Development of wide dynamic range beam loss monitor system for J-PARC main ring
The new beam loss monitor (BLM) system now in operation at the main ring of J- PARC consists of an isolated front-end current to voltage converter, a VME-based 24 bit ADC system. A dual detector system employs a proportional-type gas chamber (PBLM) and an air- filled ionization chamber (AIC). The sy...
Gespeichert in:
Veröffentlicht in: | Journal of physics. Conference series 2017-07, Vol.874 (1), p.12087 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 1 |
container_start_page | 12087 |
container_title | Journal of physics. Conference series |
container_volume | 874 |
creator | Satou, K Toyama, T Kamikubota, N Yamada, S Yoshida, S |
description | The new beam loss monitor (BLM) system now in operation at the main ring of J- PARC consists of an isolated front-end current to voltage converter, a VME-based 24 bit ADC system. A dual detector system employs a proportional-type gas chamber (PBLM) and an air- filled ionization chamber (AIC). The system shows a wide dynamic range of 160 dB. It can detect the low level signal that would arise in the case of the detection of residual dose in the ring itself after the beam has been turned off as well as an event such as high level beam loss at the collimators. The signal rise time of the waveform obtained is 17 µs which is fast enough to meet the speed requirement of the Machine Protection System (MPS); which is that the MPS should dump the beam within 100 µs when the beam loss signal exceeds the reference levels set in the ADC system. |
doi_str_mv | 10.1088/1742-6596/874/1/012087 |
format | Article |
fullrecord | <record><control><sourceid>proquest_iop_j</sourceid><recordid>TN_cdi_proquest_journals_2574612024</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2574612024</sourcerecordid><originalsourceid>FETCH-LOGICAL-c355t-ece89a7b0d9523762fbef60b6fd869ea9c504073432444a5a2f561e3e32727ff3</originalsourceid><addsrcrecordid>eNqFkFtLw0AQhRdRsFb_giz45EPM3nfzWOq1FFq8PC-bZLekNNm4SZX-e7dEKoLgvMzAnHNm-AC4xOgGI6VSLBlJBM9EqiRLcYowQUoegdFhcXyYlToFZ123RojGkiOwuLUfduPb2jY99A5-VqWF5a4xdVXAYJqVhbk1Ndz4roO1b6reB9jtut7W0MVxliwnz1NYm6qBoWpW5-DEmU1nL777GLzd371OH5P54uFpOpknBeW8T2xhVWZkjsqMEyoFcbl1AuXClUpk1mQFRwxJyihhjBluiOMCW2opkUQ6R8fgashtg3_f2q7Xa78NTTypCZdMRAaERZUYVEWI_wfrdBuq2oSdxkjv4ek9F71npCM8jfUALxrJYKx8-5P8r-n6D9NsOX35pdNt6egXMrh9HQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2574612024</pqid></control><display><type>article</type><title>Development of wide dynamic range beam loss monitor system for J-PARC main ring</title><source>IOP Publishing Free Content</source><source>EZB-FREE-00999 freely available EZB journals</source><source>IOPscience extra</source><source>Alma/SFX Local Collection</source><source>Free Full-Text Journals in Chemistry</source><creator>Satou, K ; Toyama, T ; Kamikubota, N ; Yamada, S ; Yoshida, S</creator><creatorcontrib>Satou, K ; Toyama, T ; Kamikubota, N ; Yamada, S ; Yoshida, S</creatorcontrib><description>The new beam loss monitor (BLM) system now in operation at the main ring of J- PARC consists of an isolated front-end current to voltage converter, a VME-based 24 bit ADC system. A dual detector system employs a proportional-type gas chamber (PBLM) and an air- filled ionization chamber (AIC). The system shows a wide dynamic range of 160 dB. It can detect the low level signal that would arise in the case of the detection of residual dose in the ring itself after the beam has been turned off as well as an event such as high level beam loss at the collimators. The signal rise time of the waveform obtained is 17 µs which is fast enough to meet the speed requirement of the Machine Protection System (MPS); which is that the MPS should dump the beam within 100 µs when the beam loss signal exceeds the reference levels set in the ADC system.</description><identifier>ISSN: 1742-6588</identifier><identifier>EISSN: 1742-6596</identifier><identifier>DOI: 10.1088/1742-6596/874/1/012087</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Collimators ; Dynamic range ; Ionization chambers ; Low level ; Physics ; Proton accelerators ; Voltage converters ; Waveforms</subject><ispartof>Journal of physics. Conference series, 2017-07, Vol.874 (1), p.12087</ispartof><rights>Published under licence by IOP Publishing Ltd</rights><rights>2017. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c355t-ece89a7b0d9523762fbef60b6fd869ea9c504073432444a5a2f561e3e32727ff3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1742-6596/874/1/012087/pdf$$EPDF$$P50$$Giop$$Hfree_for_read</linktopdf><link.rule.ids>314,780,784,27924,27925,38868,38890,53840,53867</link.rule.ids></links><search><creatorcontrib>Satou, K</creatorcontrib><creatorcontrib>Toyama, T</creatorcontrib><creatorcontrib>Kamikubota, N</creatorcontrib><creatorcontrib>Yamada, S</creatorcontrib><creatorcontrib>Yoshida, S</creatorcontrib><title>Development of wide dynamic range beam loss monitor system for J-PARC main ring</title><title>Journal of physics. Conference series</title><addtitle>J. Phys.: Conf. Ser</addtitle><description>The new beam loss monitor (BLM) system now in operation at the main ring of J- PARC consists of an isolated front-end current to voltage converter, a VME-based 24 bit ADC system. A dual detector system employs a proportional-type gas chamber (PBLM) and an air- filled ionization chamber (AIC). The system shows a wide dynamic range of 160 dB. It can detect the low level signal that would arise in the case of the detection of residual dose in the ring itself after the beam has been turned off as well as an event such as high level beam loss at the collimators. The signal rise time of the waveform obtained is 17 µs which is fast enough to meet the speed requirement of the Machine Protection System (MPS); which is that the MPS should dump the beam within 100 µs when the beam loss signal exceeds the reference levels set in the ADC system.