Stent graft implantation from distal radial access—A novel way to treat femoral access site complication during transcatheter aortic valve replacement: A case report
In this paper, a case of an 82‐year‐old man who was admitted to our department with sever symptomatic degenerative aortic valve stenosis is presented and discussed. After all screening procedures, a successful transfemoral transcatheter aortic valve replacement was performed, but the closure of the...
Gespeichert in:
Veröffentlicht in: | Catheterization and cardiovascular interventions 2024-04, Vol.103 (5), p.803-807 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 807 |
---|---|
container_issue | 5 |
container_start_page | 803 |
container_title | Catheterization and cardiovascular interventions |
container_volume | 103 |
creator | Andréka, Judit Sasi, Viktor Tóth, Gábor G. Ruzsa, Zoltán |
description | In this paper, a case of an 82‐year‐old man who was admitted to our department with sever symptomatic degenerative aortic valve stenosis is presented and discussed. After all screening procedures, a successful transfemoral transcatheter aortic valve replacement was performed, but the closure of the femoral access was unsuccessful due to suture‐based device failure. We decided to perform a prolonged balloon dilatation and external compression at the bleeding site, but the bleeding did not stop; therefore, an iCover stent graft was implanted from distal radial artery access using slender technique. Following that, the bleeding was stopped, and the patient had an uneventful outcome. |
doi_str_mv | 10.1002/ccd.31001 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_3037568620</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3037568620</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3551-bdcf35654a76db9929421adce1a6b41794352694d00217ad2c161a41244c0e843</originalsourceid><addsrcrecordid>eNp1kcFO3DAQhq2qqFDaAy-ARuqphwXbcZykt9XSlkpIHNpKvUWz9gSMknixvYv2xkPwDn0vngRDttx6mtHo0zej-Rk7EvxEcC5PjbEnRe7EG3YgSilnldR_3u560Si9z97HeMM5b7Rs3rH9olairEV9wP7-TDQmuArYJXDDqscxYXJ-hC74AayLCXsIaF0uaAzF-Hj_MIfRb6iHO9xC8pACYYKOBh9eKYguERiflc5MRrsObrzKNI4xj64pUQD0ITkDG-w3BIHyAYaGfNIXmIPB-DLLyAe212Ef6eOuHrLf377-WpzPLi6__1jML2amKEsxW1rTFaUuFVbaLptGNkoKtIYE6qUSVaOKUupG2fw2UaGVRmiBSkilDKdaFYfs0-RdBX-7ppjaG78OY17ZFryoSl1ryTP1eaJM8DEG6tpVcAOGbSt4-xxJmyNpXyLJ7PHOuF4OZF_Jfxlk4HQC7lxP2_-b2sXibFI-AZi1mJ4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3037568620</pqid></control><display><type>article</type><title>Stent graft implantation from distal radial access—A novel way to treat femoral access site complication during transcatheter aortic valve replacement: A case report</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Andréka, Judit ; Sasi, Viktor ; Tóth, Gábor G. ; Ruzsa, Zoltán</creator><creatorcontrib>Andréka, Judit ; Sasi, Viktor ; Tóth, Gábor G. ; Ruzsa, Zoltán</creatorcontrib><description>In this paper, a case of an 82‐year‐old man who was admitted to our department with sever symptomatic degenerative aortic valve stenosis is presented and discussed. After all screening procedures, a successful transfemoral transcatheter aortic valve replacement was performed, but the closure of the femoral access was unsuccessful due to suture‐based device failure. We decided to perform a prolonged balloon dilatation and external compression at the bleeding site, but the bleeding did not stop; therefore, an iCover stent graft was implanted from distal radial artery access using slender technique. Following that, the bleeding was stopped, and the patient had an uneventful outcome.</description><identifier>ISSN: 1522-1946</identifier><identifier>EISSN: 1522-726X</identifier><identifier>DOI: 10.1002/ccd.31001</identifier><identifier>PMID: 38415818</identifier><language>eng</language><publisher>United States: Wiley Subscription Services, Inc</publisher><subject>Aortic valve ; Balloon treatment ; Bleeding ; distal radial artery access ; femoral access complications ; Femur ; Implants ; Stenosis ; transcatheter aortic valve replacement</subject><ispartof>Catheterization and cardiovascular interventions, 2024-04, Vol.103 (5), p.803-807</ispartof><rights>2024 The Authors. published by Wiley Periodicals LLC.