An interactive framework for the evaluation and detection of stereoacuity threshold under ambient lighting

Objective: Our study aims to provide a novel framework for the continuous evaluation of stereoacuity under ambient lighting conditions using Bayesian inference. Methods: We applied a combination of psychophysical and expected entropy minimization procedures for the computation of a continuous stereo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:arXiv.org 2024-06
Hauptverfasser: Lohia, Kritika, Rijul, Saurabh Soans, Saxena, Rohit, Gandhi, Tapan Kumar
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Lohia, Kritika
Rijul, Saurabh Soans
Saxena, Rohit
Gandhi, Tapan Kumar
description Objective: Our study aims to provide a novel framework for the continuous evaluation of stereoacuity under ambient lighting conditions using Bayesian inference. Methods: We applied a combination of psychophysical and expected entropy minimization procedures for the computation of a continuous stereoacuity threshold. Subsequently, we evaluated the effect of ambient lighting during stereoacuity testing (ST) by adopting a bisection-matching based adaptive gamma calibration (AGC). Participants (\(N=187\)) including visually healthy controls (\(N=51\)), patients with Intermittent Divergent Squint (IDS; \(N=45\)), and controls with induced anisometropia (IA; \(N=91\)) performed ST with and without AGC under two lighting conditions: completely dark (20 cd/m\(^2\)) and normally lit (130 cd/m\(^2\)) rooms. Results: Our framework demonstrated "excellent" reliability (\(> 0.9\)) and a positive correlation with TNO (a clinical stereo test), regardless of whether AGC was conducted. However, when AGC is not performed, significant differences (Friedman \(X_{r}^{2} = 28.015\); \(p
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_3072928201</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3072928201</sourcerecordid><originalsourceid>FETCH-proquest_journals_30729282013</originalsourceid><addsrcrecordid>eNqNi9EKgjAUhkcQJOU7HOhamFumXUYUPUD3sfSoM91qOzN6-yR6gK5-Pr7vn7FISJkmxUaIBYu97zjnYpuLLJMR6_YGtCF0qiQ9ItRODfiy7g61dUAtAo6qD4q0NaBMBRUSll-yNfjpiFaVQdN7ih361vYVBFOhAzXcNBqCXjctadOs2LxWvcf4t0u2Ph0vh3PycPYZ0NO1s8GZSV0lz8VOFIKn8r_qA5EmSbc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3072928201</pqid></control><display><type>article</type><title>An interactive framework for the evaluation and detection of stereoacuity threshold under ambient lighting</title><source>Free E- Journals</source><creator>Lohia, Kritika ; Rijul, Saurabh Soans ; Saxena, Rohit ; Gandhi, Tapan Kumar</creator><creatorcontrib>Lohia, Kritika ; Rijul, Saurabh Soans ; Saxena, Rohit ; Gandhi, Tapan Kumar</creatorcontrib><description>Objective: Our study aims to provide a novel framework for the continuous evaluation of stereoacuity under ambient lighting conditions using Bayesian inference. Methods: We applied a combination of psychophysical and expected entropy minimization procedures for the computation of a continuous stereoacuity threshold. Subsequently, we evaluated the effect of ambient lighting during stereoacuity testing (ST) by adopting a bisection-matching based adaptive gamma calibration (AGC). Participants (\(N=187\)) including visually healthy controls (\(N=51\)), patients with Intermittent Divergent Squint (IDS; \(N=45\)), and controls with induced anisometropia (IA; \(N=91\)) performed ST with and without AGC under two lighting conditions: completely dark (20 cd/m\(^2\)) and normally lit (130 cd/m\(^2\)) rooms. Results: Our framework demonstrated "excellent" reliability (\(&gt; 0.9\)) and a positive correlation with TNO (a clinical stereo test), regardless of whether AGC was conducted. However, when AGC is not performed, significant differences (Friedman \(X_{r}^{2} = 28.015\); \(p&lt;0.00001\); Bland-Altman bias: 30 arc-sec) were found in stereoacuity thresholds between dark and light conditions for participants with IDS and IA. Controls are unaffected by AGC and yield a similar stereoacuity threshold under both lighting conditions. Conclusion: Our study proves that stereoacuity threshold is significantly deviated particularly in participants with IDS or IA stereo-deficits if ambient lighting is not taken into consideration. Moreover, our framework provides a quick (approximately 5-10 minutes) assessment of stereoacuity threshold and can be performed within 30 ST and 15 AGC trials. Significance: Our test is useful in planning treatments and monitoring prognosis for patients with stereo-deficits by accurately assessing stereovision.</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Bayesian analysis ; Lighting ; Statistical inference ; Trans-Neptunian objects</subject><ispartof>arXiv.org, 2024-06</ispartof><rights>2024. This work is published under http://creativecommons.org/licenses/by-nc-nd/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>780,784</link.rule.ids></links><search><creatorcontrib>Lohia, Kritika</creatorcontrib><creatorcontrib>Rijul, Saurabh Soans</creatorcontrib><creatorcontrib>Saxena, Rohit</creatorcontrib><creatorcontrib>Gandhi, Tapan Kumar</creatorcontrib><title>An interactive framework for the evaluation and detection of stereoacuity threshold under ambient lighting</title><title>arXiv.org</title><description>Objective: Our study aims to provide a novel framework for the continuous evaluation of stereoacuity under ambient lighting conditions using Bayesian inference. Methods: We applied a combination of psychophysical and expected entropy minimization procedures for the computation of a continuous stereoacuity threshold. Subsequently, we evaluated the effect of ambient lighting during stereoacuity testing (ST) by adopting a bisection-matching based adaptive gamma calibration (AGC). Participants (\(N=187\)) including