Verapamil-Sensitive Electrodes: Main Factors Responsible for Analytical Performance and Use in Drug Analysis
It has been established that the correct choice of the plasticizer and the measurement conditions makes it possible to achieve better analytical characteristics of verapamil-sensitive electrodes based on commercially available components in comparison with the best described in the literature. Parti...
Gespeichert in:
Veröffentlicht in: | Journal of analytical chemistry (New York, N.Y.) N.Y.), 2022-12, Vol.77 (12), p.1586-1594 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1594 |
---|---|
container_issue | 12 |
container_start_page | 1586 |
container_title | Journal of analytical chemistry (New York, N.Y.) |
container_volume | 77 |
creator | Faisal A. Salih Novakovskii, Andrei D. Egorov, Vladimir V. |
description | It has been established that the correct choice of the plasticizer and the measurement conditions makes it possible to achieve better analytical characteristics of verapamil-sensitive electrodes based on commercially available components in comparison with the best described in the literature. Particularly, the effect of pH on the verapamil-sensitive electrodes response was found to manifest itself in much more acidic media than might be expected from protolytic equilibrium and is due to the non-exchangeable extraction of verapamil into the membrane phase. The best parameters of selectivity, lower detection limit (4 × 10
−8
M), and potential reproducibility (0.15–0.22 mV) are achieved when using ortho-nitrophenyloctyl ether as a plasticizer and creating conditions that exclude non-exchangeable extraction of verapamil into the membrane. The proposed methods for the determination of verapamil in dosage forms are characterized by simplicity, rapidity, and high metrological characteristics. |
doi_str_mv | 10.1134/S1061934822120127 |
format | Article |
fullrecord | <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_journals_2740274275</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A728077259</galeid><sourcerecordid>A728077259</sourcerecordid><originalsourceid>FETCH-LOGICAL-c385t-11f084d2ae89ec882ef601ea881a3bc22b79583ed46b0cb20117e907f40ad20b3</originalsourceid><addsrcrecordid>eNp1klFrFDEQgBdRsFZ_gG8Bn3zYmsnubbK-HbXVQkXpWV9DNju7pGSTM5Mr9t-bckI5PAkhYeb7hmSYqnoL_AygaT9sgHfQN60SAgQHIZ9VJ9BxVTfQ98_LvaTrx_zL6hXRHee8V9CdVP4nJrM1i_P1BgO57O6RXXi0OcUR6SP7alxgl8bmmIjdIG1joQaPbIqJrYPxD9lZ49l3TCWymGCRmTCyW0JWzE9pN-8xcvS6ejEZT_jm73la3V5e_Dj_Ul9_-3x1vr6ubaNWuQaYuGpHYVD1aJUSOHUc0CgFphmsEIPsV6rBse0GbofyXZDYczm13IyCD81p9W5fd5virx1S1ndxl8ojSAvZ8rKFXD1Rs_GoXZhiTsYujqxeS6G4lGLVF6o-Qs0YSt98DDi5Ej7gz47wZY24OHtUeH8gFCbj7zybHZG-2twcsrBnbYpECSe9TW4x6UED149zoP-Zg-KIvUOFDTOmp2b8X_oDfXmxmA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2740274275</pqid></control><display><type>article</type><title>Verapamil-Sensitive Electrodes: Main Factors Responsible for Analytical Performance and Use in Drug Analysis</title><source>Springer Nature - Complete Springer Journals</source><creator>Faisal A. Salih ; Novakovskii, Andrei D. ; Egorov, Vladimir V.</creator><creatorcontrib>Faisal A. Salih ; Novakovskii, Andrei D. ; Egorov, Vladimir V.</creatorcontrib><description>It has been established that the correct choice of the plasticizer and the measurement conditions makes it possible to achieve better analytical characteristics of verapamil-sensitive electrodes based on commercially available components in comparison with the best described in the literature. Particularly, the effect of pH on the verapamil-sensitive electrodes response was found to manifest itself in much more acidic media than might be expected from protolytic equilibrium and is due to the non-exchangeable extraction of verapamil into the membrane phase. The best parameters of selectivity, lower detection limit (4 × 10
−8