</rights><rights>2024 The Authors. Catheterization and Cardiovascular Interventions published by Wiley Periodicals LLC.</rights><rights>2024. This article is published under http://creativecommons.org/licenses/by-nc/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3551-bdcf35654a76db9929421adce1a6b41794352694d00217ad2c161a41244c0e843</citedby><cites>FETCH-LOGICAL-c3551-bdcf35654a76db9929421adce1a6b41794352694d00217ad2c161a41244c0e843</cites><orcidid>0000-0002-2474-5723 ; 0000-0001-7844-9447 ; 0000-0002-0283-9091 ; 0009-0009-8068-090X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fccd.31001$$EPDF$$P50$$Gwiley$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fccd.31001$$EHTML$$P50$$Gwiley$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,1411,27903,27904,45553,45554</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38415818$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Andréka, Judit</creatorcontrib><creatorcontrib>Sasi, Viktor</creatorcontrib><creatorcontrib>Tóth, Gábor G.</creatorcontrib><creatorcontrib>Ruzsa, Zoltán</creatorcontrib><title>Stent graft implantation from distal radial access—A novel way to treat femoral access site complication during transcatheter aortic valve replacement: A case report</title><title>Catheterization and cardiovascular interventions</title><addtitle>Catheter Cardiovasc Interv</addtitle><description>In this paper, a case of an 82‐year‐old man who was admitted to our department with sever symptomatic degenerative aortic valve stenosis is presented and discussed. After all screening procedures, a successful transfemoral transcatheter aortic valve replacement was performed, but the closure of the femoral access was unsuccessful due to suture‐based device failure. We decided to perform a prolonged balloon dilatation and external compression at the bleeding site, but the bleeding did not stop; therefore, an iCover stent graft was implanted from distal radial artery access using slender technique. Following that, the bleeding was stopped, and the patient had an uneventful outcome.</description><subject>Aortic valve</subject><subject>Balloon treatment</subject><subject>Bleeding</subject><subject>distal radial artery access</subject><subject>femoral access complications</subject><subject>Femur</subject><subject>Implants</subject><subject>Stenosis</subject><subject>transcatheter aortic valve replacement</subject><issn>1522-1946</issn><issn>1522-726X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>24P</sourceid><recordid>eNp1kcFO3DAQhq2qqFDaAy-ARuqphwXbcZykt9XSlkpIHNpKvUWz9gSMknixvYv2xkPwDn0vngRDttx6mtHo0zej-Rk7EvxEcC5PjbEnRe7EG3YgSilnldR_3u560Si9z97HeMM5b7Rs3rH9olairEV9wP7-TDQmuArYJXDDqscxYXJ-hC74AayLCXsIaF0uaAzF-Hj_MIfRb6iHO9xC8pACYYKOBh9eKYguERiflc5MRrsObrzKNI4xj64pUQD0ITkDG-w3BIHyAYaGfNIXmIPB-DLLyAe212Ef6eOuHrLf377-WpzPLi6__1jML2amKEsxW1rTFaUuFVbaLptGNkoKtIYE6qUSVaOKUupG2fw2UaGVRmiBSkilDKdaFYfs0-RdBX-7ppjaG78OY17ZFryoSl1ryTP1eaJM8DEG6tpVcAOGbSt4-xxJmyNpXyLJ7PHOuF4OZF_Jfxlk4HQC7lxP2_-b2sXibFI-AZi1mJ4</recordid><startdate>20240401</startdate><enddate>20240401</enddate><creator>Andréka, Judit</creator><creator>Sasi, Viktor</creator><creator>Tóth, Gábor G.</creator><creator>Ruzsa, Zoltán</creator><general>Wiley Subscription Services, Inc</general><scope>24P</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7T5</scope><scope>7U9</scope><scope>H94</scope><scope>K9.