Identification of Bone Density Changes Applying Impedance Spectroscopy with a Piezo-Device Coupled to a Human Tooth
Bone tissue is a calcium deposit and supporting structure of the human body, it is exposed to several pathologies that modify its mineral content. To determine these changes, different diagnostic procedures are performed with techniques using invasive ionizing radiation, which are limited by the neg...
Gespeichert in:
Veröffentlicht in: | Journal of biomimetics, biomaterials and biomedical engineering biomaterials and biomedical engineering, 2021-08, Vol.52, p.1-10 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 10 |
---|---|
container_issue | |
container_start_page | 1 |
container_title | Journal of biomimetics, biomaterials and biomedical engineering |
container_volume | 52 |
creator | Ortiz-Jimenez, Juliana Cardona, Carlos Ivan Tinoco, Hector A. Roldan-Restrepo, Samuel Jímenez-Garcia, Francy Nelly Gomez, Juan Pablo |
description | Bone tissue is a calcium deposit and supporting structure of the human body, it is exposed to several pathologies that modify its mineral content. To determine these changes, different diagnostic procedures are performed with techniques using invasive ionizing radiation, which are limited by the negative effects in the long term on human health. A methodology is explored that could be applicable in the diagnosis of pathologic variations in bone mineral density, using structural monitoring tools. The proposed technique estimates changes in bone conditions by applying impedance spectroscopy with a tooth-borne piezo-device. Bone-tooth samples were prepared to simulate a section of maxillary bone and subsequently treated with chemical agents, simulating pathologic decalcification. The piezo-device is inserted in the slot of an orthodontic bracket, previously bonded to the crown of the tooth, in order to transmit vibration to surrounding bone. The variations in bone micro-architecture were computed by image processing analyzed with samples prepared in transparent resin, allowing the measurement of morphometry before and after the induced changes in mineral content. Using vibrational bone response, impedance measurements allowed to observe the variations in bone mass as the samples were progressively decalcified. In the 5-50kHz spectrum, it was demonstrated the sensitivity of the electro-mechanical impedance during the bone alteration procedure since the electrical resistance signals of the piezo-device consistently changed in the frequency spectrum (5-50kHz). The piezo-device shows to be sensitive to the changes produced by the bone alterations, which were caused by the stiffness variations made in the sample during the decalcifying. These changes were statistically correlated to demonstrate that in a less invasive way, bone alterations could be monitored from the teeth. This result opens the door to search for a new way to diagnose bone density changes in real applications. |
doi_str_mv | 10.4028/www.scientific.net/JBBBE.52.1 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_3091669265</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3091669265</sourcerecordid><originalsourceid>FETCH-LOGICAL-c293t-ed0e21c987b0664f1a5c52344a175c65475c4c54a5221043d4b516b8508f944e3</originalsourceid><addsrcrecordid>eNqNkE9LAzEQxRdRUNTvEBCPu02ySbo5iLT1X6WgYD2HNDvbRtpk3aSW-umNVuzVy8zAvHmP-WXZJcEFw7TqbTabIhgLLtrGmsJB7D0Oh8PbgtOCHGQnlEqRy4rxw7-57B9n5yG8YYyJkJJhdpKFcf1roaP1DvkGDb0DdAMu2LhFo4V2cwho0LbLrXVzNF61UGtnAL20YGLng_HtFm1sXCCNni18-vwGPmwSjPy6XUKNok-bh_VKOzT1Pi7OsqNGLwOc__bT7PXudjp6yCdP9-PRYJIbKsuYQ42BEiOr_gwLwRqiueG0ZEyTPjeCs1SZ4UxzSglmZc1mnIhZxXHVSMagPM0udr5t59_XEKJ68-vOpUhVYkmEkFTwpLraqUz6JXTQqLazK91tFcHqG7VKqNUetUqo1Q9qxaki6f56dx877UIEs9jH_M_hC2V3j5Y</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3091669265</pqid></control><display><type>article</type><title>Identification of Bone Density Changes Applying Impedance Spectroscopy with a Piezo-Device Coupled to a Human Tooth</title><source>Scientific.net Journals</source><creator>Ortiz-Jimenez, Juliana ; Cardona, Carlos Ivan ; Tinoco, Hector A. ; Roldan-Restrepo, Samuel ; Jímenez-Garcia, Francy Nelly ; Gomez, Juan Pablo</creator><creatorcontrib>Ortiz-Jimenez, Juliana ; Cardona, Carlos Ivan ; Tinoco, Hector A. ; Roldan-Restrepo, Samuel ; Jímenez-Garcia, Francy Nelly ; Gomez, Juan Pablo</creatorcontrib><description>Bone tissue is a calcium deposit and supporting structure of the human body, it is exposed to several pathologies that modify its mineral content. To determine these changes, different diagnostic procedures are performed