Development of a mobile eye care services in integrated home-based medical care
Background:Many homebound older adults suffered from vision-impairing eye condition in Taiwan. We constructed a mobile eye care services in integrated home-based medical care and evaluated the efficacy of the portable fundus camera in detecting diabetic retinopathy at home.Methods:We built a novel p...
Gespeichert in:
Veröffentlicht in: | International journal of integrated care 2021-09, Vol.21 (S1), p.183 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | S1 |
container_start_page | 183 |
container_title | International journal of integrated care |
container_volume | 21 |
creator | Woung, Lin-Chung |
description | Background:Many homebound older adults suffered from vision-impairing eye condition in Taiwan. We constructed a mobile eye care services in integrated home-based medical care and evaluated the efficacy of the portable fundus camera in detecting diabetic retinopathy at home.Methods:We built a novel portable handheld non-mydriatic fundus camera with telemedicine system. The image qualities of fundus cameras taken by ophthalmologists and non-ophthalmologists were compared to each other by taking photographs of 112 eyes from the 56 diabetic patients. In all 224 fundus images taken were graded with the three image clarity classifications.Results:Using the portable fundus camera by non-ophthalmologists, 65.2% (146/224) images were graded as excellent overall quality, 29.9% (67/224) were fair, and 4.9% (11/224) were inadequate. Using the portable fundus camera by ophthalmologists, 71.0% (159/224) images were graded as excellent overall quality, 25.4% (57/224) were fair, and 3.6% (8/224) were inadequate. Diabetic retinopathy was easily and accurately identified from fundus images obtained from the portable fundus camera, even in home visit by non-ophthalmologists.Conclusion:The mobile eye care services with a non-mydriatic portable fundus camera in integrated home-based medical care was qualified to have professional quality of fundus images. It will provide a foundational platform, which can potentially improve the accessibility of diabetic screening programs |
doi_str_mv | 10.5334/ijic.ICIC20203 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_3100586851</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3100586851</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1073-73ab1ab6f7f98f10793e7f155a6cf1742015112130f3df89d309eda30aafe7003</originalsourceid><addsrcrecordid>eNpNkM1LAzEQxYMoWKtXzwHPWyebZj-Osn4VCr3oOcxmJ5qy29RkW-h_b2pFhGHmMTzmMT_GbgXMlJTze7d2ZrZoFk0OOcgzNhGqqLJ56uf_9CW7inENkBeqKiZs9Uh76v12oM3IveXIB9-6njgdiBsMxCOFvTMUudukGukj4Egd__QDZS3GJAfqnMH-x37NLiz2kW5-55S9Pz-9Na_ZcvWyaB6WmRFQyqyU2ApsC1vaurJpVUsqrVAKC2NFOc9BKCFyIcHKzlZ1J6GmDiUgWioB5JTdne5ug__aURz12u_CJkVqKQDSb5USyTU7uUzwMQayehvcgOGgBegjNH2Epv-gyW88al9r</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3100586851</pqid></control><display><type>article</type><title>Development of a mobile eye care services in integrated home-based medical care</title><source>Uopen Journals</source><source>DOAJ Directory of Open Access Journals</source><source>Ubiquity Partner Network Journals (Open Access)</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>PubMed Central Open Access</source><creator>Woung, Lin-Chung</creator><creatorcontrib>Woung, Lin-Chung</creatorcontrib><description>Background:Many homebound older adults suffered from vision-impairing eye condition in Taiwan. We constructed a mobile eye care services in integrated home-based medical care and evaluated the efficacy of the portable fundus camera in detecting diabetic retinopathy at home.Methods:We built a novel portable handheld non-mydriatic fundus camera with telemedicine system. The image qualities of fundus cameras taken by ophthalmologists and non-ophthalmologists were compared to each other by taking photographs of 112 eyes from the 56 diabetic patients. In all 224 fundus images taken were graded with the three image clarity classifications.Results:Using the portable fundus camera by non-ophthalmologists, 65.2% (146/224) images were graded as excellent overall quality, 29.9% (67/224) were fair, and 4.9% (11/224) were inadequate. Using the portable fundus camera by ophthalmologists, 71.0% (159/224) images were graded as excellent overall quality, 25.4% (57/224) were fair, and 3.6% (8/224) were inadequate. Diabetic retinopathy was easily and accurately identified from fundus images obtained from the portable fundus camera, even in home visit by non-ophthalmologists.Conclusion:The mobile eye care services with a non-mydriatic portable fundus camera in integrated home-based medical care was qualified to have professional quality of fundus images. It will provide a foundational platform, which can potentially improve the accessibility of diabetic screening programs</description><identifier>ISSN: 1568-4156</identifier><identifier>EISSN: 1568-4156</identifier><identifier>DOI: 10.5334/ijic.ICIC20203</identifier><language>eng</language><publisher>Paterna: Ubiquity Press</publisher><subject>Cameras ; Diabetes ; Diabetic retinopathy ; Medical personnel</subject><ispartof>International journal of integrated care, 2021-09, Vol.21 (S1), p.183</ispartof><rights>2020. This work is published under https://creativecommons.org/licenses/by/4.0 (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,27901,27902</link.rule.ids></links><search><creatorcontrib>Woung, Lin-Chung</creatorcontrib><title>Development of a mobile eye care services in integrated home-based medical care</title><title>International journal of integrated care</title><description>Background:Many homebound older adults suffered from vision-impairing eye condition in Taiwan. We constructed a mobile eye care services in integrated home-based medical care and evaluated the efficacy of the portable fundus camera in detecting diabetic retinopathy at home.Methods:We built a novel portable handheld non-mydriatic fundus camera with telemedicine