30‐4: Requirements for Reliable Display Sparkle Contrast Measurement: Analysis in Spatial Frequency Domain

Display Sparkle contrast can be measured in various conditions. However, no criteria are shown for avoiding aliasing effect which could cause undesired error. We show the criteria and demonstrate the example of the undesired error.

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:SID International Symposium Digest of technical papers 2022-06, Vol.53 (1), p.361-364
Hauptverfasser: Isshiki, Masanobu, Endo, Yukio
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Display Sparkle contrast can be measured in various conditions. However, no criteria are shown for avoiding aliasing effect which could cause undesired error. We show the criteria and demonstrate the example of the undesired error.