with techniques using invasive ionizing radiation, which are limited by the negative effects in the long term on human health. A methodology is explored that could be applicable in the diagnosis of pathologic variations in bone mineral density, using structural monitoring tools. The proposed technique estimates changes in bone conditions by applying impedance spectroscopy with a tooth-borne piezo-device. Bone-tooth samples were prepared to simulate a section of maxillary bone and subsequently treated with chemical agents, simulating pathologic decalcification. The piezo-device is inserted in the slot of an orthodontic bracket, previously bonded to the crown of the tooth, in order to transmit vibration to surrounding bone. The variations in bone micro-architecture were computed by image processing analyzed with samples prepared in transparent resin, allowing the measurement of morphometry before and after the induced changes in mineral content. Using vibrational bone response, impedance measurements allowed to observe the variations in bone mass as the samples were progressively decalcified. In the 5-50kHz spectrum, it was demonstrated the sensitivity of the electro-mechanical impedance during the bone alteration procedure since the electrical resistance signals of the piezo-device consistently changed in the frequency spectrum (5-50kHz). The piezo-device shows to be sensitive to the changes produced by the bone alterations, which were caused by the stiffness variations made in the sample during the decalcifying. These changes were statistically correlated to demonstrate that in a less invasive way, bone alterations could be monitored from the teeth. This result opens the door to search for a new way to diagnose bone density changes in real applications.</description><identifier>ISSN: 2296-9837</identifier><identifier>ISSN: 2296-9845</identifier><identifier>EISSN: 2296-9845</identifier><identifier>DOI: 10.4028/www.scientific.net/JBBBE.52.1</identifier><language>eng</language><publisher>Pfäffikon: Trans Tech Publications Ltd</publisher><subject>Bonding agents ; Bone density ; Bone mass ; Bone mineral content ; Bone mineral density ; Chemical agents ; Decalcification ; Electrical resistivity ; Frequency spectrum ; Human performance ; Image processing ; Impedance ; Impedance spectroscopy ; Ionizing radiation ; Long bone ; Mechanical impedance ; Mechanical properties ; Morphometry ; Orthodontics ; Spectroscopy ; Spectrum analysis ; Teeth ; Variation ; Vibration analysis ; Vibration measurement ; Vibration monitoring</subject><ispartof>Journal of biomimetics, biomaterials and biomedical engineering, 2021-08, Vol.52, p.1-10</ispartof><rights>2021 Trans Tech Publications Ltd</rights><rights>Copyright Trans Tech Publications Ltd. 2021</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c293t-ed0e21c987b0664f1a5c52344a175c65475c4c54a5221043d4b516b8508f944e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/6143?width=600</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids></links><search><creatorcontrib>Ortiz-Jimenez, Juliana</creatorcontrib><creatorcontrib>Cardona, Carlos Ivan</creatorcontrib><creatorcontrib>Tinoco, Hector A.</creatorcontrib><creatorcontrib>Roldan-Restrepo, Samuel</creatorcontrib><creatorcontrib>Jímenez-Garcia, Francy Nelly</creatorcontrib><creatorcontrib>Gomez, Juan Pablo</creatorcontrib><title>Identification of Bone Density Changes Applying Impedance Spectroscopy with a Piezo-Device Coupled to a Human Tooth</title><title>Journal of biomimetics, biomaterials and biomedical engineering</title><description>Bone tissue is a calcium deposit and supporting structure of the human body, it is exposed to several pathologies that modify its mineral content. To determine these changes, different diagnostic procedures are performed with techniques using invasive ionizing radiation, which are limited by the negative effects in the long term on human health. A methodology is explored that could be applicable in the diagnosis of pathologic variations in bone mineral density, using structural monitoring tools. The proposed technique estimates changes in bone conditions by applying impedance spectroscopy with a tooth-borne piezo-device. Bone-tooth samples were prepared to simulate a section of maxillary bone and subsequently treated with chemical agents, simulating pathologic decalcification. The piezo-device is inserted in the slot of an orthodontic bracket, previously bonded to the crown of the tooth, in order to transmit vibration to surrounding bone. The variations in bone micro-architecture were computed by image