Computer Simulation of Measurements of VVER-1200 Emergency Protection Efficacy

The ratio of the reactivity calculated from the solution of a conditionally critical problem for the neutron flux density and the reactivity obtained using the measured values of the ionization-chamber currents. The efficacy of the emergency protection was measured at reactor startup of the Nos. 6 a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Atomic energy (New York, N.Y.) N.Y.), 2022-09, Vol.132 (5), p.263-271
Hauptverfasser: Kulikov, V. I., Zhylmaganbetov, N. M., Kavun, O. Yu, Popykin, A. I., Smirnova, A. A., Starova, N. A., Shevchenko, R. A., Shevchenko, S. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The ratio of the reactivity calculated from the solution of a conditionally critical problem for the neutron flux density and the reactivity obtained using the measured values of the ionization-chamber currents. The efficacy of the emergency protection was measured at reactor startup of the Nos. 6 and 7 power units of the Novovoronezh NPP and No 5 unit of the Leningrad NPP. The ionization chambers are situated in the biological-protection concrete. The measured and calculated values of the efficiency of the emergency protection are compared using the results of design modeling based on calculations of the ionization-chamber currents. The measured values of the quantities are compared with the calculated values.
ISSN:1063-4258
1573-8205
DOI:10.1007/s10512-023-00939-y