Homochiral zeolites as chiral modifier for voltammetry sensors with high enantioselectivity

Composite enantioselective voltammetry sensors provide a well‐known solution for the analysis and discrimination of enantiomerical drugs by voltammetry. The design of such sensor presumes the use of chiral substances to impart chirality to the electrode surface. We present the results of applying a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chirality (New York, N.Y.) N.Y.), 2024-02, Vol.36 (2)
Hauptverfasser: Vakulin, Ivan V., Zilberg, Rufina A., Galimov, Ilnar I., Sycheva, Maria A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 2
container_start_page
container_title Chirality (New York, N.Y.)
container_volume 36
creator Vakulin, Ivan V.
Zilberg, Rufina A.
Galimov, Ilnar I.
Sycheva, Maria A.
description Composite enantioselective voltammetry sensors provide a well‐known solution for the analysis and discrimination of enantiomerical drugs by voltammetry. The design of such sensor presumes the use of chiral substances to impart chirality to the electrode surface. We present the results of applying a theoretical approach based on simulating the adsorption of analyte enantiomers for preparing high enantioselectivity of pioneering enantioselective sensors using homochiral zeolites as chiral modifiers. We investigated the ability of some homochiral zeolites like CZP, ITV, OSO, STW, MFI, and SOF to act as solid chiral modifiers. Using tryptophan and tyrosine as model objects, we found that the maximum difference between the adsorption energies (ΔE ads ) of enantiomers on zeolites occurs if enantiomers are placed into the pores of zeolites. The SOF zeolite demonstrates the best enantioselectivity to both amino acids. Moreover, we compared the theoretical results with the experimental enantioselectivity value for tryptophan on a sensor designed as a paste electrode with MFI as the chiral modifier. We found that the calculated value ΔE ads (R‐S) = −11.0 kJ/mol for MFI, though it is not the best value in the zeolite set considered, it is still enough for the sensor with MFI as the chiral modifier to demonstrate a higher than usual enantioselectivity ( i p1 / i p2  = 1.58) in an experiment with R‐ and S‐ tryptophan as the analyte.
doi_str_mv 10.1002/chir.23635
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_3092982015</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3092982015</sourcerecordid><originalsourceid>FETCH-LOGICAL-c259t-98193ee210373441501ba112b2f53b58567fc4b87f0e3872802d00aa219851213</originalsourceid><addsrcrecordid>eNotUE9LwzAcDaLgnF78BAFvQucvvzRtcpShmzDwoiB4CGmX2oy2mUk2mZ_eze304PH-8B4htwwmDAAf6taFCfKCizMyYgIhK3jxcU5GIJXKAHK8JFcxrgBAFTwfkc-57_3BZTr6a33nko3URHqier90jbOBNj7Qre-S6Xubwo5GO0QfIv1xqaWt-2qpHcyQnI-2s3VyW5d21-SiMV20Nycck_fnp7fpPFu8zl6mj4usRqFSpiRT3FpkwEue50wAqwxjWGEjeCWkKMqmzitZNmC5LFECLgGMQaakYMj4mNwdc9fBf29sTHrlN2HYV2oOCpVEYGKvuj-q6uBjDLbR6-B6E3aagT6cpw-b9f95_A_WO2J0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3092982015</pqid></control><display><type>article</type><title>Homochiral zeolites as chiral modifier for voltammetry sensors with high enantioselectivity</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Vakulin, Ivan V. ; Zilberg, Rufina A. ; Galimov, Ilnar I. ; Sycheva, Maria A.</creator><creatorcontrib>Vakulin, Ivan V. ; Zilberg, Rufina A. ; Galimov, Ilnar I. ; Sycheva, Maria A.</creatorcontrib><description>Composite enantioselective voltammetry sensors provide a well‐known solution for the analysis and discrimination of enantiomerical drugs by voltammetry. The design of such sensor presumes the use of chiral substances to impart chirality to the electrode surface. We present the results of applying a theoretical approach based on simulating the adsorption of analyte enantiomers for preparing high enantioselectivity of pioneering enantioselective sensors using homochiral zeolites as chiral modifiers. We investigated the ability of some homochiral zeolites like CZP, ITV, OSO, STW, MFI, and SOF to act as solid chiral modifiers. Using tryptophan and tyrosine as model objects, we found that the maximum difference between the adsorption energies (ΔE ads ) of enantiomers on zeolites occurs if enantiomers are placed into the pores of zeolites. The SOF zeolite demonstrates the best enantioselectivity to both amino acids. Moreover, we compared the theoretical results with the experimental enantioselectivity value for tryptophan on a sensor designed as a paste electrode with MFI as the chiral modifier. We found that the calculated value ΔE ads (R‐S) = −11.0 kJ/mol for MFI, though it is not the best value in the zeolite set considered, it is still enough for the sensor with MFI as the chiral modifier to demonstrate a higher than usual enantioselectivity ( i p1 / i p2  = 1.58) in an experiment with R‐ and S‐ tryptophan as the analyte.