The Effect of Deflector Angle in Savonius Water Turbine with Horizontal Axis on the Power Output of Water Flow in Pipe

Savonius turbine is one type of turbines with simple design and low manufacture. However, this turbine has a relatively low efficiency. This condition can be solved by installing fluid deflectors in the system's circuit. The deflector is used to direct the focus of the water flow, thus increasi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of physics. Conference series 2018-03, Vol.979 (1), p.12043
Hauptverfasser: Prasetyo, Ari, Kristiawan, Budi, Danardono, Dominicus, Hadi, Syamsul
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page 12043
container_title Journal of physics. Conference series
container_volume 979
creator Prasetyo, Ari
Kristiawan, Budi
Danardono, Dominicus
Hadi, Syamsul
description Savonius turbine is one type of turbines with simple design and low manufacture. However, this turbine has a relatively low efficiency. This condition can be solved by installing fluid deflectors in the system's circuit. The deflector is used to direct the focus of the water flow, thus increasing the torque working moment. In this study, a single stage horizontal axis Savonius water turbine was installed on a 3 inch diameter pipeline. This experiment aims to obtain optimal deflector angle design on each water discharge level. The deflector performance is analyzed through power output, TSR, and power coefficient generated by the turbine. The deflector angles tested are without deflector, 20°, 30°, 40°, and 50° with a deflector ratio of 50%. The experimental results at 10.67x10−3m3/s discharge show that turbine equipped with 30° deflector has the most optimal performance of 18.04 Watt power output, TSR of 1.12 and power coefficient 0.127. While with the same discharge, turbine without deflector produces only 9.77 Watt power output, TSR of 0.93, and power coefficient of 0.09. Thus, it can be concluded that the deflector increases power output equal to 85%.
doi_str_mv 10.1088/1742-6596/979/1/012043
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2572084682</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2572084682</sourcerecordid><originalsourceid>FETCH-LOGICAL-c408t-e38a595f36d4f0032f8ece818461b110145f7961685a151689905c7068cd14373</originalsourceid><addsrcrecordid>eNqFkNFKwzAUhoMoOKevIAGvvKhN2iZNL8fcnDLYYBMvQ9clLqM2NUk39elNrUwEwdycA_nOdw4_AJcY3WDEWIjTJAooyWiYpVmIQ4QjlMRHoHf4OD70jJ2CM2u3CMX-pT2wW24EHEkpCge1hLdClr7VBg6q51JAVcFFvtOVaix8yp0wcNmYlaoE3Cu3gRNt1IeuXF7CwZuyUFfQed9c7z05a1zdfFm7yXGp961wrmpxDk5kXlpx8V374HE8Wg4nwXR2dz8cTIMiQcwFImY5yYiM6TqR_uZIMlEIhllC8QpjhBMi04xiykiOiS9ZhkiRIsqKNU7iNO6Dq85bG_3aCOv4Vjem8it5RNIIeRGLPEU7qjDaWiMkr416yc07x4i3GfM2Pt5GyX3GHPMuYz943Q0qXf-YH-bDxS-O12vp2egP9p8Fn244iXM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2572084682</pqid></control><display><type>article</type><title>The Effect of Deflector Angle in Savonius Water Turbine with Horizontal Axis on the Power Output of Water Flow in Pipe</title><source>Institute of Physics Open Access Journal Titles</source><source>EZB-FREE-00999 freely available EZB journals</source><source>IOPscience extra</source><source>Alma/SFX Local Collection</source><source>Free Full-Text Journals in Chemistry</source><creator>Prasetyo, Ari ; Kristiawan, Budi ; Danardono, Dominicus ; Hadi, Syamsul</creator><creatorcontrib>Prasetyo, Ari ; Kristiawan, Budi ; Danardono, Dominicus ; Hadi, Syamsul</creatorcontrib><description>Savonius turbine is one type of turbines with simple design and low manufacture. However, this turbine has a relatively low efficiency. This condition can be solved by installing fluid deflectors in the system's circuit. The deflector is used to direct the focus of the water flow, thus increasing the torque working moment. In this study, a single stage horizontal axis Savonius water turbine was installed on a 3 inch diameter