Bridge Method for Studying the Spectra of Current Fluctuations in Tungsten Filaments in the Frequency Range 1.5·10–5–5·10–1 Hz
This article discusses the absence of methods for measuring low-frequency (LF) fluctuation processes at high temperatures and proposes an original bridge method for measuring the spectra of LF current fluctuations in the tungsten filaments of electric lamps in the controlled temperature range 300–27...
Gespeichert in:
Veröffentlicht in: | Measurement techniques 2021, Vol.64 (5), p.364-372 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 372 |
---|---|
container_issue | 5 |
container_start_page | 364 |
container_title | Measurement techniques |
container_volume | 64 |
creator | Zakharov, Yu. A. Gots, S. S. Bakhtizin, R. Z. |
description | This article discusses the absence of methods for measuring low-frequency (LF) fluctuation processes at high temperatures and proposes an original bridge method for measuring the spectra of LF current fluctuations in the tungsten filaments of electric lamps in the controlled temperature range 300–2700 K. The application of the bridge measurement circuit reduces the influence of degradation processes in the filament and the power source’s own noise on the measurement results by several orders of magnitude. A spectral analysis of LF current fluctuations is performed in the frequency range 1.5·10
–5
–5·10
–1
Hz using an automated unit based on a personal computer under the control of specially developed software. |
doi_str_mv | 10.1007/s11018-021-01942-0 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2592338717</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2592338717</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1640-fa003689e6c78115cf564af90a8f85e1cabc33b90b2c68d9b53e69224d0424903</originalsourceid><addsrcrecordid>eNp9UL1OwzAQthBIlJ8XYLLEHLiz4yQeoaIUqQiJwmy5jlOCilNsZygTEy_Aw7DzKDwJLkViYzjd6fT93H2EHCGcIEB5GhABqwwYZoAyZxlskQGKkmeVhGKbDEDkPENZsl2yF8IjAPCykAPydu7bem7ptY0PXU2bztNp7OtV6-Y0Plg6XVoTvaZdQ4e999ZFOlr0JvY6tp0LtHX0rnfzEK2jo3ahnxLiZ7smj7x97q0zK3qrXTLBE_H5gfD1-i7W9TsjHb8ckJ1GL4I9_O375H50cTccZ5Oby6vh2SQzWOSQNTrdXVTSFqasEIVpRJHrRoKumkpYNHpmOJ9JmDFTVLWcCW4LyVheQ85yCXyfHG90l75Lp4WoHrveu2SpmJCM86rEMqHYBmV8F4K3jVr69kn7lUJQ67zVJm-V8lY_eau1NN-QQgKnb_2f9D-sb4xjhaw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2592338717</pqid></control><display><type>article</type><title>Bridge Method for Studying the Spectra of Current Fluctuations in Tungsten Filaments in the Frequency Range 1.5·10–5–5·10–1 Hz</title><source>Springer Journals</source><creator>Zakharov, Yu. A. ; Gots, S. S. ; Bakhtizin, R. Z.</creator><creatorcontrib>Zakharov, Yu. A. ; Gots, S. S. ; Bakhtizin, R. Z.</creatorcontrib><description>This article discusses the absence of methods for measuring low-frequency (LF) fluctuation processes at high temperatures and proposes an original bridge method for measuring the spectra of LF current fluctuations in the tungsten filaments of electric lamps in the controlled temperature range 300–2700 K. The application of the bridge measurement circuit reduces the influence of degradation processes in the filament and the power source’s own noise on the measurement results by several orders of magnitude. A spectral analysis of LF current fluctuations is performed in the frequency range 1.5·10
–5
–5·10
–1
