Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector

New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as the active scintillating medium and UV-sensitive silicon photomultipliers for scinti...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of instrumentation 2022-05, Vol.17 (5), p.P05044
Hauptverfasser: Renner, J., Romo-Luque, C., Aliaga, R.J., Álvarez, V., Ballester, F., Benlloch-Rodríguez, J.M., Carrión, J.V., Cubero, D., Díaz, J., Esteve, R., Gadea, R., Generowicz, J., Gillam, J., López-Gómez, J.L., Martínez, A., Monrabal, F., Querol, M., Rappaport, M., Rodríguez, J., Rodríguez-Ponce, J., Solevi, P., Teruel-Pardo, S., Toledo, J.F., Torres-Curado, R., Herrero-Bosch, V., Gómez-Cadenas, J.J., Ferrario, P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 5
container_start_page P05044
container_title Journal of instrumentation
container_volume 17
creator Renner, J.
Romo-Luque, C.
Aliaga, R.J.
Álvarez, V.
Ballester, F.
Benlloch-Rodríguez, J.M.
Carrión, J.V.
Cubero, D.
Díaz, J.
Esteve, R.
Gadea, R.
Generowicz, J.
Gillam, J.
López-Gómez, J.L.
Martínez, A.
Monrabal, F.
Querol, M.
Rappaport, M.
Rodríguez, J.
Rodríguez-Ponce, J.
Solevi, P.
Teruel-Pardo, S.
Toledo, J.F.
Torres-Curado, R.
Herrero-Bosch, V.
Gómez-Cadenas, J.J.
Ferrario, P.
description New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as the active scintillating medium and UV-sensitive silicon photomultipliers for scintillation readout. The scintillation time in liquid xenon is fast enough to register time-of-flight information for each detected coincidence, and sufficient scintillation is produced with low enough fluctuations to obtain good energy resolution. The present simulation study examines a full-body-sized PETALO detector and evaluates its potential performance in PET image reconstruction.
doi_str_mv 10.1088/1748-0221/17/05/P05044
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2672023685</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2672023685</sourcerecordid><originalsourceid>FETCH-LOGICAL-c326t-9e3cff472ee93848dca7924c6fb4005456410ac0808e568b6284d8b00ab9f3e53</originalsourceid><addsrcrecordid>eNqFkF9LwzAUxYMoOKdfQQK-WnebJmn6OMb8A5MNnM8hTRPsqM2WpOD89LZU1Def7oF7zrmXH0LXKdylIMQszalIgJC0VzNgsw0woPQETX4Wp3_0OboIYQfACkZhgl6eXRsNXijfOKzflFc6Gl9_qli7FjuLN8vtfLW-xQrbrmmS0lVH3NSHrq7wh2ldm5QqmGqw4cpEo6Pzl-jMqiaYq-85Ra_3y-3iMVmtH54W81WiM8JjUphMW0tzYkyRCSoqrfKCUM1tSfv_KOM0BaVBgDCMi5ITQStRAqiysJlh2RTdjL177w6dCVHuXOfb_qQkPCdAMi4GFx9d2rsQvLFy7-t35Y8yBTkAlAMbObDplQQmR4B9kIzB2u1_m_8JfQEREXCQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2672023685</pqid></control><display><type>article</type><title>Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Renner, J. ; Romo-Luque, C. ; Aliaga, R.J. ; Álvarez, V. ; Ballester, F. ; Benlloch-Rodríguez, J.M. ; Carrión, J.V. ; Cubero, D. ; Díaz, J. ; Esteve, R. ; Gadea, R. ; Generowicz, J. ; Gillam, J. ; López-Gómez, J.L. ; Martínez, A. ; Monrabal, F. ; Querol, M. ; Rappaport, M. ; Rodríguez, J. ; Rodríguez-Ponce, J. ; Solevi, P. ; Teruel-Pardo, S. ; Toledo, J.F. ; Torres-Curado, R. ; Herrero-Bosch, V. ; Gómez-Cadenas, J.J. ; Ferrario, P.</creator><creatorcontrib>Renner, J. ; Romo-Luque, C. ; Aliaga, R.J. ; Álvarez, V. ; Ballester, F. ; Benlloch-Rodríguez, J.M. ; Carrión, J.V. ; Cubero, D. ; Díaz, J. ; Esteve, R. ; Gadea, R. ; Generowicz, J. ; Gillam, J. ; López-Gómez, J.L. ; Martínez, A. ; Monrabal, F. ; Querol, M. ; Rappaport, M. ; Rodríguez, J. ; Rodríguez-Ponce, J. ; Solevi, P. ; Teruel-Pardo, S. ; Toledo, J.F. ; Torres-Curado, R. ; Herrero-Bosch, V. ; Gómez-Cadenas, J.J. ; Ferrario, P.