The Development of Gas-flow Modulation for High-frequency MTDSC measurements

The purpose of this study was to investigate the feasibility of modulating the temperature programme of a conventional DSC by use of an alternating gas-flow system. Modulated temperature differential scanning calorimetry (MTDSC) is an important thermal analysis technique but suffers from a limited a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of thermal analysis and calorimetry 2000-01, Vol.60 (3), p.795-805
Hauptverfasser: Royall, P G, Craig D Q M, Reading, M, Lever, T J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 805
container_issue 3
container_start_page 795
container_title Journal of thermal analysis and calorimetry
container_volume 60
creator Royall, P G
Craig D Q M
Reading, M
Lever, T J
description The purpose of this study was to investigate the feasibility of modulating the temperature programme of a conventional DSC by use of an alternating gas-flow system. Modulated temperature differential scanning calorimetry (MTDSC) is an important thermal analysis technique but suffers from a limited applicable frequency range due to the mass of the sample and DSC cell leading to the impingement of thermal conductivity effects. We suggest that the frequency limit can be increased by replacing the cell as the source of temperature modulation with an external gaseous source, directed towards the sample and reference pans. In this evaluation, an alternating gas-flow was passed through a line to a forced gas-flow accessory (FGFA). The FGFA consisted of two matched cylinders containing chambers that allowed pre-temperature-equilibration of the stream of gas before it was passed over the sample and reference pans. The development of this device revealed the essential practical requirements of gas-flow modulation for high-frequency temperature modulation. These include the following: an appropriately sealed tunable gas supply to both sample and reference pans, an effective method for high-frequency cycling of the gas-flow rate, a small aperture to deliver the flowing gas directly over the pan and a temperature equilibration chamber. The results from samples of quenched PET and amorphous Saquinavir indicate that gas-flow modulation is indeed feasible, with the FGFA able to raise the attainable temperature modulation frequency by an order of magnitude compared to conventional MTDSC.
doi_str_mv 10.1023/A:1010143304958
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2664061650</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2664061650</sourcerecordid><originalsourceid>FETCH-LOGICAL-p181t-1b6f20e3f8867d54c2c60954189a122a08382b83c336b2cca0d3d6cde8b589a63</originalsourceid><addsrcrecordid>eNotTj1PwzAUtBBIlMLMaonZ8GzHD5utSqFFSsVAmCvHsWmrNA5xAuLfEwS64W64L0KuOdxyEPJu8cBhQiYlZEbpEzLjSmsmjMDTSctJI1dwTi5SOgCAMcBnpCh3ni79p29id_TtQGOgK5tYaOIX3cR6bOywjy0Nsafr_fuOhd5_jL5133RTLl9zevQ2jb3_zaZLchZsk_zVP8_J29Njma9Z8bJ6zhcF67jmA-MVBgFeBq3xvlaZEw7BqIxrY7kQFrTUotLSSYmVcM5CLWt0tdeVmiwo5-Tmr7fr43QmDdtDHPt2mtwKxAyQowL5A1jWTnU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2664061650</pqid></control><display><type>article</type><title>The Development of Gas-flow Modulation for High-frequency MTDSC measurements</title><source>SpringerLink Journals - AutoHoldings</source><creator>Royall, P G ; Craig D Q M ; Reading, M ; Lever, T J</creator><creatorcontrib>Royall, P G ; Craig D Q M ; Reading, M ; Lever, T J</creatorcontrib><description>The purpose of this study was to investigate the feasibility of modulating the temperature programme of a conventional DSC by use of an alternating gas-flow system. Modulated temperature differential scanning calorimetry (MTDSC) is an important thermal analysis technique but suffers from a limited applicable frequency range due to the mass of the sample and DSC cell leading to the impingement of thermal conductivity effects. We suggest that the frequency limit can be increased by replacing the cell as the source of temperature modulation with an external gaseous source, directed towards the sample and reference pans. In this evaluation, an alternating gas-flow was passed through a line to a forced gas-flow accessory (FGFA). The FGFA consisted of two matched cylinders containing