Modeling Study of Aluminum-Based Electrocoagulation System for Wastewater Treatment

The effective treatment of wastewater generated from households, communities, and industries is vital for preserving our environment. Chemical treatment, which involves adding coagulant chemicals directly into the wastewater, is the most popular treatment method. However, due to its high operating c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of environmental engineering (New York, N.Y.) N.Y.), 2024-02, Vol.150 (2)
Hauptverfasser: Dey, Swachwa, Adejinle, Adebayo, Cho, Kyu Taek
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 2
container_start_page
container_title Journal of environmental engineering (New York, N.Y.)
container_volume 150
creator Dey, Swachwa
Adejinle, Adebayo
Cho, Kyu Taek
description The effective treatment of wastewater generated from households, communities, and industries is vital for preserving our environment. Chemical treatment, which involves adding coagulant chemicals directly into the wastewater, is the most popular treatment method. However, due to its high operating costs and the issue of secondary contamination, there is a need for an effective method to address these issues. In this study, we investigated the electrocoagulation (EC) system, which is currently undergoing a revival in research due to its promising features, such as low system and operating costs and its environmentally friendly process. We developed two-dimensional unsteady mathematical models supported by Langmuir isotherm theory to elucidate the underlying physics of the aluminum-based EC process and to understand key control parameters. The developed model was used to analyze the effects of EC cell geometry and operating conditions on the local distribution of intermediate ionic species and their impact on the adsorption behaviors of EC-generated coagulants on arsenic pollutants in the wastewater for the first time. It was found that a higher removal rate was achieved as the EC treatment time and current intensity increased, while the cell gap and inflow rate decreased. Applying the current-off condition during the EC process was found to be an efficient method for increasing the removal rate with less consumption of electrical energy.
doi_str_mv 10.1061/JOEEDU.EEENG-7443
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2894183222</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2894183222</sourcerecordid><originalsourceid>FETCH-LOGICAL-c225t-237a6351f60f5dc38cc94297dfb1f6c3d98bd4b58858bd888f4403b72a35ee973</originalsourceid><addsrcrecordid>eNotkE9PwjAAxRujiYh-AG9NPA_7b2t7RJyoQTkA8dh0XUsg24ptF8O3d4in9_Ly8l7yA-AeowlGBX58X5bl82ZSluXnPOOM0QswwpLRjAuOLsEIcUozSTm5Bjcx7hHCrJB8BFYfvrbNrtvCVerrI_QOTpu-3XV9mz3paGtYNtak4I3X277Raec7uDrGZFvofIBferA_OtkA18Hq1Nou3YIrp5to7_51DDYv5Xr2mi2W87fZdJEZQvKUEcp1QXPsCuTy2lBhjGRE8tpVQ2ZoLUVVsyoXIh-MEMIxhmjFiaa5tZLTMXg47x6C_-5tTGrv-9ANl4oIybCghJChhc8tE3yMwTp1CLtWh6PCSJ3YqTM79cdOndjRX8blY2Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2894183222</pqid></control><display><type>article</type><title>Modeling Study of Aluminum-Based Electrocoagulation System for Wastewater Treatment</title><source>American Society of Civil Engineers:NESLI2:Journals:2014</source><creator>Dey, Swachwa ; Adejinle, Adebayo ; Cho, Kyu Taek</creator><creatorcontrib>Dey, Swachwa ; Adejinle, Adebayo ; Cho, Kyu Taek</creatorcontrib><description>The effective treatment of wastewater generated from households, communities, and industries is vital for preserving our environment. Chemical treatment, which involves adding coagulant chemicals directly into the wastewater, is the most popular treatment method. However, due to its high operating costs and the issue of secondary contamination, there is a need for an effective method to address these issues. In this study, we investigated the electrocoagulation (EC) system, which is currently undergoing a revival in research due to its promising features, such as low system and operating costs and its environmentally friendly process. We developed two-dimensional unsteady mathematical models supported by Langmuir isotherm theory to elucidate the underlying physics of the aluminum-based EC process and to understand key control parameters. The developed model was used to analyze the effects of EC cell geometry and operating conditions on the local distribution of intermediate ionic species and their impact on the adsorption behaviors of EC-generated coagulants on arsenic pollutants in the wastewater for the first time. It was found that a higher removal rate was achieved as the EC treatment time and current intensity increased, while the cell gap and inflow rate decreased. Applying the current-off condition during the EC process was found to be an efficient method for increasing the removal rate with less consumption of electrical energy.