Selection of the Energy Performance Indicator for Hotels Based on ISO 50001: A Case Study
The work deals with the study of the Energy Planning stage according to the ISO 50001:2018 Standard at the Hotel Punta la Cueva in Cienfuegos, Cuba. The current energy management indicators for hotels are well-studied. However, the study aims to incorporate the variable Degree-Days in the Room Days...
Gespeichert in:
Veröffentlicht in: | Sustainability 2023-01, Vol.15 (2), p.1568 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The work deals with the study of the Energy Planning stage according to the ISO 50001:2018 Standard at the Hotel Punta la Cueva in Cienfuegos, Cuba. The current energy management indicators for hotels are well-studied. However, the study aims to incorporate the variable Degree-Days in the Room Days Occupied (RDO) to establish a correct Baseline and Energy Performance Indicator. The methodology followed is based on the energy management standards of energy review stage. The fundamental results were in obtaining the Energy Baseline with a Coefficient of Determination (R2) of 0.97. One of the opportunities for improvement consisted of the replacement of 80 bulbs 15 W with 9 W LED bulbs. It has an Internal Rate of Return (IRR) of 28%, a Present Value Net Income (NPV) of 71.5 USD, and an Investment Recovery Period (PRI) of 3.6 years. The second opportunity is a preliminary project for a Photovoltaic Solar System on the roofs of the buildings, where it is possible to install 1011 photovoltaic and achieve a generation of 384 kilowatt-peak (kWp). |
---|---|
ISSN: | 2071-1050 2071-1050 |
DOI: | 10.3390/su15021568 |