visually healthy controls (\(N=51\)), patients with Intermittent Divergent Squint (IDS; \(N=45\)), and controls with induced anisometropia (IA; \(N=91\)) performed ST with and without AGC under two lighting conditions: completely dark (20 cd/m\(^2\)) and normally lit (130 cd/m\(^2\)) rooms. Results: Our framework demonstrated "excellent" reliability (\(&gt; 0.9\)) and a positive correlation with TNO (a clinical stereo test), regardless of whether AGC was conducted. However, when AGC is not performed, significant differences (Friedman \(X_{r}^{2} = 28.015\); \(p&lt;0.00001\); Bland-Altman bias: 30 arc-sec) were found in stereoacuity thresholds between dark and light conditions for participants with IDS and IA. Controls are unaffected by AGC and yield a similar stereoacuity threshold under both lighting conditions. Conclusion: Our study proves that stereoacuity threshold is significantly deviated particularly in participants with IDS or IA stereo-deficits if ambient lighting is not taken into consideration. Moreover, our framework provides a quick (approximately 5-10 minutes) assessment of stereoacuity threshold and can be performed within 30 ST and 15 AGC trials. Significance: Our test is useful in planning treatments and monitoring prognosis for patients with stereo-deficits by accurately assessing stereovision.</description><subject>Bayesian analysis</subject><subject>Lighting</subject><subject>Statistical inference</subject><subject>Trans-Neptunian objects</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqNi9EKgjAUhkcQJOU7HOhamFumXUYUPUD3sfSoM91qOzN6-yR6gK5-Pr7vn7FISJkmxUaIBYu97zjnYpuLLJMR6_YGtCF0qiQ9ItRODfiy7g61dUAtAo6qD4q0NaBMBRUSll-yNfjpiFaVQdN7ih361vYVBFOhAzXcNBqCXjctadOs2LxWvcf4t0u2Ph0vh3PycPYZ0NO1s8GZSV0lz8VOFIKn8r_qA5EmSbc</recordid><startdate>20240626</startdate><enddate>20240626</enddate><creator>Lohia, Kritika</creator><creator>Rijul, Saurabh Soans</creator><creator>Saxena, Rohit</creator><creator>Gandhi, Tapan Kumar</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20240626</creationdate><title>An interactive framework for the evaluation and detection of stereoacuity threshold under ambient lighting</title><author>Lohia, Kritika ; Rijul, Saurabh Soans ; Saxena, Rohit ; Gandhi, Tapan Kumar</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_30729282013</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Bayesian analysis</topic><topic>Lighting</topic><topic>Statistical inference</topic><topic>Trans-Neptunian objects</topic><toplevel>online_resources</toplevel><creatorcontrib>Lohia, Kritika</creatorcontrib><creatorcontrib>Rijul, Saurabh Soans</creatorcontrib><creatorcontrib>Saxena, Rohit</creatorcontrib><creatorcontrib>Gandhi, Tapan Kumar</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lohia, Kritika</au><au>Rijul, Saurabh Soans</au><au>Saxena, Rohit</au><au>Gandhi, Tapan Kumar</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>An interactive framework for the evaluation and detection of stereoacuity threshold under ambient lighting</atitle><jtitle>arXiv.org</jtitle><date>2024-06-26</date><risdate>2024</risdate><eissn>2331-8422</eissn><abstract>Objective: Our study aims to provide a novel framework for the continuous evaluation of stereoacuity under ambient lighting conditions using Bayesian inference. Methods: We applied a combination of psychophysical and expected entropy minimization procedures for the computation of a continuous stereoacuity threshold. Subsequently, we evaluated the effect of ambient lighting during stereoacuity testing (ST) by adopting a bisection-matching based adaptive gamma calibration (AGC). Participants (\(N=187\)) including visually healthy controls (\(N=51\)), patients with Intermittent Divergent Squint (IDS; \(N=45\)), and controls with induced anisometropia (IA; \(N=91\)) performed ST with and without AGC under two lighting conditions: completely dark (20 cd/m\(^2\)) and normally lit (130 cd/m\(^2\)) rooms. Results: Our framework demonstrated "excellent" reliability (\(&gt; 0.9\)) and a positive correlation with TNO (a clinical stereo test), regardless of whether AGC was conducted. However, when AGC is not performed, significant differences (Friedman \(X_{r}^{2} = 28.015\); \(p&lt;0.00001\); Bland-Altman bias: 30 arc-sec) were found in stereoacuity thresholds between dark and light conditions for participants with IDS and IA. Controls are unaffected by AGC and yield a similar stereoacuity threshold under both lighting conditions. Conclusion: Our study proves that stereoacuity threshold is significantly deviated particularly in participants with IDS or IA stereo-deficits if ambient lighting is not taken into consideration. Moreover, our framework provides a quick (approximately 5-10 minutes) assessment of stereoacuity threshold and can be performed within 30 ST and 15 AGC trials. Significance: Our test is useful in planning treatments and monitoring prognosis for patients with stereo-deficits by accurately assessing stereovision.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2024-06
issn 2331-8422
language eng
recordid cdi_proquest_journals_3072928201
source Free E- Journals
subjects Bayesian analysis
Lighting
Statistical inference
Trans-Neptunian objects
title An interactive framework for the evaluation and detection of stereoacuity threshold under ambient lighting
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T18%3A18%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=An%20interactive%20framework%20for%20the%20evaluation%20and%20detection%20of%20stereoacuity%20threshold%20under%20ambient%20lighting&rft.jtitle=arXiv.org&rft.au=Lohia,%20Kritika&rft.date=2024-06-26&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E3072928201%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3072928201&rft_id=info:pmid/&rfr_iscdi=true