Biot–Savart-Based Design and Workbench Validation at 100 MHz of Transverse Field Surface RF Coils

Radiofrequency (RF) surface coils are extensively used as receivers in magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) systems thanks to their high signal-to-noise ratio (SNR). For specific magnetic resonance applications, the design of dedicated RF surface coils with a tr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electronics (Basel) 2023-06, Vol.12 (12), p.2578
Hauptverfasser: Giovannetti, Giulio, Alecci, Marcello, Galante, Angelo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 12
container_start_page 2578
container_title Electronics (Basel)
container_volume 12
creator Giovannetti, Giulio
Alecci, Marcello
Galante, Angelo
description Radiofrequency (RF) surface coils are extensively used as receivers in magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) systems thanks to their high signal-to-noise ratio (SNR). For specific magnetic resonance applications, the design of dedicated RF surface coils with a transverse (to the coil’s plane) RF magnetic field pattern can be necessary. Such transverse-field RF coils are constituted by several central linear (parallel or crossing) conductor elements connected by return current paths. Typically, the outer shape of such RF coils is circular or squared, although other geometries can be used. This paper describes the implementation and validation of a transverse-field RF surface coil simulator based on magnetostatic analysis, which permits the design and optimization of square butterfly and figure-of-eight RF coils with adjustable size and mutual distance between the central linear current elements. The simulation results, compared with the ones provided by a standard square loop RF coil, were validated with 100 MHz workbench measurements performed on three home-built prototypes. Finally, two novel quadrature RF coil structures designed by overlapping two orthogonal square butterfly and figure-of-eight RF coils were simulated and theoretically characterized. The RF coils described here should be suitable for a wide range of MRI/MRS preclinical/clinical applications, mainly at fields below 3 T.
doi_str_mv 10.3390/electronics12122578
format Article
fullrecord <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_journals_2829796512</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A757752970</galeid><sourcerecordid>A757752970</sourcerecordid><originalsourceid>FETCH-LOGICAL-c389t-77b5312b4be1a33dee2e65abaec4be99cd5af9695f0d338db2bbb9cbca4c17403</originalsourceid><addsrcrecordid>eNptUU1LAzEQXURBqf4CLwHPW_PRNJujrdYKiuDncZkks5q63dRkW9CT_8F_6C9xRUGFzhxmePPem8PLsn1G-0Joeog12jaGxtvEOONcqmIj2-FU6VxzzTf_7NvZXkoz2pVmohB0J7MjH9qPt_drWEFs8xEkdOQYk39oCDSO3If4ZLCxj-QOau-g9aE7tIRRSi6mryRU5CZCk1YYE5KJx9qR62WswCK5mpBx8HXazbYqqBPu_cxedjs5uRlP8_PL07Px0XluRaHbXCkjBeNmYJCBEA6R41CCAbQdpLV1Eio91LKiTojCGW6M0dZYGFimBlT0soNv30UMz0tMbTkLy9h0L0tecK30UDL-y3qAGkvfVKGNYOc-2fJISaVkx_zy6q9hde1w7m1osPId_k8gvgU2hpQiVuUi-jnEl5LR8iunck1O4hOj8oiB</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2829796512</pqid></control><display><type>article</type><title>Biot–Savart-Based Design and Workbench Validation at 100 MHz of Transverse Field Surface RF Coils</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>MDPI - Multidisciplinary Digital Publishing Institute</source><creator>Giovannetti, Giulio ; Alecci, Marcello ; Galante, Angelo</creator><creatorcontrib>Giovannetti, Giulio ; Alecci, Marcello ; Galante, Angelo</creatorcontrib><description>Radiofrequency (RF) surface coils are extensively used as receivers in magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) systems thanks to their high signal-to-noise ratio (SNR). For specific magnetic resonance applications, the design of dedicated RF surface coils with a transverse (to the coil’s plane) RF magnetic field pattern can be necessary. Such transverse-field RF coils are constituted by several central linear (parallel or crossing) conductor elements connected by return current paths. Typically, the outer shape of such RF coils is circular or squared, although other geometries can be used. This paper describes the implementation and validation of a transverse-field RF surface coil simulator based on magnetostatic analysis, which permits the design and optimization of square butterfly and figure-of-eight RF coils with adjustable size and mutual distance between the central linear current elements. The simulation results, compared with the ones provided by a standard square loop RF coil, were validated with 100 MHz workbench measurements performed on three home-built prototypes. Finally, two novel quadrature RF coil structures designed by overlapping two orthogonal square butterfly and figure-of-eight RF coils were simulated and theoretically characterized. The RF coils described here should be suitable for a wide range of MRI/MRS preclinical/clinical applications, mainly at fields below 3 T.