Significance of Metrological Tools in an ISO 17025 Accredited Quality System for a Biological Evaluation Facility

Maintaining a biological evaluation facility with reliability and acceptance is one of the critical issues in the field of medical device development. Establishing metrological traceability in the biological evaluation is a complex process when compared to the traceability in technical and industria...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:MĀPAN : journal of Metrology Society of India 2022-09, Vol.37 (3), p.683-691
Hauptverfasser: Joseph, Leena, Ramesh, P., Remya, N. S., Arumugham, V., Rajesh, R. P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 691
container_issue 3
container_start_page 683
container_title MĀPAN : journal of Metrology Society of India
container_volume 37
creator Joseph, Leena
Ramesh, P.
Remya, N. S.
Arumugham, V.
Rajesh, R. P.
description Maintaining a biological evaluation facility with reliability and acceptance is one of the critical issues in the field of medical device development. Establishing metrological traceability in the biological evaluation is a complex process when compared to the traceability in technical and industrial calibration and testing. In the development of medical devices, the risk of biocompatibility of biomaterials caused by chemical toxicity, physical characteristics like surface properties, presence of particulates, forces on surrounding tissue that might contribute to an unwanted tissue response, etc. has to be evaluated for their safe use. In a biological evaluation facility when reliability in test results and performance of the medical device are required for assuring patient safety, due considerations are to be given to testing and traceable calibration of associated equipment. Evidence for an established traceability chain through the use of metrological tools is one of the essential requirements for getting regulatory approval also. Therefore, regular conduct of calibrations and use of Reference Materials (RMs) in a biological evaluation facility is of utmost importance owing to the safety of patients. For the above reasons, this article will give a clear picture of the role of an accredited metrological system in the biological evaluation of materials and medical devices.
doi_str_mv 10.1007/s12647-021-00517-2
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2729940932</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2729940932</sourcerecordid><originalsourceid>FETCH-LOGICAL-c319t-64ea58f1ccfb209e204d95060cf9b5a764d834044fbd70e34c566a6de01cd8203</originalsourceid><addsrcrecordid>eNp9kM1KAzEURgdRsFZfwFXAdfTmZyaTZS2tFpQireuQZpKSMp20yVTo2zvtiO5c5RLO993LybJ7Ao8EQDwlQgsuMFCCAXIiML3IBiAFx7LM2eV5BsxkDtfZTUobgKIEKQfZfuHXjXfe6MZYFBx6t20MdVh3PzVahlAn5BukGzRbzBERQHM0Mibayre2Qh8HXfv2iBbH1NotciEijZ79b8HkS9cH3frQoKk2_sTeZldO18ne_bzD7HM6WY5f8dv8ZTYevWHDiGxxwa3OS0eMcSsK0lLgVXd-AcbJVa5FwauSceDcrSoBlnGTF4UuKgvEVCUFNswe-t5dDPuDTa3ahENsupWKCiolB8loR9GeMjGkFK1Tu-i3Oh4VAXVSq3q1qlOrzmrVKcT6UOrgZm3jX_U_qW8IP3tN</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2729940932</pqid></control><display><type>article</type><title>Significance of Metrological Tools in an ISO 17025 Accredited Quality System for a Biological Evaluation Facility</title><source>SpringerLink Journals</source><creator>Joseph, Leena ; Ramesh, P. ; Remya, N. S. ; Arumugham, V. ; Rajesh, R. P.</creator><creatorcontrib>Joseph, Leena ; Ramesh, P. ; Remya, N. S. ; Arumugham, V. ; Rajesh, R. P.</creatorcontrib><description>Maintaining a biological evaluation facility with reliability and acceptance is one of the critical issues in the field of medical device development. Establishing metrological traceability in the biological evaluation is a complex process when compared to the traceability in technical and industrial calibration and testing. In the development of medical devices, the risk of biocompatibility of biomaterials caused by chemical toxicity, physical characteristics like surface properties, presence of particulates, forces on surrounding tissue that might contribute to an unwanted tissue response, etc. has to be evaluated for their safe use. In a biological evaluation facility when reliability in test results and performance of the medical device are required for assuring patient safety, due considerations are to be given to testing and traceable calibration of associated equipment. Evidence for an established traceability chain through the use of metrological tools is one of the essential requirements for getting regulatory approval also. Therefore, regular conduct of calibrations and use of Reference Materials (RMs) in a biological evaluation facility is of utmost importance owing to the safety of patients. For the above reasons, this article will give a clear picture of the role of an accredited metrological system in the biological evaluation of materials and medical devices.