High Performance and Reusable SAW Sensor Coated with Thiourea-Decorated POSS with Different Functional Groups for DMMP Detection
A colorless, odorless G nerve agent, a type of chemical transfer agent (CWA) that causes significant loss of life, is being studied for quick and accurate detection. In this study, detection materials with different functional groups were synthesized based on thiourea (TU)-decorated polyhedral oligo...
Gespeichert in:
Veröffentlicht in: | Coatings (Basel) 2023-02, Vol.13 (2), p.348 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 2 |
container_start_page | 348 |
container_title | Coatings (Basel) |
container_volume | 13 |
creator | Bae, Bong-Gyu Jang, Hee-Chan Choi, Hyeong-Seon Lee, Young-Jun Kim, Joo-Hyung |
description | A colorless, odorless G nerve agent, a type of chemical transfer agent (CWA) that causes significant loss of life, is being studied for quick and accurate detection. In this study, detection materials with different functional groups were synthesized based on thiourea (TU)-decorated polyhedral oligomeric silsesquioxane (POSS) to study the most suitable material for the detection of dimethyl methylphosphonate (DMMP), a simulant of neural agents. The sensing material was coated on a SAW sensor with a resonance frequency of 250 MHz based on ST-quartz, the DMMP exposure experiment was conducted, and the performance of the sensing material was compared through frequency shift before and after exposure. Coating materials with excellent reactivity with DMMP and appropriate coating concentration for each material were identified at a concentration of 10 ppm. Among them, POSS-TU with 3,5-bis(trifluoromethyl)phenyl as a functional group showed the largest frequency shift characteristics, and it was used in low concentration (1, 5, and 10 ppm) DMMP detection experiments to confirm linear frequency shift characteristics according to low concentration. Finally, through a selectivity experiment with other gases, it was confirmed that the amount of frequency shift in other gases except DMMP was small, making it an excellent DMMP sensing material. |
doi_str_mv | 10.3390/coatings13020348 |
format | Article |
fullrecord | <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_journals_2779540168</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A743012156</galeid><sourcerecordid>A743012156</sourcerecordid><originalsourceid>FETCH-LOGICAL-c352t-a16e8fa5029a05a19b00bb230440ecf4a6ea4063f4886c4244a7130c2542ad0f3</originalsourceid><addsrcrecordid>eNpdUUtLAzEQXkRB0d49BjyvTh77OpZWraBYbMXjMk0nbaRNarKLePOnG60HceYwwzePbx5Zds7hUsoGrrTHzrpV5BIESFUfZCcCqiYvFReHf_zjbBDjKyRpuKx5c5J9TuxqzaYUjA9bdJoYuiV7oj7iYkNsNnxhM3LRBzZKHLRk77Zbs_na-j4Q5mPSPvzg08fZbB8cW2MokOvYTe90Z73DDbsNvt9FlljY-OFhysbU0U_sLDsyuIk0-LWn2fPN9Xw0ye8fb-9Gw_tcy0J0OfKSaoMFiAahQN4sABYLIUEpIG0UloQKSmlUXZdaCaWwStfQolACl2DkaXax77sL_q2n2LWvaYU0WmxFVTWFAl7WKetyn7XCDbXWGd8F1EmXtLXaOzI24cNKSeCCF2UqgH2BDj7GQKbdBbvF8NFyaL9_0_7_jfwCjxyC1g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2779540168</pqid></control><display><type>article</type><title>High Performance and Reusable SAW Sensor Coated with Thiourea-Decorated POSS with Different Functional Groups for DMMP Detection</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>MDPI - Multidisciplinary Digital Publishing Institute</source><source>Alma/SFX Local Collection</source><creator>Bae, Bong-Gyu ; Jang, Hee-Chan ; Choi, Hyeong-Seon ; Lee, Young-Jun ; Kim, Joo-Hyung</creator><creatorcontrib>Bae, Bong-Gyu ; Jang, Hee-Chan ; Choi, Hyeong-Seon ; Lee, Young-Jun ; Kim, Joo-Hyung</creatorcontrib><description>A colorless, odorless G nerve agent, a type of chemical transfer agent (CWA) that causes significant loss of life, is being studied for quick and accurate detection. In this study, detection materials with different functional groups were synthesized based on thiourea (TU)-decorated polyhedral oligomeric silsesquioxane (POSS) to study the most suitable material for the detection of dimethyl methylphosphonate (DMMP), a simulant of neural agents. The sensing material was coated on a SAW sensor with a resonance frequency of 250 MHz based on ST-quartz, the DMMP exposure experiment was conducted, and the performance of the sensing material was compared through frequency shift before and after exposure. Coating materials with excellent reactivity with DMMP and appropriate coating concentration for each material were identified at a concentration of 10 ppm. Among them, POSS-TU with 3,5-bis(trifluoromethyl)phenyl as a functional group showed the largest frequency shift characteristics, and it was used in low concentration (1, 5, and 10 ppm) DMMP detection experiments to confirm linear frequency shift characteristics according to low concentration. Finally, through a selectivity experiment with other gases, it was confirmed that the amount of frequency shift in other gases except DMMP was small, making it an excellent DMMP sensing material.