080fab3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Aliphatic hydrocarbons</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Physical Chemistry</topic><topic>Physical Chemistry of Separation Processes. Chromatography</topic><topic>Silica gel</topic><topic>Sorbents</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Patrushev, Yu. V.</creatorcontrib><creatorcontrib>Khamidov, Zh. Kh</creatorcontrib><collection>CrossRef</collection><jtitle>Russian Journal of Physical Chemistry A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Patrushev, Yu. V.</au><au>Khamidov, Zh. Kh</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Loading Properties of Capillary Porous-Layer Columns of Different Diameters with a Silica Gel Sorbent</atitle><jtitle>Russian Journal of Physical Chemistry A</jtitle><stitle>Russ. J. Phys. Chem</stitle><date>2024-10-01</date><risdate>2024</risdate><volume>98</volume><issue>10</issue><spage>2340</spage><epage>2345</epage><pages>2340-2345</pages><issn>0036-0244</issn><eissn>1531-863X</eissn><abstract>The effect of the diameter of a capillary porous-layer column with a silica gel sorbent on the loading properties was studied. Three columns with diameters of 0.25, 0.32, and 0.53 mm with a regularly porous silica gel sorbent were prepared. The loading capacity of the column with a regularly porous sorbent with a diameter of 0.32 mm was 7.3 times higher than for a commercial GS-GasPro column of the same diameter. The influence of the amount of the injected sample on the resolution of chromatographic peaks was shown using the separation of C 4 aliphatic hydrocarbons as an example.</abstract><cop>Moscow</cop><pub>Pleiades Publishing</pub><doi>10.1134/S0036024424701504</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0036-0244
ispartof Russian Journal of Physical Chemistry A, 2024-10, Vol.98 (10), p.2340-2345
issn 0036-0244
1531-863X
language eng
recordid cdi_proquest_journals_3103414981
source Springer Nature - Complete Springer Journals
subjects Aliphatic hydrocarbons
Chemistry
Chemistry and Materials Science
Physical Chemistry
Physical Chemistry of Separation Processes. Chromatography
Silica gel
Sorbents
title Loading Properties of Capillary Porous-Layer Columns of Different Diameters with a Silica Gel Sorbent
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T23%3A25%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Loading%20Properties%20of%20Capillary%20Porous-Layer%20Columns%20of%20Different%20Diameters%20with%20a%20Silica%20Gel%20Sorbent&rft.jtitle=Russian%20Journal%20of%20Physical%20Chemistry%20A&rft.au=Patrushev,%20Yu.%20V.&rft.date=2024-10-01&rft.volume=98&rft.issue=10&rft.spage=2340&rft.epage=2345&rft.pages=2340-2345&rft.issn=0036-0244&rft.eissn=1531-863X&rft_id=info:doi/10.1134/S0036024424701504&rft_dat=%3Cproquest_cross%3E3103414981%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3103414981&rft_id=info:pmid/&rfr_iscdi=true