Proficiency tests to evaluate commercially available IVD kits for glucose and cholesterol measurements

The first proficiency testing round 630-IL-1002, was carried out with a Reference Material DMR-180a with reference values obtained by using gas chromatography isotope dilution mass spectrometry methods, in which glucose, cholesterol and creatinine were measured. The serum pool was obtained from bloo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Accreditation and quality assurance 2009-05, Vol.14 (5), p.269-271
Hauptverfasser: Urquiza, Melina Pérez, Mitani, Yoshito, Jaimes, Hector O. Nava
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 271
container_issue 5
container_start_page 269
container_title Accreditation and quality assurance
container_volume 14
creator Urquiza, Melina Pérez
Mitani, Yoshito
Jaimes, Hector O. Nava
description The first proficiency testing round 630-IL-1002, was carried out with a Reference Material DMR-180a with reference values obtained by using gas chromatography isotope dilution mass spectrometry methods, in which glucose, cholesterol and creatinine were measured. The serum pool was obtained from blood donors and all the analytes were at the normal concentration in Mexican population. The laboratories participants used different field methods to measure the analytes. The Mexican compulsory standard NOM-064-SSA1-1993 “specifications for equipments in vitro diagnostic (IVD)” requests 5% precision and 5% maximum bias of the IVD equipments in the measurements of analytes like glucose and cholesterol. The results obtained by field laboratories in the proficiency testing round are compared to the reference value and uncertainty provided by the National Metrology Institute (CENAM). The quality of measurements is dependent not only on the laboratory competence but also on the methods used by those commercially available IVD kits. It is concluded that quality assessment of measurements in clinical laboratories should be critically evaluated by using stable and certified reference materials.
doi_str_mv 10.1007/s00769-009-0493-z
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2917947815</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2917947815</sourcerecordid><originalsourceid>FETCH-LOGICAL-c346t-50e82bd933af974da3c34baec622a3c099be2e00916ff20189bfac1dfc1d62053</originalsourceid><addsrcrecordid>eNp1kE1LAzEQhoMoWKs_wFtAPK7mYz-ao9SvQkEP6jXMZie6mt3UZFeov96UFj15mElInnln5iXklLMLzlh1GVMqVcZYilzJ7HuPTHguRcYKXu2TCVO5ynhVFYfkKMZ3xngx43JC7GPwtjUt9mZNB4xDpIOn-AVuhAGp8V2HwbTg3JrCF7QOaod08XJNP9rEWh_oqxuNj0ihb6h58y6JYPCOdghxDNhhP8RjcmDBRTzZnVPyfHvzNL_Plg93i_nVMjMyL4esYDgTdaOkBKuqvAGZ3mtAUwqR7kypGgWmJXlprWB8pmoLhjc2RSlYIafkbKu7Cv5zTJPodz-GPrXUQvFK5dWMbyi-pUzwMQa0ehXaDsJac6Y3duqtnTp10hs79XeqOd8pQzTgbIDetPG3UPA8Z0LKxIktF9NX_4rhb4L_xX8AyD2HVQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2917947815</pqid></control><display><type>article</type><title>Proficiency tests to evaluate commercially available IVD kits for glucose and cholesterol measurements</title><source>SpringerLink Journals - AutoHoldings</source><source>ProQuest Central</source><creator>Urquiza, Melina Pérez ; Mitani, Yoshito ; Jaimes, Hector O. Nava</creator><creatorcontrib>Urquiza, Melina Pérez ; Mitani, Yoshito ; Jaimes, Hector O. Nava</creatorcontrib><description>The first proficiency testing round 630-IL-1002, was carried out with a Reference Material DMR-180a with reference values obtained by using gas chromatography isotope dilution mass spectrometry methods, in which glucose, cholesterol and creatinine were measured. The serum pool was obtained from blood donors and all the analytes were at the normal concentration in Mexican population. The laboratories participants used different field methods to measure the analytes. The Mexican compulsory standard NOM-064-SSA1-1993 “specifications for equipments in vitro diagnostic (IVD)” requests 5% precision and 5% maximum bias of the IVD equipments in the measurements of analytes like glucose and cholesterol. The results obtained by field laboratories in the proficiency testing round are compared to the reference value and uncertainty provided by the National Metrology Institute (CENAM). The quality of measurements is dependent not only on the laboratory competence but also on the methods used by those commercially available IVD kits. It is concluded that quality assessment of measurements in clinical laboratories should be critically evaluated by using stable and certified reference materials.