Selecting Feasible Trajectories for Robot-Based X-ray Tomography by Varying Focus-Detector-Distance in Space Restricted Environments

Computed tomography has evolved as an essential tool for non-destructive testing within the automotive industry. The application of robot-based computed tomography enables high-resolution CT inspections of components exceeding the dimensions accommodated by conventional systems. However, large-scale...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of nondestructive evaluation 2024-06, Vol.43 (2), Article 65
Hauptverfasser: Linde, Maximilian, Wiest, Wolfram, Trauth, Anna, Sause, Markus G. R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 2
container_start_page
container_title Journal of nondestructive evaluation
container_volume 43
creator Linde, Maximilian
Wiest, Wolfram
Trauth, Anna
Sause, Markus G. R.
description Computed tomography has evolved as an essential tool for non-destructive testing within the automotive industry. The application of robot-based computed tomography enables high-resolution CT inspections of components exceeding the dimensions accommodated by conventional systems. However, large-scale components, e.g. vehicle bodies, often exhibit trajectory-limiting elements. The utilization of conventional trajectories with constant Focus-Detector-Distances can lead to anisotropy in image data due to the inaccessibility of some angular directions. In this work, we introduce two approaches that are able to select suitable acquisitions point sets in scans of challenging to access regions through the integration of projections with varying Focus-Detector-Distances. The variable distances of the X-ray hardware enable the capability to navigate around collision structures, thus facilitating the scanning of absent angular directions. The initial approach incorporates collision-free viewpoints along a spherical trajectory, preserving the field of view by maintaining a constant ratio between the Focus-Object-Distance and the Object-Detector-Distance, while discreetly extending the Focus-Detector-Distance. The second methodology represents a more straightforward approach, enabling the scanning of angular sectors that were previously inaccessible on the conventional circular trajectory by circumventing the X-ray source around these collision elements. Both the qualitative and quantitative evaluations, contrasting classical trajectories characterized by constant Focus-Detector-Distances with the proposed techniques employing variable Focus-Detector-Distances, indicate that the developed methods improve the object structure interpretability for scans of limited accessibility.
doi_str_mv 10.1007/s10921-024-01075-8
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_3056206124</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3056206124</sourcerecordid><originalsourceid>FETCH-LOGICAL-c314t-683ebde7c404fac93b8753943e179ae7df61a8c611c512a3194434574dfd09d3</originalsourceid><addsrcrecordid>eNp9kEFLAzEQhYMoWKt_wFPAczSzyW42R22tCoLQFvEWstnZuqXd1GQr9O4PN7aCN08zDO99M_MIuQR-DZyrmwhcZ8B4JhkHrnJWHpEB5EowWRbZMRlw0DnTmS5PyVmMS865LhUMyNcMV-j6tlvQCdrYViuk82CXaeZDi5E2PtCpr3zP7mzEmr6xYHd07td-EezmfUerHX21YbcneLeNbIz93s3Gbext55C2HZ1tbGqmGPvQuj5x7rvPNvhujV0fz8lJY1cRL37rkMwn9_PRI3t-eXga3T4zJ0D2rCgFVjUqJ7lsrNOiKlUutBQISltUdVOALV0B4HLIrAAtpZC5knVTc12LIbk6YDfBf2zTKWbpt6FLG43geZHxAjKZVNlB5YKPMWBjNqFdpw8NcPMTtjmEbVLYZh-2KZNJHEwxibsFhj_0P65vniyDiQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3056206124</pqid></control><display><type>article</type><title>Selecting Feasible Trajectories for Robot-Based X-ray Tomography by Varying Focus-Detector-Distance in Space Restricted Environments</title><source>SpringerNature Journals</source><creator>Linde, Maximilian ; Wiest, Wolfram ; Trauth, Anna ; Sause, Markus G. R.</creator><creatorcontrib>Linde, Maximilian ; Wiest, Wolfram ; Trauth, Anna ; Sause, Markus G. R.</creatorcontrib><description>Computed tomography has evolved as an essential tool for non-destructive testing within the automotive industry. The application of robot-based computed tomography enables high-resolution CT inspections of components exceeding the dimensions accommodated by conventional systems. However, large-scale components, e.g. vehicle bodies, often exhibit trajectory-limiting elements. The utilization of conventional trajectories with constant Focus-Detector-Distances can lead to anisotropy in image data due to the inaccessibility of some angular directions. In this work, we introduce two approaches that are able to select suitable acquisitions point sets in scans of challenging to access regions through the integration of projections with varying Focus-Detector-Distances. The variable distances of the X-ray hardware enable the capability to navigate around collision structures, thus facilitating the scanning of absent angular directions. The initial approach incorporates collision-free viewpoints along a spherical trajectory, preserving the field of view by maintaining a constant ratio between the Focus-Object-Distance and the Object-Detector-Distance, while discreetly extending the Focus-Detector-Distance. The second methodology represents a more straightforward approach, enabling the scanning of angular sectors that were previously inaccessible on the conventional circular trajectory by circumventing the X-ray source around these collision elements. Both the qualitative and quantitative evaluations, contrasting classical trajectories characterized by constant Focus-Detector-Distances with the proposed techniques employing variable Focus-Detector-Distances, indicate that the developed methods improve the object structure interpretability for scans of limited accessibility.