Can Echocardiography Adjust Corrected Contrast Injection Condition in Coronary CT Angiography?

Purpose: The purposes were to search which factor of cardiac function in echocardiography correlates with the CT value, to correct contrast injection conditions with cardiac function in addition to suppress error in the contrast effect between patients, and to achieve the target CT value (350 HU) in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Japanese Journal of Radiological Technology 2022, Vol.78(5), pp.484-491
Hauptverfasser: Ogata, Sho, Nagatomo, Daisuke, Mizoguchi, Kouji, Teshima, Toshihiro, Hotta, Atsushi
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 491
container_issue 5
container_start_page 484
container_title Japanese Journal of Radiological Technology
container_volume 78
creator Ogata, Sho
Nagatomo, Daisuke
Mizoguchi, Kouji
Teshima, Toshihiro
Hotta, Atsushi
description Purpose: The purposes were to search which factor of cardiac function in echocardiography correlates with the CT value, to correct contrast injection conditions with cardiac function in addition to suppress error in the contrast effect between patients, and to achieve the target CT value (350 HU) in coronary computed tomography angiography (CCTA). Methods: In 112 patients (conventional group), the contrast material was administered at a fractional dose (FD) of 21 mgI/kg/s. We measured the aortic CT value in the coronary origin part. In 112 patients (correction group), the contrast material was administered at corrected injection conditions with the most correlated functional factor and CT value. Results: The CT value of the conventional group was an average of 400.8±51.5 HU. The most correlated factor with the CT value was stroke volume [SV (r=−0.555)]. The CT value of the conventional group was an average of 360±46 HU. The case of the aim CT level was improved from 46% to 74%. In the correction group, the average value of FD was 18.5 mgI/kg/s. This enabled the reduction of the contrast material in 95% of patients. Conclusion: The best correlation was obtained between the CT value of coronary arteries and SV. The contrast medium injection conditions were corrected for cardiac function in addition to body weight. As a result, we were able to control the CCTA target CT value of 300 to 400 HU at our hospital.
doi_str_mv 10.6009/jjrt.2022-1132
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2672376257</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2672376257</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2242-1bbdb05d770fd4f6d3eddee3f89e97df2ebc4b4a074f2b6e59200ec83fc9f8e63</originalsourceid><addsrcrecordid>eNo9kDFPwzAQhS0EolXpyogiMac4tpPYE6pCgUqVWMqK5djnNlGbFCcZ-u9xSJvFvnv-7vn0EHqM8CLBWLyUpWsXBBMSRhElN2gacR6FjHN6i6aYJiJkFMcTNG-aIsd-wkuY3aMJjSmJhKBT9JOpKljpfa2VM0W9c-q0PwdLU3ZNG2S1c6BbML6qWqe8tK5KrxR11Uum-K-KvnF1pdw5yLbBstpdjV4f0J1Vhwbml3uGvt9X2-wz3Hx9rLPlJtSEML9-npscxyZNsTXMJoaCMQDUcgEiNZZArlnOFE6ZJXkCsSAYg-bUamE5JHSGngffk6t_O2haWdadq_yXkiQpoWlC4tRTi4HSrm4aB1aeXHH0a8sIyz5R2Scq-0Rln6gfeLrYdvkRzIhf8_PA2wCUTat2MALKtYU-wOCXchn3x-g7Puu9chIq-gf38ot2</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2672376257</pqid></control><display><type>article</type><title>Can Echocardiography Adjust Corrected Contrast Injection Condition in Coronary CT Angiography?