Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector
New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as the active scintillating medium and UV-sensitive silicon photomultipliers for scinti...
Gespeichert in:
Veröffentlicht in: | Journal of instrumentation 2022-05, Vol.17 (5), p.P05044 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 5 |
container_start_page | P05044 |
container_title | Journal of instrumentation |
container_volume | 17 |
creator | Renner, J. Romo-Luque, C. Aliaga, R.J. Álvarez, V. Ballester, F. Benlloch-Rodríguez, J.M. Carrión, J.V. Cubero, D. Díaz, J. Esteve, R. Gadea, R. Generowicz, J. Gillam, J. López-Gómez, J.L. Martínez, A. Monrabal, F. Querol, M. Rappaport, M. Rodríguez, J. Rodríguez-Ponce, J. Solevi, P. Teruel-Pardo, S. Toledo, J.F. Torres-Curado, R. Herrero-Bosch, V. Gómez-Cadenas, J.J. Ferrario, P. |
description | New detector approaches in Positron Emission Tomography
imaging will play an important role in reducing costs, lowering
administered radiation doses, and improving overall
performance. PETALO employs liquid xenon as the active scintillating
medium and UV-sensitive silicon photomultipliers for scintillation
readout. The scintillation time in liquid xenon is fast enough to
register time-of-flight information for each detected coincidence,
and sufficient scintillation is produced with low enough
fluctuations to obtain good energy resolution. The present
simulation study examines a full-body-sized PETALO detector and
evaluates its potential performance in PET image reconstruction. |
doi_str_mv | 10.1088/1748-0221/17/05/P05044 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2672023685</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2672023685</sourcerecordid><originalsourceid>FETCH-LOGICAL-c326t-9e3cff472ee93848dca7924c6fb4005456410ac0808e568b6284d8b00ab9f3e53</originalsourceid><addsrcrecordid>eNqFkF9LwzAUxYMoOKdfQQK-WnebJmn6OMb8A5MNnM8hTRPsqM2WpOD89LZU1Def7oF7zrmXH0LXKdylIMQszalIgJC0VzNgsw0woPQETX4Wp3_0OboIYQfACkZhgl6eXRsNXijfOKzflFc6Gl9_qli7FjuLN8vtfLW-xQrbrmmS0lVH3NSHrq7wh2ldm5QqmGqw4cpEo6Pzl-jMqiaYq-85Ra_3y-3iMVmtH54W81WiM8JjUphMW0tzYkyRCSoqrfKCUM1tSfv_KOM0BaVBgDCMi5ITQStRAqiysJlh2RTdjL177w6dCVHuXOfb_qQkPCdAMi4GFx9d2rsQvLFy7-t35Y8yBTkAlAMbObDplQQmR4B9kIzB2u1_m_8JfQEREXCQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2672023685</pqid></control><display><type>article</type><title>Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Renner, J. ; Romo-Luque, C. ; Aliaga, R.J. ; Álvarez, V. ; Ballester, F. ; Benlloch-Rodríguez, J.M. ; Carrión, J.V. ; Cubero, D. ; Díaz, J. ; Esteve, R. ; Gadea, R. ; Generowicz, J. ; Gillam, J. ; López-Gómez, J.L. ; Martínez, A. ; Monrabal, F. ; Querol, M. ; Rappaport, M. ; Rodríguez, J. ; Rodríguez-Ponce, J. ; Solevi, P. ; Teruel-Pardo, S. ; Toledo, J.F. ; Torres-Curado, R. ; Herrero-Bosch, V. ; Gómez-Cadenas, J.J. ; Ferrario, P.</creator><creatorcontrib>Renner, J. ; Romo-Luque, C. ; Aliaga, R.J. ; Álvarez, V. ; Ballester, F. ; Benlloch-Rodríguez, J.M. ; Carrión, J.V. ; Cubero, D. ; Díaz, J. ; Esteve, R. ; Gadea, R. ; Generowicz, J. ; Gillam, J. ; López-Gómez, J.L. ; Martínez, A. ; Monrabal, F. ; Querol, M. ; Rappaport, M. ; Rodríguez, J. ; Rodríguez-Ponce, J. ; Solevi, P. ; Teruel-Pardo, S. ; Toledo, J.F. ; Torres-Curado, R. ; Herrero-Bosch, V. ; Gómez-Cadenas, J.J. ; Ferrario, P.</creatorcontrib><description>New detector approaches in Positron Emission Tomography
imaging will play an important role in reducing costs, lowering
administered radiation doses, and improving overall
performance. PETALO employs liquid xenon as the active scintillating
