Structural mechanical simulation to optimize the sensor arm geometry to be implemented on cranial remodeling orthosis

For the treatment of moderate and severe cases of deformational plagiocephaly, an asymmetrical deformation of the skull, a cranial remodeling orthosis (CRO) is used. For the development of a new CRO concept, a pressure sensor grid is placed inside the orthosis that will allow the monitoring of exces...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Veloso, F., Miranda, D., Morais, Pedro, Torres, Helena R., Laranjeira, Roberto, Ruediger, Mario, Miranda, F., Pinho, António C. M., Vilaça, J. L.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page
container_title
container_volume 2425
creator Veloso, F.
Miranda, D.
Morais, Pedro
Torres, Helena R.
Laranjeira, Roberto
Ruediger, Mario
Miranda, F.
Pinho, António C. M.
Vilaça, J. L.
description For the treatment of moderate and severe cases of deformational plagiocephaly, an asymmetrical deformation of the skull, a cranial remodeling orthosis (CRO) is used. For the development of a new CRO concept, a pressure sensor grid is placed inside the orthosis that will allow the monitoring of excessive pressures and incorrect CRO positioning throughout the treatment. To implement the sensor grid in the CRO, high mobility of the sensor arms structure that joins the several sensors of this grid is required, however, it is intended that this procedure does not damage the printed copper tracks on the sensor structure. In this study, computer simulations were performed to optimize the sensor arm structure geometry, minimizing undesirable mechanical behavior in the sensor structure when subjected to tensile forces and displacements applied during its placement in the CRO. It was observed that the different sensor arm structures geometries have different effects on the mechanical behavior of the sensor structure when subjected to tensile forces and tensile displacement. The zigzag curve geometry presents the best performance based on high mobility without intense strain on the structure that could damage the printed copper tracks.
doi_str_mv 10.1063/5.0081312
format Conference Proceeding
fullrecord <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_proquest_journals_2647436021</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2647436021</sourcerecordid><originalsourceid>FETCH-LOGICAL-p194t-2db55105d2d9783eb268aabc5c59363f9ce667a41dd851f02d5ee4a568bace53</originalsourceid><addsrcrecordid>eNp9kUtPwzAQhC0EEqVw4B9Y4oYU8CN2kiOqeEmVONADt8ixN62rOA62g1R-PSmtxI3T7uGbWc0sQteU3FEi-b24I6SknLITNKNC0KyQVJ6iGSFVnrGcf5yjixi3hLCqKMoZGt9TGHUag-qwA71RvdXTGq0bO5Ws73Hy2A_JOvsNOG0AR-ijD1gFh9fgHaSw2zMNYOuGDhz0CQyehDpMZpNXAOcNdLZfYx_SxkcbL9FZq7oIV8c5R6unx9XiJVu-Pb8uHpbZQKs8Zcw0UwQiDDNVUXJomCyVarTQouKSt5UGKQuVU2NKQVvCjADIlZBlozQIPkc3B9sh-M8RYqq3fgz9dLFmMi9yLgmjE3V7oKK26TdzPQTrVNjVXz7Uoj42Wg-m_Q-mpN6_4E_AfwDaCHsm</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>2647436021</pqid></control><display><type>conference_proceeding</type><title>Structural mechanical simulation to optimize the sensor arm geometry to be implemented on cranial remodeling orthosis</title><source>AIP Journals Complete</source><creator>Veloso, F. ; Miranda, D. ; Morais, Pedro ; Torres, Helena R. ; Laranjeira, Roberto ; Ruediger, Mario ; Miranda, F. ; Pinho, António C. M. ; Vilaça, J. L.</creator><contributor>Simos, Theodore ; Tsitouras, Charalambos</contributor><creatorcontrib>Veloso, F. ; Miranda, D. ; Morais, Pedro ; Torres, Helena R. ; Laranjeira, Roberto ; Ruediger, Mario ; Miranda, F. ; Pinho, António C. M. ; Vilaça, J. L. ; Simos, Theodore ; Tsitouras, Charalambos</creatorcontrib><description>For the treatment of moderate and severe cases of deformational plagiocephaly, an asymmetrical deformation of the skull, a cranial remodeling orthosis (CRO) is used. For the development of a new CRO concept, a pressure sensor grid is placed inside the orthosis that will allow the monitoring of excessive pressures and incorrect CRO positioning throughout the treatment. To implement the sensor grid in the CRO, high mobility of the sensor arms structure that joins the several sensors of this grid is required, however, it is intended that this procedure does not damage the printed copper tracks on the sensor structure. In this study, computer simulations were performed to optimize the sensor arm structure geometry, minimizing undesirable mechanical behavior in the sensor structure when subjected to tensile forces and displacements applied during its placement in the CRO. It was observed that the different sensor arm structures geometries have different effects on the mechanical behavior of the sensor structure when subjected to tensile forces and tensile displacement. The zigzag curve geometry presents the best performance based on high mobility without intense strain on the structure that could damage the printed copper tracks.