</description><identifier>ISSN: 0970-3950</identifier><identifier>EISSN: 0974-9853</identifier><identifier>DOI: 10.1007/s12647-021-00517-2</identifier><language>eng</language><publisher>New Delhi: Springer India</publisher><subject>Biocompatibility ; Biomedical materials ; Calibration ; Mathematical and Computational Physics ; Mathematical Methods in Physics ; Measurement Science and Instrumentation ; Medical equipment ; Medical materials ; Medical technology ; Metrology ; Numerical and Computational Physics ; Particulates ; Patient safety ; Physical properties ; Physics ; Physics and Astronomy ; Regulatory approval ; Reliability analysis ; Review Paper ; Safety ; Simulation ; Surface properties ; Theoretical ; Toxicity</subject><ispartof>MĀPAN : journal of Metrology Society of India, 2022-09, Vol.37 (3), p.683-691</ispartof><rights>Metrology Society of India 2021</rights><rights>Metrology Society of India 2021.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c319t-64ea58f1ccfb209e204d95060cf9b5a764d834044fbd70e34c566a6de01cd8203</citedby><cites>FETCH-LOGICAL-c319t-64ea58f1ccfb209e204d95060cf9b5a764d834044fbd70e34c566a6de01cd8203</cites><orcidid>0000-0003-2517-2725</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s12647-021-00517-2$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s12647-021-00517-2$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,41488,42557,51319</link.rule.ids></links><search><creatorcontrib>Joseph, Leena</creatorcontrib><creatorcontrib>Ramesh, P.</creatorcontrib><creatorcontrib>Remya, N. S.</creatorcontrib><creatorcontrib>Arumugham, V.</creatorcontrib><creatorcontrib>Rajesh, R. P.</creatorcontrib><title>Significance of Metrological Tools in an ISO 17025 Accredited Quality System for a Biological Evaluation Facility</title><title>MĀPAN : journal of Metrology Society of India</title><addtitle>MAPAN</addtitle><description>Maintaining a biological evaluation facility with reliability and acceptance is one of the critical issues in the field of medical device development. Establishing metrological traceability in the biological evaluation is a complex process when compared to the traceability in technical and industrial calibration and testing. In the development of medical devices, the risk of biocompatibility of biomaterials caused by chemical toxicity, physical characteristics like surface properties, presence of particulates, forces on surrounding tissue that might contribute to an unwanted tissue response, etc. has to be evaluated for their safe use. In a biological evaluation facility when reliability in test results and performance of the medical device are required for assuring patient safety, due considerations are to be given to testing and traceable calibration of associated equipment. Evidence for an established traceability chain through the use of metrological tools is one of the essential requirements for getting regulatory approval also. Therefore, regular conduct of calibrations and use of Reference Materials (RMs) in a biological evaluation facility is of utmost importance owing to the safety of patients. For the above reasons, this article will give a clear picture of the role of an accredited metrological system in the biological evaluation of materials and medical devices.</description><subject>Biocompatibility</subject><subject>Biomedical materials</subject><subject>Calibration</subject><subject>Mathematical and Computational Physics</subject><subject>Mathematical Methods in Physics</subject><subject>Measurement Science and Instrumentation</subject><subject>Medical equipment</subject><subject>Medical materials</subject><subject>Medical technology</subject><subject>Metrology</subject><subject>Numerical and Computational Physics</subject><subject>Particulates</subject><subject>Patient safety</subject><subject>Physical properties</subject><subject>Physics</subject><subject>Physics and Astronomy</subject><subject>Regulatory approval</subject><subject>Reliability analysis</subject><subject>Review Paper</subject><subject>Safety</subject><subject>Simulation</subject><subject>Surface properties</subject><subject>Theoretical</subject><subject>Toxicity</subject><issn>0970-3950</issn><issn>0974-9853</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kM1KAzEURgdRsFZfwFXAdfTmZyaTZS2tFpQireuQZpKSMp20yVTo2zvtiO5c5RLO993LybJ7Ao8EQDwlQgsuMFCCAXIiML3IBiAFx7LM2eV5BsxkDtfZTUobgKIEKQfZfuHXjXfe6MZYFBx6t20MdVh3PzVahlAn5BukGzRbzBERQHM0Mibayre2Qh8HXfv2iBbH1NotciEijZ79b8HkS9cH3frQoKk2_sTeZldO18ne_bzD7HM6WY5f8dv8ZTYevWHDiGxxwa3OS0eMcSsK0lLgVXd-AcbJVa5FwauSceDcrSoBlnGTF4UuKgvEVCUFNswe-t5dDPuDTa3ahENsupWKCiolB8loR9GeMjGkFK1Tu-i3Oh4VAXVSq3q1qlOrzmrVKcT6UOrgZm3jX_U_qW8IP3tN</recordid><startdate>20220901</startdate><enddate>20220901</enddate><creator>Joseph, Leena</creator><creator>Ramesh, P.</creator><creator>Remya, N. S.</creator><creator>Arumugham, V.</creator><creator>Rajesh, R. P.