</description><subject>Collimators</subject><subject>Dynamic range</subject><subject>Ionization chambers</subject><subject>Low level</subject><subject>Physics</subject><subject>Proton accelerators</subject><subject>Voltage converters</subject><subject>Waveforms</subject><issn>1742-6588</issn><issn>1742-6596</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>O3W</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqFkFtLw0AQhRdRsFb_giz45EPM3nfzWOq1FFq8PC-bZLekNNm4SZX-e7dEKoLgvMzAnHNm-AC4xOgGI6VSLBlJBM9EqiRLcYowQUoegdFhcXyYlToFZ123RojGkiOwuLUfduPb2jY99A5-VqWF5a4xdVXAYJqVhbk1Ndz4roO1b6reB9jtut7W0MVxliwnz1NYm6qBoWpW5-DEmU1nL777GLzd371OH5P54uFpOpknBeW8T2xhVWZkjsqMEyoFcbl1AuXClUpk1mQFRwxJyihhjBluiOMCW2opkUQ6R8fgashtg3_f2q7Xa78NTTypCZdMRAaERZUYVEWI_wfrdBuq2oSdxkjv4ek9F71npCM8jfUALxrJYKx8-5P8r-n6D9NsOX35pdNt6egXMrh9HQ</recordid><startdate>20170701</startdate><enddate>20170701</enddate><creator>Satou, K</creator><creator>Toyama, T</creator><creator>Kamikubota, N</creator><creator>Yamada, S</creator><creator>Yoshida, S</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>H8D</scope><scope>HCIFZ</scope><scope>L7M</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20170701</creationdate><title>Development of wide dynamic range beam loss monitor system for J-PARC main ring</title><author>Satou, K ; Toyama, T ; Kamikubota, N ; Yamada, S ; Yoshida, S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c355t-ece89a7b0d9523762fbef60b6fd869ea9c504073432444a5a2f561e3e32727ff3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Collimators</topic><topic>Dynamic range</topic><topic>Ionization chambers</topic><topic>Low level</topic><topic>Physics</topic><topic>Proton accelerators</topic><topic>Voltage converters</topic><topic>Waveforms</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Satou, K</creatorcontrib><creatorcontrib>Toyama, T</creatorcontrib><creatorcontrib>Kamikubota, N</creatorcontrib><creatorcontrib>Yamada, S</creatorcontrib><creatorcontrib>Yoshida, S</creatorcontrib><collection>IOP Publishing Free Content</collection><collection>IOPscience (Open Access)</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Aerospace Database</collection><collection>SciTech Premium Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Journal of physics. Conference series</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Satou, K</au><au>Toyama, T</au><au>Kamikubota, N</au><au>Yamada, S</au><au>Yoshida, S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of wide dynamic range beam loss monitor system for J-PARC main ring</atitle><jtitle>Journal of physics. Conference series</jtitle><addtitle>J. Phys.: Conf. Ser</addtitle><date>2017-07-01</date><risdate>2017</risdate><volume>874</volume><issue>1</issue><spage>12087</spage><pages>12087-</pages><issn>1742-6588</issn><eissn>1742-6596</eissn><abstract>The new beam loss monitor (BLM) system now in operation at the main ring of J- PARC consists of an isolated front-end current to voltage converter, a VME-based 24 bit ADC system. A dual detector system employs a proportional-type gas chamber (PBLM) and an air- filled ionization chamber (AIC). The system shows a wide dynamic range of 160 dB. It can detect the low level signal that would arise in the case of the detection of residual dose in the ring itself after the beam has been turned off as well as an event such as high level beam loss at the collimators. The signal rise time of the waveform obtained is 17 µs which is fast enough to meet the speed requirement of the Machine Protection System (MPS); which is that the MPS should dump the beam within 100 µs when the beam loss signal exceeds the reference levels set in the ADC system.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1742-6596/874/1/012087</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1742-6588 |
ispartof | Journal of physics. Conference series, 2017-07, Vol.874 (1), p.12087 |
issn | 1742-6588 1742-6596 |
language | eng |
recordid | cdi_proquest_journals_2574612024 |
source | IOP Publishing Free Content; EZB-FREE-00999 freely available EZB journals; IOPscience extra; Alma/SFX Local Collection; Free Full-Text Journals in Chemistry |
subjects | Collimators Dynamic range Ionization chambers Low level Physics Proton accelerators Voltage converters Waveforms |
title | Development of wide dynamic range beam loss monitor system for J-PARC main ring |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T23%3A06%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20wide%20dynamic%20range%20beam%20loss%20monitor%20system%20for%20J-PARC%20main%20ring&rft.jtitle=Journal%20of%20physics.%20Conference%20series&rft.au=Satou,%20K&rft.date=2017-07-01&rft.volume=874&rft.issue=1&rft.spage=12087&rft.pages=12087-&rft.issn=1742-6588&rft.eissn=1742-6596&rft_id=info:doi/10.1088/1742-6596/874/1/012087&rft_dat=%3Cproquest_iop_j%3E2574612024%3C/proquest_iop_j%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2574612024&rft_id=info:pmid/&rfr_iscdi=true |