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/5.0081312</identifier><identifier>CODEN: APCPCS</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Copper ; Damage ; Deformation ; Geometry ; Mechanical properties ; Orthoses ; Pressure sensors ; Sensors</subject><ispartof>AIP conference proceedings, 2022, Vol.2425 (1)</ispartof><rights>Author(s)</rights><rights>2022 Author(s). Published by AIP Publishing.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/acp/article-lookup/doi/10.1063/5.0081312$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>309,310,314,777,781,786,787,791,4498,23911,23912,25121,27905,27906,76133</link.rule.ids></links><search><contributor>Simos, Theodore</contributor><contributor>Tsitouras, Charalambos</contributor><creatorcontrib>Veloso, F.</creatorcontrib><creatorcontrib>Miranda, D.</creatorcontrib><creatorcontrib>Morais, Pedro</creatorcontrib><creatorcontrib>Torres, Helena R.</creatorcontrib><creatorcontrib>Laranjeira, Roberto</creatorcontrib><creatorcontrib>Ruediger, Mario</creatorcontrib><creatorcontrib>Miranda, F.</creatorcontrib><creatorcontrib>Pinho, António C. M.</creatorcontrib><creatorcontrib>Vilaça, J. L.</creatorcontrib><title>Structural mechanical simulation to optimize the sensor arm geometry to be implemented on cranial remodeling orthosis</title><title>AIP conference proceedings</title><description>For the treatment of moderate and severe cases of deformational plagiocephaly, an asymmetrical deformation of the skull, a cranial remodeling orthosis (CRO) is used. For the development of a new CRO concept, a pressure sensor grid is placed inside the orthosis that will allow the monitoring of excessive pressures and incorrect CRO positioning throughout the treatment. To implement the sensor grid in the CRO, high mobility of the sensor arms structure that joins the several sensors of this grid is required, however, it is intended that this procedure does not damage the printed copper tracks on the sensor structure. In this study, computer simulations were performed to optimize the sensor arm structure geometry, minimizing undesirable mechanical behavior in the sensor structure when subjected to tensile forces and displacements applied during its placement in the CRO. It was observed that the different sensor arm structures geometries have different effects on the mechanical behavior of the sensor structure when subjected to tensile forces and tensile displacement. The zigzag curve geometry presents the best performance based on high mobility without intense strain on the structure that could damage the printed copper tracks.</description><subject>Copper</subject><subject>Damage</subject><subject>Deformation</subject><subject>Geometry</subject><subject>Mechanical properties</subject><subject>Orthoses</subject><subject>Pressure sensors</subject><subject>Sensors</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2022</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNp9kUtPwzAQhC0EEqVw4B9Y4oYU8CN2kiOqeEmVONADt8ixN62rOA62g1R-PSmtxI3T7uGbWc0sQteU3FEi-b24I6SknLITNKNC0KyQVJ6iGSFVnrGcf5yjixi3hLCqKMoZGt9TGHUag-qwA71RvdXTGq0bO5Ws73Hy2A_JOvsNOG0AR-ijD1gFh9fgHaSw2zMNYOuGDhz0CQyehDpMZpNXAOcNdLZfYx_SxkcbL9FZq7oIV8c5R6unx9XiJVu-Pb8uHpbZQKs8Zcw0UwQiDDNVUXJomCyVarTQouKSt5UGKQuVU2NKQVvCjADIlZBlozQIPkc3B9sh-M8RYqq3fgz9dLFmMi9yLgmjE3V7oKK26TdzPQTrVNjVXz7Uoj42Wg-m_Q-mpN6_4E_AfwDaCHsm</recordid><startdate>20220406</startdate><enddate>20220406</enddate><creator>Veloso, F.</creator><creator>Miranda, D.</creator><creator>Morais, Pedro</creator><creator>Torres, Helena R.</creator><creator>Laranjeira, Roberto</creator><creator>Ruediger, Mario</creator><creator>Miranda, F.</creator><creator>Pinho, António C. M.