</description><identifier>ISSN: 2079-9292</identifier><identifier>EISSN: 2079-9292</identifier><identifier>DOI: 10.3390/electronics12122578</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Design ; Design and construction ; Design optimization ; Electric coils ; Magnetic fields ; Magnetic resonance imaging ; Magnetic resonance spectroscopy ; Medical imaging equipment ; Nuclear magnetic resonance spectroscopy ; Quadratures ; Radio frequency ; Signal to noise ratio ; Simulation ; Spectrum analysis ; Workbenches</subject><ispartof>Electronics (Basel), 2023-06, Vol.12 (12), p.2578</ispartof><rights>COPYRIGHT 2023 MDPI AG</rights><rights>2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c389t-77b5312b4be1a33dee2e65abaec4be99cd5af9695f0d338db2bbb9cbca4c17403</citedby><cites>FETCH-LOGICAL-c389t-77b5312b4be1a33dee2e65abaec4be99cd5af9695f0d338db2bbb9cbca4c17403</cites><orcidid>0000-0002-4317-4161 ; 0000-0002-3228-7785 ; 0000-0002-3958-992X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,27911,27912</link.rule.ids></links><search><creatorcontrib>Giovannetti, Giulio</creatorcontrib><creatorcontrib>Alecci, Marcello</creatorcontrib><creatorcontrib>Galante, Angelo</creatorcontrib><title>Biot–Savart-Based Design and Workbench Validation at 100 MHz of Transverse Field Surface RF Coils</title><title>Electronics (Basel)</title><description>Radiofrequency (RF) surface coils are extensively used as receivers in magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) systems thanks to their high signal-to-noise ratio (SNR). For specific magnetic resonance applications, the design of dedicated RF surface coils with a transverse (to the coil’s plane) RF magnetic field pattern can be necessary. Such transverse-field RF coils are constituted by several central linear (parallel or crossing) conductor elements connected by return current paths. Typically, the outer shape of such RF coils is circular or squared, although other geometries can be used. This paper describes the implementation and validation of a transverse-field RF surface coil simulator based on magnetostatic analysis, which permits the design and optimization of square butterfly and figure-of-eight RF coils with adjustable size and mutual distance between the central linear current elements. The simulation results, compared with the ones provided by a standard square loop RF coil, were validated with 100 MHz workbench measurements performed on three home-built prototypes. Finally, two novel quadrature RF coil structures designed by overlapping two orthogonal square butterfly and figure-of-eight RF coils were simulated and theoretically characterized. The RF coils described here should be suitable for a wide range of MRI/MRS preclinical/clinical applications, mainly at fields below 3 T.</description><subject>Design</subject><subject>Design and construction</subject><subject>Design optimization</subject><subject>Electric coils</subject><subject>Magnetic fields</subject><subject>Magnetic resonance imaging</subject><subject>Magnetic resonance spectroscopy</subject><subject>Medical imaging equipment</subject><subject>Nuclear magnetic resonance spectroscopy</subject><subject>Quadratures</subject><subject>Radio frequency</subject><subject>Signal to noise ratio</subject><subject>Simulation</subject><subject>Spectrum analysis</subject><subject>Workbenches</subject><issn>2079-9292</issn><issn>2079-9292</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNptUU1LAzEQXURBqf4CLwHPW_PRNJujrdYKiuDncZkks5q63dRkW9CT_8F_6C9xRUGFzhxmePPem8PLsn1G-0Joeog12jaGxtvEOONcqmIj2-FU6VxzzTf_7NvZXkoz2pVmohB0J7MjH9qPt_drWEFs8xEkdOQYk39oCDSO3If4ZLCxj-QOau-g9aE7tIRRSi6mryRU5CZCk1YYE5KJx9qR62WswCK5mpBx8HXazbYqqBPu_cxedjs5uRlP8_PL07Px0XluRaHbXCkjBeNmYJCBEA6R41CCAbQdpLV1Eio91LKiTojCGW6M0dZYGFimBlT0soNv30UMz0tMbTkLy9h0L0tecK30UDL-y3qAGkvfVKGNYOc-2fJISaVkx_zy6q9hde1w7m1osPId_k8gvgU2hpQiVuUi-jnEl5LR8iunck1O4hOj8oiB</recordid><startdate>20230601</startdate><enddate>20230601</enddate><creator>Giovannetti, Giulio</creator><creator>Alecci, Marcello</creator><creator>Galante, Angelo</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L7M</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><orcidid>https://orcid.org/0000-0002-4317-4161</orcidid><orcidid>https://orcid.org/0000-0002-3228-7785</orcidid><orcidid>https://orcid.org/0000-0002-3958-992X</orcidid></search><sort><creationdate>20230601</creationdate><title>Biot–Savart-Based