Hz using an automated unit based on a personal computer under the control of specially developed software.</description><identifier>ISSN: 0543-1972</identifier><identifier>EISSN: 1573-8906</identifier><identifier>DOI: 10.1007/s11018-021-01942-0</identifier><language>eng</language><publisher>New York: Springer US</publisher><subject>Analytical Chemistry ; Characterization and Evaluation of Materials ; Circuits ; Electric lamps ; Filaments ; Frequency ranges ; High temperature ; Measurement methods ; Measurement Science and Instrumentation ; Noise measurement ; Personal computers ; Physical Chemistry ; Physics ; Physics and Astronomy ; Power sources ; Spectra ; Spectrum analysis ; Thermophysical Measurements ; Tungsten</subject><ispartof>Measurement techniques, 2021, Vol.64 (5), p.364-372</ispartof><rights>Springer Science+Business Media, LLC, part of Springer Nature 2021</rights><rights>Springer Science+Business Media, LLC, part of Springer Nature 2021.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1640-fa003689e6c78115cf564af90a8f85e1cabc33b90b2c68d9b53e69224d0424903</citedby><cites>FETCH-LOGICAL-c1640-fa003689e6c78115cf564af90a8f85e1cabc33b90b2c68d9b53e69224d0424903</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s11018-021-01942-0$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s11018-021-01942-0$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,41464,42533,51294</link.rule.ids></links><search><creatorcontrib>Zakharov, Yu. A.</creatorcontrib><creatorcontrib>Gots, S. S.</creatorcontrib><creatorcontrib>Bakhtizin, R. Z.</creatorcontrib><title>Bridge Method for Studying the Spectra of Current Fluctuations in Tungsten Filaments in the Frequency Range 1.5·10–5–5·10–1 Hz</title><title>Measurement techniques</title><addtitle>Meas Tech</addtitle><description>This article discusses the absence of methods for measuring low-frequency (LF) fluctuation processes at high temperatures and proposes an original bridge method for measuring the spectra of LF current fluctuations in the tungsten filaments of electric lamps in the controlled temperature range 300–2700 K. The application of the bridge measurement circuit reduces the influence of degradation processes in the filament and the power source’s own noise on the measurement results by several orders of magnitude. A spectral analysis of LF current fluctuations is performed in the frequency range 1.5·10
–5
–5·10
–1
Hz using an automated unit based on a personal computer under the control of specially developed software.</description><subject>Analytical Chemistry</subject><subject>Characterization and Evaluation of Materials</subject><subject>Circuits</subject><subject>Electric lamps</subject><subject>Filaments</subject><subject>Frequency ranges</subject><subject>High temperature</subject><subject>Measurement methods</subject><subject>Measurement Science and Instrumentation</subject><subject>Noise measurement</subject><subject>Personal computers</subject><subject>Physical Chemistry</subject><subject>Physics</subject><subject>Physics and Astronomy</subject><subject>Power sources</subject><subject>Spectra</subject><subject>Spectrum analysis</subject><subject>Thermophysical Measurements</subject><subject>Tungsten</subject><issn>0543-1972</issn><issn>1573-8906</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9UL1OwzAQthBIlJ8XYLLEHLiz4yQeoaIUqQiJwmy5jlOCilNsZygTEy_Aw7DzKDwJLkViYzjd6fT93H2EHCGcIEB5GhABqwwYZoAyZxlskQGKkmeVhGKbDEDkPENZsl2yF8IjAPCykAPydu7bem7ptY0PXU2bztNp7OtV6-Y0Plg6XVoTvaZdQ4e999ZFOlr0JvY6tp0LtHX0rnfzEK2jo3ahnxLiZ7smj7x97q0zK3qrXTLBE_H5gfD1-i7W9TsjHb8ckJ1GL4I9_O375H50cTccZ5Oby6vh2SQzWOSQNTrdXVTSFqasEIVpRJHrRoKumkpYNHpmOJ9JmDFTVLWcCW4LyVheQ85yCXyfHG90l75Lp4WoHrveu2SpmJCM86rEMqHYBmV8F4K3jVr69kn7lUJQ67zVJm-V8lY_eau1NN-QQgKnb_2f9D-sb4xjhaw</recordid><startdate>2021</startdate><enddate>2021</enddate><creator>Zakharov, Yu. A.</creator><creator>Gots, S. S.</creator><creator>Bakhtizin, R. Z.</creator><general>Springer US</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>JQ2</scope><scope>L7M</scope></search><sort><creationdate>2021</creationdate><title>Bridge Method for Studying the Spectra of Current Fluctuations in Tungsten Filaments in the Frequency Range 1.5·10–5–5·10–1 Hz</title><author>Zakharov, Yu. A. ; Gots, S. S. ; Bakhtizin, R. Z.