</creator><creator>Vilaça, J. L.</creator><general>American Institute of Physics</general><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20220406</creationdate><title>Structural mechanical simulation to optimize the sensor arm geometry to be implemented on cranial remodeling orthosis</title><author>Veloso, F. ; Miranda, D. ; Morais, Pedro ; Torres, Helena R. ; Laranjeira, Roberto ; Ruediger, Mario ; Miranda, F. ; Pinho, António C. M. ; Vilaça, J. L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p194t-2db55105d2d9783eb268aabc5c59363f9ce667a41dd851f02d5ee4a568bace53</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Copper</topic><topic>Damage</topic><topic>Deformation</topic><topic>Geometry</topic><topic>Mechanical properties</topic><topic>Orthoses</topic><topic>Pressure sensors</topic><topic>Sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Veloso, F.</creatorcontrib><creatorcontrib>Miranda, D.</creatorcontrib><creatorcontrib>Morais, Pedro</creatorcontrib><creatorcontrib>Torres, Helena R.</creatorcontrib><creatorcontrib>Laranjeira, Roberto</creatorcontrib><creatorcontrib>Ruediger, Mario</creatorcontrib><creatorcontrib>Miranda, F.</creatorcontrib><creatorcontrib>Pinho, António C. M.</creatorcontrib><creatorcontrib>Vilaça, J. L.</creatorcontrib><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Veloso, F.</au><au>Miranda, D.</au><au>Morais, Pedro</au><au>Torres, Helena R.</au><au>Laranjeira, Roberto</au><au>Ruediger, Mario</au><au>Miranda, F.</au><au>Pinho, António C. M.</au><au>Vilaça, J. L.</au><au>Simos, Theodore</au><au>Tsitouras, Charalambos</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Structural mechanical simulation to optimize the sensor arm geometry to be implemented on cranial remodeling orthosis</atitle><btitle>AIP conference proceedings</btitle><date>2022-04-06</date><risdate>2022</risdate><volume>2425</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><coden>APCPCS</coden><abstract>For the treatment of moderate and severe cases of deformational plagiocephaly, an asymmetrical deformation of the skull, a cranial remodeling orthosis (CRO) is used. For the development of a new CRO concept, a pressure sensor grid is placed inside the orthosis that will allow the monitoring of excessive pressures and incorrect CRO positioning throughout the treatment. To implement the sensor grid in the CRO, high mobility of the sensor arms structure that joins the several sensors of this grid is required, however, it is intended that this procedure does not damage the printed copper tracks on the sensor structure. In this study, computer simulations were performed to optimize the sensor arm structure geometry, minimizing undesirable mechanical behavior in the sensor structure when subjected to tensile forces and displacements applied during its placement in the CRO. It was observed that the different sensor arm structures geometries have different effects on the mechanical behavior of the sensor structure when subjected to tensile forces and tensile displacement. The zigzag curve geometry presents the best performance based on high mobility without intense strain on the structure that could damage the printed copper tracks.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/5.0081312</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0094-243X
ispartof AIP conference proceedings, 2022, Vol.2425 (1)
issn 0094-243X
1551-7616
language eng
recordid cdi_proquest_journals_2647436021
source AIP Journals Complete
subjects Copper
Damage
Deformation
Geometry
Mechanical properties
Orthoses
Pressure sensors
Sensors
title Structural mechanical simulation to optimize the sensor arm geometry to be implemented on cranial remodeling orthosis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T07%3A15%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Structural%20mechanical%20simulation%20to%20optimize%20the%20sensor%20arm%20geometry%20to%20be%20implemented%20on%20cranial%20remodeling%20orthosis&rft.btitle=AIP%20conference%20proceedings&rft.au=Veloso,%20F.&rft.date=2022-04-06&rft.volume=2425&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft.coden=APCPCS&rft_id=info:doi/10.1063/5.0081312&rft_dat=%3Cproquest_scita%3E2647436021%3C/proquest_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2647436021&rft_id=info:pmid/&rfr_iscdi=true