High-precision interferometric measurement of slow and fast temperature changes in static fluid and convective flow

We explore the strengths and limitations of using a standard Michelson interferometer to sample line-of-sight-averaged temperature in water via two experimental setups: slow-varying temperature in static fluid and fast temperature variations in convective flow. The high precision of our measurements...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Experiments in fluids 2023-11, Vol.64 (11), Article 178
Hauptverfasser: Ge, Xinyang, Zielińska, Joanna A., Maldonado, Sergio
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 11
container_start_page
container_title Experiments in fluids
container_volume 64
creator Ge, Xinyang
Zielińska, Joanna A.
Maldonado, Sergio
description We explore the strengths and limitations of using a standard Michelson interferometer to sample line-of-sight-averaged temperature in water via two experimental setups: slow-varying temperature in static fluid and fast temperature variations in convective flow. The high precision of our measurements (a few mK) is enabled by the fast response time and high sensitivity of the interferometer to minute changes in the refractive index of water caused by temperature variations. These features allow us to detect the signature of fine fluid dynamical patterns in convective flow in a fully non-intrusive manner. For example, we are able to observe an asymmetry in the rising thermal plume (i.e., an asynchronous arrival of two counter-rotating vortices at the measurement location), which is not possible to resolve with more traditional (and invasive) techniques, such as RTD (Resistance Temperature Detector) sensors. These findings, and the overall reliability of our method, are further corroborated by means of Particle Image Velocimetry and Large Eddy Simulations. While this method presents inherent limitations (mainly stemming from the line-of-sight-averaged nature of its results), its non-intrusiveness and robustness, along with the ability to readily yield real-time, highly accurate measurements, render this technique very attractive for a wide range of applications in experimental fluid dynamics.
doi_str_mv 10.1007/s00348-023-03720-w
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2883316147</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2883316147</sourcerecordid><originalsourceid>FETCH-LOGICAL-c229w-69533450d37f21fb2b39f114323879629d6b72c70a0d6eaf830b7feea1cafe53</originalsourceid><addsrcrecordid>eNp9kMFOwzAQRC0EEqXwA5wscQ6s7SROjqgCilSJS--W46zbVE0cbLcRf49pkbhxWmn3zaxmCLln8MgA5FMAEHmVARcZCMkhmy7IjOWCZ4yx_JLMQKZTXpX5NbkJYQfAihqqGQnLbrPNRo-mC50baDdE9Ba96zH6ztAedTh47HGI1Fka9m6iemip1SHSiP2IXscEULPVwwZDMqAh6pikdn_o2hNs3HBEE7sjpqWbbsmV1fuAd79zTtavL-vFMlt9vL0vnleZ4byesrIuhMgLaIW0nNmGN6K27CeUqGRd8rotG8mNBA1tidpWAhppETUz2mIh5uThbDt693nAENXOHfyQPipeVUKwkuUyUfxMGe9C8GjV6Lte-y_FQP10q87dqtStOnWrpiQSZ1FIcIrt_6z_UX0DO-5_HA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2883316147</pqid></control><display><type>article</type><title>High-precision interferometric measurement of slow and fast temperature changes in static fluid and convective flow</title><source>SpringerLink Journals - AutoHoldings</source><creator>Ge, Xinyang ; Zielińska, Joanna A. ; Maldonado, Sergio</creator><creatorcontrib>Ge, Xinyang ; Zielińska, Joanna A. ; Maldonado, Sergio</creatorcontrib><description>We explore the strengths and limitations of using a standard Michelson interferometer to sample line-of-sight-averaged temperature in water via two experimental setups: slow-varying temperature in static fluid and fast temperature variations in convective flow. The high precision of our measurements (a few mK) is enabled by the fast response time and high sensitivity of the interferometer to minute changes in the refractive index of water caused by temperature variations. These features allow us to detect the signature of fine fluid dynamical patterns in convective flow in a fully non-intrusive manner. For example, we are able to observe an asymmetry in the rising thermal plume (i.e., an asynchronous arrival of two counter-rotating vortices at the measurement location), which is not possible to resolve with more traditional (and invasive) techniques, such as RTD (Resistance Temperature Detector) sensors. These findings, and the overall reliability of our method, are further corroborated by means of Particle Image Velocimetry and Large Eddy Simulations. While this method presents inherent limitations (mainly stemming from the line-of-sight-averaged nature of its results), its non-intrusiveness and robustness, along with the ability to readily yield real-time, highly accurate measurements, render this technique very attractive for a wide range of applications in experimental fluid dynamics.