</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Ogata, Sho ; Nagatomo, Daisuke ; Mizoguchi, Kouji ; Teshima, Toshihiro ; Hotta, Atsushi</creator><creatorcontrib>Ogata, Sho ; Nagatomo, Daisuke ; Mizoguchi, Kouji ; Teshima, Toshihiro ; Hotta, Atsushi</creatorcontrib><description>Purpose: The purposes were to search which factor of cardiac function in echocardiography correlates with the CT value, to correct contrast injection conditions with cardiac function in addition to suppress error in the contrast effect between patients, and to achieve the target CT value (350 HU) in coronary computed tomography angiography (CCTA). Methods: In 112 patients (conventional group), the contrast material was administered at a fractional dose (FD) of 21 mgI/kg/s. We measured the aortic CT value in the coronary origin part. In 112 patients (correction group), the contrast material was administered at corrected injection conditions with the most correlated functional factor and CT value. Results: The CT value of the conventional group was an average of 400.8±51.5 HU. The most correlated factor with the CT value was stroke volume [SV (r=−0.555)]. The CT value of the conventional group was an average of 360±46 HU. The case of the aim CT level was improved from 46% to 74%. In the correction group, the average value of FD was 18.5 mgI/kg/s. This enabled the reduction of the contrast material in 95% of patients. Conclusion: The best correlation was obtained between the CT value of coronary arteries and SV. The contrast medium injection conditions were corrected for cardiac function in addition to body weight. As a result, we were able to control the CCTA target CT value of 300 to 400 HU at our hospital.</description><identifier>ISSN: 0369-4305</identifier><identifier>EISSN: 1881-4883</identifier><identifier>DOI: 10.6009/jjrt.2022-1132</identifier><identifier>PMID: 35321993</identifier><language>eng ; jpn</language><publisher>Japan: Japanese Society of Radiological Technology</publisher><subject>Angiography ; Aorta ; Arteries ; Body weight ; Cardiac function ; Computed tomography ; Computed Tomography Angiography - methods ; Contrast Media ; contrast medium ; Coronary Angiography - methods ; Coronary artery ; coronary computed tomography angiography (CCTA) ; Correlation ; Echocardiography ; Error correction ; Heart ; Humans ; Injection ; injection condition ; Medical imaging ; Patients ; Stroke volume ; Tomography ; Tomography, X-Ray Computed - methods</subject><ispartof>Japanese Journal of Radiological Technology, 2022, Vol.78(5), pp.484-491</ispartof><rights>2022 Japanese Society of Radiological Technology</rights><rights>Copyright Japan Science and Technology Agency 2022</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2242-1bbdb05d770fd4f6d3eddee3f89e97df2ebc4b4a074f2b6e59200ec83fc9f8e63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35321993$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ogata, Sho</creatorcontrib><creatorcontrib>Nagatomo, Daisuke</creatorcontrib><creatorcontrib>Mizoguchi, Kouji</creatorcontrib><creatorcontrib>Teshima, Toshihiro</creatorcontrib><creatorcontrib>Hotta, Atsushi</creatorcontrib><title>Can Echocardiography Adjust Corrected Contrast Injection Condition in Coronary CT Angiography?</title><title>Japanese Journal of Radiological Technology</title><addtitle>Jpn. J. Radiol. Technol.</addtitle><description>Purpose: The purposes were to search which factor of cardiac function in echocardiography correlates with the CT value, to correct contrast injection conditions with cardiac function in addition to suppress error in the contrast effect between patients, and to achieve the target CT value (350 HU) in coronary computed tomography angiography (CCTA). Methods: In 112 patients (conventional group), the contrast material was administered at a fractional dose (FD) of 21 mgI/kg/s. We measured the aortic CT value in the coronary origin part. In 112 patients (correction group), the contrast material was administered at corrected injection conditions with the most correlated functional factor and CT value. Results: The CT value of the conventional group was an average of 400.8±51.5 HU. The most correlated factor with the CT value was stroke volume [SV (r=−0.555)]. The CT value of the conventional group was an average of 360±46 HU. The case of the aim CT level was improved from 46% to 74%. In the correction group, the average value of FD was 18.5 mgI/kg/s. This enabled the reduction of the contrast material in 95% of patients. Conclusion: The best correlation was obtained between the CT value of coronary arteries and SV. The contrast medium injection conditions were corrected for cardiac function in addition to body weight. As a result, we were able to control the CCTA target CT value of 300 to 400 HU at our hospital.