</creatorcontrib><description>New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as the active scintillating medium and UV-sensitive silicon photomultipliers for scintillation readout. The scintillation time in liquid xenon is fast enough to register time-of-flight information for each detected coincidence, and sufficient scintillation is produced with low enough fluctuations to obtain good energy resolution. The present simulation study examines a full-body-sized PETALO detector and evaluates its potential performance in PET image reconstruction.</description><identifier>ISSN: 1748-0221</identifier><identifier>EISSN: 1748-0221</identifier><identifier>DOI: 10.1088/1748-0221/17/05/P05044</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Cryogenic detectors ; Energy resolution ; Gamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA) ; Image reconstruction ; Liquid detectors ; Photomultiplier tubes ; Positron emission ; Radiation dosage ; Scintillation ; Sensors ; Tomography ; Xenon</subject><ispartof>Journal of instrumentation, 2022-05, Vol.17 (5), p.P05044</ispartof><rights>2022 IOP Publishing Ltd and Sissa Medialab</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c326t-9e3cff472ee93848dca7924c6fb4005456410ac0808e568b6284d8b00ab9f3e53</citedby><cites>FETCH-LOGICAL-c326t-9e3cff472ee93848dca7924c6fb4005456410ac0808e568b6284d8b00ab9f3e53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1748-0221/17/05/P05044/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,776,780,27901,27902,53821,53868</link.rule.ids></links><search><creatorcontrib>Renner, J.</creatorcontrib><creatorcontrib>Romo-Luque, C.</creatorcontrib><creatorcontrib>Aliaga, R.J.</creatorcontrib><creatorcontrib>Álvarez, V.</creatorcontrib><creatorcontrib>Ballester, F.</creatorcontrib><creatorcontrib>Benlloch-Rodríguez, J.M.</creatorcontrib><creatorcontrib>Carrión, J.V.</creatorcontrib><creatorcontrib>Cubero, D.</creatorcontrib><creatorcontrib>Díaz, J.</creatorcontrib><creatorcontrib>Esteve, R.</creatorcontrib><creatorcontrib>Gadea, R.</creatorcontrib><creatorcontrib>Generowicz, J.</creatorcontrib><creatorcontrib>Gillam, J.</creatorcontrib><creatorcontrib>López-Gómez, J.L.</creatorcontrib><creatorcontrib>Martínez, A.</creatorcontrib><creatorcontrib>Monrabal, F.</creatorcontrib><creatorcontrib>Querol, M.</creatorcontrib><creatorcontrib>Rappaport, M.</creatorcontrib><creatorcontrib>Rodríguez, J.</creatorcontrib><creatorcontrib>Rodríguez-Ponce, J.</creatorcontrib><creatorcontrib>Solevi, P.</creatorcontrib><creatorcontrib>Teruel-Pardo, S.</creatorcontrib><creatorcontrib>Toledo, J.F.</creatorcontrib><creatorcontrib>Torres-Curado, R.</creatorcontrib><creatorcontrib>Herrero-Bosch, V.</creatorcontrib><creatorcontrib>Gómez-Cadenas, J.J.</creatorcontrib><creatorcontrib>Ferrario, P.</creatorcontrib><title>Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector</title><title>Journal of instrumentation</title><addtitle>J. Instrum</addtitle><description>New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as the active scintillating medium and UV-sensitive silicon photomultipliers for scintillation readout. The scintillation time in liquid xenon is fast enough to register time-of-flight information for each detected coincidence, and sufficient scintillation is produced with low enough fluctuations to obtain good energy resolution. The present simulation study examines a full-body-sized PETALO detector and evaluates its potential performance in PET image reconstruction.