</creator><general>Springer India</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0003-2517-2725</orcidid></search><sort><creationdate>20220901</creationdate><title>Significance of Metrological Tools in an ISO 17025 Accredited Quality System for a Biological Evaluation Facility</title><author>Joseph, Leena ; Ramesh, P. ; Remya, N. S. ; Arumugham, V. ; Rajesh, R. P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c319t-64ea58f1ccfb209e204d95060cf9b5a764d834044fbd70e34c566a6de01cd8203</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Biocompatibility</topic><topic>Biomedical materials</topic><topic>Calibration</topic><topic>Mathematical and Computational Physics</topic><topic>Mathematical Methods in Physics</topic><topic>Measurement Science and Instrumentation</topic><topic>Medical equipment</topic><topic>Medical materials</topic><topic>Medical technology</topic><topic>Metrology</topic><topic>Numerical and Computational Physics</topic><topic>Particulates</topic><topic>Patient safety</topic><topic>Physical properties</topic><topic>Physics</topic><topic>Physics and Astronomy</topic><topic>Regulatory approval</topic><topic>Reliability analysis</topic><topic>Review Paper</topic><topic>Safety</topic><topic>Simulation</topic><topic>Surface properties</topic><topic>Theoretical</topic><topic>Toxicity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Joseph, Leena</creatorcontrib><creatorcontrib>Ramesh, P.</creatorcontrib><creatorcontrib>Remya, N. S.</creatorcontrib><creatorcontrib>Arumugham, V.</creatorcontrib><creatorcontrib>Rajesh, R. P.</creatorcontrib><collection>CrossRef</collection><jtitle>MĀPAN : journal of Metrology Society of India</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Joseph, Leena</au><au>Ramesh, P.</au><au>Remya, N. S.</au><au>Arumugham, V.</au><au>Rajesh, R. P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Significance of Metrological Tools in an ISO 17025 Accredited Quality System for a Biological Evaluation Facility</atitle><jtitle>MĀPAN : journal of Metrology Society of India</jtitle><stitle>MAPAN</stitle><date>2022-09-01</date><risdate>2022</risdate><volume>37</volume><issue>3</issue><spage>683</spage><epage>691</epage><pages>683-691</pages><issn>0970-3950</issn><eissn>0974-9853</eissn><abstract>Maintaining a biological evaluation facility with reliability and acceptance is one of the critical issues in the field of medical device development. Establishing metrological traceability in the biological evaluation is a complex process when compared to the traceability in technical and industrial calibration and testing. In the development of medical devices, the risk of biocompatibility of biomaterials caused by chemical toxicity, physical characteristics like surface properties, presence of particulates, forces on surrounding tissue that might contribute to an unwanted tissue response, etc. has to be evaluated for their safe use. In a biological evaluation facility when reliability in test results and performance of the medical device are required for assuring patient safety, due considerations are to be given to testing and traceable calibration of associated equipment. Evidence for an established traceability chain through the use of metrological tools is one of the essential requirements for getting regulatory approval also. Therefore, regular conduct of calibrations and use of Reference Materials (RMs) in a biological evaluation facility is of utmost importance owing to the safety of patients. For the above reasons, this article will give a clear picture of the role of an accredited metrological system in the biological evaluation of materials and medical devices.</abstract><cop>New Delhi</cop><pub>Springer India</pub><doi>10.1007/s12647-021-00517-2</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0003-2517-2725</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0970-3950
ispartof MĀPAN : journal of Metrology Society of India, 2022-09, Vol.37 (3), p.683-691
issn 0970-3950
0974-9853
language eng
recordid cdi_proquest_journals_2729940932
source SpringerLink Journals
subjects Biocompatibility
Biomedical materials
Calibration
Mathematical and Computational Physics
Mathematical Methods in Physics
Measurement Science and Instrumentation
Medical equipment
Medical materials
Medical technology
Metrology
Numerical and Computational Physics
Particulates
Patient safety
Physical properties
Physics
Physics and Astronomy
Regulatory approval
Reliability analysis
Review Paper
Safety
Simulation
Surface properties
Theoretical
Toxicity
title Significance of Metrological Tools in an ISO 17025 Accredited Quality System for a Biological Evaluation Facility
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T01%3A03%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Significance%20of%20Metrological%20Tools%20in%20an%20ISO%2017025%20Accredited%20Quality%20System%20for%20a%20Biological%20Evaluation%20Facility&rft.jtitle=M%C4%80PAN%20:%20journal%20of%20Metrology%20Society%20of%20India&rft.au=Joseph,%20Leena&rft.date=2022-09-01&rft.volume=37&rft.issue=3&rft.spage=683&rft.epage=691&rft.pages=683-691&rft.issn=0970-3950&rft.eissn=0974-9853&rft_id=info:doi/10.1007/s12647-021-00517-2&rft_dat=%3Cproquest_cross%3E2729940932%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2729940932&rft_id=info:pmid/&rfr_iscdi=true