chambers that allowed pre-temperature-equilibration of the stream of gas before it was passed over the sample and reference pans. The development of this device revealed the essential practical requirements of gas-flow modulation for high-frequency temperature modulation. These include the following: an appropriately sealed tunable gas supply to both sample and reference pans, an effective method for high-frequency cycling of the gas-flow rate, a small aperture to deliver the flowing gas directly over the pan and a temperature equilibration chamber. The results from samples of quenched PET and amorphous Saquinavir indicate that gas-flow modulation is indeed feasible, with the FGFA able to raise the attainable temperature modulation frequency by an order of magnitude compared to conventional MTDSC.</description><identifier>ISSN: 1388-6150</identifier><identifier>EISSN: 1588-2926</identifier><identifier>DOI: 10.1023/A:1010143304958</identifier><language>eng</language><publisher>Dordrecht: Springer Nature B.V</publisher><subject>Balancing ; Cylindrical chambers ; Differential scanning calorimetry ; Feasibility ; Flow velocity ; Frequency ranges ; Gas flow ; Modulation ; Thermal conductivity</subject><ispartof>Journal of thermal analysis and calorimetry, 2000-01, Vol.60 (3), p.795-805</ispartof><rights>Kluwer Academic Publishers 2000.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>Royall, P G</creatorcontrib><creatorcontrib>Craig D Q M</creatorcontrib><creatorcontrib>Reading, M</creatorcontrib><creatorcontrib>Lever, T J</creatorcontrib><title>The Development of Gas-flow Modulation for High-frequency MTDSC measurements</title><title>Journal of thermal analysis and calorimetry</title><description>The purpose of this study was to investigate the feasibility of modulating the temperature programme of a conventional DSC by use of an alternating gas-flow system. Modulated temperature differential scanning calorimetry (MTDSC) is an important thermal analysis technique but suffers from a limited applicable frequency range due to the mass of the sample and DSC cell leading to the impingement of thermal conductivity effects. We suggest that the frequency limit can be increased by replacing the cell as the source of temperature modulation with an external gaseous source, directed towards the sample and reference pans. In this evaluation, an alternating gas-flow was passed through a line to a forced gas-flow accessory (FGFA). The FGFA consisted of two matched cylinders containing chambers that allowed pre-temperature-equilibration of the stream of gas before it was passed over the sample and reference pans. The development of this device revealed the essential practical requirements of gas-flow modulation for high-frequency temperature modulation. These include the following: an appropriately sealed tunable gas supply to both sample and reference pans, an effective method for high-frequency cycling of the gas-flow rate, a small aperture to deliver the flowing gas directly over the pan and a temperature equilibration chamber. The results from samples of quenched PET and amorphous Saquinavir indicate that gas-flow modulation is indeed feasible, with the FGFA able to raise the attainable temperature modulation frequency by an order of magnitude compared to conventional MTDSC.</description><subject>Balancing</subject><subject>Cylindrical chambers</subject><subject>Differential scanning calorimetry</subject><subject>Feasibility</subject><subject>Flow velocity</subject><subject>Frequency ranges</subject><subject>Gas flow</subject><subject>Modulation</subject><subject>Thermal conductivity</subject><issn>1388-6150</issn><issn>1588-2926</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNotTj1PwzAUtBBIlMLMaonZ8GzHD5utSqFFSsVAmCvHsWmrNA5xAuLfEwS64W64L0KuOdxyEPJu8cBhQiYlZEbpEzLjSmsmjMDTSctJI1dwTi5SOgCAMcBnpCh3ni79p29id_TtQGOgK5tYaOIX3cR6bOywjy0Nsafr_fuOhd5_jL5133RTLl9zevQ2jb3_zaZLchZsk_zVP8_J29Njma9Z8bJ6zhcF67jmA-MVBgFeBq3xvlaZEw7BqIxrY7kQFrTUotLSSYmVcM5CLWt0tdeVmiwo5-Tmr7fr43QmDdtDHPt2mtwKxAyQowL5A1jWTnU</recordid><startdate>20000101</startdate><enddate>20000101</enddate><creator>Royall, P G</creator><creator>Craig D Q M</creator><creator>Reading, M</creator><creator>Lever, T