M), and potential reproducibility (0.15–0.22 mV) are achieved when using ortho-nitrophenyloctyl ether as a plasticizer and creating conditions that exclude non-exchangeable extraction of verapamil into the membrane. The proposed methods for the determination of verapamil in dosage forms are characterized by simplicity, rapidity, and high metrological characteristics.</description><identifier>ISSN: 1061-9348</identifier><identifier>EISSN: 1608-3199</identifier><identifier>DOI: 10.1134/S1061934822120127</identifier><language>eng</language><publisher>Moscow: Pleiades Publishing</publisher><subject>Analysis ; Analytical Chemistry ; Chemistry ; Chemistry and Materials Science ; Electrodes ; Hydrogen-ion concentration ; Mathematical analysis ; Membranes ; Plasticizers ; Selectivity ; Verapamil</subject><ispartof>Journal of analytical chemistry (New York, N.Y.), 2022-12, Vol.77 (12), p.1586-1594</ispartof><rights>Pleiades Publishing, Ltd. 2022. ISSN 1061-9348, Journal of Analytical Chemistry, 2022, Vol. 77, No. 12, pp. 1586–1594. © Pleiades Publishing, Ltd., 2022.</rights><rights>COPYRIGHT 2022 Springer</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c385t-11f084d2ae89ec882ef601ea881a3bc22b79583ed46b0cb20117e907f40ad20b3</citedby><cites>FETCH-LOGICAL-c385t-11f084d2ae89ec882ef601ea881a3bc22b79583ed46b0cb20117e907f40ad20b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1134/S1061934822120127$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1134/S1061934822120127$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,778,782,27911,27912,41475,42544,51306</link.rule.ids></links><search><creatorcontrib>Faisal A. Salih</creatorcontrib><creatorcontrib>Novakovskii, Andrei D.</creatorcontrib><creatorcontrib>Egorov, Vladimir V.</creatorcontrib><title>Verapamil-Sensitive Electrodes: Main Factors Responsible for Analytical Performance and Use in Drug Analysis</title><title>Journal of analytical chemistry (New York, N.Y.)</title><addtitle>J Anal Chem</addtitle><description>It has been established that the correct choice of the plasticizer and the measurement conditions makes it possible to achieve better analytical characteristics of verapamil-sensitive electrodes based on commercially available components in comparison with the best described in the literature. Particularly, the effect of pH on the verapamil-sensitive electrodes response was found to manifest itself in much more acidic media than might be expected from protolytic equilibrium and is due to the non-exchangeable extraction of verapamil into the membrane phase. The best parameters of selectivity, lower detection limit (4 × 10
−8
M), and potential reproducibility (0.15–0.22 mV) are achieved when using ortho-nitrophenyloctyl ether as a plasticizer and creating conditions that exclude non-exchangeable extraction of verapamil into the membrane. The proposed methods for the determination of verapamil in dosage forms are characterized by simplicity, rapidity, and high metrological characteristics.</description><subject>Analysis</subject><subject>Analytical Chemistry</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Electrodes</subject><subject>Hydrogen-ion concentration</subject><subject>Mathematical analysis</subject><subject>Membranes</subject><subject>Plasticizers</subject><subject>Selectivity</subject><subject>Verapamil</subject><issn>1061-9348</issn><issn>1608-3199</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp1klFrFDEQgBdRsFZ_gG8Bn3zYmsnubbK-HbXVQkXpWV9DNju7pGSTM5Mr9t-bckI5PAkhYeb7hmSYqnoL_AygaT9sgHfQN60SAgQHIZ9VJ9BxVTfQ98_LvaTrx_zL6hXRHee8V9CdVP4nJrM1i_P1BgO57O6RXXi0OcUR6SP7alxgl8bmmIjdIG1joQaPbIqJrYPxD9lZ49l3TCWymGCRmTCyW0JWzE9pN-8xcvS6ejEZT_jm73la3V5e_Dj_Ul9_-3x1vr6ubaNWuQaYuGpHYVD1aJUSOHUc0CgFphmsEIPsV6rBse0GbofyXZDYczm13IyCD81p9W5fd5virx1S1ndxl8ojSAvZ8rKFXD1Rs_GoXZhiTsYujqxeS6G4lGLVF6o-Qs0YSt98DDi5Ej7gz47wZY24OHtUeH8gFCbj7zybHZG-2twcsrBnbYpECSe9TW4x6UED149zoP-Zg-KIvUOFDTOmp2b8X_oDfXmxmA</recordid><startdate>20221201</startdate><enddate>20221201</enddate><creator>Faisal A. Salih</creator><creator>Novakovskii, Andrei D.</creator><creator>Egorov, Vladimir V.