</description><identifier>ISSN: 2079-6412</identifier><identifier>EISSN: 2079-6412</identifier><identifier>DOI: 10.3390/coatings13020348</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Comparative analysis ; Electron tubes ; Experiments ; Frequency shift ; Functional groups ; Hydrogen bonds ; Nerve gas ; Polyhedral oligomeric silsesquioxane ; Propagation ; Selectivity ; Sensors ; Thioureas</subject><ispartof>Coatings (Basel), 2023-02, Vol.13 (2), p.348</ispartof><rights>COPYRIGHT 2023 MDPI AG</rights><rights>2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c352t-a16e8fa5029a05a19b00bb230440ecf4a6ea4063f4886c4244a7130c2542ad0f3</citedby><cites>FETCH-LOGICAL-c352t-a16e8fa5029a05a19b00bb230440ecf4a6ea4063f4886c4244a7130c2542ad0f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,782,786,27931,27932</link.rule.ids></links><search><creatorcontrib>Bae, Bong-Gyu</creatorcontrib><creatorcontrib>Jang, Hee-Chan</creatorcontrib><creatorcontrib>Choi, Hyeong-Seon</creatorcontrib><creatorcontrib>Lee, Young-Jun</creatorcontrib><creatorcontrib>Kim, Joo-Hyung</creatorcontrib><title>High Performance and Reusable SAW Sensor Coated with Thiourea-Decorated POSS with Different Functional Groups for DMMP Detection</title><title>Coatings (Basel)</title><description>A colorless, odorless G nerve agent, a type of chemical transfer agent (CWA) that causes significant loss of life, is being studied for quick and accurate detection. In this study, detection materials with different functional groups were synthesized based on thiourea (TU)-decorated polyhedral oligomeric silsesquioxane (POSS) to study the most suitable material for the detection of dimethyl methylphosphonate (DMMP), a simulant of neural agents. The sensing material was coated on a SAW sensor with a resonance frequency of 250 MHz based on ST-quartz, the DMMP exposure experiment was conducted, and the performance of the sensing material was compared through frequency shift before and after exposure. Coating materials with excellent reactivity with DMMP and appropriate coating concentration for each material were identified at a concentration of 10 ppm. Among them, POSS-TU with 3,5-bis(trifluoromethyl)phenyl as a functional group showed the largest frequency shift characteristics, and it was used in low concentration (1, 5, and 10 ppm) DMMP detection experiments to confirm linear frequency shift characteristics according to low concentration. Finally, through a selectivity experiment with other gases, it was confirmed that the amount of frequency shift in other gases except DMMP was small, making it an excellent DMMP sensing material.</description><subject>Comparative analysis</subject><subject>Electron tubes</subject><subject>Experiments</subject><subject>Frequency shift</subject><subject>Functional groups</subject><subject>Hydrogen bonds</subject><subject>Nerve gas</subject><subject>Polyhedral oligomeric silsesquioxane</subject><subject>Propagation</subject><subject>Selectivity</subject><subject>Sensors</subject><subject>Thioureas</subject><issn>2079-6412</issn><issn>2079-6412</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNpdUUtLAzEQXkRB0d49BjyvTh77OpZWraBYbMXjMk0nbaRNarKLePOnG60HceYwwzePbx5Zds7hUsoGrrTHzrpV5BIESFUfZCcCqiYvFReHf_zjbBDjKyRpuKx5c5J9TuxqzaYUjA9bdJoYuiV7oj7iYkNsNnxhM3LRBzZKHLRk77Zbs_na-j4Q5mPSPvzg08fZbB8cW2MokOvYTe90Z73DDbsNvt9FlljY-OFhysbU0U_sLDsyuIk0-LWn2fPN9Xw0ye8fb-9Gw_tcy0J0OfKSaoMFiAahQN4sABYLIUEpIG0UloQKSmlUXZdaCaWwStfQolACl2DkaXax77sL_q2n2LWvaYU0WmxFVTWFAl7WKetyn7XCDbXWGd8F1EmXtLXaOzI24cNKSeCCF2UqgH2BDj7GQKbdBbvF8NFyaL9_0_7_jfwCjxyC1g</recordid><startdate>20230201</startdate><enddate>20230201</enddate><creator>Bae, Bong-Gyu</creator><creator>Jang, Hee-Chan</creator><creator>Choi, Hyeong-Seon</creator><creator>Lee, Young-Jun</creator><creator>Kim, Joo-Hyung</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KB.