Vital signs measurements & development for e-health care application

A non-invasive medical device that measures pulse rate, blood oxygenation, and electrocardiogram readings. The sensor module was built to send information to the app so they can see the results on their phone. The sensors are connected to the microcontroller via an analogue to digital interface. to...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Shamini, R., Joshua, K. Paul, Nithya, N., Sivakamasundari, P., Revathi, M., Sakthisudhan, K.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page
container_title
container_volume 2385
creator Shamini, R.
Joshua, K. Paul
Nithya, N.
Sivakamasundari, P.
Revathi, M.
Sakthisudhan, K.
description A non-invasive medical device that measures pulse rate, blood oxygenation, and electrocardiogram readings. The sensor module was built to send information to the app so they can see the results on their phone. The sensors are connected to the microcontroller via an analogue to digital interface. to maintain patients' health as well as in the event of a critical situation, the buzzer is used. as a complete and integrated platform for a wide range of biomedical uses These six assessment tools are available both on a mobile device and for the patient. Number of patients may be referenced in the cloud in the future using Thing speak unit You won't have to wear the device at the time of each need anymore, instead you can leave it on continuously for a low cost. operates on the patient's psychological endowment.
doi_str_mv 10.1063/5.0070810
format Conference Proceeding
fullrecord <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_proquest_journals_2617080463</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2617080463</sourcerecordid><originalsourceid>FETCH-LOGICAL-p168t-748de563665a729af7be23bbc9f2bba35826116f7cb04065784628bd2801c9013</originalsourceid><addsrcrecordid>eNp9kEtLxDAUhYMoWEcX_oOA4ELoeJM0jy5lfMKAGxV3IWlTp0MfMWkH_Pe2zIA7V5cL3zn3noPQJYElAcFu-RJAgiJwhBLCOUmlIOIYJQB5ltKMfZ6isxi3ADSXUiXo_qMeTINj_dVF3DoTx-Ba1w0RX-PS7VzT-3nFVR-wSzfONMMGFyY4bLxv6sIMdd-do5PKNNFdHOYCvT8-vK2e0_Xr08vqbp16ItSQykyVjgsmBDeS5qaS1lFmbZFX1FrDuKKCEFHJwkIGgkuVCapsSRWQIgfCFuhq7-tD_z26OOhtP4ZuOqkn5RQbMsEm6mZPxWLKNv-nfahbE370rg-a60ND2pfVf_BEzJX-CdgvAoNmvQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>2617080463</pqid></control><display><type>conference_proceeding</type><title>Vital signs measurements &amp; development for e-health care application</title><source>AIP Journals Complete</source><creator>Shamini, R. ; Joshua, K. Paul ; Nithya, N. ; Sivakamasundari, P. ; Revathi, M. ; Sakthisudhan, K.</creator><contributor>Sunil, J.</contributor><creatorcontrib>Shamini, R. ; Joshua, K. Paul ; Nithya, N. ; Sivakamasundari, P. ; Revathi, M. ; Sakthisudhan, K. ; Sunil, J.</creatorcontrib><description>A non-invasive medical device that measures pulse rate, blood oxygenation, and electrocardiogram readings. The sensor module was built to send information to the app so they can see the results on their phone. The sensors are connected to the microcontroller via an analogue to digital interface. to maintain patients' health as well as in the event of a critical situation, the buzzer is used. as a complete and integrated platform for a wide range of biomedical uses These six assessment tools are available both on a mobile device and for the patient. Number of patients may be referenced in the cloud in the future using Thing speak unit You won't have to wear the device at the time of each need anymore, instead you can leave it on continuously for a low cost. operates on the patient's psychological endowment.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/5.0070810</identifier><identifier>CODEN: APCPCS</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Electrocardiography ; Electronic devices ; Medical equipment ; Microcontrollers ; Oxygenation ; Pulse rate</subject><ispartof>AIP conference proceedings, 2022, Vol.2385 (1)</ispartof><rights>Author(s)</rights><rights>2022 Author(s). Published by AIP Publishing.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/acp/article-lookup/doi/10.1063/5.0070810$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,794,4511,23929,23930,25139,27923,27924,76255</link.rule.ids></links><search><contributor>Sunil, J.</contributor><creatorcontrib>Shamini, R.</creatorcontrib><creatorcontrib>Joshua, K. Paul</creatorcontrib><creatorcontrib>Nithya, N.</creatorcontrib><creatorcontrib>Sivakamasundari, P.</creatorcontrib><creatorcontrib>Revathi, M.</creatorcontrib><creatorcontrib>Sakthisudhan, K.