Indoor thermal environment and energy performance in a central air heating system using a heat pump for a house with underfloor space for heat distribution
Central air heating systems with heat pumps can use the underfloor space, rather than air ducts, for heat distribution in houses. To minimize the energy consumption, the actual thermal environment and energy performance of these systems must be evaluated through continuous field measurements. This s...
Gespeichert in:
Veröffentlicht in: | Building services engineering research & technology 2022-11, Vol.43 (6), p.755-766 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 766 |
---|---|
container_issue | 6 |
container_start_page | 755 |
container_title | Building services engineering research & technology |
container_volume | 43 |
creator | Kindaichi, Sayaka Kindaichi, Tomonori |
description | Central air heating systems with heat pumps can use the underfloor space, rather than air ducts, for heat distribution in houses. To minimize the energy consumption, the actual thermal environment and energy performance of these systems must be evaluated through continuous field measurements. This study evaluates the thermal environment, operational characteristics, and energy performance of a central air heating system with a heat pump during two winters in a two-story house in Japan. In the first winter (i.e., before case), the supply air was automatically controlled at a relatively high average temperature of 45°C with low air flow rates, resulting in a non-uniform temperature distribution among the rooms and low energy efficiency. In the second winter (i.e., after case), an increase in the fan speed improved the heat distribution, with operational conditions of high air flow rates at a lower average temperature of 39°C. This led to average energy savings of 11% while maintaining thermal comfort. |
doi_str_mv | 10.1177/01436244221117356 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2716464339</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_01436244221117356</sage_id><sourcerecordid>2716464339</sourcerecordid><originalsourceid>FETCH-LOGICAL-c242t-9f29327e9b1d96953430680ccc717e97076a4f993432c8cf1b20aadbcac2ad763</originalsourceid><addsrcrecordid>eNp1kc1KAzEUhYMoWKsP4C7gejR_TZqlFH8KBTe6HjKZTJvSScYko_RZfFmTVnAhri7n3O-cu7gAXGN0i7EQdwgzygljhOCs6YyfgAlmQlRozuQpmJR9VYBzcBHjFqEMITQBX0vXeh9g2pjQqx007sMG73rjElSuzdqE9R4OJnQ-A04baB1UUGcgZF7ZADdGJevWMO5jMj0cYxHqYMNh7AeYo0X7MRr4adMGjq7NhbtyOA4qdxbiwLc2pmCbMVnvLsFZp3bRXP3MKXh7fHhdPFerl6fl4n5VacJIqmRHJCXCyAa3kssZZRTxOdJaC5xdgQRXrJMy-0TPdYcbgpRqG600Ua3gdApujr1D8O-jiane-jG4fLImAnPGGaUyU_hI6eBjDKarh2B7FfY1RnX5Qf3nBzlze8xEtTa_rf8HvgHT64kD</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2716464339</pqid></control><display><type>article</type><title>Indoor thermal environment and energy performance in a central air heating system using a heat pump for a house with underfloor space for heat distribution</title><source>SAGE Complete A-Z List</source><creator>Kindaichi, Sayaka ; Kindaichi, Tomonori</creator><creatorcontrib>Kindaichi, Sayaka ; Kindaichi, Tomonori</creatorcontrib><description>Central air heating systems with heat pumps can use the underfloor space, rather than air ducts, for heat distribution in houses. To minimize the energy consumption, the actual thermal environment and energy performance of these systems must be evaluated through continuous field measurements. This study evaluates the thermal environment, operational characteristics, and energy performance of a central air heating system with a heat pump during two winters in a two-story house in Japan. In the first winter (i.e., before case), the supply air was automatically controlled at a relatively high average temperature of 45°C with low air flow rates, resulting in a non-uniform temperature distribution among the rooms and low energy efficiency. In the second winter (i.e., after case), an increase in the fan speed improved the heat distribution, with operational conditions of high air flow rates at a lower average temperature of 39°C. This led to average energy savings of 11% while maintaining thermal comfort.</description><identifier>ISSN: 0143-6244</identifier><identifier>EISSN: 1477-0849</identifier><identifier>DOI: 10.1177/01436244221117356</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Air ducts ; Air flow ; Energy ; Energy consumption ; Flow velocity ; Heat ; Heat distribution ; Heat pumps ; Heating ; Heating systems ; Indoor environments ; Temperature distribution ; Thermal comfort ; Thermal environments ; Winter</subject><ispartof>Building services engineering research & technology, 2022-11, Vol.43 (6), p.755-766</ispartof><rights>The Author(s) 2022</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c242t-9f29327e9b1d96953430680ccc717e97076a4f993432c8cf1b20aadbcac2ad763</citedby><cites>FETCH-LOGICAL-c242t-9f29327e9b1d96953430680ccc717e97076a4f993432c8cf1b20aadbcac2ad763</cites><orcidid>0000-0003-1500-3397</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/01436244221117356$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/01436244221117356$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids></links><search><creatorcontrib>Kindaichi, Sayaka</creatorcontrib><creatorcontrib>Kindaichi, Tomonori</creatorcontrib><title>Indoor thermal environment and energy performance in a central air heating system using a heat pump for a house with underfloor space for heat distribution</title><title>Building services engineering research & technology</title><description>Central air heating systems with heat pumps can use the underfloor space, rather than air ducts, for heat distribution in houses. To minimize the energy consumption, the actual thermal environment and energy performance of these systems must be evaluated through continuous field measurements. This study evaluates the thermal environment, operational characteristics, and energy performance of a central air heating system with a heat pump during two winters in a two-story house in Japan. In the first winter (i.e., before case), the supply air was automatically controlled at a relatively high average temperature of 45°C with low air flow rates, resulting in a non-uniform temperature distribution among the rooms and low energy efficiency. In the second winter (i.e., after case), an increase in the fan speed improved the heat distribution, with operational conditions of high air flow rates at a lower average temperature of 39°C. This led to average energy savings of 11% while maintaining thermal comfort.