processing analyzed with samples prepared in transparent resin, allowing the measurement of morphometry before and after the induced changes in mineral content. Using vibrational bone response, impedance measurements allowed to observe the variations in bone mass as the samples were progressively decalcified. In the 5-50kHz spectrum, it was demonstrated the sensitivity of the electro-mechanical impedance during the bone alteration procedure since the electrical resistance signals of the piezo-device consistently changed in the frequency spectrum (5-50kHz). The piezo-device shows to be sensitive to the changes produced by the bone alterations, which were caused by the stiffness variations made in the sample during the decalcifying. These changes were statistically correlated to demonstrate that in a less invasive way, bone alterations could be monitored from the teeth. This result opens the door to search for a new way to diagnose bone density changes in real applications.</description><subject>Bonding agents</subject><subject>Bone density</subject><subject>Bone mass</subject><subject>Bone mineral content</subject><subject>Bone mineral density</subject><subject>Chemical agents</subject><subject>Decalcification</subject><subject>Electrical resistivity</subject><subject>Frequency spectrum</subject><subject>Human performance</subject><subject>Image processing</subject><subject>Impedance</subject><subject>Impedance spectroscopy</subject><subject>Ionizing radiation</subject><subject>Long bone</subject><subject>Mechanical impedance</subject><subject>Mechanical properties</subject><subject>Morphometry</subject><subject>Orthodontics</subject><subject>Spectroscopy</subject><subject>Spectrum analysis</subject><subject>Teeth</subject><subject>Variation</subject><subject>Vibration analysis</subject><subject>Vibration measurement</subject><subject>Vibration monitoring</subject><issn>2296-9837</issn><issn>2296-9845</issn><issn>2296-9845</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNqNkE9LAzEQxRdRUNTvEBCPu02ySbo5iLT1X6WgYD2HNDvbRtpk3aSW-umNVuzVy8zAvHmP-WXZJcEFw7TqbTabIhgLLtrGmsJB7D0Oh8PbgtOCHGQnlEqRy4rxw7-57B9n5yG8YYyJkJJhdpKFcf1roaP1DvkGDb0DdAMu2LhFo4V2cwho0LbLrXVzNF61UGtnAL20YGLng_HtFm1sXCCNni18-vwGPmwSjPy6XUKNok-bh_VKOzT1Pi7OsqNGLwOc__bT7PXudjp6yCdP9-PRYJIbKsuYQ42BEiOr_gwLwRqiueG0ZEyTPjeCs1SZ4UxzSglmZc1mnIhZxXHVSMagPM0udr5t59_XEKJ68-vOpUhVYkmEkFTwpLraqUz6JXTQqLazK91tFcHqG7VKqNUetUqo1Q9qxaki6f56dx877UIEs9jH_M_hC2V3j5Y</recordid><startdate>20210810</startdate><enddate>20210810</enddate><creator>Ortiz-Jimenez, Juliana</creator><creator>Cardona, Carlos Ivan</creator><creator>Tinoco, Hector A.</creator><creator>Roldan-Restrepo, Samuel</creator><creator>Jímenez-Garcia, Francy Nelly</creator><creator>Gomez, Juan Pablo</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QP</scope><scope>7QQ</scope><scope>7SE</scope><scope>7SR</scope><scope>7T5</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>H94</scope><scope>JG9</scope><scope>P64</scope></search><sort><creationdate>20210810</creationdate><title>Identification of Bone Density Changes Applying Impedance Spectroscopy with a Piezo-Device Coupled to a Human Tooth</title><author>Ortiz-Jimenez, Juliana ; Cardona, Carlos Ivan ; Tinoco, Hector A. ; Roldan-Restrepo, Samuel ; Jímenez-Garcia, Francy Nelly ; Gomez, Juan Pablo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c293t-ed0e21c987b0664f1a5c52344a175c65475c4c54a5221043d4b516b8508f944e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Bonding agents</topic><topic>Bone density</topic><topic>Bone mass</topic><topic>Bone mineral content</topic><topic>Bone mineral density</topic><topic>Chemical agents</topic><topic>Decalcification</topic><topic>Electrical resistivity</topic><topic>Frequency spectrum</topic><topic>Human performance</topic><topic>Image processing</topic><topic>Impedance</topic><topic>Impedance spectroscopy</topic><topic>Ionizing radiation</topic><topic>Long bone</topic><topic>Mechanical impedance</topic><topic>Mechanical properties</topic><topic>Morphometry</topic><topic>Orthodontics</topic><topic>Spectroscopy</topic><topic>Spectrum analysis</topic><topic>Teeth</topic><topic>Variation</topic><topic>Vibration analysis</topic><topic>Vibration measurement</topic><topic>Vibration monitoring</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ortiz-Jimenez, Juliana</creatorcontrib><creatorcontrib>Cardona, Carlos Ivan</creatorcontrib><creatorcontrib>Tinoco, Hector A.