A new data-driven method based on Niching Genetic Algorithms for phase and substation identification

•The phase identification problem can be addressed as an optimization problem.•The algorithm works with less than 100% of smart meters installed and missing data.•The correlation on variations of load consumption allows better phase identification.•Evolutionary Algorithms provide accurate estimation...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electric power systems research 2021-10, Vol.199, p.107434, Article 107434
Hauptverfasser: Jimenez, Victor Adrian, Will, Adrian
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 107434
container_title Electric power systems research
container_volume 199
creator Jimenez, Victor Adrian
Will, Adrian
description •The phase identification problem can be addressed as an optimization problem.•The algorithm works with less than 100% of smart meters installed and missing data.•The correlation on variations of load consumption allows better phase identification.•Evolutionary Algorithms provide accurate estimations of customers’ phase connections.•Fewer meters or more missing values require more data to obtain the same precision. Knowledge about the customers’ phase connections is strategic and critical for utility companies. It allows them to optimize maintenance and repair operations, implement load balancing, and detect losses, among other benefits. However, this information may be incomplete or outdated due to the undocumented changes in the Low Voltage network. Several methods have been proposed to estimate it. Methods based on data analysis stand out because they do not require costly specialized equipment. This work presents a new method for Phase Identification and Transformer Substation Detection for single-phase customers. Unlike previous approaches, we address the problem through a heuristic optimization, using an Evolutionary Algorithm based on Deterministic Crowding and correlation analysis on load measurements. The algorithm was designed to work with low penetration of smart meters and missing data, obtaining better results in shorter periods. The method was tested using both a public dataset and a dataset from Tucumán province, Argentina. We obtained an average accuracy above 95% on 21 days if almost 30% of the smart meters are available (200 customers in total). In contrast, only 5 days are required to reach the same accuracy if more than 80% of smart meters are available.
doi_str_mv 10.1016/j.epsr.2021.107434
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2581069418</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0378779621004156</els_id><sourcerecordid>2581069418</sourcerecordid><originalsourceid>FETCH-LOGICAL-c258t-62a2e2e79a948b0e1ce0bce979583099e7910f3b308d09d105774989f766363b3</originalsourceid><addsrcrecordid>eNp9UMtOwzAQtBBIlMIPcLLEOcV2Ho4lLlUFBamCC5wtx940jlon2G4Rf49LOHNa7ezMzu4gdEvJghJa3fcLGINfMMJoAniRF2doRmueZ4wU1TmakZzXGeeiukRXIfSEkErwcobMEjv4wkZFlRlvj-DwHmI3GNyoAAYPDr9a3Vm3xWtwEK3Gy9128DZ2-4DbweOxS0SsnMHh0ISook0aa8BF21r9216ji1btAtz81Tn6eHp8Xz1nm7f1y2q5yTQr65hVTDFgwIUSRd0QoBpIo0FwUdY5ESJNKGnzJie1IcJQUnJeiFq0vKryKuFzdDftHf3weYAQZT8cvEuWMhnQ9HJB68RiE0v7IQQPrRy93Sv_LSmRpzRlL09pylOackoziR4mEaT7jxa8DNqC02CsBx2lGex_8h8Kln1J</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2581069418</pqid></control><display><type>article</type><title>A new data-driven method based on Niching Genetic Algorithms for phase and substation identification</title><source>Elsevier ScienceDirect Journals</source><creator>Jimenez, Victor Adrian ; Will, Adrian</creator><creatorcontrib>Jimenez, Victor Adrian ; Will, Adrian</creatorcontrib><description>•The phase identification problem can be addressed as an optimization problem.•The algorithm works with less than 100% of smart meters installed and missing data.•The correlation on variations of load consumption allows better phase identification.•Evolutionary Algorithms provide accurate estimations of customers’ phase connections.•Fewer meters or more missing values require more data to obtain the same precision. Knowledge about the customers’ phase connections is strategic and critical for utility companies. It allows them to optimize maintenance and repair operations, implement load balancing, and detect losses, among other benefits. However, this information may be incomplete or outdated due to the undocumented changes in the Low Voltage network. Several methods have been proposed to estimate it. Methods based on data analysis stand out because they do not require costly specialized equipment. This work presents a new method for Phase Identification and Transformer Substation Detection for single-phase customers. Unlike previous approaches, we address the problem through a heuristic optimization, using an Evolutionary Algorithm based on Deterministic Crowding and correlation analysis on load measurements. The algorithm was designed to work with low penetration of smart meters and missing data, obtaining better results in shorter periods. The method was tested using both a public dataset and a dataset from Tucumán province, Argentina. We obtained an average accuracy above 95% on 21 days if almost 30% of the smart meters are available (200 customers in total). In contrast, only 5 days are required to reach the same accuracy if more than 80% of smart meters are available.