Development of Dual Ion-selective Electrodes in Double-Barrel Glass Pipette at One Micrometer for Simultaneous Measurement of Sodium and Potassium Ions

We have developed the method of preparing sodium and potassium ion-selective electrodes in double-barrel glass pipettes at the size of 1 μm. Stable and precise fabrication parameters were found for producing a double-barrel 1 μm pipette, and the produced double-barrel micropipettes were used in this...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:E-journal of surface science and nanotechnology 2022/10/27, Vol.21(1), pp.17-23
Hauptverfasser: Takami, Tomohide, Akutsu, Yusuke, Kaneko, Naoki, Yoneda, Rio, Magara, Hideyuki, Ogawa, Shuichi, Abukawa, Tadashi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 23
container_issue 1
container_start_page 17
container_title E-journal of surface science and nanotechnology
container_volume 21
creator Takami, Tomohide
Akutsu, Yusuke
Kaneko, Naoki
Yoneda, Rio
Magara, Hideyuki
Ogawa, Shuichi
Abukawa, Tadashi
description We have developed the method of preparing sodium and potassium ion-selective electrodes in double-barrel glass pipettes at the size of 1 μm. Stable and precise fabrication parameters were found for producing a double-barrel 1 μm pipette, and the produced double-barrel micropipettes were used in this study. The ionophores comprising of crown ethers of 12-crown-4 for sodium ions and 15-crown-5 for potassium ions were respectively doped in poly(vinyl chloride) films in the divided double-barrel glass pipette. The obtained selectivity coefficients and selectivity ratios are compared with the previous studies. The developed ion-selective dual-micropipettes can be applied for local ion-selective measurements such as living cells.
doi_str_mv 10.1380/ejssnt.2023-003
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2813488675</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2813488675</sourcerecordid><originalsourceid>FETCH-LOGICAL-c495t-dbdbc66209fe437c750cc5babc698425848be75278db3feef391ca73848f2e273</originalsourceid><addsrcrecordid>eNpNkFFPwjAUhRejiYg--9rE50m3but4VEAkgUCCPjddd6dbuhbbjsRf4t-1y4T40t57e8496RcE9xF-jEiOJ9BYq9xjjGMSYkwuglFEkjzEZBpd_quvgxtrGy-ghGaj4GcOR5D60IJySFdo3nGJVlqFFiQIVx8BLfrC6BIsqhWa666QED5zY0CipeTWol19AOcAcYe2CtCmFka34MCgShu0r9tOOq5AdxZtgNvOwClur8u6axFXJdpp53f1nY-3t8FVxaWFu797HLy_LN5mr-F6u1zNntahSKapC8uiLESWxXhaQUKooCkWIi24H07zJE7zJC-ApjHNy4JUAJUnIDglfl7FEFMyDh6GvQejvzqwjjW6M8pHsjjvoeUZTb1qMqj8x6w1ULGDqVtuvlmEWU-fDfRZT595uN6xGByNdfwDznpuXC0knPURi_rj5Du_i09uGCjyC_lTlTA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2813488675</pqid></control><display><type>article</type><title>Development of Dual Ion-selective Electrodes in Double-Barrel Glass Pipette at One Micrometer for Simultaneous Measurement of Sodium and Potassium Ions</title><source>J-STAGE Free</source><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Free Full-Text Journals in Chemistry</source><creator>Takami, Tomohide ; Akutsu, Yusuke ; Kaneko, Naoki ; Yoneda, Rio ; Magara, Hideyuki ; Ogawa, Shuichi ; Abukawa, Tadashi</creator><creatorcontrib>Takami, Tomohide ; Akutsu, Yusuke ; Kaneko, Naoki ; Yoneda, Rio ; Magara, Hideyuki ; Ogawa, Shuichi ; Abukawa, Tadashi</creatorcontrib><description>We have developed the method of preparing sodium and potassium ion-selective electrodes in double-barrel glass pipettes at the size of 1 μm. Stable and precise fabrication parameters were found for producing a double-barrel 1 μm pipette, and the produced double-barrel micropipettes were used in this study. The ionophores comprising of crown ethers of 12-crown-4 for sodium ions and 15-crown-5 for potassium ions were respectively doped in poly(vinyl chloride) films in the divided double-barrel glass pipette. The obtained selectivity coefficients and selectivity ratios are compared with the previous studies. The developed ion-selective dual-micropipettes can be applied for local ion-selective measurements such as living cells.