</description><subject>Cryogenic detectors</subject><subject>Energy resolution</subject><subject>Gamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA)</subject><subject>Image reconstruction</subject><subject>Liquid detectors</subject><subject>Photomultiplier tubes</subject><subject>Positron emission</subject><subject>Radiation dosage</subject><subject>Scintillation</subject><subject>Sensors</subject><subject>Tomography</subject><subject>Xenon</subject><issn>1748-0221</issn><issn>1748-0221</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNqFkF9LwzAUxYMoOKdfQQK-WnebJmn6OMb8A5MNnM8hTRPsqM2WpOD89LZU1Def7oF7zrmXH0LXKdylIMQszalIgJC0VzNgsw0woPQETX4Wp3_0OboIYQfACkZhgl6eXRsNXijfOKzflFc6Gl9_qli7FjuLN8vtfLW-xQrbrmmS0lVH3NSHrq7wh2ldm5QqmGqw4cpEo6Pzl-jMqiaYq-85Ra_3y-3iMVmtH54W81WiM8JjUphMW0tzYkyRCSoqrfKCUM1tSfv_KOM0BaVBgDCMi5ITQStRAqiysJlh2RTdjL177w6dCVHuXOfb_qQkPCdAMi4GFx9d2rsQvLFy7-t35Y8yBTkAlAMbObDplQQmR4B9kIzB2u1_m_8JfQEREXCQ</recordid><startdate>20220501</startdate><enddate>20220501</enddate><creator>Renner, J.</creator><creator>Romo-Luque, C.</creator><creator>Aliaga, R.J.</creator><creator>Álvarez, V.</creator><creator>Ballester, F.</creator><creator>Benlloch-Rodríguez, J.M.</creator><creator>Carrión, J.V.</creator><creator>Cubero, D.</creator><creator>Díaz, J.</creator><creator>Esteve, R.</creator><creator>Gadea, R.</creator><creator>Generowicz, J.</creator><creator>Gillam, J.</creator><creator>López-Gómez, J.L.</creator><creator>Martínez, A.</creator><creator>Monrabal, F.</creator><creator>Querol, M.</creator><creator>Rappaport, M.</creator><creator>Rodríguez, J.</creator><creator>Rodríguez-Ponce, J.</creator><creator>Solevi, P.</creator><creator>Teruel-Pardo, S.</creator><creator>Toledo, J.F.</creator><creator>Torres-Curado, R.</creator><creator>Herrero-Bosch, V.</creator><creator>Gómez-Cadenas, J.J.</creator><creator>Ferrario, P.</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20220501</creationdate><title>Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector</title><author>Renner, J. ; Romo-Luque, C. ; Aliaga, R.J. ; Álvarez, V. ; Ballester, F. ; Benlloch-Rodríguez, J.M. ; Carrión, J.V. ; Cubero, D. ; Díaz, J. ; Esteve, R. ; Gadea, R. ; Generowicz, J. ; Gillam, J. ; López-Gómez, J.L. ; Martínez, A. ; Monrabal, F. ; Querol, M. ; Rappaport, M. ; Rodríguez, J. ; Rodríguez-Ponce, J. ; Solevi, P. ; Teruel-Pardo, S. ; Toledo, J.F. ; Torres-Curado, R. ; Herrero-Bosch, V. ; Gómez-Cadenas, J.J. ; Ferrario, P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c326t-9e3cff472ee93848dca7924c6fb4005456410ac0808e568b6284d8b00ab9f3e53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Cryogenic detectors</topic><topic>Energy resolution</topic><topic>Gamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA)</topic><topic>Image reconstruction</topic><topic>Liquid detectors</topic><topic>Photomultiplier tubes</topic><topic>Positron emission</topic><topic>Radiation dosage</topic><topic>Scintillation</topic><topic>Sensors</topic><topic>Tomography</topic><topic>Xenon</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Renner, J.</creatorcontrib><creatorcontrib>Romo-Luque, C.</creatorcontrib><creatorcontrib>Aliaga, R.J.</creatorcontrib><creatorcontrib>Álvarez, V.</creatorcontrib><creatorcontrib>Ballester, F.</creatorcontrib><creatorcontrib>Benlloch-Rodríguez, J.M.</creatorcontrib><creatorcontrib>Carrión, J.V.</creatorcontrib><creatorcontrib>Cubero, D.</creatorcontrib><creatorcontrib>Díaz, J.</creatorcontrib><creatorcontrib>Esteve, R.