</creatorcontrib><creatorcontrib>Roldan-Restrepo, Samuel</creatorcontrib><creatorcontrib>Jímenez-Garcia, Francy Nelly</creatorcontrib><creatorcontrib>Gomez, Juan Pablo</creatorcontrib><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Calcium & Calcified Tissue Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Immunology Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Journal of biomimetics, biomaterials and biomedical engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ortiz-Jimenez, Juliana</au><au>Cardona, Carlos Ivan</au><au>Tinoco, Hector A.</au><au>Roldan-Restrepo, Samuel</au><au>Jímenez-Garcia, Francy Nelly</au><au>Gomez, Juan Pablo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Identification of Bone Density Changes Applying Impedance Spectroscopy with a Piezo-Device Coupled to a Human Tooth</atitle><jtitle>Journal of biomimetics, biomaterials and biomedical engineering</jtitle><date>2021-08-10</date><risdate>2021</risdate><volume>52</volume><spage>1</spage><epage>10</epage><pages>1-10</pages><issn>2296-9837</issn><issn>2296-9845</issn><eissn>2296-9845</eissn><abstract>Bone tissue is a calcium deposit and supporting structure of the human body, it is exposed to several pathologies that modify its mineral content. To determine these changes, different diagnostic procedures are performed with techniques using invasive ionizing radiation, which are limited by the negative effects in the long term on human health. A methodology is explored that could be applicable in the diagnosis of pathologic variations in bone mineral density, using structural monitoring tools. The proposed technique estimates changes in bone conditions by applying impedance spectroscopy with a tooth-borne piezo-device. Bone-tooth samples were prepared to simulate a section of maxillary bone and subsequently treated with chemical agents, simulating pathologic decalcification. The piezo-device is inserted in the slot of an orthodontic bracket, previously bonded to the crown of the tooth, in order to transmit vibration to surrounding bone. The variations in bone micro-architecture were computed by image processing analyzed with samples prepared in transparent resin, allowing the measurement of morphometry before and after the induced changes in mineral content. Using vibrational bone response, impedance measurements allowed to observe the variations in bone mass as the samples were progressively decalcified. In the 5-50kHz spectrum, it was demonstrated the sensitivity of the electro-mechanical impedance during the bone alteration procedure since the electrical resistance signals of the piezo-device consistently changed in the frequency spectrum (5-50kHz). The piezo-device shows to be sensitive to the changes produced by the bone alterations, which were caused by the stiffness variations made in the sample during the decalcifying. These changes were statistically correlated to demonstrate that in a less invasive way, bone alterations could be monitored from the teeth. This result opens the door to search for a new way to diagnose bone density changes in real applications.</abstract><cop>Pfäffikon</cop><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/JBBBE.52.1</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2296-9837 |
ispartof | Journal of biomimetics, biomaterials and biomedical engineering, 2021-08, Vol.52, p.1-10 |
issn | 2296-9837 2296-9845 2296-9845 |
language | eng |
recordid | cdi_proquest_journals_3091669265 |
source | Scientific.net Journals |
subjects | Bonding agents Bone density Bone mass Bone mineral content Bone mineral density Chemical agents Decalcification Electrical resistivity Frequency spectrum Human performance Image processing Impedance Impedance spectroscopy Ionizing radiation Long bone Mechanical impedance Mechanical properties Morphometry Orthodontics Spectroscopy Spectrum analysis Teeth Variation Vibration analysis Vibration measurement Vibration monitoring |
title | Identification of Bone Density Changes Applying Impedance Spectroscopy with a Piezo-Device Coupled to a Human Tooth |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T14%3A08%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Identification%20of%20Bone%20Density%20Changes%20Applying%20Impedance%20Spectroscopy%20with%20a%20Piezo-Device%20Coupled%20to%20a%20Human%20Tooth&rft.jtitle=Journal%20of%20biomimetics,%20biomaterials%20and%20biomedical%20engineering&rft.au=Ortiz-Jimenez,%20Juliana&rft.date=2021-08-10&rft.volume=52&rft.spage=1&rft.epage=10&rft.pages=1-10&rft.issn=2296-9837&rft.eissn=2296-9845&rft_id=info:doi/10.4028/www.scientific.net/JBBBE.52.1&rft_dat=%3Cproquest_cross%3E3091669265%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3091669265&rft_id=info:pmid/&rfr_iscdi=true |