</creatorcontrib><title>Vital signs measurements &amp; development for e-health care application</title><title>AIP conference proceedings</title><description>A non-invasive medical device that measures pulse rate, blood oxygenation, and electrocardiogram readings. The sensor module was built to send information to the app so they can see the results on their phone. The sensors are connected to the microcontroller via an analogue to digital interface. to maintain patients' health as well as in the event of a critical situation, the buzzer is used. as a complete and integrated platform for a wide range of biomedical uses These six assessment tools are available both on a mobile device and for the patient. Number of patients may be referenced in the cloud in the future using Thing speak unit You won't have to wear the device at the time of each need anymore, instead you can leave it on continuously for a low cost. operates on the patient's psychological endowment.</description><subject>Electrocardiography</subject><subject>Electronic devices</subject><subject>Medical equipment</subject><subject>Microcontrollers</subject><subject>Oxygenation</subject><subject>Pulse rate</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2022</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNp9kEtLxDAUhYMoWEcX_oOA4ELoeJM0jy5lfMKAGxV3IWlTp0MfMWkH_Pe2zIA7V5cL3zn3noPQJYElAcFu-RJAgiJwhBLCOUmlIOIYJQB5ltKMfZ6isxi3ADSXUiXo_qMeTINj_dVF3DoTx-Ba1w0RX-PS7VzT-3nFVR-wSzfONMMGFyY4bLxv6sIMdd-do5PKNNFdHOYCvT8-vK2e0_Xr08vqbp16ItSQykyVjgsmBDeS5qaS1lFmbZFX1FrDuKKCEFHJwkIGgkuVCapsSRWQIgfCFuhq7-tD_z26OOhtP4ZuOqkn5RQbMsEm6mZPxWLKNv-nfahbE370rg-a60ND2pfVf_BEzJX-CdgvAoNmvQ</recordid><startdate>20220106</startdate><enddate>20220106</enddate><creator>Shamini, R.</creator><creator>Joshua, K. Paul</creator><creator>Nithya, N.</creator><creator>Sivakamasundari, P.</creator><creator>Revathi, M.</creator><creator>Sakthisudhan, K.</creator><general>American Institute of Physics</general><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20220106</creationdate><title>Vital signs measurements &amp; development for e-health care application</title><author>Shamini, R. ; Joshua, K. Paul ; Nithya, N. ; Sivakamasundari, P. ; Revathi, M. ; Sakthisudhan, K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p168t-748de563665a729af7be23bbc9f2bba35826116f7cb04065784628bd2801c9013</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Electrocardiography</topic><topic>Electronic devices</topic><topic>Medical equipment</topic><topic>Microcontrollers</topic><topic>Oxygenation</topic><topic>Pulse rate</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shamini, R.</creatorcontrib><creatorcontrib>Joshua, K. Paul</creatorcontrib><creatorcontrib>Nithya, N.</creatorcontrib><creatorcontrib>Sivakamasundari, P.</creatorcontrib><creatorcontrib>Revathi, M.</creatorcontrib><creatorcontrib>Sakthisudhan, K.</creatorcontrib><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shamini, R.</au><au>Joshua, K. Paul</au><au>Nithya, N.</au><au>Sivakamasundari, P.</au><au>Revathi, M.</au><au>Sakthisudhan, K.</au><au>Sunil, J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Vital signs measurements &amp; development for e-health care application</atitle><btitle>AIP conference proceedings</btitle><date>2022-01-06</date><risdate>2022</risdate><volume>2385</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><coden>APCPCS</coden><abstract>A non-invasive medical device that measures pulse rate, blood oxygenation, and electrocardiogram readings. The sensor module was built to send information to the app so they can see the results on their phone. The sensors are connected to the microcontroller via an analogue to digital interface. to maintain patients' health as well as in the event of a critical situation, the buzzer is used. as a complete and integrated platform for a wide range of biomedical uses These six assessment tools are available both on a mobile device and for the patient. Number of patients may be referenced in the cloud in the future using Thing speak unit You won't have to wear the device at the time of each need anymore, instead you can leave it on continuously for a low cost. operates on the patient's psychological endowment.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/5.0070810</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-243X
ispartof AIP conference proceedings, 2022, Vol.2385 (1)
issn 0094-243X
1551-7616
language eng
recordid cdi_proquest_journals_2617080463
source AIP Journals Complete
subjects Electrocardiography
Electronic devices
Medical equipment
Microcontrollers
Oxygenation
Pulse rate
title Vital signs measurements & development for e-health care application
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T08%3A40%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Vital%20signs%20measurements%20&%20development%20for%20e-health%20care%20application&rft.btitle=AIP%20conference%20proceedings&rft.au=Shamini,%20R.&rft.date=2022-01-06&rft.volume=2385&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft.coden=APCPCS&rft_id=info:doi/10.1063/5.0070810&rft_dat=%3Cproquest_scita%3E2617080463%3C/proquest_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2617080463&rft_id=info:pmid/&rfr_iscdi=true