</creator><general>Pleiades Publishing</general><general>Springer</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ISR</scope></search><sort><creationdate>20221201</creationdate><title>Verapamil-Sensitive Electrodes: Main Factors Responsible for Analytical Performance and Use in Drug Analysis</title><author>Faisal A. Salih ; Novakovskii, Andrei D. ; Egorov, Vladimir V.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c385t-11f084d2ae89ec882ef601ea881a3bc22b79583ed46b0cb20117e907f40ad20b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Analysis</topic><topic>Analytical Chemistry</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Electrodes</topic><topic>Hydrogen-ion concentration</topic><topic>Mathematical analysis</topic><topic>Membranes</topic><topic>Plasticizers</topic><topic>Selectivity</topic><topic>Verapamil</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Faisal A. Salih</creatorcontrib><creatorcontrib>Novakovskii, Andrei D.</creatorcontrib><creatorcontrib>Egorov, Vladimir V.</creatorcontrib><collection>CrossRef</collection><collection>Gale In Context: Science</collection><jtitle>Journal of analytical chemistry (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Faisal A. Salih</au><au>Novakovskii, Andrei D.</au><au>Egorov, Vladimir V.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Verapamil-Sensitive Electrodes: Main Factors Responsible for Analytical Performance and Use in Drug Analysis</atitle><jtitle>Journal of analytical chemistry (New York, N.Y.)</jtitle><stitle>J Anal Chem</stitle><date>2022-12-01</date><risdate>2022</risdate><volume>77</volume><issue>12</issue><spage>1586</spage><epage>1594</epage><pages>1586-1594</pages><issn>1061-9348</issn><eissn>1608-3199</eissn><abstract>It has been established that the correct choice of the plasticizer and the measurement conditions makes it possible to achieve better analytical characteristics of verapamil-sensitive electrodes based on commercially available components in comparison with the best described in the literature. Particularly, the effect of pH on the verapamil-sensitive electrodes response was found to manifest itself in much more acidic media than might be expected from protolytic equilibrium and is due to the non-exchangeable extraction of verapamil into the membrane phase. The best parameters of selectivity, lower detection limit (4 × 10
−8
M), and potential reproducibility (0.15–0.22 mV) are achieved when using ortho-nitrophenyloctyl ether as a plasticizer and creating conditions that exclude non-exchangeable extraction of verapamil into the membrane. The proposed methods for the determination of verapamil in dosage forms are characterized by simplicity, rapidity, and high metrological characteristics.</abstract><cop>Moscow</cop><pub>Pleiades Publishing</pub><doi>10.1134/S1061934822120127</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1061-9348 |
ispartof | Journal of analytical chemistry (New York, N.Y.), 2022-12, Vol.77 (12), p.1586-1594 |
issn | 1061-9348 1608-3199 |
language | eng |
recordid | cdi_proquest_journals_2740274275 |
source | Springer Nature - Complete Springer Journals |
subjects | Analysis Analytical Chemistry Chemistry Chemistry and Materials Science Electrodes Hydrogen-ion concentration Mathematical analysis Membranes Plasticizers Selectivity Verapamil |
title | Verapamil-Sensitive Electrodes: Main Factors Responsible for Analytical Performance and Use in Drug Analysis |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T21%3A42%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Verapamil-Sensitive%20Electrodes:%20Main%20Factors%20Responsible%20for%20Analytical%20Performance%20and%20Use%20in%20Drug%20Analysis&rft.jtitle=Journal%20of%20analytical%20chemistry%20(New%20York,%20N.Y.)&rft.au=Faisal%20A.%20Salih&rft.date=2022-12-01&rft.volume=77&rft.issue=12&rft.spage=1586&rft.epage=1594&rft.pages=1586-1594&rft.issn=1061-9348&rft.eissn=1608-3199&rft_id=info:doi/10.1134/S1061934822120127&rft_dat=%3Cgale_proqu%3EA728077259%3C/gale_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2740274275&rft_id=info:pmid/&rft_galeid=A728077259&rfr_iscdi=true |