Розрахунок характеристик гібридної енергосистеми з паралельно включеними асинхронним генератором і AC/DC перетворювачем

Hybrid power supply systems (HPSSs) are considered as a good option for electric power supply of remotely located from the grid consumers due to significant fuel savings compared to diesel sets. Quick development and improvement of HPSSs may be achieved using specialized methodologies and programs....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electronics and electromechanics 2024-01 (2), p.67
Hauptverfasser: Mazurenko, L I, Dzhura, O V, Shykhnenko, M O
Format: Artikel
Sprache:eng ; rus ; ukr
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 2
container_start_page 67
container_title Electronics and electromechanics
container_volume
creator Mazurenko, L I
Dzhura, O V
Shykhnenko, M O
description Hybrid power supply systems (HPSSs) are considered as a good option for electric power supply of remotely located from the grid consumers due to significant fuel savings compared to diesel sets. Quick development and improvement of HPSSs may be achieved using specialized methodologies and programs. In the paper a schematicdiagram is proposed and operation principles of a 400 V / 50 Hz HPSS were developed. The system’s main component is the master generating unit of the hydropower plant using a 250 kW induction generator (IG). The voltage of the system is controlled by the controller of the AC/DC power converter. The electrical frequency of the system is controlled by the speed controller of the hydropower turbine. A wind turbine, an energy storage system and a regulated dump load are connected to the IG through the AC/DC converter. Goal.The paper aims to develop a methodology for steady state performance analysis of the hydraulic turbine driven isolated IG operating in parallel through an AC/DC power converter with additional sources and consumers of active power. Methodology. The methodology for evaluation of performance characteristics of the IG operating in the proposed system has been developed. The methodology is based on the equivalent circuit of the system, equations of active and reactive power balance in the system and the superposition method. Results. The equations of frequency, voltage and power regulators of the system are given. The performance characteristics of the IG operating in the system supplying resistive and RL load in «constant voltage – constant frequency» mode are obtained. Novelty. The developed methodology is innovative in taking into account the control algorithms of the system. The comparative analysis of the IG’s performance operating in the stand-alone generating unit and in the generating unit connected to the proposed system is performed. Practical value. The developed methodology can be used for development and performance improvement of hybrid AC power systems.
doi_str_mv 10.20998/2074-272X.2024.2.10
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2955271136</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2955271136</sourcerecordid><originalsourceid>FETCH-LOGICAL-p566-6d95d6f93a30ff2bca215d9721a2be8b41c156ee8c179636e3ee6e2d1a3b568e3</originalsourceid><addsrcrecordid>eNqFTstOAkEQ3BhNJMgfeNjE8-JMz84seyTrMyHxwsEbWWD2QIwgyB00xIvhiFc_YQU3EF7-Qs8P-C32Anr11FVd1VVtWcec5YH5fuEUmOc64MEtcXDzkOdsz8qAYL4jXObuE_51HFq5TqfBGOMCpJCQsb7xHdc4NT2MzcA844rY3DYDorTCuXnChNDM9AnNSMKJGeFHusLP1G3ebEwIpK4J0f7Om-ASZzZObfzaZS1otzCv6ZGNY5wTGZqXzfFsa47Ta1zRIz16Y7UVqPGvIKbg9UZc2mZkF4PTsyAtSLWEtHGqmiHNeJO8PLIOovCuo3O7mbXKF-fl4Mop3VxeB8WS05JKOaruy7qKfBEKFkVQrYXAZd33gIdQ1YWqy2tcKq0LNe75SigttFYa6jwUVakKWmStk21sq9186OrOY6XR7LbvqbECvpTgcS7U_y7GQYkfU7Lazw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2955270126</pqid></control><display><type>article</type><title>Розрахунок характеристик гібридної енергосистеми з паралельно включеними асинхронним генератором і AC/DC перетворювачем</title><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Mazurenko, L I ; Dzhura, O V ; Shykhnenko, M O</creator><creatorcontrib>Mazurenko, L I ; Dzhura, O V ; Shykhnenko, M O</creatorcontrib><description>Hybrid power supply systems (HPSSs) are considered as a good option for electric power supply of remotely located from the grid consumers due to significant fuel savings compared to diesel sets. Quick development and improvement of HPSSs may be achieved using specialized methodologies and programs. In the paper a schematicdiagram is proposed and operation principles of a 400 V / 50 Hz HPSS were