</description><identifier>ISSN: 0899-0042</identifier><identifier>EISSN: 1520-636X</identifier><identifier>DOI: 10.1002/chir.23635</identifier><language>eng</language><publisher>Chichester: Wiley Subscription Services, Inc</publisher><subject>Adsorption ; Amino acids ; Chirality ; Drug development ; Drug discrimination ; Electrodes ; Enantiomers ; Sensors ; Tryptophan ; Tyrosine ; Voltammetry ; Zeolites</subject><ispartof>Chirality (New York, N.Y.), 2024-02, Vol.36 (2)</ispartof><rights>2023 Wiley Periodicals LLC</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c259t-98193ee210373441501ba112b2f53b58567fc4b87f0e3872802d00aa219851213</citedby><cites>FETCH-LOGICAL-c259t-98193ee210373441501ba112b2f53b58567fc4b87f0e3872802d00aa219851213</cites><orcidid>0000-0003-3466-3104</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Vakulin, Ivan V.</creatorcontrib><creatorcontrib>Zilberg, Rufina A.</creatorcontrib><creatorcontrib>Galimov, Ilnar I.</creatorcontrib><creatorcontrib>Sycheva, Maria A.</creatorcontrib><title>Homochiral zeolites as chiral modifier for voltammetry sensors with high enantioselectivity</title><title>Chirality (New York, N.Y.)</title><description>Composite enantioselective voltammetry sensors provide a well‐known solution for the analysis and discrimination of enantiomerical drugs by voltammetry. The design of such sensor presumes the use of chiral substances to impart chirality to the electrode surface. We present the results of applying a theoretical approach based on simulating the adsorption of analyte enantiomers for preparing high enantioselectivity of pioneering enantioselective sensors using homochiral zeolites as chiral modifiers. We investigated the ability of some homochiral zeolites like CZP, ITV, OSO, STW, MFI, and SOF to act as solid chiral modifiers. Using tryptophan and tyrosine as model objects, we found that the maximum difference between the adsorption energies (ΔE ads ) of enantiomers on zeolites occurs if enantiomers are placed into the pores of zeolites. The SOF zeolite demonstrates the best enantioselectivity to both amino acids. Moreover, we compared the theoretical results with the experimental enantioselectivity value for tryptophan on a sensor designed as a paste electrode with MFI as the chiral modifier. We found that the calculated value ΔE ads (R‐S) = −11.0 kJ/mol for MFI, though it is not the best value in the zeolite set considered, it is still enough for the sensor with MFI as the chiral modifier to demonstrate a higher than usual enantioselectivity ( i p1 / i p2  = 1.58) in an experiment with R‐ and S‐ tryptophan as the analyte.</description><subject>Adsorption</subject><subject>Amino acids</subject><subject>Chirality</subject><subject>Drug development</subject><subject>Drug discrimination</subject><subject>Electrodes</subject><subject>Enantiomers</subject><subject>Sensors</subject><subject>Tryptophan</subject><subject>Tyrosine</subject><subject>Voltammetry</subject><subject>Zeolites</subject><issn>0899-0042</issn><issn>1520-636X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNotUE9LwzAcDaLgnF78BAFvQucvvzRtcpShmzDwoiB4CGmX2oy2mUk2mZ_eze304PH-8B4htwwmDAAf6taFCfKCizMyYgIhK3jxcU5GIJXKAHK8JFcxrgBAFTwfkc-57_3BZTr6a33nko3URHqier90jbOBNj7Qre-S6Xubwo5GO0QfIv1xqaWt-2qpHcyQnI-2s3VyW5d21-SiMV20Nycck_fnp7fpPFu8zl6mj4usRqFSpiRT3FpkwEue50wAqwxjWGEjeCWkKMqmzitZNmC5LFECLgGMQaakYMj4mNwdc9fBf29sTHrlN2HYV2oOCpVEYGKvuj-q6uBjDLbR6-B6E3aagT6cpw-b9f95_A_WO2J0</recordid><startdate>20240201</startdate><enddate>20240201</enddate><creator>Vakulin, Ivan V.</creator><creator>Zilberg, Rufina A.</creator><creator>Galimov, Ilnar I.</creator><creator>Sycheva, Maria A.