Improvement in metal vapor laser performance with reduction in localized electric field at electrodes
Electrode geometry plays a vital role in metal vapor laser performance. It has been observed that by modifying the electrode geometry, the electric field enhancement near the electrode can be reduced. Reduction in the localized electric field causes reduction in the phantom current in the metal vapo...
Gespeichert in:
Veröffentlicht in: | Review of scientific instruments 2022-01, Vol.93 (1), p.013004-013004 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 013004 |
---|---|
container_issue | 1 |
container_start_page | 013004 |
container_title | Review of scientific instruments |
container_volume | 93 |
creator | Singh, Dheeraj K. Dikshit, B. Mukherjee, Jaya Rawat, V. S. |
description | Electrode geometry plays a vital role in metal vapor laser performance. It has been observed that by modifying the electrode geometry, the electric field enhancement near the electrode can be reduced. Reduction in the localized electric field causes reduction in the phantom current in the metal vapor laser. On replacing the electrode geometry having eight pins with an electrode having the zero-pin configuration, a 10% decrease in the phantom current and a 23% increase in optical output power are observed. The low phantom current is responsible for higher efficiencies, large specific average output power, and improved beam characteristics of that laser in reference to a conventional copper vapor laser. It was also observed that reduction in field enhancement causes reduction in the thermal loading at the cathode fall and in the probability of thermal instability, thereby improving the discharge stability and jitter in metal vapor lasers. This simple and effective technique can also be applied to the systems requiring high current and high-volume stable discharge. |
doi_str_mv | 10.1063/5.0070654 |
format | Article |
fullrecord | <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_proquest_journals_2616749941</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2624949763</sourcerecordid><originalsourceid>FETCH-LOGICAL-c383t-ffd4e0f850cdfca55d15db4ac35889ef211b3d3299766b7dd8c0c6faaa4ace373</originalsourceid><addsrcrecordid>eNp90EFL5DAUB_AgijOrHvYLLAEvrlBNmiZtj8vg6sCAFz2XTPKCkbTpJuks-uk3w4wKC_ougcePP3l_hL5TckWJYNf8ipCaCF4doDklTVvUomSHaE4IqwpRV80MfYvxmeThlB6jGeOUVG1N5giW_Rj8BnoYErYD7iFJhzdy9AE7GSHgEYLxoZeDAvzXpiccQE8qWT9svfNKOvsKGoMDlYJV2FhwGsu033gN8RQdGekinO3fE_T4--ZhcVes7m-Xi1-rQrGGpcIYXQExDSdKGyU515TrdSUV403TgikpXTPNyrathVjXWjeKKGGklNkAq9kJutjl5pv-TBBT19uowDk5gJ9iV4qyavPhgmV6_h999lMY8u-yorm0tq1oVj93SgUfYwDTjcH2Mrx0lHTb7jve7bvP9sc-cVr3oN_lW9kZXO5AVDbJbYNfpn2KNz58wG7Uhv0DOTKb5w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2616749941</pqid></control><display><type>article</type><title>Improvement in metal vapor laser performance with reduction in localized electric field at electrodes</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Singh, Dheeraj K. ; Dikshit, B. ; Mukherjee, Jaya ; Rawat, V. S.</creator><creatorcontrib>Singh, Dheeraj K. ; Dikshit, B. ; Mukherjee, Jaya ; Rawat, V. S.</creatorcontrib><description>Electrode geometry plays a vital role in metal vapor laser performance. It has been observed that by modifying the electrode geometry, the electric field enhancement near the electrode can be reduced. Reduction in the localized electric field causes reduction in the phantom current in the metal vapor laser. On replacing the electrode geometry having eight pins with an electrode having the zero-pin configuration, a 10% decrease in the phantom current and a 23% increase in optical output power are observed. The low phantom current is responsible for higher efficiencies, large specific average output power, and improved beam characteristics of that laser in reference to a conventional copper vapor laser. It was also observed that reduction in field enhancement causes reduction in the thermal loading at the cathode fall and in the probability of thermal instability, thereby improving the discharge stability and jitter in metal vapor lasers. This simple and effective technique can also be applied to the systems requiring high current and high-volume stable discharge.