system. The image qualities of fundus cameras taken by ophthalmologists and non-ophthalmologists were compared to each other by taking photographs of 112 eyes from the 56 diabetic patients. In all 224 fundus images taken were graded with the three image clarity classifications.Results:Using the portable fundus camera by non-ophthalmologists, 65.2% (146/224) images were graded as excellent overall quality, 29.9% (67/224) were fair, and 4.9% (11/224) were inadequate. Using the portable fundus camera by ophthalmologists, 71.0% (159/224) images were graded as excellent overall quality, 25.4% (57/224) were fair, and 3.6% (8/224) were inadequate. Diabetic retinopathy was easily and accurately identified from fundus images obtained from the portable fundus camera, even in home visit by non-ophthalmologists.Conclusion:The mobile eye care services with a non-mydriatic portable fundus camera in integrated home-based medical care was qualified to have professional quality of fundus images. It will provide a foundational platform, which can potentially improve the accessibility of diabetic screening programs</description><subject>Cameras</subject><subject>Diabetes</subject><subject>Diabetic retinopathy</subject><subject>Medical personnel</subject><issn>1568-4156</issn><issn>1568-4156</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>BENPR</sourceid><recordid>eNpNkM1LAzEQxYMoWKtXzwHPWyebZj-Osn4VCr3oOcxmJ5qy29RkW-h_b2pFhGHmMTzmMT_GbgXMlJTze7d2ZrZoFk0OOcgzNhGqqLJ56uf_9CW7inENkBeqKiZs9Uh76v12oM3IveXIB9-6njgdiBsMxCOFvTMUudukGukj4Egd__QDZS3GJAfqnMH-x37NLiz2kW5-55S9Pz-9Na_ZcvWyaB6WmRFQyqyU2ApsC1vaurJpVUsqrVAKC2NFOc9BKCFyIcHKzlZ1J6GmDiUgWioB5JTdne5ug__aURz12u_CJkVqKQDSb5USyTU7uUzwMQayehvcgOGgBegjNH2Epv-gyW88al9r</recordid><startdate>20210901</startdate><enddate>20210901</enddate><creator>Woung, Lin-Chung</creator><general>Ubiquity Press</general><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88C</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>M0T</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope></search><sort><creationdate>20210901</creationdate><title>Development of a mobile eye care services in integrated home-based medical care</title><author>Woung, Lin-Chung</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1073-73ab1ab6f7f98f10793e7f155a6cf1742015112130f3df89d309eda30aafe7003</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Cameras</topic><topic>Diabetes</topic><topic>Diabetic retinopathy</topic><topic>Medical personnel</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Woung, Lin-Chung</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Healthcare Administration Database (Alumni)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Healthcare Administration Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><jtitle>International journal of integrated care</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Woung, Lin-Chung</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of a mobile eye care services in integrated home-based medical care</atitle><jtitle>International journal of integrated care</jtitle><date>2021-09-01</date><risdate>2021</risdate><volume>21</volume><issue>S1</issue><spage>183</spage><pages>183-</pages><issn>1568-4156</issn><eissn>1568-4156</eissn><abstract>Background:Many homebound older adults suffered from vision-impairing eye condition in Taiwan. We constructed a mobile eye care services in integrated home-based medical care and evaluated the efficacy of the portable fundus camera in detecting diabetic retinopathy at home.Methods:We built a novel portable handheld non-mydriatic fundus camera with telemedicine system. The image qualities of fundus cameras taken by ophthalmologists and non-ophthalmologists were compared to each other by taking photographs of 112 eyes from the 56 diabetic patients. In all 224 fundus images taken were graded with the three image clarity classifications.Results:Using the portable fundus camera by non-ophthalmologists, 65.2% (146/224) images were graded as excellent overall quality, 29.9% (67/224) were fair, and 4.9% (11/224) were inadequate. Using the portable fundus camera by ophthalmologists, 71.0% (159/224) images were graded as excellent overall quality, 25.4% (57/224) were fair, and 3.6% (8/224) were inadequate. Diabetic retinopathy was easily and accurately identified from fundus images obtained from the portable fundus camera, even in home visit by non-ophthalmologists.Conclusion:The mobile eye care services with a non-mydriatic portable fundus camera in integrated home-based medical care was qualified to have professional quality of fundus images. It will provide a foundational platform, which can potentially improve the accessibility of diabetic screening programs</abstract><cop>Paterna</cop><pub>Ubiquity Press</pub><doi>10.5334/ijic.ICIC20203</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1568-4156 |
ispartof | International journal of integrated care, 2021-09, Vol.21 (S1), p.183 |
issn | 1568-4156 1568-4156 |
language | eng |
recordid | cdi_proquest_journals_3100586851 |
source | Uopen Journals; DOAJ Directory of Open Access Journals; Ubiquity Partner Network Journals (Open Access); EZB-FREE-00999 freely available EZB journals; PubMed Central; PubMed Central Open Access |
subjects | Cameras Diabetes Diabetic retinopathy Medical personnel |
title | Development of a mobile eye care services in integrated home-based medical care |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-15T15%3A43%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20a%20mobile%20eye%20care%20services%20in%20integrated%20home-based%20medical%20care&rft.jtitle=International%20journal%20of%20integrated%20care&rft.au=Woung,%20Lin-Chung&rft.date=2021-09-01&rft.volume=21&rft.issue=S1&rft.spage=183&rft.pages=183-&rft.issn=1568-4156&rft.eissn=1568-4156&rft_id=info:doi/10.5334/ijic.ICIC20203&rft_dat=%3Cproquest_cross%3E3100586851%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3100586851&rft_id=info:pmid/&rfr_iscdi=true |