</description><identifier>ISSN: 0723-4864</identifier><identifier>EISSN: 1432-1114</identifier><identifier>DOI: 10.1007/s00348-023-03720-w</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer Berlin Heidelberg</publisher><subject>Convective flow ; Engineering ; Engineering Fluid Dynamics ; Engineering Thermodynamics ; Fluid dynamics ; Fluid flow ; Fluid- and Aerodynamics ; Heat and Mass Transfer ; Large eddy simulation ; Line of sight ; Michelson interferometers ; Particle image velocimetry ; Refractivity ; Research Article ; Temperature effects ; Time measurement</subject><ispartof>Experiments in fluids, 2023-11, Vol.64 (11), Article 178</ispartof><rights>The Author(s) 2023</rights><rights>The Author(s) 2023. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c229w-69533450d37f21fb2b39f114323879629d6b72c70a0d6eaf830b7feea1cafe53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00348-023-03720-w$$EPDF$$P50$$Gspringer$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00348-023-03720-w$$EHTML$$P50$$Gspringer$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids></links><search><creatorcontrib>Ge, Xinyang</creatorcontrib><creatorcontrib>Zielińska, Joanna A.</creatorcontrib><creatorcontrib>Maldonado, Sergio</creatorcontrib><title>High-precision interferometric measurement of slow and fast temperature changes in static fluid and convective flow</title><title>Experiments in fluids</title><addtitle>Exp Fluids</addtitle><description>We explore the strengths and limitations of using a standard Michelson interferometer to sample line-of-sight-averaged temperature in water via two experimental setups: slow-varying temperature in static fluid and fast temperature variations in convective flow. The high precision of our measurements (a few mK) is enabled by the fast response time and high sensitivity of the interferometer to minute changes in the refractive index of water caused by temperature variations. These features allow us to detect the signature of fine fluid dynamical patterns in convective flow in a fully non-intrusive manner. For example, we are able to observe an asymmetry in the rising thermal plume (i.e., an asynchronous arrival of two counter-rotating vortices at the measurement location), which is not possible to resolve with more traditional (and invasive) techniques, such as RTD (Resistance Temperature Detector) sensors. These findings, and the overall reliability of our method, are further corroborated by means of Particle Image Velocimetry and Large Eddy Simulations. While this method presents inherent limitations (mainly stemming from the line-of-sight-averaged nature of its results), its non-intrusiveness and robustness, along with the ability to readily yield real-time, highly accurate measurements, render this technique very attractive for a wide range of applications in experimental fluid dynamics.</description><subject>Convective flow</subject><subject>Engineering</subject><subject>Engineering Fluid Dynamics</subject><subject>Engineering Thermodynamics</subject><subject>Fluid dynamics</subject><subject>Fluid flow</subject><subject>Fluid- and Aerodynamics</subject><subject>Heat and Mass Transfer</subject><subject>Large eddy simulation</subject><subject>Line of sight</subject><subject>Michelson interferometers</subject><subject>Particle image velocimetry</subject><subject>Refractivity</subject><subject>Research Article</subject><subject>Temperature effects</subject><subject>Time measurement</subject><issn>0723-4864</issn><issn>1432-1114</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>C6C</sourceid><recordid>eNp9kMFOwzAQRC0EEqXwA5wscQ6s7SROjqgCilSJS--W46zbVE0cbLcRf49pkbhxWmn3zaxmCLln8MgA5FMAEHmVARcZCMkhmy7IjOWCZ4yx_JLMQKZTXpX5NbkJYQfAihqqGQnLbrPNRo-mC50baDdE9Ba96zH6ztAedTh47HGI1Fka9m6iemip1SHSiP2IXscEULPVwwZDMqAh6pikdn_o2hNs3HBEE7sjpqWbbsmV1fuAd79zTtavL-vFMlt9vL0vnleZ4byesrIuhMgLaIW0nNmGN6K27CeUqGRd8rotG8mNBA1tidpWAhppETUz2mIh5uThbDt693nAENXOHfyQPipeVUKwkuUyUfxMGe9C8GjV6Lte-y_FQP10q87dqtStOnWrpiQSZ1FIcIrt_6z_UX0DO-5_HA</recordid><startdate>20231101</startdate><enddate>20231101</enddate><creator>Ge, Xinyang</creator><creator>Zielińska, Joanna A.