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/5.0070654</identifier><identifier>PMID: 35104970</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States: American Institute of Physics</publisher><subject>Discharge ; Electric fields ; Electrodes ; Electrons ; Geometry ; Lasers ; Metal vapor lasers ; Scientific apparatus & instruments ; System effectiveness ; Thermal energy ; Thermal instability ; Vibration</subject><ispartof>Review of scientific instruments, 2022-01, Vol.93 (1), p.013004-013004</ispartof><rights>Author(s)</rights><rights>2022 Author(s). Published under an exclusive license by AIP Publishing.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c383t-ffd4e0f850cdfca55d15db4ac35889ef211b3d3299766b7dd8c0c6faaa4ace373</citedby><cites>FETCH-LOGICAL-c383t-ffd4e0f850cdfca55d15db4ac35889ef211b3d3299766b7dd8c0c6faaa4ace373</cites><orcidid>0000-0001-8361-0987 ; 0000-0002-6231-5951 ; 0000-0003-3056-028X ; s0000000183610987 ; s0000000262315951 ; s000000033056028X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/5.0070654$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,780,784,794,4512,27924,27925,76384</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35104970$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Singh, Dheeraj K.</creatorcontrib><creatorcontrib>Dikshit, B.</creatorcontrib><creatorcontrib>Mukherjee, Jaya</creatorcontrib><creatorcontrib>Rawat, V. S.</creatorcontrib><title>Improvement in metal vapor laser performance with reduction in localized electric field at electrodes</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>Electrode geometry plays a vital role in metal vapor laser performance. It has been observed that by modifying the electrode geometry, the electric field enhancement near the electrode can be reduced. Reduction in the localized electric field causes reduction in the phantom current in the metal vapor laser. On replacing the electrode geometry having eight pins with an electrode having the zero-pin configuration, a 10% decrease in the phantom current and a 23% increase in optical output power are observed. The low phantom current is responsible for higher efficiencies, large specific average output power, and improved beam characteristics of that laser in reference to a conventional copper vapor laser. It was also observed that reduction in field enhancement causes reduction in the thermal loading at the cathode fall and in the probability of thermal instability, thereby improving the discharge stability and jitter in metal vapor lasers. This simple and effective technique can also be applied to the systems requiring high current and high-volume stable discharge.</description><subject>Discharge</subject><subject>Electric fields</subject><subject>Electrodes</subject><subject>Electrons</subject><subject>Geometry</subject><subject>Lasers</subject><subject>Metal vapor lasers</subject><subject>Scientific apparatus & instruments</subject><subject>System effectiveness</subject><subject>Thermal energy</subject><subject>Thermal instability</subject><subject>Vibration</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp90EFL5DAUB_AgijOrHvYLLAEvrlBNmiZtj8vg6sCAFz2XTPKCkbTpJuks-uk3w4wKC_ougcePP3l_hL5TckWJYNf8ipCaCF4doDklTVvUomSHaE4IqwpRV80MfYvxmeThlB6jGeOUVG1N5giW_Rj8BnoYErYD7iFJhzdy9AE7GSHgEYLxoZeDAvzXpiccQE8qWT9svfNKOvsKGoMDlYJV2FhwGsu033gN8RQdGekinO3fE_T4--ZhcVes7m-Xi1-rQrGGpcIYXQExDSdKGyU515TrdSUV403TgikpXTPNyrathVjXWjeKKGGklNkAq9kJutjl5pv-TBBT19uowDk5gJ9iV4qyavPhgmV6_h999lMY8u-yorm0tq1oVj93SgUfYwDTjcH2Mrx0lHTb7jve7bvP9sc-cVr3oN_lW9kZXO5AVDbJbYNfpn2KNz58wG7Uhv0DOTKb5w</recordid><startdate>20220101</startdate><enddate>20220101</enddate><creator>Singh, Dheeraj K.</creator><creator>Dikshit, B.</creator><creator>Mukherjee, Jaya</creator><creator>Rawat, V. S.