</description><identifier>ISSN: 0733-9372</identifier><identifier>EISSN: 1943-7870</identifier><identifier>DOI: 10.1061/JOEEDU.EEENG-7443</identifier><language>eng</language><publisher>New York: American Society of Civil Engineers</publisher><subject>Aluminum ; Arsenic ; Chemical treatment ; Coagulants ; Contamination ; Electrocoagulation ; Geographical distribution ; Households ; Mathematical models ; Operating costs ; Wastewater treatment</subject><ispartof>Journal of environmental engineering (New York, N.Y.), 2024-02, Vol.150 (2)</ispartof><rights>2023 American Society of Civil Engineers</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c225t-237a6351f60f5dc38cc94297dfb1f6c3d98bd4b58858bd888f4403b72a35ee973</cites><orcidid>0000-0001-9883-2013</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Dey, Swachwa</creatorcontrib><creatorcontrib>Adejinle, Adebayo</creatorcontrib><creatorcontrib>Cho, Kyu Taek</creatorcontrib><title>Modeling Study of Aluminum-Based Electrocoagulation System for Wastewater Treatment</title><title>Journal of environmental engineering (New York, N.Y.)</title><description>The effective treatment of wastewater generated from households, communities, and industries is vital for preserving our environment. Chemical treatment, which involves adding coagulant chemicals directly into the wastewater, is the most popular treatment method. However, due to its high operating costs and the issue of secondary contamination, there is a need for an effective method to address these issues. In this study, we investigated the electrocoagulation (EC) system, which is currently undergoing a revival in research due to its promising features, such as low system and operating costs and its environmentally friendly process. We developed two-dimensional unsteady mathematical models supported by Langmuir isotherm theory to elucidate the underlying physics of the aluminum-based EC process and to understand key control parameters. The developed model was used to analyze the effects of EC cell geometry and operating conditions on the local distribution of intermediate ionic species and their impact on the adsorption behaviors of EC-generated coagulants on arsenic pollutants in the wastewater for the first time. It was found that a higher removal rate was achieved as the EC treatment time and current intensity increased, while the cell gap and inflow rate decreased. Applying the current-off condition during the EC process was found to be an efficient method for increasing the removal rate with less consumption of electrical energy.</description><subject>Aluminum</subject><subject>Arsenic</subject><subject>Chemical treatment</subject><subject>Coagulants</subject><subject>Contamination</subject><subject>Electrocoagulation</subject><subject>Geographical distribution</subject><subject>Households</subject><subject>Mathematical models</subject><subject>Operating costs</subject><subject>Wastewater treatment</subject><issn>0733-9372</issn><issn>1943-7870</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNotkE9PwjAAxRujiYh-AG9NPA_7b2t7RJyoQTkA8dh0XUsg24ptF8O3d4in9_Ly8l7yA-AeowlGBX58X5bl82ZSluXnPOOM0QswwpLRjAuOLsEIcUozSTm5Bjcx7hHCrJB8BFYfvrbNrtvCVerrI_QOTpu-3XV9mz3paGtYNtak4I3X277Raec7uDrGZFvofIBferA_OtkA18Hq1Nou3YIrp5to7_51DDYv5Xr2mi2W87fZdJEZQvKUEcp1QXPsCuTy2lBhjGRE8tpVQ2ZoLUVVsyoXIh-MEMIxhmjFiaa5tZLTMXg47x6C_-5tTGrv-9ANl4oIybCghJChhc8tE3yMwTp1CLtWh6PCSJ3YqTM79cdOndjRX8blY2Q</recordid><startdate>202402</startdate><enddate>202402</enddate><creator>Dey, Swachwa</creator><creator>Adejinle, Adebayo</creator><creator>Cho, Kyu Taek</creator><general>American Society of Civil Engineers</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7ST</scope><scope>7T7</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>SOI</scope><orcidid>https://orcid.org/0000-0001-9883-2013</orcidid></search><sort><creationdate>202402</creationdate><title>Modeling