</creator><general>Wiley Subscription Services, Inc</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>7QR</scope><scope>7U7</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>P64</scope><orcidid>https://orcid.org/0000-0003-3466-3104</orcidid></search><sort><creationdate>20240201</creationdate><title>Homochiral zeolites as chiral modifier for voltammetry sensors with high enantioselectivity</title><author>Vakulin, Ivan V. ; Zilberg, Rufina A. ; Galimov, Ilnar I. ; Sycheva, Maria A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c259t-98193ee210373441501ba112b2f53b58567fc4b87f0e3872802d00aa219851213</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Adsorption</topic><topic>Amino acids</topic><topic>Chirality</topic><topic>Drug development</topic><topic>Drug discrimination</topic><topic>Electrodes</topic><topic>Enantiomers</topic><topic>Sensors</topic><topic>Tryptophan</topic><topic>Tyrosine</topic><topic>Voltammetry</topic><topic>Zeolites</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vakulin, Ivan V.</creatorcontrib><creatorcontrib>Zilberg, Rufina A.</creatorcontrib><creatorcontrib>Galimov, Ilnar I.</creatorcontrib><creatorcontrib>Sycheva, Maria A.</creatorcontrib><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Chemoreception Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Chirality (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vakulin, Ivan V.</au><au>Zilberg, Rufina A.</au><au>Galimov, Ilnar I.</au><au>Sycheva, Maria A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Homochiral zeolites as chiral modifier for voltammetry sensors with high enantioselectivity</atitle><jtitle>Chirality (New York, N.Y.)</jtitle><date>2024-02-01</date><risdate>2024</risdate><volume>36</volume><issue>2</issue><issn>0899-0042</issn><eissn>1520-636X</eissn><abstract>Composite enantioselective voltammetry sensors provide a well‐known solution for the analysis and discrimination of enantiomerical drugs by voltammetry. The design of such sensor presumes the use of chiral substances to impart chirality to the electrode surface. We present the results of applying a theoretical approach based on simulating the adsorption of analyte enantiomers for preparing high enantioselectivity of pioneering enantioselective sensors using homochiral zeolites as chiral modifiers. We investigated the ability of some homochiral zeolites like CZP, ITV, OSO, STW, MFI, and SOF to act as solid chiral modifiers. Using tryptophan and tyrosine as model objects, we found that the maximum difference between the adsorption energies (ΔE ads ) of enantiomers on zeolites occurs if enantiomers are placed into the pores of zeolites. The SOF zeolite demonstrates the best enantioselectivity to both amino acids. Moreover, we compared the theoretical results with the experimental enantioselectivity value for tryptophan on a sensor designed as a paste electrode with MFI as the chiral modifier. We found that the calculated value ΔE ads (R‐S) = −11.0 kJ/mol for MFI, though it is not the best value in the zeolite set considered, it is still enough for the sensor with MFI as the chiral modifier to demonstrate a higher than usual enantioselectivity ( i p1 / i p2  = 1.58) in an experiment with R‐ and S‐ tryptophan as the analyte.</abstract><cop>Chichester</cop><pub>Wiley Subscription Services, Inc</pub><doi>10.1002/chir.23635</doi><orcidid>https://orcid.org/0000-0003-3466-3104</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0899-0042
ispartof Chirality (New York, N.Y.), 2024-02, Vol.36 (2)
issn 0899-0042
1520-636X
language eng
recordid cdi_proquest_journals_3092982015
source Wiley Online Library Journals Frontfile Complete
subjects Adsorption
Amino acids
Chirality
Drug development
Drug discrimination
Electrodes
Enantiomers
Sensors
Tryptophan
Tyrosine
Voltammetry
Zeolites
title Homochiral zeolites as chiral modifier for voltammetry sensors with high enantioselectivity
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T04%3A02%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Homochiral%20zeolites%20as%20chiral%20modifier%20for%20voltammetry%20sensors%20with%20high%20enantioselectivity&rft.jtitle=Chirality%20(New%20York,%20N.Y.)&rft.au=Vakulin,%20Ivan%20V.&rft.date=2024-02-01&rft.volume=36&rft.issue=2&rft.issn=0899-0042&rft.eissn=1520-636X&rft_id=info:doi/10.1002/chir.23635&rft_dat=%3Cproquest_cross%3E3092982015%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3092982015&rft_id=info:pmid/&rfr_iscdi=true