Reply to “Errors in the description of USP certified reference materials”

If we add to our stated uncertainty a term that includes bottle-to-bottle variability, the maximum effect for our current four CRMs would be to increase the stated uncertainty by 1.6%. [...]our reported uncertainty is not simply the standard deviation of the mean of the 3 laboratory means, but rathe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Accreditation and quality assurance 2011-07, Vol.16 (7), p.385-386
Hauptverfasser: Koch, William F., Ma, Bei
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 386
container_issue 7
container_start_page 385
container_title Accreditation and quality assurance
container_volume 16
creator Koch, William F.
Ma, Bei
description If we add to our stated uncertainty a term that includes bottle-to-bottle variability, the maximum effect for our current four CRMs would be to increase the stated uncertainty by 1.6%. [...]our reported uncertainty is not simply the standard deviation of the mean of the 3 laboratory means, but rather it includes a complete assessment of all components of uncertainty, both random and systematic. Furthermore, we do not concern ourselves only with the mechanical application of and compliance with the words of the ISO Guides, but rather we adhere to the spirit and intent of the ISO–REMCO series of ISO Guides, specifically that the provider of the certified reference material must have full understanding and awareness of all the known and suspected sources of bias and uncertainty that may affect the trueness of an assigned value as stated in the Certificate of Analysis.
doi_str_mv 10.1007/s00769-011-0777-y
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2917988121</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2917988121</sourcerecordid><originalsourceid>FETCH-LOGICAL-c268t-6942d7df3ab36e59568f1a4676f0007b5cd4d4b525cf1696743b3e91f2bdc4c13</originalsourceid><addsrcrecordid>eNp1kE1OwzAQhS0EEqVwAHaWWBs8jn_iJarKj1QEArq2EseGVG0S7LDIrgeBy_UkuAoSKzYzs3jvzcyH0DnQS6BUXcVUpCYUgFClFBkO0AR4xggVoA7RhGquCSgljtFJjCtKQeSQTdDDs-vWA-5bvNt-zUNoQ8R1g_t3hysXbai7vm4b3Hq8fHnC1oW-9rWrcHDeBddYhzdF70JdrONu-32Kjnya3Nlvn6Llzfx1dkcWj7f3s-sFsUzmPZGas0pVPivKTDqhhcw9FFwq6Wn6oxS24hUvBRPWg9RS8azMnAbPyspyC9kUXYy5XWg_Pl3szar9DE1aaZgGpfMc2F4Fo8qGNsZ0selCvSnCYICaPTUzUjOJmtlTM0PysNETk7Z5c-Ev-X_TDzqRcWg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2917988121</pqid></control><display><type>article</type><title>Reply to “Errors in the description of USP certified reference materials”</title><source>SpringerLink Journals - AutoHoldings</source><source>ProQuest Central</source><creator>Koch, William F. ; Ma, Bei</creator><creatorcontrib>Koch, William F. ; Ma, Bei</creatorcontrib><description>If we add to our stated uncertainty a term that includes bottle-to-bottle variability, the maximum effect for our current four CRMs would be to increase the stated uncertainty by 1.6%. [...]our reported uncertainty is not simply the standard deviation of the mean of the 3 laboratory means, but rather it includes a complete assessment of all components of uncertainty, both random and systematic. Furthermore, we do not concern ourselves only with the mechanical application of and compliance with the words of the ISO Guides, but rather we adhere to the spirit and intent of the ISO–REMCO series of ISO Guides, specifically that the provider of the certified reference material must have full understanding and awareness of all the known and suspected sources of bias and uncertainty that may affect the trueness of an assigned value as stated in the Certificate of Analysis.</description><identifier>ISSN: 0949-1775</identifier><identifier>EISSN: 1432-0517</identifier><identifier>DOI: 10.1007/s00769-011-0777-y</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer-Verlag</publisher><subject>Analytical Chemistry ; Biochemistry ; Chemistry ; Chemistry and Materials Science ; Commercial Law ; Ecotoxicology ; Food Science ; Letter to the Editor ; Marketing ; Reference materials ; Uncertainty</subject><ispartof>Accreditation and quality assurance, 2011-07, Vol.16 (7), p.385-386</ispartof><rights>Springer-Verlag 2011</rights><rights>Springer-Verlag 2011.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c268t-6942d7df3ab36e59568f1a4676f0007b5cd4d4b525cf1696743b3e91f2bdc4c13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00769-011-0777-y$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2917988121?pq-origsite=primo$$EHTML$$P50$$Gproquest$$H</linktohtml><link.rule.ids>314,776,780,21367,27901,27902,33721,41464,42533,43781,51294</link.rule.ids></links><search><creatorcontrib>Koch, William F.</creatorcontrib><creatorcontrib>Ma, Bei</creatorcontrib><title>Reply to “Errors in the description of USP certified reference materials”</title><title>Accreditation and quality assurance</title><addtitle>Accred Qual Assur</addtitle><description>If we add to our stated uncertainty a term that includes bottle-to-bottle variability, the maximum effect for our current four CRMs would be to increase the stated uncertainty by 1.6%. [...]our reported uncertainty is not simply the standard deviation of the mean of the 3 laboratory means, but rather it includes a complete assessment of all components of uncertainty, both random and systematic. Furthermore, we do not concern ourselves only with the mechanical application of and compliance with the words of the ISO Guides, but rather we adhere to the spirit and intent of the ISO–REMCO series of ISO Guides, specifically that the provider of the certified reference material must have full understanding and awareness of all the known and suspected sources of bias and uncertainty that may affect the trueness of an assigned value as stated in the Certificate of Analysis.