</description><identifier>ISSN: 0949-1775</identifier><identifier>EISSN: 1432-0517</identifier><identifier>DOI: 10.1007/s00769-009-0493-z</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer-Verlag</publisher><subject>Analytical Chemistry ; Bias ; Biochemistry ; Calibration ; Chemistry ; Chemistry and Materials Science ; Cholesterol ; Chromatographic methods and physical methods associated with chromatography ; Commercial Law ; Creatinine ; Dilution ; Ecotoxicology ; Evaluation ; Exact sciences and technology ; Food Science ; Gas chromatographic methods ; Gas chromatography ; Glucose ; Marketing ; Mass spectrometry ; Medical laboratories ; Practitioner's Report ; Quality assessment ; Reference materials ; Spectrometric and optical methods</subject><ispartof>Accreditation and quality assurance, 2009-05, Vol.14 (5), p.269-271</ispartof><rights>Springer-Verlag 2009</rights><rights>2009 INIST-CNRS</rights><rights>Springer-Verlag 2009.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c346t-50e82bd933af974da3c34baec622a3c099be2e00916ff20189bfac1dfc1d62053</citedby><cites>FETCH-LOGICAL-c346t-50e82bd933af974da3c34baec622a3c099be2e00916ff20189bfac1dfc1d62053</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00769-009-0493-z$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2917947815?pq-origsite=primo$$EHTML$$P50$$Gproquest$$H</linktohtml><link.rule.ids>314,776,780,21369,27903,27904,33723,41467,42536,43784,51297</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=21440233$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Urquiza, Melina Pérez</creatorcontrib><creatorcontrib>Mitani, Yoshito</creatorcontrib><creatorcontrib>Jaimes, Hector O. Nava</creatorcontrib><title>Proficiency tests to evaluate commercially available IVD kits for glucose and cholesterol measurements</title><title>Accreditation and quality assurance</title><addtitle>Accred Qual Assur</addtitle><description>The first proficiency testing round 630-IL-1002, was carried out with a Reference Material DMR-180a with reference values obtained by using gas chromatography isotope dilution mass spectrometry methods, in which glucose, cholesterol and creatinine were measured. The serum pool was obtained from blood donors and all the analytes were at the normal concentration in Mexican population. The laboratories participants used different field methods to measure the analytes. The Mexican compulsory standard NOM-064-SSA1-1993 “specifications for equipments in vitro diagnostic (IVD)” requests 5% precision and 5% maximum bias of the IVD equipments in the measurements of analytes like glucose and cholesterol. The results obtained by field laboratories in the proficiency testing round are compared to the reference value and uncertainty provided by the National Metrology Institute (CENAM). The quality of measurements is dependent not only on the laboratory competence but also on the methods used by those commercially available IVD kits. It is concluded that quality assessment of measurements in clinical laboratories should be critically evaluated by using stable and certified reference materials.</description><subject>Analytical Chemistry</subject><subject>Bias</subject><subject>Biochemistry</subject><subject>Calibration</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Cholesterol</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Commercial Law</subject><subject>Creatinine</subject><subject>Dilution</subject><subject>Ecotoxicology</subject><subject>Evaluation</subject><subject>Exact sciences and technology</subject><subject>Food Science</subject><subject>Gas chromatographic methods</subject><subject>Gas chromatography</subject><subject>Glucose</subject><subject>Marketing</subject><subject>Mass spectrometry</subject><subject>Medical laboratories</subject><subject>Practitioner's Report</subject><subject>Quality assessment</subject><subject>Reference materials</subject><subject>Spectrometric and optical methods</subject><issn>0949-1775</issn><issn>1432-0517</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>BENPR</sourceid><recordid>eNp1kE1LAzEQhoMoWKs_wFtAPK7mYz-ao9SvQkEP6jXMZie6mt3UZFeov96UFj15mElInnln5iXklLMLzlh1GVMqVcZYilzJ7HuPTHguRcYKXu2TCVO5ynhVFYfkKMZ3xngx43JC7GPwtjUt9mZNB4xDpIOn-AVuhAGp8V2HwbTg3JrCF7QOaod08XJNP9rEWh_oqxuNj0ihb6h58y6JYPCOdghxDNhhP8RjcmDBRTzZnVPyfHvzNL_Plg93i_nVMjMyL4esYDgTdaOkBKuqvAGZ3mtAUwqR7kypGgWmJXlprWB8pmoLhjc2RSlYIafkbKu7Cv5zTJPodz-GPrXUQvFK5dWMbyi-pUzwMQa0ehXaDsJac6Y3duqtnTp10hs79XeqOd8pQzTgbIDetPG3UPA8Z0LKxIktF9NX_4rhb4L_xX8AyD2HVQ</recordid><startdate>20090501</startdate><enddate>20090501</enddate><creator>Urquiza, Melina Pérez</creator><creator>Mitani, Yoshito</creator><creator>Jaimes, Hector O. Nava</creator><general>Springer-Verlag</general><general>Springer</general><general>Springer Nature B.V</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7XB</scope><scope>88C</scope><scope>8FE</scope><scope>8FG</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>HCIFZ</scope><scope>KB.