</description><identifier>ISSN: 0195-9298</identifier><identifier>EISSN: 1573-4862</identifier><identifier>DOI: 10.1007/s10921-024-01075-8</identifier><language>eng</language><publisher>New York: Springer US</publisher><subject>Anisotropy ; Automobile industry ; Characterization and Evaluation of Materials ; Classical Mechanics ; Collision avoidance ; Computed tomography ; Control ; Dynamical Systems ; Engineering ; Nondestructive testing ; Robots ; Sensors ; Solid Mechanics ; Tomography ; Trajectory analysis ; Vibration ; X ray sources</subject><ispartof>Journal of nondestructive evaluation, 2024-06, Vol.43 (2), Article 65</ispartof><rights>The Author(s) 2024</rights><rights>The Author(s) 2024. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c314t-683ebde7c404fac93b8753943e179ae7df61a8c611c512a3194434574dfd09d3</cites><orcidid>0000-0002-3164-4357 ; 0000-0002-6477-0691</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s10921-024-01075-8$$EPDF$$P50$$Gspringer$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s10921-024-01075-8$$EHTML$$P50$$Gspringer$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids></links><search><creatorcontrib>Linde, Maximilian</creatorcontrib><creatorcontrib>Wiest, Wolfram</creatorcontrib><creatorcontrib>Trauth, Anna</creatorcontrib><creatorcontrib>Sause, Markus G. R.</creatorcontrib><title>Selecting Feasible Trajectories for Robot-Based X-ray Tomography by Varying Focus-Detector-Distance in Space Restricted Environments</title><title>Journal of nondestructive evaluation</title><addtitle>J Nondestruct Eval</addtitle><description>Computed tomography has evolved as an essential tool for non-destructive testing within the automotive industry. The application of robot-based computed tomography enables high-resolution CT inspections of components exceeding the dimensions accommodated by conventional systems. However, large-scale components, e.g. vehicle bodies, often exhibit trajectory-limiting elements. The utilization of conventional trajectories with constant Focus-Detector-Distances can lead to anisotropy in image data due to the inaccessibility of some angular directions. In this work, we introduce two approaches that are able to select suitable acquisitions point sets in scans of challenging to access regions through the integration of projections with varying Focus-Detector-Distances. The variable distances of the X-ray hardware enable the capability to navigate around collision structures, thus facilitating the scanning of absent angular directions. The initial approach incorporates collision-free viewpoints along a spherical trajectory, preserving the field of view by maintaining a constant ratio between the Focus-Object-Distance and the Object-Detector-Distance, while discreetly extending the Focus-Detector-Distance. The second methodology represents a more straightforward approach, enabling the scanning of angular sectors that were previously inaccessible on the conventional circular trajectory by circumventing the X-ray source around these collision elements. Both the qualitative and quantitative evaluations, contrasting classical trajectories characterized by constant Focus-Detector-Distances with the proposed techniques employing variable Focus-Detector-Distances, indicate that the developed methods improve the object structure interpretability for scans of limited accessibility.</description><subject>Anisotropy</subject><subject>Automobile industry</subject><subject>Characterization and Evaluation of Materials</subject><subject>Classical Mechanics</subject><subject>Collision avoidance</subject><subject>Computed tomography</subject><subject>Control</subject><subject>Dynamical Systems</subject><subject>Engineering</subject><subject>Nondestructive testing</subject><subject>Robots</subject><subject>Sensors</subject><subject>Solid Mechanics</subject><subject>Tomography</subject><subject>Trajectory analysis</subject><subject>Vibration</subject><subject>X ray sources</subject><issn>0195-9298</issn><issn>1573-4862</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>C6C</sourceid><recordid>eNp9kEFLAzEQhYMoWKt_wFPAczSzyW42R22tCoLQFvEWstnZuqXd1GQr9O4PN7aCN08zDO99M_MIuQR-DZyrmwhcZ8B4JhkHrnJWHpEB5EowWRbZMRlw0DnTmS5PyVmMS865LhUMyNcMV-j6tlvQCdrYViuk82CXaeZDi5E2PtCpr3zP7mzEmr6xYHd07td-EezmfUerHX21YbcneLeNbIz93s3Gbext55C2HZ1tbGqmGPvQuj5x7rvPNvhujV0fz8lJY1cRL37rkMwn9_PRI3t-eXga3T4zJ0D2rCgFVjUqJ7lsrNOiKlUutBQISltUdVOALV0B4HLIrAAtpZC5knVTc12LIbk6YDfBf2zTKWbpt6FLG43geZHxAjKZVNlB5YKPMWBjNqFdpw8NcPMTtjmEbVLYZh-2KZNJHEwxibsFhj_0P65vniyDiQ</recordid><startdate>20240601</startdate><enddate>20240601</enddate><creator>Linde, Maximilian</creator><creator>Wiest, Wolfram</creator><creator>Trauth, Anna</creator><creator>Sause, Markus G. R.