A High-Resolution Film-Resistance Plantar Pressure Sensor
It is a crucial point to monitor real-time plantar pressure for application in physical condition assessment and sports injury diagnosis. In this work, we report a high-resolution (sensitive points number of 187) plantar pressure sensor (PPS) array based on the piezoresistive principle. It consists...
Gespeichert in:
Veröffentlicht in: | IEEE sensors journal 2023-12, Vol.23 (24), p.30213-30221 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 30221 |
---|---|
container_issue | 24 |
container_start_page | 30213 |
container_title | IEEE sensors journal |
container_volume | 23 |
creator | Wang, Zhonghao Zhao, Tiankai Qu, Chunchun Zhang, Rui Li, Zhen Bai, Xianxu He, Zhizhu |
description | It is a crucial point to monitor real-time plantar pressure for application in physical condition assessment and sports injury diagnosis. In this work, we report a high-resolution (sensitive points number of 187) plantar pressure sensor (PPS) array based on the piezoresistive principle. It consists of a force-sensitive film (FSF) and a network of orthogonal conductive threads on both sides. The PPS could achieve a sensitivity of 0.124 kPa−1, a measurement range of up to 50 kPa, and excellent stability. An intelligent insole system consisting of a centimeter-level resolution PPS array, wireless Bluetooth transmitter data acquisition system, and wireless receiving terminal intelligent system is established to monitor and map the plantar pressure in real time. This intelligent insole system can identify various standing and sports positions, which is a terrific way to monitor health, avoid injuries, and train athletes. |
doi_str_mv | 10.1109/JSEN.2023.3329879 |
format | Article |
fullrecord | <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_proquest_journals_2902126159</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>10314442</ieee_id><sourcerecordid>2902126159</sourcerecordid><originalsourceid>FETCH-LOGICAL-c246t-53b2c75c9615a00f20b0d281910857a907ad8c5440c1f92a56658c2170222ab73</originalsourceid><addsrcrecordid>eNpNkMFKAzEQhoMoWKsPIHhY8Lx1ZpJsNsdSWqsULVbBW0jTrG5pd2uye_Dt3aU9eJoZ-P5_4GPsFmGECPrheTV9GREQH3FOOlf6jA1QyjxFJfLzfueQCq4-L9lVjFsA1EqqAdPjZF5-fadvPta7tinrKpmVu31_l7GxlfPJcmerxoZkGXyMbfDJylexDtfsorC76G9Oc8g-ZtP3yTxdvD4-TcaL1JHImlTyNTklnc5QWoCCYA0bylEj5FJZDcpucieFAIeFJiuzTOaOUAER2bXiQ3Z_7D2E-qf1sTHbug1V99KQBkLqinVH4ZFyoY4x-MIcQrm34dcgmN6Q6Q2Z3pA5Geoyd8dM6b3_x3MUQhD_A74SX5s</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2902126159</pqid></control><display><type>article</type><title>A High-Resolution Film-Resistance Plantar Pressure Sensor</title><source>IEEE Electronic Library (IEL)</source><creator>Wang, Zhonghao ; Zhao, Tiankai ; Qu, Chunchun ; Zhang, Rui ; Li, Zhen ; Bai, Xianxu ; He, Zhizhu</creator><creatorcontrib>Wang, Zhonghao ; Zhao, Tiankai ; Qu, Chunchun ; Zhang, Rui ; Li, Zhen ; Bai, Xianxu ; He, Zhizhu</creatorcontrib><description>It is a crucial point to monitor real-time plantar pressure for application in physical condition assessment and sports injury diagnosis. In this work, we report a high-resolution (sensitive points number of 187) plantar pressure sensor (PPS) array based on the piezoresistive principle. It consists of a force-sensitive film (FSF) and a network of orthogonal conductive threads on both sides. The PPS could achieve a sensitivity of 0.124 kPa−1, a measurement range of up to 50 kPa, and excellent stability. An intelligent insole system consisting of a centimeter-level resolution PPS array, wireless Bluetooth transmitter data acquisition system, and wireless receiving terminal intelligent system is established to monitor and map the plantar pressure in real time. This intelligent insole system can identify various standing and sports positions, which is a terrific way to monitor health, avoid injuries, and train athletes.