</creatorcontrib><creatorcontrib>Gadea, R.</creatorcontrib><creatorcontrib>Generowicz, J.</creatorcontrib><creatorcontrib>Gillam, J.</creatorcontrib><creatorcontrib>López-Gómez, J.L.</creatorcontrib><creatorcontrib>Martínez, A.</creatorcontrib><creatorcontrib>Monrabal, F.</creatorcontrib><creatorcontrib>Querol, M.</creatorcontrib><creatorcontrib>Rappaport, M.</creatorcontrib><creatorcontrib>Rodríguez, J.</creatorcontrib><creatorcontrib>Rodríguez-Ponce, J.</creatorcontrib><creatorcontrib>Solevi, P.</creatorcontrib><creatorcontrib>Teruel-Pardo, S.</creatorcontrib><creatorcontrib>Toledo, J.F.</creatorcontrib><creatorcontrib>Torres-Curado, R.</creatorcontrib><creatorcontrib>Herrero-Bosch, V.</creatorcontrib><creatorcontrib>Gómez-Cadenas, J.J.</creatorcontrib><creatorcontrib>Ferrario, P.</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of instrumentation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Renner, J.</au><au>Romo-Luque, C.</au><au>Aliaga, R.J.</au><au>Álvarez, V.</au><au>Ballester, F.</au><au>Benlloch-Rodríguez, J.M.</au><au>Carrión, J.V.</au><au>Cubero, D.</au><au>Díaz, J.</au><au>Esteve, R.</au><au>Gadea, R.</au><au>Generowicz, J.</au><au>Gillam, J.</au><au>López-Gómez, J.L.</au><au>Martínez, A.</au><au>Monrabal, F.</au><au>Querol, M.</au><au>Rappaport, M.</au><au>Rodríguez, J.</au><au>Rodríguez-Ponce, J.</au><au>Solevi, P.</au><au>Teruel-Pardo, S.</au><au>Toledo, J.F.</au><au>Torres-Curado, R.</au><au>Herrero-Bosch, V.</au><au>Gómez-Cadenas, J.J.</au><au>Ferrario, P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector</atitle><jtitle>Journal of instrumentation</jtitle><addtitle>J. Instrum</addtitle><date>2022-05-01</date><risdate>2022</risdate><volume>17</volume><issue>5</issue><spage>P05044</spage><pages>P05044-</pages><issn>1748-0221</issn><eissn>1748-0221</eissn><abstract>New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as the active scintillating medium and UV-sensitive silicon photomultipliers for scintillation readout. The scintillation time in liquid xenon is fast enough to register time-of-flight information for each detected coincidence, and sufficient scintillation is produced with low enough fluctuations to obtain good energy resolution. The present simulation study examines a full-body-sized PETALO detector and evaluates its potential performance in PET image reconstruction.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1748-0221/17/05/P05044</doi><tpages>16</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1748-0221
ispartof Journal of instrumentation, 2022-05, Vol.17 (5), p.P05044
issn 1748-0221
1748-0221
language eng
recordid cdi_proquest_journals_2672023685
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects Cryogenic detectors
Energy resolution
Gamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA)
Image reconstruction
Liquid detectors
Photomultiplier tubes
Positron emission
Radiation dosage
Scintillation
Sensors
Tomography
Xenon
title Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T00%3A00%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Monte%20Carlo%20characterization%20of%20PETALO,%20a%20full-body%20liquid%20xenon-based%20PET%20detector&rft.jtitle=Journal%20of%20instrumentation&rft.au=Renner,%20J.&rft.date=2022-05-01&rft.volume=17&rft.issue=5&rft.spage=P05044&rft.pages=P05044-&rft.issn=1748-0221&rft.eissn=1748-0221&rft_id=info:doi/10.1088/1748-0221/17/05/P05044&rft_dat=%3Cproquest_cross%3E2672023685%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2672023685&rft_id=info:pmid/&rfr_iscdi=true