</description><identifier>ISSN: 0378-7796</identifier><identifier>EISSN: 1873-2046</identifier><identifier>DOI: 10.1016/j.epsr.2021.107434</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Correlation analysis ; Cost analysis ; Customers ; Data analysis ; Datasets ; Deterministic crowding ; Evolutionary algorithms ; Genetic algorithm ; Genetic algorithms ; Load consumption measurements ; Low voltage ; Missing data ; Optimization ; Phase identification ; Studies ; Substations ; Transformer substation detection</subject><ispartof>Electric power systems research, 2021-10, Vol.199, p.107434, Article 107434</ispartof><rights>2021 Elsevier B.V.</rights><rights>Copyright Elsevier Science Ltd. Oct 2021</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c258t-62a2e2e79a948b0e1ce0bce979583099e7910f3b308d09d105774989f766363b3</citedby><cites>FETCH-LOGICAL-c258t-62a2e2e79a948b0e1ce0bce979583099e7910f3b308d09d105774989f766363b3</cites><orcidid>0000-0002-4935-8842 ; 0000-0001-9804-1051</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0378779621004156$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Jimenez, Victor Adrian</creatorcontrib><creatorcontrib>Will, Adrian</creatorcontrib><title>A new data-driven method based on Niching Genetic Algorithms for phase and substation identification</title><title>Electric power systems research</title><description>•The phase identification problem can be addressed as an optimization problem.•The algorithm works with less than 100% of smart meters installed and missing data.•The correlation on variations of load consumption allows better phase identification.•Evolutionary Algorithms provide accurate estimations of customers’ phase connections.•Fewer meters or more missing values require more data to obtain the same precision. Knowledge about the customers’ phase connections is strategic and critical for utility companies. It allows them to optimize maintenance and repair operations, implement load balancing, and detect losses, among other benefits. However, this information may be incomplete or outdated due to the undocumented changes in the Low Voltage network. Several methods have been proposed to estimate it. Methods based on data analysis stand out because they do not require costly specialized equipment. This work presents a new method for Phase Identification and Transformer Substation Detection for single-phase customers. Unlike previous approaches, we address the problem through a heuristic optimization, using an Evolutionary Algorithm based on Deterministic Crowding and correlation analysis on load measurements. The algorithm was designed to work with low penetration of smart meters and missing data, obtaining better results in shorter periods. The method was tested using both a public dataset and a dataset from Tucumán province, Argentina. We obtained an average accuracy above 95% on 21 days if almost 30% of the smart meters are available (200 customers in total). In contrast, only 5 days are required to reach the same accuracy if more than 80% of smart meters are available.</description><subject>Correlation analysis</subject><subject>Cost analysis</subject><subject>Customers</subject><subject>Data analysis</subject><subject>Datasets</subject><subject>Deterministic crowding</subject><subject>Evolutionary algorithms</subject><subject>Genetic algorithm</subject><subject>Genetic algorithms</subject><subject>Load consumption measurements</subject><subject>Low voltage</subject><subject>Missing data</subject><subject>Optimization</subject><subject>Phase identification</subject><subject>Studies</subject><subject>Substations</subject><subject>Transformer substation detection</subject><issn>0378-7796</issn><issn>1873-2046</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9UMtOwzAQtBBIlMIPcLLEOcV2Ho4lLlUFBamCC5wtx940jlon2G4Rf49LOHNa7ezMzu4gdEvJghJa3fcLGINfMMJoAniRF2doRmueZ4wU1TmakZzXGeeiukRXIfSEkErwcobMEjv4wkZFlRlvj-DwHmI3GNyoAAYPDr9a3Vm3xWtwEK3Gy9128DZ2-4DbweOxS0SsnMHh0ISook0aa8BF21r9216ji1btAtz81Tn6eHp8Xz1nm7f1y2q5yTQr65hVTDFgwIUSRd0QoBpIo0FwUdY5ESJNKGnzJie1IcJQUnJeiFq0vKryKuFzdDftHf3weYAQZT8cvEuWMhnQ9HJB68RiE0v7IQQPrRy93Sv_LSmRpzRlL09pylOackoziR4mEaT7jxa8DNqC02CsBx2lGex_8h8Kln1J</recordid><startdate>202110</startdate><enddate>202110</enddate><creator>Jimenez, Victor Adrian</creator><creator>Will, Adrian</creator><general>Elsevier B.V</general><general>Elsevier