medium and UV-sensitive silicon photomultipliers for scintillation
readout. The scintillation time in liquid xenon is fast enough to
register time-of-flight information for each detected coincidence,
and sufficient scintillation is produced with low enough
fluctuations to obtain good energy resolution. The present
simulation study examines a full-body-sized PETALO detector and
evaluates its potential performance in PET image reconstruction.</description><identifier>ISSN: 1748-0221</identifier><identifier>EISSN: 1748-0221</identifier><identifier>DOI: 10.1088/1748-0221/17/05/P05044</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Cryogenic detectors ; Energy resolution ; Gamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA) ; Image reconstruction ; Liquid detectors ; Photomultiplier tubes ; Positron emission ; Radiation dosage ; Scintillation ; Sensors ; Tomography ; Xenon</subject><ispartof>Journal of instrumentation, 2022-05, Vol.17 (5), p.P05044</ispartof><rights>2022 IOP Publishing Ltd and Sissa Medialab</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c326t-9e3cff472ee93848dca7924c6fb4005456410ac0808e568b6284d8b00ab9f3e53</citedby><cites>FETCH-LOGICAL-c326t-9e3cff472ee93848dca7924c6fb4005456410ac0808e568b6284d8b00ab9f3e53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1748-0221/17/05/P05044/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,776,780,27901,27902,53821,53868</link.rule.ids></links><search><creatorcontrib>Renner, J.</creatorcontrib><creatorcontrib>Romo-Luque, C.</creatorcontrib><creatorcontrib>Aliaga, R.J.</creatorcontrib><creatorcontrib>Álvarez, V.</creatorcontrib><creatorcontrib>Ballester, F.</creatorcontrib><creatorcontrib>Benlloch-Rodríguez, J.M.</creatorcontrib><creatorcontrib>Carrión, J.V.</creatorcontrib><creatorcontrib>Cubero, D.</creatorcontrib><creatorcontrib>Díaz, J.</creatorcontrib><creatorcontrib>Esteve, R.</creatorcontrib><creatorcontrib>Gadea, R.</creatorcontrib><creatorcontrib>Generowicz, J.</creatorcontrib><creatorcontrib>Gillam, J.</creatorcontrib><creatorcontrib>López-Gómez, J.L.</creatorcontrib><creatorcontrib>Martínez, A.</creatorcontrib><creatorcontrib>Monrabal, F.</creatorcontrib><creatorcontrib>Querol, M.</creatorcontrib><creatorcontrib>Rappaport, M.</creatorcontrib><creatorcontrib>Rodríguez, J.</creatorcontrib><creatorcontrib>Rodríguez-Ponce, J.</creatorcontrib><creatorcontrib>Solevi, P.</creatorcontrib><creatorcontrib>Teruel-Pardo, S.</creatorcontrib><creatorcontrib>Toledo, J.F.</creatorcontrib><creatorcontrib>Torres-Curado, R.</creatorcontrib><creatorcontrib>Herrero-Bosch, V.</creatorcontrib><creatorcontrib>Gómez-Cadenas, J.J.</creatorcontrib><creatorcontrib>Ferrario, P.</creatorcontrib><title>Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector</title><title>Journal of instrumentation</title><addtitle>J. Instrum</addtitle><description>New detector approaches in Positron Emission Tomography
imaging will play an important role in reducing costs, lowering
administered radiation doses, and improving overall
performance. PETALO employs liquid xenon as the active scintillating
medium and UV-sensitive silicon photomultipliers for scintillation
readout. The scintillation time in liquid xenon is fast enough to
register time-of-flight information for each detected coincidence,
and sufficient scintillation is produced with low enough
fluctuations to obtain good energy resolution. The present
simulation study examines a full-body-sized PETALO detector and