</creator><general>American Institute of Physics</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-8361-0987</orcidid><orcidid>https://orcid.org/0000-0002-6231-5951</orcidid><orcidid>https://orcid.org/0000-0003-3056-028X</orcidid><orcidid>https://orcid.org/s0000000183610987</orcidid><orcidid>https://orcid.org/s0000000262315951</orcidid><orcidid>https://orcid.org/s000000033056028X</orcidid></search><sort><creationdate>20220101</creationdate><title>Improvement in metal vapor laser performance with reduction in localized electric field at electrodes</title><author>Singh, Dheeraj K. ; Dikshit, B. ; Mukherjee, Jaya ; Rawat, V. S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c383t-ffd4e0f850cdfca55d15db4ac35889ef211b3d3299766b7dd8c0c6faaa4ace373</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Discharge</topic><topic>Electric fields</topic><topic>Electrodes</topic><topic>Electrons</topic><topic>Geometry</topic><topic>Lasers</topic><topic>Metal vapor lasers</topic><topic>Scientific apparatus & instruments</topic><topic>System effectiveness</topic><topic>Thermal energy</topic><topic>Thermal instability</topic><topic>Vibration</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Singh, Dheeraj K.</creatorcontrib><creatorcontrib>Dikshit, B.</creatorcontrib><creatorcontrib>Mukherjee, Jaya</creatorcontrib><creatorcontrib>Rawat, V. S.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Singh, Dheeraj K.</au><au>Dikshit, B.</au><au>Mukherjee, Jaya</au><au>Rawat, V. S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Improvement in metal vapor laser performance with reduction in localized electric field at electrodes</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2022-01-01</date><risdate>2022</risdate><volume>93</volume><issue>1</issue><spage>013004</spage><epage>013004</epage><pages>013004-013004</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>Electrode geometry plays a vital role in metal vapor laser performance. It has been observed that by modifying the electrode geometry, the electric field enhancement near the electrode can be reduced. Reduction in the localized electric field causes reduction in the phantom current in the metal vapor laser. On replacing the electrode geometry having eight pins with an electrode having the zero-pin configuration, a 10% decrease in the phantom current and a 23% increase in optical output power are observed. The low phantom current is responsible for higher efficiencies, large specific average output power, and improved beam characteristics of that laser in reference to a conventional copper vapor laser. It was also observed that reduction in field enhancement causes reduction in the thermal loading at the cathode fall and in the probability of thermal instability, thereby improving the discharge stability and jitter in metal vapor lasers. This simple and effective technique can also be applied to the systems requiring high current and high-volume stable discharge.</abstract><cop>United States</cop><pub>American Institute of Physics</pub><pmid>35104970</pmid><doi>10.1063/5.0070654</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0001-8361-0987</orcidid><orcidid>https://orcid.org/0000-0002-6231-5951</orcidid><orcidid>https://orcid.org/0000-0003-3056-028X</orcidid><orcidid>https://orcid.org/s0000000183610987</orcidid><orcidid>https://orcid.org/s0000000262315951</orcidid><orcidid>https://orcid.org/s000000033056028X</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0034-6748 |
ispartof | Review of scientific instruments, 2022-01, Vol.93 (1), p.013004-013004 |
issn | 0034-6748 1089-7623 |
language | eng |
recordid | cdi_proquest_journals_2616749941 |
source | AIP Journals Complete; Alma/SFX Local Collection |
subjects | Discharge Electric fields Electrodes Electrons Geometry Lasers Metal vapor lasers Scientific apparatus & instruments System effectiveness Thermal energy Thermal instability Vibration |
title | Improvement in metal vapor laser performance with reduction in localized electric field at electrodes |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T12%3A17%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Improvement%20in%20metal%20vapor%20laser%20performance%20with%20reduction%20in%20localized%20electric%20field%20at%20electrodes&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Singh,%20Dheeraj%20K.&rft.date=2022-01-01&rft.volume=93&rft.issue=1&rft.spage=013004&rft.epage=013004&rft.pages=013004-013004&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/5.0070654&rft_dat=%3Cproquest_scita%3E2624949763%3C/proquest_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2616749941&rft_id=info:pmid/35104970&rfr_iscdi=true |