</scope><orcidid>https://orcid.org/0000-0002-2474-5723</orcidid><orcidid>https://orcid.org/0000-0001-7844-9447</orcidid><orcidid>https://orcid.org/0000-0002-0283-9091</orcidid><orcidid>https://orcid.org/0009-0009-8068-090X</orcidid></search><sort><creationdate>20240401</creationdate><title>Stent graft implantation from distal radial access—A novel way to treat femoral access site complication during transcatheter aortic valve replacement: A case report</title><author>Andréka, Judit ; Sasi, Viktor ; Tóth, Gábor G. ; Ruzsa, Zoltán</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3551-bdcf35654a76db9929421adce1a6b41794352694d00217ad2c161a41244c0e843</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Aortic valve</topic><topic>Balloon treatment</topic><topic>Bleeding</topic><topic>distal radial artery access</topic><topic>femoral access complications</topic><topic>Femur</topic><topic>Implants</topic><topic>Stenosis</topic><topic>transcatheter aortic valve replacement</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Andréka, Judit</creatorcontrib><creatorcontrib>Sasi, Viktor</creatorcontrib><creatorcontrib>Tóth, Gábor G.</creatorcontrib><creatorcontrib>Ruzsa, Zoltán</creatorcontrib><collection>Wiley Online Library Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Immunology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><jtitle>Catheterization and cardiovascular interventions</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Andréka, Judit</au><au>Sasi, Viktor</au><au>Tóth, Gábor G.</au><au>Ruzsa, Zoltán</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Stent graft implantation from distal radial access—A novel way to treat femoral access site complication during transcatheter aortic valve replacement: A case report</atitle><jtitle>Catheterization and cardiovascular interventions</jtitle><addtitle>Catheter Cardiovasc Interv</addtitle><date>2024-04-01</date><risdate>2024</risdate><volume>103</volume><issue>5</issue><spage>803</spage><epage>807</epage><pages>803-807</pages><issn>1522-1946</issn><eissn>1522-726X</eissn><abstract>In this paper, a case of an 82‐year‐old man who was admitted to our department with sever symptomatic degenerative aortic valve stenosis is presented and discussed. After all screening procedures, a successful transfemoral transcatheter aortic valve replacement was performed, but the closure of the femoral access was unsuccessful due to suture‐based device failure. We decided to perform a prolonged balloon dilatation and external compression at the bleeding site, but the bleeding did not stop; therefore, an iCover stent graft was implanted from distal radial artery access using slender technique. Following that, the bleeding was stopped, and the patient had an uneventful outcome.</abstract><cop>United States</cop><pub>Wiley Subscription Services, Inc</pub><pmid>38415818</pmid><doi>10.1002/ccd.31001</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0002-2474-5723</orcidid><orcidid>https://orcid.org/0000-0001-7844-9447</orcidid><orcidid>https://orcid.org/0000-0002-0283-9091</orcidid><orcidid>https://orcid.org/0009-0009-8068-090X</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1522-1946 |
ispartof | Catheterization and cardiovascular interventions, 2024-04, Vol.103 (5), p.803-807 |
issn | 1522-1946 1522-726X |
language | eng |
recordid | cdi_proquest_journals_3037568620 |
source | Wiley Online Library Journals Frontfile Complete |
subjects | Aortic valve Balloon treatment Bleeding distal radial artery access femoral access complications Femur Implants Stenosis transcatheter aortic valve replacement |
title | Stent graft implantation from distal radial access—A novel way to treat femoral access site complication during transcatheter aortic valve replacement: A case report |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T11%3A44%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Stent%20graft%20implantation%20from%20distal%20radial%20access%E2%80%94A%20novel%20way%20to%20treat%20femoral%20access%20site%20complication%20during%20transcatheter%20aortic%20valve%20replacement:%20A%20case%20report&rft.jtitle=Catheterization%20and%20cardiovascular%20interventions&rft.au=Andr%C3%A9ka,%20Judit&rft.date=2024-04-01&rft.volume=103&rft.issue=5&rft.spage=803&rft.epage=807&rft.pages=803-807&rft.issn=1522-1946&rft.eissn=1522-726X&rft_id=info:doi/10.1002/ccd.31001&rft_dat=%3Cproquest_cross%3E3037568620%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3037568620&rft_id=info:pmid/38415818&rfr_iscdi=true |