</description><subject>Air ducts</subject><subject>Air flow</subject><subject>Energy</subject><subject>Energy consumption</subject><subject>Flow velocity</subject><subject>Heat</subject><subject>Heat distribution</subject><subject>Heat pumps</subject><subject>Heating</subject><subject>Heating systems</subject><subject>Indoor environments</subject><subject>Temperature distribution</subject><subject>Thermal comfort</subject><subject>Thermal environments</subject><subject>Winter</subject><issn>0143-6244</issn><issn>1477-0849</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp1kc1KAzEUhYMoWKsP4C7gejR_TZqlFH8KBTe6HjKZTJvSScYko_RZfFmTVnAhri7n3O-cu7gAXGN0i7EQdwgzygljhOCs6YyfgAlmQlRozuQpmJR9VYBzcBHjFqEMITQBX0vXeh9g2pjQqx007sMG73rjElSuzdqE9R4OJnQ-A04baB1UUGcgZF7ZADdGJevWMO5jMj0cYxHqYMNh7AeYo0X7MRr4adMGjq7NhbtyOA4qdxbiwLc2pmCbMVnvLsFZp3bRXP3MKXh7fHhdPFerl6fl4n5VacJIqmRHJCXCyAa3kssZZRTxOdJaC5xdgQRXrJMy-0TPdYcbgpRqG600Ua3gdApujr1D8O-jiane-jG4fLImAnPGGaUyU_hI6eBjDKarh2B7FfY1RnX5Qf3nBzlze8xEtTa_rf8HvgHT64kD</recordid><startdate>202211</startdate><enddate>202211</enddate><creator>Kindaichi, Sayaka</creator><creator>Kindaichi, Tomonori</creator><general>SAGE Publications</general><general>Sage Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>U9A</scope><orcidid>https://orcid.org/0000-0003-1500-3397</orcidid></search><sort><creationdate>202211</creationdate><title>Indoor thermal environment and energy performance in a central air heating system using a heat pump for a house with underfloor space for heat distribution</title><author>Kindaichi, Sayaka ; Kindaichi, Tomonori</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c242t-9f29327e9b1d96953430680ccc717e97076a4f993432c8cf1b20aadbcac2ad763</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Air ducts</topic><topic>Air flow</topic><topic>Energy</topic><topic>Energy consumption</topic><topic>Flow velocity</topic><topic>Heat</topic><topic>Heat distribution</topic><topic>Heat pumps</topic><topic>Heating</topic><topic>Heating systems</topic><topic>Indoor environments</topic><topic>Temperature distribution</topic><topic>Thermal comfort</topic><topic>Thermal environments</topic><topic>Winter</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kindaichi, Sayaka</creatorcontrib><creatorcontrib>Kindaichi, Tomonori</creatorcontrib><collection>CrossRef</collection><jtitle>Building services engineering research & technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kindaichi, Sayaka</au><au>Kindaichi, Tomonori</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Indoor thermal environment and energy performance in a central air heating system using a heat pump for a house with underfloor space for heat distribution</atitle><jtitle>Building services engineering research & technology</jtitle><date>2022-11</date><risdate>2022</risdate><volume>43</volume><issue>6</issue><spage>755</spage><epage>766</epage><pages>755-766</pages><issn>0143-6244</issn><eissn>1477-0849</eissn><abstract>Central air heating systems with heat pumps can use the underfloor space, rather than air ducts, for heat distribution in houses. To minimize the energy consumption, the actual thermal environment and energy performance of these systems must be evaluated through continuous field measurements. This study evaluates the thermal environment, operational characteristics, and energy performance of a central air heating system with a heat pump during two winters in a two-story house in Japan. In the first winter (i.e., before case), the supply air was automatically controlled at a relatively high average temperature of 45°C with low air flow rates, resulting in a non-uniform temperature distribution among the rooms and low energy efficiency. In the second winter (i.e., after case), an increase in the fan speed improved the heat distribution, with operational conditions of high air flow rates at a lower average temperature of 39°C. This led to average energy savings of 11% while maintaining thermal comfort.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><doi>10.1177/01436244221117356</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0003-1500-3397</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0143-6244 |
ispartof | Building services engineering research & technology, 2022-11, Vol.43 (6), p.755-766 |
issn | 0143-6244 1477-0849 |
language | eng |
recordid | cdi_proquest_journals_2716464339 |
source | SAGE Complete A-Z List |
subjects | Air ducts Air flow Energy Energy consumption Flow velocity Heat Heat distribution Heat pumps Heating Heating systems Indoor environments Temperature distribution Thermal comfort Thermal environments Winter |
title | Indoor thermal environment and energy performance in a central air heating system using a heat pump for a house with underfloor space for heat distribution |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T01%3A54%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Indoor%20thermal%20environment%20and%20energy%20performance%20in%20a%20central%20air%20heating%20system%20using%20a%20heat%20pump%20for%20a%20house%20with%20underfloor%20space%20for%20heat%20distribution&rft.jtitle=Building%20services%20engineering%20research%20&%20technology&rft.au=Kindaichi,%20Sayaka&rft.date=2022-11&rft.volume=43&rft.issue=6&rft.spage=755&rft.epage=766&rft.pages=755-766&rft.issn=0143-6244&rft.eissn=1477-0849&rft_id=info:doi/10.1177/01436244221117356&rft_dat=%3Cproquest_cross%3E2716464339%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2716464339&rft_id=info:pmid/&rft_sage_id=10.1177_01436244221117356&rfr_iscdi=true |