</creator><creator>Maldonado, Sergio</creator><general>Springer Berlin Heidelberg</general><general>Springer Nature B.V</general><scope>C6C</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20231101</creationdate><title>High-precision interferometric measurement of slow and fast temperature changes in static fluid and convective flow</title><author>Ge, Xinyang ; Zielińska, Joanna A. ; Maldonado, Sergio</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c229w-69533450d37f21fb2b39f114323879629d6b72c70a0d6eaf830b7feea1cafe53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Convective flow</topic><topic>Engineering</topic><topic>Engineering Fluid Dynamics</topic><topic>Engineering Thermodynamics</topic><topic>Fluid dynamics</topic><topic>Fluid flow</topic><topic>Fluid- and Aerodynamics</topic><topic>Heat and Mass Transfer</topic><topic>Large eddy simulation</topic><topic>Line of sight</topic><topic>Michelson interferometers</topic><topic>Particle image velocimetry</topic><topic>Refractivity</topic><topic>Research Article</topic><topic>Temperature effects</topic><topic>Time measurement</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ge, Xinyang</creatorcontrib><creatorcontrib>Zielińska, Joanna A.</creatorcontrib><creatorcontrib>Maldonado, Sergio</creatorcontrib><collection>Springer Nature OA Free Journals</collection><collection>CrossRef</collection><jtitle>Experiments in fluids</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ge, Xinyang</au><au>Zielińska, Joanna A.</au><au>Maldonado, Sergio</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High-precision interferometric measurement of slow and fast temperature changes in static fluid and convective flow</atitle><jtitle>Experiments in fluids</jtitle><stitle>Exp Fluids</stitle><date>2023-11-01</date><risdate>2023</risdate><volume>64</volume><issue>11</issue><artnum>178</artnum><issn>0723-4864</issn><eissn>1432-1114</eissn><abstract>We explore the strengths and limitations of using a standard Michelson interferometer to sample line-of-sight-averaged temperature in water via two experimental setups: slow-varying temperature in static fluid and fast temperature variations in convective flow. The high precision of our measurements (a few mK) is enabled by the fast response time and high sensitivity of the interferometer to minute changes in the refractive index of water caused by temperature variations. These features allow us to detect the signature of fine fluid dynamical patterns in convective flow in a fully non-intrusive manner. For example, we are able to observe an asymmetry in the rising thermal plume (i.e., an asynchronous arrival of two counter-rotating vortices at the measurement location), which is not possible to resolve with more traditional (and invasive) techniques, such as RTD (Resistance Temperature Detector) sensors. These findings, and the overall reliability of our method, are further corroborated by means of Particle Image Velocimetry and Large Eddy Simulations. While this method presents inherent limitations (mainly stemming from the line-of-sight-averaged nature of its results), its non-intrusiveness and robustness, along with the ability to readily yield real-time, highly accurate measurements, render this technique very attractive for a wide range of applications in experimental fluid dynamics.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><doi>10.1007/s00348-023-03720-w</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0723-4864
ispartof Experiments in fluids, 2023-11, Vol.64 (11), Article 178
issn 0723-4864
1432-1114
language eng
recordid cdi_proquest_journals_2883316147
source SpringerLink Journals - AutoHoldings
subjects Convective flow
Engineering
Engineering Fluid Dynamics
Engineering Thermodynamics
Fluid dynamics
Fluid flow
Fluid- and Aerodynamics
Heat and Mass Transfer
Large eddy simulation
Line of sight
Michelson interferometers
Particle image velocimetry
Refractivity
Research Article
Temperature effects
Time measurement
title High-precision interferometric measurement of slow and fast temperature changes in static fluid and convective flow
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T00%3A56%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High-precision%20interferometric%20measurement%20of%20slow%20and%20fast%20temperature%20changes%20in%20static%20fluid%20and%20convective%20flow&rft.jtitle=Experiments%20in%20fluids&rft.au=Ge,%20Xinyang&rft.date=2023-11-01&rft.volume=64&rft.issue=11&rft.artnum=178&rft.issn=0723-4864&rft.eissn=1432-1114&rft_id=info:doi/10.1007/s00348-023-03720-w&rft_dat=%3Cproquest_cross%3E2883316147%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2883316147&rft_id=info:pmid/&rfr_iscdi=true