Study of Aluminum-Based Electrocoagulation System for Wastewater Treatment</title><author>Dey, Swachwa ; Adejinle, Adebayo ; Cho, Kyu Taek</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c225t-237a6351f60f5dc38cc94297dfb1f6c3d98bd4b58858bd888f4403b72a35ee973</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Aluminum</topic><topic>Arsenic</topic><topic>Chemical treatment</topic><topic>Coagulants</topic><topic>Contamination</topic><topic>Electrocoagulation</topic><topic>Geographical distribution</topic><topic>Households</topic><topic>Mathematical models</topic><topic>Operating costs</topic><topic>Wastewater treatment</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dey, Swachwa</creatorcontrib><creatorcontrib>Adejinle, Adebayo</creatorcontrib><creatorcontrib>Cho, Kyu Taek</creatorcontrib><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Environment Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Environment Abstracts</collection><jtitle>Journal of environmental engineering (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dey, Swachwa</au><au>Adejinle, Adebayo</au><au>Cho, Kyu Taek</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Modeling Study of Aluminum-Based Electrocoagulation System for Wastewater Treatment</atitle><jtitle>Journal of environmental engineering (New York, N.Y.)</jtitle><date>2024-02</date><risdate>2024</risdate><volume>150</volume><issue>2</issue><issn>0733-9372</issn><eissn>1943-7870</eissn><abstract>The effective treatment of wastewater generated from households, communities, and industries is vital for preserving our environment. Chemical treatment, which involves adding coagulant chemicals directly into the wastewater, is the most popular treatment method. However, due to its high operating costs and the issue of secondary contamination, there is a need for an effective method to address these issues. In this study, we investigated the electrocoagulation (EC) system, which is currently undergoing a revival in research due to its promising features, such as low system and operating costs and its environmentally friendly process. We developed two-dimensional unsteady mathematical models supported by Langmuir isotherm theory to elucidate the underlying physics of the aluminum-based EC process and to understand key control parameters. The developed model was used to analyze the effects of EC cell geometry and operating conditions on the local distribution of intermediate ionic species and their impact on the adsorption behaviors of EC-generated coagulants on arsenic pollutants in the wastewater for the first time. It was found that a higher removal rate was achieved as the EC treatment time and current intensity increased, while the cell gap and inflow rate decreased. Applying the current-off condition during the EC process was found to be an efficient method for increasing the removal rate with less consumption of electrical energy.</abstract><cop>New York</cop><pub>American Society of Civil Engineers</pub><doi>10.1061/JOEEDU.EEENG-7443</doi><orcidid>https://orcid.org/0000-0001-9883-2013</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0733-9372
ispartof Journal of environmental engineering (New York, N.Y.), 2024-02, Vol.150 (2)
issn 0733-9372
1943-7870
language eng
recordid cdi_proquest_journals_2894183222
source American Society of Civil Engineers:NESLI2:Journals:2014
subjects Aluminum
Arsenic
Chemical treatment
Coagulants
Contamination
Electrocoagulation
Geographical distribution
Households
Mathematical models
Operating costs
Wastewater treatment
title Modeling Study of Aluminum-Based Electrocoagulation System for Wastewater Treatment
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T20%3A47%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Modeling%20Study%20of%20Aluminum-Based%20Electrocoagulation%20System%20for%20Wastewater%20Treatment&rft.jtitle=Journal%20of%20environmental%20engineering%20(New%20York,%20N.Y.)&rft.au=Dey,%20Swachwa&rft.date=2024-02&rft.volume=150&rft.issue=2&rft.issn=0733-9372&rft.eissn=1943-7870&rft_id=info:doi/10.1061/JOEEDU.EEENG-7443&rft_dat=%3Cproquest_cross%3E2894183222%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2894183222&rft_id=info:pmid/&rfr_iscdi=true