developed. The system’s main component is the master generating unit of the hydropower plant using a 250 kW induction generator (IG). The voltage of the system is controlled by the controller of the AC/DC power converter. The electrical frequency of the system is controlled by the speed controller of the hydropower turbine. A wind turbine, an energy storage system and a regulated dump load are connected to the IG through the AC/DC converter. Goal.The paper aims to develop a methodology for steady state performance analysis of the hydraulic turbine driven isolated IG operating in parallel through an AC/DC power converter with additional sources and consumers of active power. Methodology. The methodology for evaluation of performance characteristics of the IG operating in the proposed system has been developed. The methodology is based on the equivalent circuit of the system, equations of active and reactive power balance in the system and the superposition method. Results. The equations of frequency, voltage and power regulators of the system are given. The performance characteristics of the IG operating in the system supplying resistive and RL load in «constant voltage – constant frequency» mode are obtained. Novelty. The developed methodology is innovative in taking into account the control algorithms of the system. The comparative analysis of the IG’s performance operating in the stand-alone generating unit and in the generating unit connected to the proposed system is performed. Practical value. The developed methodology can be used for development and performance improvement of hybrid AC power systems.</description><identifier>ISSN: 2074-272X</identifier><identifier>EISSN: 2309-3404</identifier><identifier>DOI: 10.20998/2074-272X.2024.2.10</identifier><language>eng ; rus ; ukr</language><publisher>Kharkiv: National Technical University, Ukraine</publisher><subject>AC-DC converters ; Algorithms ; Consumers ; Control algorithms ; Controllers ; Diesel fuels ; Electric potential ; Electric power grids ; Electric power supplies ; Electric power systems ; Electrical loads ; Energy storage ; Equivalent circuits ; Hybrid systems ; Hydraulic turbines ; Hydroelectric plants ; Hydroelectric power ; Induction generators ; Mathematical analysis ; Methodology ; Performance evaluation ; Power converters ; Power supply ; Reactive power ; Steady state ; Voltage ; Voltage regulators ; Wind turbines</subject><ispartof>Electronics and electromechanics, 2024-01 (2), p.67</ispartof><rights>2024. This work is published under https://creativecommons.org/licenses/by/4.0/legalcode (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,864,27924,27925</link.rule.ids></links><search><creatorcontrib>Mazurenko, L I</creatorcontrib><creatorcontrib>Dzhura, O V</creatorcontrib><creatorcontrib>Shykhnenko, M O</creatorcontrib><title>Розрахунок характеристик гібридної енергосистеми з паралельно включеними асинхронним генератором і AC/DC перетворювачем</title><title>Electronics and electromechanics</title><description>Hybrid power supply systems (HPSSs) are considered as a good option for electric power supply of remotely located from the grid consumers due to significant fuel savings compared to diesel sets. Quick development and improvement of HPSSs may be achieved using specialized methodologies and programs. In the paper a schematicdiagram is proposed and operation principles of a 400 V / 50 Hz HPSS were developed. The system’s main component is the master generating unit of the hydropower plant using a 250 kW induction generator (IG). The voltage of the system is controlled by the controller of the AC/DC power converter. The electrical frequency of the system is controlled by the speed controller of the hydropower turbine. A wind turbine, an energy storage system and a regulated dump load are connected to the IG through the AC/DC converter. Goal.The paper aims to develop a methodology for steady state performance analysis of the hydraulic turbine driven isolated IG operating in parallel through an AC/DC power converter with additional sources and consumers of active power. Methodology. The methodology for evaluation of performance characteristics of the IG operating in the proposed system has been developed. The methodology is based on the equivalent circuit of the system, equations of active and reactive power balance in the system and the superposition method. Results. The equations of frequency, voltage and power regulators of the system are given. The performance characteristics of the IG operating in the system supplying resistive and RL load in «constant voltage – constant frequency» mode are obtained. Novelty. The developed methodology is innovative in taking into account the control algorithms of the system. The comparative analysis of the IG’s performance operating in the stand-alone generating unit and in the generating unit connected to the proposed system is performed. Practical value. The developed methodology can be used for development and performance improvement of hybrid AC power systems.