</scope><scope>PDBOC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20230201</creationdate><title>High Performance and Reusable SAW Sensor Coated with Thiourea-Decorated POSS with Different Functional Groups for DMMP Detection</title><author>Bae, Bong-Gyu ; Jang, Hee-Chan ; Choi, Hyeong-Seon ; Lee, Young-Jun ; Kim, Joo-Hyung</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c352t-a16e8fa5029a05a19b00bb230440ecf4a6ea4063f4886c4244a7130c2542ad0f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Comparative analysis</topic><topic>Electron tubes</topic><topic>Experiments</topic><topic>Frequency shift</topic><topic>Functional groups</topic><topic>Hydrogen bonds</topic><topic>Nerve gas</topic><topic>Polyhedral oligomeric silsesquioxane</topic><topic>Propagation</topic><topic>Selectivity</topic><topic>Sensors</topic><topic>Thioureas</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bae, Bong-Gyu</creatorcontrib><creatorcontrib>Jang, Hee-Chan</creatorcontrib><creatorcontrib>Choi, Hyeong-Seon</creatorcontrib><creatorcontrib>Lee, Young-Jun</creatorcontrib><creatorcontrib>Kim, Joo-Hyung</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Materials Science Database</collection><collection>Materials Science Collection</collection><collection>Access via ProQuest (Open Access)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Coatings (Basel)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bae, Bong-Gyu</au><au>Jang, Hee-Chan</au><au>Choi, Hyeong-Seon</au><au>Lee, Young-Jun</au><au>Kim, Joo-Hyung</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High Performance and Reusable SAW Sensor Coated with Thiourea-Decorated POSS with Different Functional Groups for DMMP Detection</atitle><jtitle>Coatings (Basel)</jtitle><date>2023-02-01</date><risdate>2023</risdate><volume>13</volume><issue>2</issue><spage>348</spage><pages>348-</pages><issn>2079-6412</issn><eissn>2079-6412</eissn><abstract>A colorless, odorless G nerve agent, a type of chemical transfer agent (CWA) that causes significant loss of life, is being studied for quick and accurate detection. In this study, detection materials with different functional groups were synthesized based on thiourea (TU)-decorated polyhedral oligomeric silsesquioxane (POSS) to study the most suitable material for the detection of dimethyl methylphosphonate (DMMP), a simulant of neural agents. The sensing material was coated on a SAW sensor with a resonance frequency of 250 MHz based on ST-quartz, the DMMP exposure experiment was conducted, and the performance of the sensing material was compared through frequency shift before and after exposure. Coating materials with excellent reactivity with DMMP and appropriate coating concentration for each material were identified at a concentration of 10 ppm. Among them, POSS-TU with 3,5-bis(trifluoromethyl)phenyl as a functional group showed the largest frequency shift characteristics, and it was used in low concentration (1, 5, and 10 ppm) DMMP detection experiments to confirm linear frequency shift characteristics according to low concentration. Finally, through a selectivity experiment with other gases, it was confirmed that the amount of frequency shift in other gases except DMMP was small, making it an excellent DMMP sensing material.</abstract><cop>Basel</cop><pub>MDPI AG</pub><doi>10.3390/coatings13020348</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2079-6412 |
ispartof | Coatings (Basel), 2023-02, Vol.13 (2), p.348 |
issn | 2079-6412 2079-6412 |
language | eng |
recordid | cdi_proquest_journals_2779540168 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; MDPI - Multidisciplinary Digital Publishing Institute; Alma/SFX Local Collection |
subjects | Comparative analysis Electron tubes Experiments Frequency shift Functional groups Hydrogen bonds Nerve gas Polyhedral oligomeric silsesquioxane Propagation Selectivity Sensors Thioureas |
title | High Performance and Reusable SAW Sensor Coated with Thiourea-Decorated POSS with Different Functional Groups for DMMP Detection |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-04T13%3A33%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High%20Performance%20and%20Reusable%20SAW%20Sensor%20Coated%20with%20Thiourea-Decorated%20POSS%20with%20Different%20Functional%20Groups%20for%20DMMP%20Detection&rft.jtitle=Coatings%20(Basel)&rft.au=Bae,%20Bong-Gyu&rft.date=2023-02-01&rft.volume=13&rft.issue=2&rft.spage=348&rft.pages=348-&rft.issn=2079-6412&rft.eissn=2079-6412&rft_id=info:doi/10.3390/coatings13020348&rft_dat=%3Cgale_proqu%3EA743012156%3C/gale_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2779540168&rft_id=info:pmid/&rft_galeid=A743012156&rfr_iscdi=true |