</description><subject>Angiography</subject><subject>Aorta</subject><subject>Arteries</subject><subject>Body weight</subject><subject>Cardiac function</subject><subject>Computed tomography</subject><subject>Computed Tomography Angiography - methods</subject><subject>Contrast Media</subject><subject>contrast medium</subject><subject>Coronary Angiography - methods</subject><subject>Coronary artery</subject><subject>coronary computed tomography angiography (CCTA)</subject><subject>Correlation</subject><subject>Echocardiography</subject><subject>Error correction</subject><subject>Heart</subject><subject>Humans</subject><subject>Injection</subject><subject>injection condition</subject><subject>Medical imaging</subject><subject>Patients</subject><subject>Stroke volume</subject><subject>Tomography</subject><subject>Tomography, X-Ray Computed - methods</subject><issn>0369-4305</issn><issn>1881-4883</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kDFPwzAQhS0EolXpyogiMac4tpPYE6pCgUqVWMqK5djnNlGbFCcZ-u9xSJvFvnv-7vn0EHqM8CLBWLyUpWsXBBMSRhElN2gacR6FjHN6i6aYJiJkFMcTNG-aIsd-wkuY3aMJjSmJhKBT9JOpKljpfa2VM0W9c-q0PwdLU3ZNG2S1c6BbML6qWqe8tK5KrxR11Uum-K-KvnF1pdw5yLbBstpdjV4f0J1Vhwbml3uGvt9X2-wz3Hx9rLPlJtSEML9-npscxyZNsTXMJoaCMQDUcgEiNZZArlnOFE6ZJXkCsSAYg-bUamE5JHSGngffk6t_O2haWdadq_yXkiQpoWlC4tRTi4HSrm4aB1aeXHH0a8sIyz5R2Scq-0Rln6gfeLrYdvkRzIhf8_PA2wCUTat2MALKtYU-wOCXchn3x-g7Puu9chIq-gf38ot2</recordid><startdate>20220101</startdate><enddate>20220101</enddate><creator>Ogata, Sho</creator><creator>Nagatomo, Daisuke</creator><creator>Mizoguchi, Kouji</creator><creator>Teshima, Toshihiro</creator><creator>Hotta, Atsushi</creator><general>Japanese Society of Radiological Technology</general><general>Japan Science and Technology Agency</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>7SC</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope></search><sort><creationdate>20220101</creationdate><title>Can Echocardiography Adjust Corrected Contrast Injection Condition in Coronary CT Angiography?</title><author>Ogata, Sho ; Nagatomo, Daisuke ; Mizoguchi, Kouji ; Teshima, Toshihiro ; Hotta, Atsushi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2242-1bbdb05d770fd4f6d3eddee3f89e97df2ebc4b4a074f2b6e59200ec83fc9f8e63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; jpn</language><creationdate>2022</creationdate><topic>Angiography</topic><topic>Aorta</topic><topic>Arteries</topic><topic>Body weight</topic><topic>Cardiac function</topic><topic>Computed tomography</topic><topic>Computed Tomography Angiography - methods</topic><topic>Contrast Media</topic><topic>contrast medium</topic><topic>Coronary Angiography - methods</topic><topic>Coronary artery</topic><topic>coronary computed tomography angiography (CCTA)</topic><topic>Correlation</topic><topic>Echocardiography</topic><topic>Error correction</topic><topic>Heart</topic><topic>Humans</topic><topic>Injection</topic><topic>injection condition</topic><topic>Medical imaging</topic><topic>Patients</topic><topic>Stroke volume</topic><topic>Tomography</topic><topic>Tomography, X-Ray Computed - methods</topic><toplevel>online_resources</toplevel><creatorcontrib>Ogata, Sho</creatorcontrib><creatorcontrib>Nagatomo, Daisuke</creatorcontrib><creatorcontrib>Mizoguchi, Kouji</creatorcontrib><creatorcontrib>Teshima, Toshihiro</creatorcontrib><creatorcontrib>Hotta, Atsushi</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Japanese Journal of Radiological Technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ogata, Sho</au><au>Nagatomo, Daisuke</au><au>Mizoguchi, Kouji</au><au>Teshima, Toshihiro</au><au>Hotta, Atsushi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Can Echocardiography Adjust Corrected Contrast Injection Condition in Coronary CT Angiography?