</description><subject>AC-DC converters</subject><subject>Algorithms</subject><subject>Consumers</subject><subject>Control algorithms</subject><subject>Controllers</subject><subject>Diesel fuels</subject><subject>Electric potential</subject><subject>Electric power grids</subject><subject>Electric power supplies</subject><subject>Electric power systems</subject><subject>Electrical loads</subject><subject>Energy storage</subject><subject>Equivalent circuits</subject><subject>Hybrid systems</subject><subject>Hydraulic turbines</subject><subject>Hydroelectric plants</subject><subject>Hydroelectric power</subject><subject>Induction generators</subject><subject>Mathematical analysis</subject><subject>Methodology</subject><subject>Performance evaluation</subject><subject>Power converters</subject><subject>Power supply</subject><subject>Reactive power</subject><subject>Steady state</subject><subject>Voltage</subject><subject>Voltage regulators</subject><subject>Wind turbines</subject><issn>2074-272X</issn><issn>2309-3404</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>ABUWG</sourceid><sourceid>AZQEC</sourceid><recordid>eNqFTstOAkEQ3BhNJMgfeNjE8-JMz84seyTrMyHxwsEbWWD2QIwgyB00xIvhiFc_YQU3EF7-Qs8P-C32Anr11FVd1VVtWcec5YH5fuEUmOc64MEtcXDzkOdsz8qAYL4jXObuE_51HFq5TqfBGOMCpJCQsb7xHdc4NT2MzcA844rY3DYDorTCuXnChNDM9AnNSMKJGeFHusLP1G3ebEwIpK4J0f7Om-ASZzZObfzaZS1otzCv6ZGNY5wTGZqXzfFsa47Ta1zRIz16Y7UVqPGvIKbg9UZc2mZkF4PTsyAtSLWEtHGqmiHNeJO8PLIOovCuo3O7mbXKF-fl4Mop3VxeB8WS05JKOaruy7qKfBEKFkVQrYXAZd33gIdQ1YWqy2tcKq0LNe75SigttFYa6jwUVakKWmStk21sq9186OrOY6XR7LbvqbECvpTgcS7U_y7GQYkfU7Lazw</recordid><startdate>20240101</startdate><enddate>20240101</enddate><creator>Mazurenko, L I</creator><creator>Dzhura, O V</creator><creator>Shykhnenko, M O</creator><general>National Technical University, Ukraine</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>P5Z</scope><scope>P62</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope><scope>ABUWG</scope><scope>AZQEC</scope><scope>PIMPY</scope></search><sort><creationdate>20240101</creationdate><title>Розрахунок характеристик гібридної енергосистеми з паралельно включеними асинхронним генератором і AC/DC перетворювачем</title><author>Mazurenko, L I ; Dzhura, O V ; Shykhnenko, M O</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p566-6d95d6f93a30ff2bca215d9721a2be8b41c156ee8c179636e3ee6e2d1a3b568e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; rus ; ukr</language><creationdate>2024</creationdate><topic>AC-DC converters</topic><topic>Algorithms</topic><topic>Consumers</topic><topic>Control algorithms</topic><topic>Controllers</topic><topic>Diesel fuels</topic><topic>Electric potential</topic><topic>Electric power grids</topic><topic>Electric power supplies</topic><topic>Electric power systems</topic><topic>Electrical loads</topic><topic>Energy storage</topic><topic>Equivalent circuits</topic><topic>Hybrid systems</topic><topic>Hydraulic turbines</topic><topic>Hydroelectric plants</topic><topic>Hydroelectric power</topic><topic>Induction generators</topic><topic>Mathematical analysis</topic><topic>Methodology</topic><topic>Performance evaluation</topic><topic>Power converters</topic><topic>Power supply</topic><topic>Reactive power</topic><topic>Steady state</topic><topic>Voltage</topic><topic>Voltage regulators</topic><topic>Wind turbines</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mazurenko, L I</creatorcontrib><creatorcontrib>Dzhura, O V</creatorcontrib><creatorcontrib>Shykhnenko, M O</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Advanced Technologies &amp; Aerospace Database</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central Essentials</collection><collection>Publicly Available Content Database</collection><jtitle>Electronics and electromechanics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mazurenko, L I</au><au>Dzhura, O V</au><au>Shykhnenko, M O</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Розрахунок