</description><subject>Analytical Chemistry</subject><subject>Biochemistry</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Commercial Law</subject><subject>Ecotoxicology</subject><subject>Food Science</subject><subject>Letter to the Editor</subject><subject>Marketing</subject><subject>Reference materials</subject><subject>Uncertainty</subject><issn>0949-1775</issn><issn>1432-0517</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>BENPR</sourceid><recordid>eNp1kE1OwzAQhS0EEqVwAHaWWBs8jn_iJarKj1QEArq2EseGVG0S7LDIrgeBy_UkuAoSKzYzs3jvzcyH0DnQS6BUXcVUpCYUgFClFBkO0AR4xggVoA7RhGquCSgljtFJjCtKQeSQTdDDs-vWA-5bvNt-zUNoQ8R1g_t3hysXbai7vm4b3Hq8fHnC1oW-9rWrcHDeBddYhzdF70JdrONu-32Kjnya3Nlvn6Llzfx1dkcWj7f3s-sFsUzmPZGas0pVPivKTDqhhcw9FFwq6Wn6oxS24hUvBRPWg9RS8azMnAbPyspyC9kUXYy5XWg_Pl3szar9DE1aaZgGpfMc2F4Fo8qGNsZ0selCvSnCYICaPTUzUjOJmtlTM0PysNETk7Z5c-Ev-X_TDzqRcWg</recordid><startdate>20110701</startdate><enddate>20110701</enddate><creator>Koch, William F.</creator><creator>Ma, Bei</creator><general>Springer-Verlag</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7XB</scope><scope>88C</scope><scope>8FE</scope><scope>8FG</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>HCIFZ</scope><scope>KB.</scope><scope>M0T</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope></search><sort><creationdate>20110701</creationdate><title>Reply to “Errors in the description of USP certified reference materials”</title><author>Koch, William F. ; Ma, Bei</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c268t-6942d7df3ab36e59568f1a4676f0007b5cd4d4b525cf1696743b3e91f2bdc4c13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Analytical Chemistry</topic><topic>Biochemistry</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Commercial Law</topic><topic>Ecotoxicology</topic><topic>Food Science</topic><topic>Letter to the Editor</topic><topic>Marketing</topic><topic>Reference materials</topic><topic>Uncertainty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Koch, William F.</creatorcontrib><creatorcontrib>Ma, Bei</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Healthcare Administration Database (Alumni)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>SciTech Premium Collection</collection><collection>Materials Science Database</collection><collection>Healthcare Administration Database</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><jtitle>Accreditation and quality assurance</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Koch, William F.</au><au>Ma, Bei</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reply to “Errors in the description of USP certified reference materials”</atitle><jtitle>Accreditation and quality assurance</jtitle><stitle>Accred Qual Assur</stitle><date>2011-07-01</date><risdate>2011</risdate><volume>16</volume><issue>7</issue><spage>385</spage><epage>386</epage><pages>385-386</pages><issn>0949-1775</issn><eissn>1432-0517</eissn><abstract>If we add to our stated uncertainty a term that includes bottle-to-bottle variability, the maximum effect for our current four CRMs would be to increase the stated uncertainty by 1.6%. [...]our reported uncertainty is not simply the standard deviation of the mean of the 3 laboratory means, but rather it includes a complete assessment of all components of uncertainty, both random and systematic. Furthermore, we do not concern ourselves only with the mechanical application of and compliance with the words of the ISO Guides, but rather we adhere to the spirit and intent of the ISO–REMCO series of ISO Guides, specifically that the provider of the certified reference material must have full understanding and awareness of all the known and suspected sources of bias and uncertainty that may affect the trueness of an assigned value as stated in the Certificate of Analysis.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer-Verlag</pub><doi>10.1007/s00769-011-0777-y</doi><tpages>2</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0949-1775
ispartof Accreditation and quality assurance, 2011-07, Vol.16 (7), p.385-386
issn 0949-1775
1432-0517
language eng
recordid cdi_proquest_journals_2917988121
source SpringerLink Journals - AutoHoldings; ProQuest Central
subjects Analytical Chemistry
Biochemistry
Chemistry
Chemistry and Materials Science
Commercial Law
Ecotoxicology
Food Science
Letter to the Editor
Marketing
Reference materials
Uncertainty
title Reply to “Errors in the description of USP certified reference materials”
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-06T23%3A22%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reply%20to%20%E2%80%9CErrors%20in%20the%20description%20of%20USP%20certified%20reference%20materials%E2%80%9D&rft.jtitle=Accreditation%20and%20quality%20assurance&rft.au=Koch,%20William%20F.&rft.date=2011-07-01&rft.volume=16&rft.issue=7&rft.spage=385&rft.epage=386&rft.pages=385-386&rft.issn=0949-1775&rft.eissn=1432-0517&rft_id=info:doi/10.1007/s00769-011-0777-y&rft_dat=%3Cproquest_cross%3E2917988121%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2917988121&rft_id=info:pmid/&rfr_iscdi=true