Computer Simulation of Measurements of VVER-1200 Emergency Protection Efficacy
The ratio of the reactivity calculated from the solution of a conditionally critical problem for the neutron flux density and the reactivity obtained using the measured values of the ionization-chamber currents. The efficacy of the emergency protection was measured at reactor startup of the Nos. 6 a...
Gespeichert in:
Veröffentlicht in: | Atomic energy (New York, N.Y.) N.Y.), 2022-09, Vol.132 (5), p.263-271 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The ratio of the reactivity calculated from the solution of a conditionally critical problem for the neutron flux density and the reactivity obtained using the measured values of the ionization-chamber currents. The efficacy of the emergency protection was measured at reactor startup of the Nos. 6 and 7 power units of the Novovoronezh NPP and No 5 unit of the Leningrad NPP. The ionization chambers are situated in the biological-protection concrete. The measured and calculated values of the efficiency of the emergency protection are compared using the results of design modeling based on calculations of the ionization-chamber currents. The measured values of the quantities are compared with the calculated values. |
---|---|
ISSN: | 1063-4258 1573-8205 |
DOI: | 10.1007/s10512-023-00939-y |