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1640-fa003689e6c78115cf564af90a8f85e1cabc33b90b2c68d9b53e69224d0424903</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Analytical Chemistry</topic><topic>Characterization and Evaluation of Materials</topic><topic>Circuits</topic><topic>Electric lamps</topic><topic>Filaments</topic><topic>Frequency ranges</topic><topic>High temperature</topic><topic>Measurement methods</topic><topic>Measurement Science and Instrumentation</topic><topic>Noise measurement</topic><topic>Personal computers</topic><topic>Physical Chemistry</topic><topic>Physics</topic><topic>Physics and Astronomy</topic><topic>Power sources</topic><topic>Spectra</topic><topic>Spectrum analysis</topic><topic>Thermophysical Measurements</topic><topic>Tungsten</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zakharov, Yu. A.</creatorcontrib><creatorcontrib>Gots, S. S.</creatorcontrib><creatorcontrib>Bakhtizin, R. Z.</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Measurement techniques</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zakharov, Yu. A.</au><au>Gots, S. S.</au><au>Bakhtizin, R. Z.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Bridge Method for Studying the Spectra of Current Fluctuations in Tungsten Filaments in the Frequency Range 1.5·10–5–5·10–1 Hz</atitle><jtitle>Measurement techniques</jtitle><stitle>Meas Tech</stitle><date>2021</date><risdate>2021</risdate><volume>64</volume><issue>5</issue><spage>364</spage><epage>372</epage><pages>364-372</pages><issn>0543-1972</issn><eissn>1573-8906</eissn><abstract>This article discusses the absence of methods for measuring low-frequency (LF) fluctuation processes at high temperatures and proposes an original bridge method for measuring the spectra of LF current fluctuations in the tungsten filaments of electric lamps in the controlled temperature range 300–2700 K. The application of the bridge measurement circuit reduces the influence of degradation processes in the filament and the power source’s own noise on the measurement results by several orders of magnitude. A spectral analysis of LF current fluctuations is performed in the frequency range 1.5·10
–5
–5·10
–1
Hz using an automated unit based on a personal computer under the control of specially developed software.</abstract><cop>New York</cop><pub>Springer US</pub><doi>10.1007/s11018-021-01942-0</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0543-1972 |
ispartof | Measurement techniques, 2021, Vol.64 (5), p.364-372 |
issn | 0543-1972 1573-8906 |
language | eng |
recordid | cdi_proquest_journals_2592338717 |
source | Springer Journals |
subjects | Analytical Chemistry Characterization and Evaluation of Materials Circuits Electric lamps Filaments Frequency ranges High temperature Measurement methods Measurement Science and Instrumentation Noise measurement Personal computers Physical Chemistry Physics Physics and Astronomy Power sources Spectra Spectrum analysis Thermophysical Measurements Tungsten |
title | Bridge Method for Studying the Spectra of Current Fluctuations in Tungsten Filaments in the Frequency Range 1.5·10–5–5·10–1 Hz |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-12T01%3A58%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Bridge%20Method%20for%20Studying%20the%20Spectra%20of%20Current%20Fluctuations%20in%20Tungsten%20Filaments%20in%20the%20Frequency%20Range%201.5%C2%B710%E2%80%935%E2%80%935%C2%B710%E2%80%931%20Hz&rft.jtitle=Measurement%20techniques&rft.au=Zakharov,%20Yu.%20A.&rft.date=2021&rft.volume=64&rft.issue=5&rft.spage=364&rft.epage=372&rft.pages=364-372&rft.issn=0543-1972&rft.eissn=1573-8906&rft_id=info:doi/10.1007/s11018-021-01942-0&rft_dat=%3Cproquest_cross%3E2592338717%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2592338717&rft_id=info:pmid/&rfr_iscdi=true |