</description><identifier>ISSN: 1530-437X</identifier><identifier>EISSN: 1558-1748</identifier><identifier>DOI: 10.1109/JSEN.2023.3329879</identifier><identifier>CODEN: ISJEAZ</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Biomedical monitoring ; Bluetooth ; Data acquisition ; High resolution ; High-resolution imaging ; Immune system ; Injury prevention ; Insoles ; intelligent insole system ; Monitoring ; piezoresistive principle ; Plantar pressure ; plantar pressure monitoring ; Pressure sensors ; Real time ; Sensor arrays ; Sensors ; Surface resistance ; Temperature sensors</subject><ispartof>IEEE sensors journal, 2023-12, Vol.23 (24), p.30213-30221</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2023</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c246t-53b2c75c9615a00f20b0d281910857a907ad8c5440c1f92a56658c2170222ab73</cites><orcidid>0000-0003-4477-8335 ; 0000-0001-8861-9964</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/10314442$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,778,782,794,27907,27908,54741</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/10314442$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Wang, Zhonghao</creatorcontrib><creatorcontrib>Zhao, Tiankai</creatorcontrib><creatorcontrib>Qu, Chunchun</creatorcontrib><creatorcontrib>Zhang, Rui</creatorcontrib><creatorcontrib>Li, Zhen</creatorcontrib><creatorcontrib>Bai, Xianxu</creatorcontrib><creatorcontrib>He, Zhizhu</creatorcontrib><title>A High-Resolution Film-Resistance Plantar Pressure Sensor</title><title>IEEE sensors journal</title><addtitle>JSEN</addtitle><description>It is a crucial point to monitor real-time plantar pressure for application in physical condition assessment and sports injury diagnosis. In this work, we report a high-resolution (sensitive points number of 187) plantar pressure sensor (PPS) array based on the piezoresistive principle. It consists of a force-sensitive film (FSF) and a network of orthogonal conductive threads on both sides. The PPS could achieve a sensitivity of 0.124 kPa−1, a measurement range of up to 50 kPa, and excellent stability. An intelligent insole system consisting of a centimeter-level resolution PPS array, wireless Bluetooth transmitter data acquisition system, and wireless receiving terminal intelligent system is established to monitor and map the plantar pressure in real time. This intelligent insole system can identify various standing and sports positions, which is a terrific way to monitor health, avoid injuries, and train athletes.</description><subject>Biomedical monitoring</subject><subject>Bluetooth</subject><subject>Data acquisition</subject><subject>High resolution</subject><subject>High-resolution imaging</subject><subject>Immune system</subject><subject>Injury prevention</subject><subject>Insoles</subject><subject>intelligent insole system</subject><subject>Monitoring</subject><subject>piezoresistive principle</subject><subject>Plantar pressure</subject><subject>plantar pressure monitoring</subject><subject>Pressure sensors</subject><subject>Real time</subject><subject>Sensor arrays</subject><subject>Sensors</subject><subject>Surface resistance</subject><subject>Temperature sensors</subject><issn>1530-437X</issn><issn>1558-1748</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNpNkMFKAzEQhoMoWKsPIHhY8Lx1ZpJsNsdSWqsULVbBW0jTrG5pd2uye_Dt3aU9eJoZ-P5_4GPsFmGECPrheTV9GREQH3FOOlf6jA1QyjxFJfLzfueQCq4-L9lVjFsA1EqqAdPjZF5-fadvPta7tinrKpmVu31_l7GxlfPJcmerxoZkGXyMbfDJylexDtfsorC76G9Oc8g-ZtP3yTxdvD4-TcaL1JHImlTyNTklnc5QWoCCYA0bylEj5FJZDcpucieFAIeFJiuzTOaOUAER2bXiQ3Z_7D2E-qf1sTHbug1V99KQBkLqinVH4ZFyoY4x-MIcQrm34dcgmN6Q6Q2Z3pA5Geoyd8dM6b3_x3MUQhD_A74SX5s</recordid><startdate>20231215</startdate><enddate>20231215</enddate><creator>Wang, Zhonghao</creator><creator>Zhao, Tiankai</creator><creator>Qu, Chunchun</creator><creator>Zhang, Rui</creator><creator>Li, Zhen</creator><creator>Bai, Xianxu</creator><creator>He, Zhizhu</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0003-4477-8335</orcidid><orcidid>https://orcid.org/0000-0001-8861-9964</orcidid></search><sort><creationdate>20231215</creationdate><title>A High-Resolution Film-Resistance Plantar Pressure Sensor</title><author>Wang, Zhonghao ; Zhao, Tiankai ; Qu, Chunchun ; Zhang, Rui ; Li, Zhen ; Bai, Xianxu ; He, Zhizhu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c246t-53b2c75c9615a00f20b0d281910857a907ad8c5440c1f92a56658c2170222ab73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Biomedical monitoring</topic><topic>Bluetooth</topic><topic>Data acquisition</topic><topic>High resolution</topic><topic>High-resolution imaging</topic><topic>Immune system</topic><topic>Injury prevention</topic><topic>Insoles</topic><topic>intelligent insole system</topic><topic>Monitoring</topic><topic>piezoresistive principle</topic><topic>Plantar pressure</topic><topic>plantar pressure monitoring</topic><topic>Pressure sensors</topic><topic>Real time</topic><topic>Sensor arrays</topic><topic>Sensors</topic><topic>Surface resistance</topic><topic>Temperature sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, Zhonghao</creatorcontrib><creatorcontrib>Zhao, Tiankai</creatorcontrib><creatorcontrib>Qu, Chunchun</creatorcontrib><creatorcontrib>Zhang, Rui</creatorcontrib><creatorcontrib>Li, Zhen</creatorcontrib><creatorcontrib>Bai, Xianxu</creatorcontrib><creatorcontrib>He, Zhizhu</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE sensors journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Wang, Zhonghao</au><au>Zhao, Tiankai</au><au>Qu, Chunchun</au><au>Zhang, Rui</au><au>Li, Zhen</au><au>Bai, Xianxu</au><au>He, Zhizhu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A High-Resolution Film-Resistance Plantar Pressure Sensor</atitle><jtitle>IEEE sensors journal</jtitle><stitle>JSEN</stitle><date>2023-12-15</date><risdate>2023</risdate><volume>23</volume><issue>24</issue><spage>30213</spage><epage>30221</epage><pages>30213-30221</pages><issn>1530-437X</issn><eissn>1558-1748</eissn><coden>ISJEAZ</coden><abstract>It is a crucial point to monitor real-time plantar pressure for application in physical condition assessment and sports injury diagnosis. In this work, we report a high-resolution (sensitive points number of 187) plantar pressure sensor (PPS) array based on the piezoresistive principle. It consists of a force-sensitive film (FSF) and a network of orthogonal conductive threads on both sides. The PPS could achieve a sensitivity of 0.124 kPa−1, a measurement range of up to 50 kPa, and excellent stability. An intelligent insole system consisting of a centimeter-level resolution PPS array, wireless Bluetooth transmitter data acquisition system, and wireless receiving terminal intelligent system is established to monitor and map the plantar pressure in real time. This intelligent insole system can identify various standing and sports positions, which is a terrific way to monitor health, avoid injuries, and train athletes.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/JSEN.2023.3329879</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0003-4477-8335</orcidid><orcidid>https://orcid.org/0000-0001-8861-9964</orcidid></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1530-437X |
ispartof | IEEE sensors journal, 2023-12, Vol.23 (24), p.30213-30221 |
issn | 1530-437X 1558-1748 |
language | eng |
recordid | cdi_proquest_journals_2902126159 |
source | IEEE Electronic Library (IEL) |
subjects | Biomedical monitoring Bluetooth Data acquisition High resolution High-resolution imaging Immune system Injury prevention Insoles intelligent insole system Monitoring piezoresistive principle Plantar pressure plantar pressure monitoring Pressure sensors Real time Sensor arrays Sensors Surface resistance Temperature sensors |
title | A High-Resolution Film-Resistance Plantar Pressure Sensor |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T11%3A34%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20High-Resolution%20Film-Resistance%20Plantar%20Pressure%20Sensor&rft.jtitle=IEEE%20sensors%20journal&rft.au=Wang,%20Zhonghao&rft.date=2023-12-15&rft.volume=23&rft.issue=24&rft.spage=30213&rft.epage=30221&rft.pages=30213-30221&rft.issn=1530-437X&rft.eissn=1558-1748&rft.coden=ISJEAZ&rft_id=info:doi/10.1109/JSEN.2023.3329879&rft_dat=%3Cproquest_RIE%3E2902126159%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2902126159&rft_id=info:pmid/&rft_ieee_id=10314442&rfr_iscdi=true |