evaluates its potential performance in PET image reconstruction.</description><subject>Cryogenic detectors</subject><subject>Energy resolution</subject><subject>Gamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA)</subject><subject>Image reconstruction</subject><subject>Liquid detectors</subject><subject>Photomultiplier tubes</subject><subject>Positron emission</subject><subject>Radiation dosage</subject><subject>Scintillation</subject><subject>Sensors</subject><subject>Tomography</subject><subject>Xenon</subject><issn>1748-0221</issn><issn>1748-0221</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNqFkF9LwzAUxYMoOKdfQQK-WnebJmn6OMb8A5MNnM8hTRPsqM2WpOD89LZU1Def7oF7zrmXH0LXKdylIMQszalIgJC0VzNgsw0woPQETX4Wp3_0OboIYQfACkZhgl6eXRsNXijfOKzflFc6Gl9_qli7FjuLN8vtfLW-xQrbrmmS0lVH3NSHrq7wh2ldm5QqmGqw4cpEo6Pzl-jMqiaYq-85Ra_3y-3iMVmtH54W81WiM8JjUphMW0tzYkyRCSoqrfKCUM1tSfv_KOM0BaVBgDCMi5ITQStRAqiysJlh2RTdjL177w6dCVHuXOfb_qQkPCdAMi4GFx9d2rsQvLFy7-t35Y8yBTkAlAMbObDplQQmR4B9kIzB2u1_m_8JfQEREXCQ</recordid><startdate>20220501</startdate><enddate>20220501</enddate><creator>Renner, J.</creator><creator>Romo-Luque, C.</creator><creator>Aliaga, R.J.</creator><creator>Álvarez, V.</creator><creator>Ballester, F.</creator><creator>Benlloch-Rodríguez, J.M.</creator><creator>Carrión, J.V.</creator><creator>Cubero, D.</creator><creator>Díaz, J.</creator><creator>Esteve, R.</creator><creator>Gadea, R.</creator><creator>Generowicz, J.</creator><creator>Gillam, J.</creator><creator>López-Gómez, J.L.</creator><creator>Martínez, A.</creator><creator>Monrabal, F.</creator><creator>Querol, M.</creator><creator>Rappaport, M.</creator><creator>Rodríguez, J.</creator><creator>Rodríguez-Ponce, J.</creator><creator>Solevi, P.</creator><creator>Teruel-Pardo, S.</creator><creator>Toledo, J.F.</creator><creator>Torres-Curado, R.</creator><creator>Herrero-Bosch, V.</creator><creator>Gómez-Cadenas, J.J.</creator><creator>Ferrario, P.</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20220501</creationdate><title>Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector</title><author>Renner, J. ; Romo-Luque, C. ; Aliaga, R.J. ; Álvarez, V. ; Ballester, F. ; Benlloch-Rodríguez, J.M. ; Carrión, J.V. ; Cubero, D. ; Díaz, J. ; Esteve, R. ; Gadea, R. ; Generowicz, J. ; Gillam, J. ; López-Gómez, J.L. ; Martínez, A. ; Monrabal, F. ; Querol, M. ; Rappaport, M. ; Rodríguez, J. ; Rodríguez-Ponce, J. ; Solevi, P. ; Teruel-Pardo, S. ; Toledo, J.F. ; Torres-Curado, R. ; Herrero-Bosch, V. ; Gómez-Cadenas, J.J. ; Ferrario, P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c326t-9e3cff472ee93848dca7924c6fb4005456410ac0808e568b6284d8b00ab9f3e53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Cryogenic detectors</topic><topic>Energy resolution</topic><topic>Gamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA)</topic><topic>Image reconstruction</topic><topic>Liquid detectors</topic><topic>Photomultiplier tubes</topic><topic>Positron emission</topic><topic>Radiation dosage</topic><topic>Scintillation</topic><topic>Sensors</topic><topic>Tomography</topic><topic>Xenon</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Renner, J.</creatorcontrib><creatorcontrib>Romo-Luque, C.</creatorcontrib><creatorcontrib>Aliaga, R.J.</creatorcontrib><creatorcontrib>Álvarez, V.</creatorcontrib><creatorcontrib>Ballester, F.</creatorcontrib><creatorcontrib>Benlloch-Rodríguez, J.M.</creatorcontrib><creatorcontrib>Carrión, J.V.</creatorcontrib><creatorcontrib>Cubero, D.</creatorcontrib><creatorcontrib>Díaz, J.</creatorcontrib><creatorcontrib>Esteve, R.</creatorcontrib><creatorcontrib>Gadea, R.</creatorcontrib><creatorcontrib>Generowicz, J.</creatorcontrib><creatorcontrib>Gillam, J.