</atitle><jtitle>Japanese Journal of Radiological Technology</jtitle><addtitle>Jpn. J. Radiol. Technol.</addtitle><date>2022-01-01</date><risdate>2022</risdate><volume>78</volume><issue>5</issue><spage>484</spage><epage>491</epage><pages>484-491</pages><artnum>2022-1132</artnum><issn>0369-4305</issn><eissn>1881-4883</eissn><abstract>Purpose: The purposes were to search which factor of cardiac function in echocardiography correlates with the CT value, to correct contrast injection conditions with cardiac function in addition to suppress error in the contrast effect between patients, and to achieve the target CT value (350 HU) in coronary computed tomography angiography (CCTA). Methods: In 112 patients (conventional group), the contrast material was administered at a fractional dose (FD) of 21 mgI/kg/s. We measured the aortic CT value in the coronary origin part. In 112 patients (correction group), the contrast material was administered at corrected injection conditions with the most correlated functional factor and CT value. Results: The CT value of the conventional group was an average of 400.8±51.5 HU. The most correlated factor with the CT value was stroke volume [SV (r=−0.555)]. The CT value of the conventional group was an average of 360±46 HU. The case of the aim CT level was improved from 46% to 74%. In the correction group, the average value of FD was 18.5 mgI/kg/s. This enabled the reduction of the contrast material in 95% of patients. Conclusion: The best correlation was obtained between the CT value of coronary arteries and SV. The contrast medium injection conditions were corrected for cardiac function in addition to body weight. As a result, we were able to control the CCTA target CT value of 300 to 400 HU at our hospital.</abstract><cop>Japan</cop><pub>Japanese Society of Radiological Technology</pub><pmid>35321993</pmid><doi>10.6009/jjrt.2022-1132</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0369-4305
ispartof Japanese Journal of Radiological Technology, 2022, Vol.78(5), pp.484-491
issn 0369-4305
1881-4883
language eng ; jpn
recordid cdi_proquest_journals_2672376257
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Angiography
Aorta
Arteries
Body weight
Cardiac function
Computed tomography
Computed Tomography Angiography - methods
Contrast Media
contrast medium
Coronary Angiography - methods
Coronary artery
coronary computed tomography angiography (CCTA)
Correlation
Echocardiography
Error correction
Heart
Humans
Injection
injection condition
Medical imaging
Patients
Stroke volume
Tomography
Tomography, X-Ray Computed - methods
title Can Echocardiography Adjust Corrected Contrast Injection Condition in Coronary CT Angiography?
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T06%3A58%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Can%20Echocardiography%20Adjust%20Corrected%20Contrast%20Injection%20Condition%20in%20Coronary%20CT%20Angiography?&rft.jtitle=Japanese%20Journal%20of%20Radiological%20Technology&rft.au=Ogata,%20Sho&rft.date=2022-01-01&rft.volume=78&rft.issue=5&rft.spage=484&rft.epage=491&rft.pages=484-491&rft.artnum=2022-1132&rft.issn=0369-4305&rft.eissn=1881-4883&rft_id=info:doi/10.6009/jjrt.2022-1132&rft_dat=%3Cproquest_cross%3E2672376257%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2672376257&rft_id=info:pmid/35321993&rfr_iscdi=true