Science Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0002-4935-8842</orcidid><orcidid>https://orcid.org/0000-0001-9804-1051</orcidid></search><sort><creationdate>202110</creationdate><title>A new data-driven method based on Niching Genetic Algorithms for phase and substation identification</title><author>Jimenez, Victor Adrian ; Will, Adrian</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c258t-62a2e2e79a948b0e1ce0bce979583099e7910f3b308d09d105774989f766363b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Correlation analysis</topic><topic>Cost analysis</topic><topic>Customers</topic><topic>Data analysis</topic><topic>Datasets</topic><topic>Deterministic crowding</topic><topic>Evolutionary algorithms</topic><topic>Genetic algorithm</topic><topic>Genetic algorithms</topic><topic>Load consumption measurements</topic><topic>Low voltage</topic><topic>Missing data</topic><topic>Optimization</topic><topic>Phase identification</topic><topic>Studies</topic><topic>Substations</topic><topic>Transformer substation detection</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jimenez, Victor Adrian</creatorcontrib><creatorcontrib>Will, Adrian</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Electric power systems research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jimenez, Victor Adrian</au><au>Will, Adrian</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A new data-driven method based on Niching Genetic Algorithms for phase and substation identification</atitle><jtitle>Electric power systems research</jtitle><date>2021-10</date><risdate>2021</risdate><volume>199</volume><spage>107434</spage><pages>107434-</pages><artnum>107434</artnum><issn>0378-7796</issn><eissn>1873-2046</eissn><abstract>•The phase identification problem can be addressed as an optimization problem.•The algorithm works with less than 100% of smart meters installed and missing data.•The correlation on variations of load consumption allows better phase identification.•Evolutionary Algorithms provide accurate estimations of customers’ phase connections.•Fewer meters or more missing values require more data to obtain the same precision. Knowledge about the customers’ phase connections is strategic and critical for utility companies. It allows them to optimize maintenance and repair operations, implement load balancing, and detect losses, among other benefits. However, this information may be incomplete or outdated due to the undocumented changes in the Low Voltage network. Several methods have been proposed to estimate it. Methods based on data analysis stand out because they do not require costly specialized equipment. This work presents a new method for Phase Identification and Transformer Substation Detection for single-phase customers. Unlike previous approaches, we address the problem through a heuristic optimization, using an Evolutionary Algorithm based on Deterministic Crowding and correlation analysis on load measurements. The algorithm was designed to work with low penetration of smart meters and missing data, obtaining better results in shorter periods. The method was tested using both a public dataset and a dataset from Tucumán province, Argentina. We obtained an average accuracy above 95% on 21 days if almost 30% of the smart meters are available (200 customers in total). In contrast, only 5 days are required to reach the same accuracy if more than 80% of smart meters are available.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/j.epsr.2021.107434</doi><orcidid>https://orcid.org/0000-0002-4935-8842</orcidid><orcidid>https://orcid.org/0000-0001-9804-1051</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0378-7796
ispartof Electric power systems research, 2021-10, Vol.199, p.107434, Article 107434
issn 0378-7796
1873-2046
language eng
recordid cdi_proquest_journals_2581069418
source Elsevier ScienceDirect Journals
subjects Correlation analysis
Cost analysis
Customers
Data analysis
Datasets
Deterministic crowding
Evolutionary algorithms
Genetic algorithm
Genetic algorithms
Load consumption measurements
Low voltage
Missing data
Optimization
Phase identification
Studies
Substations
Transformer substation detection
title A new data-driven method based on Niching Genetic Algorithms for phase and substation identification
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T08%3A32%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20new%20data-driven%20method%20based%20on%20Niching%20Genetic%20Algorithms%20for%20phase%20and%20substation%20identification&rft.jtitle=Electric%20power%20systems%20research&rft.au=Jimenez,%20Victor%20Adrian&rft.date=2021-10&rft.volume=199&rft.spage=107434&rft.pages=107434-&rft.artnum=107434&rft.issn=0378-7796&rft.eissn=1873-2046&rft_id=info:doi/10.1016/j.epsr.2021.107434&rft_dat=%3Cproquest_cross%3E2581069418%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2581069418&rft_id=info:pmid/&rft_els_id=S0378779621004156&rfr_iscdi=true