</description><identifier>ISSN: 1348-0391</identifier><identifier>EISSN: 1348-0391</identifier><identifier>DOI: 10.1380/ejssnt.2023-003</identifier><language>eng</language><publisher>Tokyo: The Japan Society of Vacuum and Surface Science</publisher><subject>Crown ethers ; Double-barrel pipette ; Electrodes ; Ion-selective electrode ; Micropipette ; Potassium ; Potassium ion ; Selectivity ; Sodium ; Sodium ion ; Vinyl chloride</subject><ispartof>e-Journal of Surface Science and Nanotechnology, 2022/10/27, Vol.21(1), pp.17-23</ispartof><rights>2023 The author(s)</rights><rights>2023. This work is published under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c495t-dbdbc66209fe437c750cc5babc698425848be75278db3feef391ca73848f2e273</citedby><cites>FETCH-LOGICAL-c495t-dbdbc66209fe437c750cc5babc698425848be75278db3feef391ca73848f2e273</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,1876,27903,27904</link.rule.ids></links><search><creatorcontrib>Takami, Tomohide</creatorcontrib><creatorcontrib>Akutsu, Yusuke</creatorcontrib><creatorcontrib>Kaneko, Naoki</creatorcontrib><creatorcontrib>Yoneda, Rio</creatorcontrib><creatorcontrib>Magara, Hideyuki</creatorcontrib><creatorcontrib>Ogawa, Shuichi</creatorcontrib><creatorcontrib>Abukawa, Tadashi</creatorcontrib><title>Development of Dual Ion-selective Electrodes in Double-Barrel Glass Pipette at One Micrometer for Simultaneous Measurement of Sodium and Potassium Ions</title><title>E-journal of surface science and nanotechnology</title><addtitle>e-J. Surf. Sci. Nanotechnol.</addtitle><description>We have developed the method of preparing sodium and potassium ion-selective electrodes in double-barrel glass pipettes at the size of 1 μm. Stable and precise fabrication parameters were found for producing a double-barrel 1 μm pipette, and the produced double-barrel micropipettes were used in this study. The ionophores comprising of crown ethers of 12-crown-4 for sodium ions and 15-crown-5 for potassium ions were respectively doped in poly(vinyl chloride) films in the divided double-barrel glass pipette. The obtained selectivity coefficients and selectivity ratios are compared with the previous studies. The developed ion-selective dual-micropipettes can be applied for local ion-selective measurements such as living cells.</description><subject>Crown ethers</subject><subject>Double-barrel pipette</subject><subject>Electrodes</subject><subject>Ion-selective electrode</subject><subject>Micropipette</subject><subject>Potassium</subject><subject>Potassium ion</subject><subject>Selectivity</subject><subject>Sodium</subject><subject>Sodium ion</subject><subject>Vinyl chloride</subject><issn>1348-0391</issn><issn>1348-0391</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNpNkFFPwjAUhRejiYg--9rE50m3but4VEAkgUCCPjddd6dbuhbbjsRf4t-1y4T40t57e8496RcE9xF-jEiOJ9BYq9xjjGMSYkwuglFEkjzEZBpd_quvgxtrGy-ghGaj4GcOR5D60IJySFdo3nGJVlqFFiQIVx8BLfrC6BIsqhWa666QED5zY0CipeTWol19AOcAcYe2CtCmFka34MCgShu0r9tOOq5AdxZtgNvOwClur8u6axFXJdpp53f1nY-3t8FVxaWFu797HLy_LN5mr-F6u1zNntahSKapC8uiLESWxXhaQUKooCkWIi24H07zJE7zJC-ApjHNy4JUAJUnIDglfl7FEFMyDh6GvQejvzqwjjW6M8pHsjjvoeUZTb1qMqj8x6w1ULGDqVtuvlmEWU-fDfRZT595uN6xGByNdfwDznpuXC0knPURi_rj5Du_i09uGCjyC_lTlTA</recordid><startdate>20221027</startdate><enddate>20221027</enddate><creator>Takami, Tomohide</creator><creator>Akutsu, Yusuke</creator><creator>Kaneko, Naoki</creator><creator>Yoneda, Rio</creator><creator>Magara, Hideyuki</creator><creator>Ogawa, Shuichi</creator><creator>Abukawa, Tadashi</creator><general>The Japan Society of Vacuum and Surface Science</general><general>Japan Science and Technology Agency</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20221027</creationdate><title>Development of Dual Ion-selective Electrodes in Double-Barrel Glass Pipette at One Micrometer for Simultaneous Measurement of Sodium and Potassium Ions</title><author>Takami, Tomohide ; Akutsu, Yusuke ; Kaneko, Naoki ; Yoneda, Rio ; Magara, Hideyuki ; Ogawa, Shuichi ; Abukawa, Tadashi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c495t-dbdbc66209fe437c750cc5babc698425848be75278db3feef391ca73848f2e273</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Crown ethers</topic><topic>Double-barrel pipette</topic><topic>Electrodes</topic><topic>Ion-selective electrode</topic><topic>Micropipette</topic><topic>Potassium</topic><topic>Potassium ion</topic><topic>Selectivity</topic><topic>Sodium</topic><topic>Sodium ion</topic><topic>Vinyl chloride</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Takami, Tomohide</creatorcontrib><creatorcontrib>Akutsu, Yusuke</creatorcontrib><creatorcontrib>Kaneko, Naoki</creatorcontrib><creatorcontrib>Yoneda, Rio</creatorcontrib><creatorcontrib>Magara, Hideyuki</creatorcontrib><creatorcontrib>Ogawa, Shuichi</creatorcontrib><creatorcontrib>Abukawa, Tadashi</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>E-journal of surface science and nanotechnology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Takami, Tomohide</au><au>Akutsu, Yusuke</au><au>Kaneko, Naoki</au><au>Yoneda, Rio</au><au>Magara, Hideyuki</au><au>Ogawa, Shuichi</au><au>Abukawa, Tadashi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of Dual Ion-selective Electrodes in Double-Barrel Glass Pipette at One Micrometer for Simultaneous Measurement of Sodium and Potassium Ions</atitle><jtitle>E-journal of surface science and nanotechnology</jtitle><addtitle>e-J. Surf. Sci. Nanotechnol.</addtitle><date>2022-10-27</date><risdate>2022</risdate><volume>21</volume><issue>1</issue><spage>17</spage><epage>23</epage><pages>17-23</pages><artnum>2023-003</artnum><issn>1348-0391</issn><eissn>1348-0391</eissn><abstract>We have developed the method of preparing sodium and potassium ion-selective electrodes in double-barrel glass pipettes at the size of 1 μm. Stable and precise fabrication parameters were found for producing a double-barrel 1 μm pipette, and the produced double-barrel micropipettes were used in this study. The ionophores comprising of crown ethers of 12-crown-4 for sodium ions and 15-crown-5 for potassium ions were respectively doped in poly(vinyl chloride) films in the divided double-barrel glass pipette. The obtained selectivity coefficients and selectivity ratios are compared with the previous studies. The developed ion-selective dual-micropipettes can be applied for local ion-selective measurements such as living cells.</abstract><cop>Tokyo</cop><pub>The Japan Society of Vacuum and Surface Science</pub><doi>10.1380/ejssnt.2023-003</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1348-0391
ispartof e-Journal of Surface Science and Nanotechnology, 2022/10/27, Vol.21(1), pp.17-23
issn 1348-0391
1348-0391
language eng
recordid cdi_proquest_journals_2813488675
source J-STAGE Free; DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Free Full-Text Journals in Chemistry
subjects Crown ethers
Double-barrel pipette
Electrodes
Ion-selective electrode
Micropipette
Potassium
Potassium ion
Selectivity
Sodium
Sodium ion
Vinyl chloride
title Development of Dual Ion-selective Electrodes in Double-Barrel Glass Pipette at One Micrometer for Simultaneous Measurement of Sodium and Potassium Ions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T18%3A07%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20Dual%20Ion-selective%20Electrodes%20in%20Double-Barrel%20Glass%20Pipette%20at%20One%20Micrometer%20for%20Simultaneous%20Measurement%20of%20Sodium%20and%20Potassium%20Ions&rft.jtitle=E-journal%20of%20surface%20science%20and%20nanotechnology&rft.au=Takami,%20Tomohide&rft.date=2022-10-27&rft.volume=21&rft.issue=1&rft.spage=17&rft.epage=23&rft.pages=17-23&rft.artnum=2023-003&rft.issn=1348-0391&rft.eissn=1348-0391&rft_id=info:doi/10.1380/ejssnt.2023-003&rft_dat=%3Cproquest_cross%3E2813488675%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2813488675&rft_id=info:pmid/&rfr_iscdi=true