характеристик гібридної енергосистеми з паралельно включеними асинхронним генератором і AC/DC перетворювачем</atitle><jtitle>Electronics and electromechanics</jtitle><date>2024-01-01</date><risdate>2024</risdate><issue>2</issue><spage>67</spage><pages>67-</pages><issn>2074-272X</issn><eissn>2309-3404</eissn><abstract>Hybrid power supply systems (HPSSs) are considered as a good option for electric power supply of remotely located from the grid consumers due to significant fuel savings compared to diesel sets. Quick development and improvement of HPSSs may be achieved using specialized methodologies and programs. In the paper a schematicdiagram is proposed and operation principles of a 400 V / 50 Hz HPSS were developed. The system’s main component is the master generating unit of the hydropower plant using a 250 kW induction generator (IG). The voltage of the system is controlled by the controller of the AC/DC power converter. The electrical frequency of the system is controlled by the speed controller of the hydropower turbine. A wind turbine, an energy storage system and a regulated dump load are connected to the IG through the AC/DC converter. Goal.The paper aims to develop a methodology for steady state performance analysis of the hydraulic turbine driven isolated IG operating in parallel through an AC/DC power converter with additional sources and consumers of active power. Methodology. The methodology for evaluation of performance characteristics of the IG operating in the proposed system has been developed. The methodology is based on the equivalent circuit of the system, equations of active and reactive power balance in the system and the superposition method. Results. The equations of frequency, voltage and power regulators of the system are given. The performance characteristics of the IG operating in the system supplying resistive and RL load in «constant voltage – constant frequency» mode are obtained. Novelty. The developed methodology is innovative in taking into account the control algorithms of the system. The comparative analysis of the IG’s performance operating in the stand-alone generating unit and in the generating unit connected to the proposed system is performed. Practical value. The developed methodology can be used for development and performance improvement of hybrid AC power systems.</abstract><cop>Kharkiv</cop><pub>National Technical University, Ukraine</pub><doi>10.20998/2074-272X.2024.2.10</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2074-272X
ispartof Electronics and electromechanics, 2024-01 (2), p.67
issn 2074-272X
2309-3404
language eng ; rus ; ukr
recordid cdi_proquest_journals_2955271136
source DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals
subjects AC-DC converters
Algorithms
Consumers
Control algorithms
Controllers
Diesel fuels
Electric potential
Electric power grids
Electric power supplies
Electric power systems
Electrical loads
Energy storage
Equivalent circuits
Hybrid systems
Hydraulic turbines
Hydroelectric plants
Hydroelectric power
Induction generators
Mathematical analysis
Methodology
Performance evaluation
Power converters
Power supply
Reactive power
Steady state
Voltage
Voltage regulators
Wind turbines
title Розрахунок характеристик гібридної енергосистеми з паралельно включеними асинхронним генератором і AC/DC перетворювачем
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T05%3A32%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=%D0%A0%D0%BE%D0%B7%D1%80%D0%B0%D1%85%D1%83%D0%BD%D0%BE%D0%BA%20%D1%85%D0%B0%D1%80%D0%B0%D0%BA%D1%82%D0%B5%D1%80%D0%B8%D1%81%D1%82%D0%B8%D0%BA%20%D0%B3%D1%96%D0%B1%D1%80%D0%B8%D0%B4%D0%BD%D0%BE%D1%97%20%D0%B5%D0%BD%D0%B5%D1%80%D0%B3%D0%BE%D1%81%D0%B8%D1%81%D1%82%D0%B5%D0%BC%D0%B8%20%D0%B7%20%D0%BF%D0%B0%D1%80%D0%B0%D0%BB%D0%B5%D0%BB%D1%8C%D0%BD%D0%BE%20%D0%B2%D0%BA%D0%BB%D1%8E%D1%87%D0%B5%D0%BD%D0%B8%D0%BC%D0%B8%20%D0%B0%D1%81%D0%B8%D0%BD%D1%85%D1%80%D0%BE%D0%BD%D0%BD%D0%B8%D0%BC%20%D0%B3%D0%B5%D0%BD%D0%B5%D1%80%D0%B0%D1%82%D0%BE%D1%80%D0%BE%D0%BC%20%D1%96%20AC/DC%20%D0%BF%D0%B5%D1%80%D0%B5%D1%82%D0%B2%D0%BE%D1%80%D1%8E%D0%B2%D0%B0%D1%87%D0%B5%D0%BC&rft.jtitle=Electronics%20and%20electromechanics&rft.au=Mazurenko,%20L%20I&rft.date=2024-01-01&rft.issue=2&rft.spage=67&rft.pages=67-&rft.issn=2074-272X&rft.eissn=2309-3404&rft_id=info:doi/10.20998/2074-272X.2024.2.10&rft_dat=%3Cproquest%3E2955271136%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2955270126&rft_id=info:pmid/&rfr_iscdi=true