</scope><scope>M0T</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope></search><sort><creationdate>20090501</creationdate><title>Proficiency tests to evaluate commercially available IVD kits for glucose and cholesterol measurements</title><author>Urquiza, Melina Pérez ; Mitani, Yoshito ; Jaimes, Hector O. Nava</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c346t-50e82bd933af974da3c34baec622a3c099be2e00916ff20189bfac1dfc1d62053</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Analytical Chemistry</topic><topic>Bias</topic><topic>Biochemistry</topic><topic>Calibration</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Cholesterol</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Commercial Law</topic><topic>Creatinine</topic><topic>Dilution</topic><topic>Ecotoxicology</topic><topic>Evaluation</topic><topic>Exact sciences and technology</topic><topic>Food Science</topic><topic>Gas chromatographic methods</topic><topic>Gas chromatography</topic><topic>Glucose</topic><topic>Marketing</topic><topic>Mass spectrometry</topic><topic>Medical laboratories</topic><topic>Practitioner's Report</topic><topic>Quality assessment</topic><topic>Reference materials</topic><topic>Spectrometric and optical methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Urquiza, Melina Pérez</creatorcontrib><creatorcontrib>Mitani, Yoshito</creatorcontrib><creatorcontrib>Jaimes, Hector O. Nava</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Healthcare Administration Database (Alumni)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>SciTech Premium Collection</collection><collection>Materials Science Database</collection><collection>Healthcare Administration Database</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><jtitle>Accreditation and quality assurance</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Urquiza, Melina Pérez</au><au>Mitani, Yoshito</au><au>Jaimes, Hector O. Nava</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Proficiency tests to evaluate commercially available IVD kits for glucose and cholesterol measurements</atitle><jtitle>Accreditation and quality assurance</jtitle><stitle>Accred Qual Assur</stitle><date>2009-05-01</date><risdate>2009</risdate><volume>14</volume><issue>5</issue><spage>269</spage><epage>271</epage><pages>269-271</pages><issn>0949-1775</issn><eissn>1432-0517</eissn><abstract>The first proficiency testing round 630-IL-1002, was carried out with a Reference Material DMR-180a with reference values obtained by using gas chromatography isotope dilution mass spectrometry methods, in which glucose, cholesterol and creatinine were measured. The serum pool was obtained from blood donors and all the analytes were at the normal concentration in Mexican population. The laboratories participants used different field methods to measure the analytes. The Mexican compulsory standard NOM-064-SSA1-1993 “specifications for equipments in vitro diagnostic (IVD)” requests 5% precision and 5% maximum bias of the IVD equipments in the measurements of analytes like glucose and cholesterol. The results obtained by field laboratories in the proficiency testing round are compared to the reference value and uncertainty provided by the National Metrology Institute (CENAM). The quality of measurements is dependent not only on the laboratory competence but also on the methods used by those commercially available IVD kits. It is concluded that quality assessment of measurements in clinical laboratories should be critically evaluated by using stable and certified reference materials.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer-Verlag</pub><doi>10.1007/s00769-009-0493-z</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0949-1775
ispartof Accreditation and quality assurance, 2009-05, Vol.14 (5), p.269-271
issn 0949-1775
1432-0517
language eng
recordid cdi_proquest_journals_2917947815
source SpringerLink Journals - AutoHoldings; ProQuest Central
subjects Analytical Chemistry
Bias
Biochemistry
Calibration
Chemistry
Chemistry and Materials Science
Cholesterol
Chromatographic methods and physical methods associated with chromatography
Commercial Law
Creatinine
Dilution
Ecotoxicology
Evaluation
Exact sciences and technology
Food Science
Gas chromatographic methods
Gas chromatography
Glucose
Marketing
Mass spectrometry
Medical laboratories
Practitioner's Report
Quality assessment
Reference materials
Spectrometric and optical methods
title Proficiency tests to evaluate commercially available IVD kits for glucose and cholesterol measurements
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T21%3A51%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Proficiency%20tests%20to%20evaluate%20commercially%20available%20IVD%20kits%20for%20glucose%20and%20cholesterol%20measurements&rft.jtitle=Accreditation%20and%20quality%20assurance&rft.au=Urquiza,%20Melina%20P%C3%A9rez&rft.date=2009-05-01&rft.volume=14&rft.issue=5&rft.spage=269&rft.epage=271&rft.pages=269-271&rft.issn=0949-1775&rft.eissn=1432-0517&rft_id=info:doi/10.1007/s00769-009-0493-z&rft_dat=%3Cproquest_cross%3E2917947815%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2917947815&rft_id=info:pmid/&rfr_iscdi=true