Design and Workbench Validation at 100 MHz of Transverse Field Surface RF Coils</title><author>Giovannetti, Giulio ; Alecci, Marcello ; Galante, Angelo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c389t-77b5312b4be1a33dee2e65abaec4be99cd5af9695f0d338db2bbb9cbca4c17403</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Design</topic><topic>Design and construction</topic><topic>Design optimization</topic><topic>Electric coils</topic><topic>Magnetic fields</topic><topic>Magnetic resonance imaging</topic><topic>Magnetic resonance spectroscopy</topic><topic>Medical imaging equipment</topic><topic>Nuclear magnetic resonance spectroscopy</topic><topic>Quadratures</topic><topic>Radio frequency</topic><topic>Signal to noise ratio</topic><topic>Simulation</topic><topic>Spectrum analysis</topic><topic>Workbenches</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Giovannetti, Giulio</creatorcontrib><creatorcontrib>Alecci, Marcello</creatorcontrib><creatorcontrib>Galante, Angelo</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Advanced Technologies &amp; Aerospace Database</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><jtitle>Electronics (Basel)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Giovannetti, Giulio</au><au>Alecci, Marcello</au><au>Galante, Angelo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Biot–Savart-Based Design and Workbench Validation at 100 MHz of Transverse Field Surface RF Coils</atitle><jtitle>Electronics (Basel)</jtitle><date>2023-06-01</date><risdate>2023</risdate><volume>12</volume><issue>12</issue><spage>2578</spage><pages>2578-</pages><issn>2079-9292</issn><eissn>2079-9292</eissn><abstract>Radiofrequency (RF) surface coils are extensively used as receivers in magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) systems thanks to their high signal-to-noise ratio (SNR). For specific magnetic resonance applications, the design of dedicated RF surface coils with a transverse (to the coil’s plane) RF magnetic field pattern can be necessary. Such transverse-field RF coils are constituted by several central linear (parallel or crossing) conductor elements connected by return current paths. Typically, the outer shape of such RF coils is circular or squared, although other geometries can be used. This paper describes the implementation and validation of a transverse-field RF surface coil simulator based on magnetostatic analysis, which permits the design and optimization of square butterfly and figure-of-eight RF coils with adjustable size and mutual distance between the central linear current elements. The simulation results, compared with the ones provided by a standard square loop RF coil, were validated with 100 MHz workbench measurements performed on three home-built prototypes. Finally, two novel quadrature RF coil structures designed by overlapping two orthogonal square butterfly and figure-of-eight RF coils were simulated and theoretically characterized. The RF coils described here should be suitable for a wide range of MRI/MRS preclinical/clinical applications, mainly at fields below 3 T.</abstract><cop>Basel</cop><pub>MDPI AG</pub><doi>10.3390/electronics12122578</doi><orcidid>https://orcid.org/0000-0002-4317-4161</orcidid><orcidid>https://orcid.org/0000-0002-3228-7785</orcidid><orcidid>https://orcid.org/0000-0002-3958-992X</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2079-9292
ispartof Electronics (Basel), 2023-06, Vol.12 (12), p.2578
issn 2079-9292
2079-9292
language eng
recordid cdi_proquest_journals_2829796512
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; MDPI - Multidisciplinary Digital Publishing Institute
subjects Design
Design and construction
Design optimization
Electric coils
Magnetic fields
Magnetic resonance imaging
Magnetic resonance spectroscopy
Medical imaging equipment
Nuclear magnetic resonance spectroscopy
Quadratures
Radio frequency
Signal to noise ratio
Simulation
Spectrum analysis
Workbenches
title Biot–Savart-Based Design and Workbench Validation at 100 MHz of Transverse Field Surface RF Coils
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T20%3A53%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Biot%E2%80%93Savart-Based%20Design%20and%20Workbench%20Validation%20at%20100%20MHz%20of%20Transverse%20Field%20Surface%20RF%20Coils&rft.jtitle=Electronics%20(Basel)&rft.au=Giovannetti,%20Giulio&rft.date=2023-06-01&rft.volume=12&rft.issue=12&rft.spage=2578&rft.pages=2578-&rft.issn=2079-9292&rft.eissn=2079-9292&rft_id=info:doi/10.3390/electronics12122578&rft_dat=%3Cgale_proqu%3EA757752970%3C/gale_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2829796512&rft_id=info:pmid/&rft_galeid=A757752970&rfr_iscdi=true