</creator><general>Springer US</general><general>Springer Nature B.V</general><scope>C6C</scope><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-3164-4357</orcidid><orcidid>https://orcid.org/0000-0002-6477-0691</orcidid></search><sort><creationdate>20240601</creationdate><title>Selecting Feasible Trajectories for Robot-Based X-ray Tomography by Varying Focus-Detector-Distance in Space Restricted Environments</title><author>Linde, Maximilian ; Wiest, Wolfram ; Trauth, Anna ; Sause, Markus G. R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c314t-683ebde7c404fac93b8753943e179ae7df61a8c611c512a3194434574dfd09d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Anisotropy</topic><topic>Automobile industry</topic><topic>Characterization and Evaluation of Materials</topic><topic>Classical Mechanics</topic><topic>Collision avoidance</topic><topic>Computed tomography</topic><topic>Control</topic><topic>Dynamical Systems</topic><topic>Engineering</topic><topic>Nondestructive testing</topic><topic>Robots</topic><topic>Sensors</topic><topic>Solid Mechanics</topic><topic>Tomography</topic><topic>Trajectory analysis</topic><topic>Vibration</topic><topic>X ray sources</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Linde, Maximilian</creatorcontrib><creatorcontrib>Wiest, Wolfram</creatorcontrib><creatorcontrib>Trauth, Anna</creatorcontrib><creatorcontrib>Sause, Markus G. R.</creatorcontrib><collection>Springer Nature OA/Free Journals</collection><collection>CrossRef</collection><jtitle>Journal of nondestructive evaluation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Linde, Maximilian</au><au>Wiest, Wolfram</au><au>Trauth, Anna</au><au>Sause, Markus G. R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Selecting Feasible Trajectories for Robot-Based X-ray Tomography by Varying Focus-Detector-Distance in Space Restricted Environments</atitle><jtitle>Journal of nondestructive evaluation</jtitle><stitle>J Nondestruct Eval</stitle><date>2024-06-01</date><risdate>2024</risdate><volume>43</volume><issue>2</issue><artnum>65</artnum><issn>0195-9298</issn><eissn>1573-4862</eissn><abstract>Computed tomography has evolved as an essential tool for non-destructive testing within the automotive industry. The application of robot-based computed tomography enables high-resolution CT inspections of components exceeding the dimensions accommodated by conventional systems. However, large-scale components, e.g. vehicle bodies, often exhibit trajectory-limiting elements. The utilization of conventional trajectories with constant Focus-Detector-Distances can lead to anisotropy in image data due to the inaccessibility of some angular directions. In this work, we introduce two approaches that are able to select suitable acquisitions point sets in scans of challenging to access regions through the integration of projections with varying Focus-Detector-Distances. The variable distances of the X-ray hardware enable the capability to navigate around collision structures, thus facilitating the scanning of absent angular directions. The initial approach incorporates collision-free viewpoints along a spherical trajectory, preserving the field of view by maintaining a constant ratio between the Focus-Object-Distance and the Object-Detector-Distance, while discreetly extending the Focus-Detector-Distance. The second methodology represents a more straightforward approach, enabling the scanning of angular sectors that were previously inaccessible on the conventional circular trajectory by circumventing the X-ray source around these collision elements. Both the qualitative and quantitative evaluations, contrasting classical trajectories characterized by constant Focus-Detector-Distances with the proposed techniques employing variable Focus-Detector-Distances, indicate that the developed methods improve the object structure interpretability for scans of limited accessibility.</abstract><cop>New York</cop><pub>Springer US</pub><doi>10.1007/s10921-024-01075-8</doi><orcidid>https://orcid.org/0000-0002-3164-4357</orcidid><orcidid>https://orcid.org/0000-0002-6477-0691</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0195-9298
ispartof Journal of nondestructive evaluation, 2024-06, Vol.43 (2), Article 65
issn 0195-9298
1573-4862
language eng
recordid cdi_proquest_journals_3056206124
source SpringerNature Journals
subjects Anisotropy
Automobile industry
Characterization and Evaluation of Materials
Classical Mechanics
Collision avoidance
Computed tomography
Control
Dynamical Systems
Engineering
Nondestructive testing
Robots
Sensors
Solid Mechanics
Tomography
Trajectory analysis
Vibration
X ray sources
title Selecting Feasible Trajectories for Robot-Based X-ray Tomography by Varying Focus-Detector-Distance in Space Restricted Environments
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T14%3A27%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Selecting%20Feasible%20Trajectories%20for%20Robot-Based%20X-ray%20Tomography%20by%20Varying%20Focus-Detector-Distance%20in%20Space%20Restricted%20Environments&rft.jtitle=Journal%20of%20nondestructive%20evaluation&rft.au=Linde,%20Maximilian&rft.date=2024-06-01&rft.volume=43&rft.issue=2&rft.artnum=65&rft.issn=0195-9298&rft.eissn=1573-4862&rft_id=info:doi/10.1007/s10921-024-01075-8&rft_dat=%3Cproquest_cross%3E3056206124%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3056206124&rft_id=info:pmid/&rfr_iscdi=true