</creatorcontrib><creatorcontrib>López-Gómez, J.L.</creatorcontrib><creatorcontrib>Martínez, A.</creatorcontrib><creatorcontrib>Monrabal, F.</creatorcontrib><creatorcontrib>Querol, M.</creatorcontrib><creatorcontrib>Rappaport, M.</creatorcontrib><creatorcontrib>Rodríguez, J.</creatorcontrib><creatorcontrib>Rodríguez-Ponce, J.</creatorcontrib><creatorcontrib>Solevi, P.</creatorcontrib><creatorcontrib>Teruel-Pardo, S.</creatorcontrib><creatorcontrib>Toledo, J.F.</creatorcontrib><creatorcontrib>Torres-Curado, R.</creatorcontrib><creatorcontrib>Herrero-Bosch, V.</creatorcontrib><creatorcontrib>Gómez-Cadenas, J.J.</creatorcontrib><creatorcontrib>Ferrario, P.</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of instrumentation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Renner, J.</au><au>Romo-Luque, C.</au><au>Aliaga, R.J.</au><au>Álvarez, V.</au><au>Ballester, F.</au><au>Benlloch-Rodríguez, J.M.</au><au>Carrión, J.V.</au><au>Cubero, D.</au><au>Díaz, J.</au><au>Esteve, R.</au><au>Gadea, R.</au><au>Generowicz, J.</au><au>Gillam, J.</au><au>López-Gómez, J.L.</au><au>Martínez, A.</au><au>Monrabal, F.</au><au>Querol, M.</au><au>Rappaport, M.</au><au>Rodríguez, J.</au><au>Rodríguez-Ponce, J.</au><au>Solevi, P.</au><au>Teruel-Pardo, S.</au><au>Toledo, J.F.</au><au>Torres-Curado, R.</au><au>Herrero-Bosch, V.</au><au>Gómez-Cadenas, J.J.</au><au>Ferrario, P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector</atitle><jtitle>Journal of instrumentation</jtitle><addtitle>J. Instrum</addtitle><date>2022-05-01</date><risdate>2022</risdate><volume>17</volume><issue>5</issue><spage>P05044</spage><pages>P05044-</pages><issn>1748-0221</issn><eissn>1748-0221</eissn><abstract>New detector approaches in Positron Emission Tomography
imaging will play an important role in reducing costs, lowering
administered radiation doses, and improving overall
performance. PETALO employs liquid xenon as the active scintillating
medium and UV-sensitive silicon photomultipliers for scintillation
readout. The scintillation time in liquid xenon is fast enough to
register time-of-flight information for each detected coincidence,
and sufficient scintillation is produced with low enough
fluctuations to obtain good energy resolution. The present
simulation study examines a full-body-sized PETALO detector and
evaluates its potential performance in PET image reconstruction.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1748-0221/17/05/P05044</doi><tpages>16</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1748-0221 |
ispartof | Journal of instrumentation, 2022-05, Vol.17 (5), p.P05044 |
issn | 1748-0221 1748-0221 |
language | eng |
recordid | cdi_proquest_journals_2672023685 |
source | IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link |
subjects | Cryogenic detectors Energy resolution Gamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA) Image reconstruction Liquid detectors Photomultiplier tubes Positron emission Radiation dosage Scintillation Sensors Tomography Xenon |
title | Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T00%3A00%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Monte%20Carlo%20characterization%20of%20PETALO,%20a%20full-body%20liquid%20xenon-based%20PET%20detector&rft.jtitle=Journal%20of%20instrumentation&rft.au=Renner,%20J.&rft.date=2022-05-01&rft.volume=17&rft.issue=5&rft.spage=P05044&rft.pages=P05044-&rft.issn=1748-0221&rft.eissn=1748-0221&rft_id=info:doi/10.1088/1748-0221/17/05/P05044&rft_dat=%3Cproquest_cross%3E2672023685%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2672023685&rft_id=info:pmid/&rfr_iscdi=true |