J</creator><general>Springer Nature B.V</general><scope/></search><sort><creationdate>20000101</creationdate><title>The Development of Gas-flow Modulation for High-frequency MTDSC measurements</title><author>Royall, P G ; Craig D Q M ; Reading, M ; Lever, T J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p181t-1b6f20e3f8867d54c2c60954189a122a08382b83c336b2cca0d3d6cde8b589a63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Balancing</topic><topic>Cylindrical chambers</topic><topic>Differential scanning calorimetry</topic><topic>Feasibility</topic><topic>Flow velocity</topic><topic>Frequency ranges</topic><topic>Gas flow</topic><topic>Modulation</topic><topic>Thermal conductivity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Royall, P G</creatorcontrib><creatorcontrib>Craig D Q M</creatorcontrib><creatorcontrib>Reading, M</creatorcontrib><creatorcontrib>Lever, T J</creatorcontrib><jtitle>Journal of thermal analysis and calorimetry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Royall, P G</au><au>Craig D Q M</au><au>Reading, M</au><au>Lever, T J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Development of Gas-flow Modulation for High-frequency MTDSC measurements</atitle><jtitle>Journal of thermal analysis and calorimetry</jtitle><date>2000-01-01</date><risdate>2000</risdate><volume>60</volume><issue>3</issue><spage>795</spage><epage>805</epage><pages>795-805</pages><issn>1388-6150</issn><eissn>1588-2926</eissn><abstract>The purpose of this study was to investigate the feasibility of modulating the temperature programme of a conventional DSC by use of an alternating gas-flow system. Modulated temperature differential scanning calorimetry (MTDSC) is an important thermal analysis technique but suffers from a limited applicable frequency range due to the mass of the sample and DSC cell leading to the impingement of thermal conductivity effects. We suggest that the frequency limit can be increased by replacing the cell as the source of temperature modulation with an external gaseous source, directed towards the sample and reference pans. In this evaluation, an alternating gas-flow was passed through a line to a forced gas-flow accessory (FGFA). The FGFA consisted of two matched cylinders containing chambers that allowed pre-temperature-equilibration of the stream of gas before it was passed over the sample and reference pans. The development of this device revealed the essential practical requirements of gas-flow modulation for high-frequency temperature modulation. These include the following: an appropriately sealed tunable gas supply to both sample and reference pans, an effective method for high-frequency cycling of the gas-flow rate, a small aperture to deliver the flowing gas directly over the pan and a temperature equilibration chamber. The results from samples of quenched PET and amorphous Saquinavir indicate that gas-flow modulation is indeed feasible, with the FGFA able to raise the attainable temperature modulation frequency by an order of magnitude compared to conventional MTDSC.</abstract><cop>Dordrecht</cop><pub>Springer Nature B.V</pub><doi>10.1023/A:1010143304958</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1388-6150
ispartof Journal of thermal analysis and calorimetry, 2000-01, Vol.60 (3), p.795-805
issn 1388-6150
1588-2926
language eng
recordid cdi_proquest_journals_2664061650
source SpringerLink Journals - AutoHoldings
subjects Balancing
Cylindrical chambers
Differential scanning calorimetry
Feasibility
Flow velocity
Frequency ranges
Gas flow
Modulation
Thermal conductivity
title The Development of Gas-flow Modulation for High-frequency MTDSC measurements
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T23%3A04%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Development%20of%20Gas-flow%20Modulation%20for%20High-frequency%20MTDSC%20measurements&rft.jtitle=Journal%20of%20thermal%20analysis%20and%20calorimetry&rft.au=Royall,%20P%20G&rft.date=2000-01-01&rft.volume=60&rft.issue=3&rft.spage=795&rft.epage=805&rft.pages=795-805&rft.issn=1388-6150&rft.eissn=1588-2926&rft_id=info:doi/10.1023/A:1010143304958&rft_dat=%3Cproquest%3E2664061650%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2664061650&rft_id=info:pmid/&rfr_iscdi=true