pipeline. This experiment aims to obtain optimal deflector angle design on each water discharge level. The deflector performance is analyzed through power output, TSR, and power coefficient generated by the turbine. The deflector angles tested are without deflector, 20°, 30°, 40°, and 50° with a deflector ratio of 50%. The experimental results at 10.67x10−3m3/s discharge show that turbine equipped with 30° deflector has the most optimal performance of 18.04 Watt power output, TSR of 1.12 and power coefficient 0.127. While with the same discharge, turbine without deflector produces only 9.77 Watt power output, TSR of 0.93, and power coefficient of 0.09. Thus, it can be concluded that the deflector increases power output equal to 85%.</description><identifier>ISSN: 1742-6588</identifier><identifier>EISSN: 1742-6596</identifier><identifier>DOI: 10.1088/1742-6596/979/1/012043</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Circuits ; Coefficients ; Deflectors ; Hydraulic turbines ; Physics ; Turbines ; Water discharge ; Water flow</subject><ispartof>Journal of physics. Conference series, 2018-03, Vol.979 (1), p.12043</ispartof><rights>Published under licence by IOP Publishing Ltd</rights><rights>2018. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c408t-e38a595f36d4f0032f8ece818461b110145f7961685a151689905c7068cd14373</citedby><cites>FETCH-LOGICAL-c408t-e38a595f36d4f0032f8ece818461b110145f7961685a151689905c7068cd14373</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1742-6596/979/1/012043/pdf$$EPDF$$P50$$Giop$$Hfree_for_read</linktopdf><link.rule.ids>315,781,785,27929,27930,38873,38895,53845,53872</link.rule.ids></links><search><creatorcontrib>Prasetyo, Ari</creatorcontrib><creatorcontrib>Kristiawan, Budi</creatorcontrib><creatorcontrib>Danardono, Dominicus</creatorcontrib><creatorcontrib>Hadi, Syamsul</creatorcontrib><title>The Effect of Deflector Angle in Savonius Water Turbine with Horizontal Axis on the Power Output of Water Flow in Pipe</title><title>Journal of physics. Conference series</title><addtitle>J. Phys.: Conf. Ser</addtitle><description>Savonius turbine is one type of turbines with simple design and low manufacture. However, this turbine has a relatively low efficiency. This condition can be solved by installing fluid deflectors in the system's circuit. The deflector is used to direct the focus of the water flow, thus increasing the torque working moment. In this study, a single stage horizontal axis Savonius water turbine was installed on a 3 inch diameter pipeline. This experiment aims to obtain optimal deflector angle design on each water discharge level. The deflector performance is analyzed through power output, TSR, and power coefficient generated by the turbine. The deflector angles tested are without deflector, 20°, 30°, 40°, and 50° with a deflector ratio of 50%. The experimental results at 10.67x10−3m3/s discharge show that turbine equipped with 30° deflector has the most optimal performance of 18.04 Watt power output, TSR of 1.12 and power coefficient 0.127. While with the same discharge, turbine without deflector produces only 9.77 Watt power output, TSR of 0.93, and power coefficient of 0.09. Thus, it can be concluded that the deflector increases power output equal to 85%.</description><subject>Circuits</subject><subject>Coefficients</subject><subject>Deflectors</subject><subject>Hydraulic turbines</subject><subject>Physics</subject><subject>Turbines</subject><subject>Water discharge</subject><subject>Water flow</subject><issn>1742-6588</issn><issn>1742-6596</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>O3W</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqFkNFKwzAUhoMoOKevIAGvvKhN2iZNL8fcnDLYYBMvQ9clLqM2NUk39elNrUwEwdycA_nOdw4_AJcY3WDEWIjTJAooyWiYpVmIQ4QjlMRHoHf4OD70jJ2CM2u3CMX-pT2wW24EHEkpCge1hLdClr7VBg6q51JAVcFFvtOVaix8yp0wcNmYlaoE3Cu3gRNt1IeuXF7CwZuyUFfQed9c7z05a1zdfFm7yXGp961wrmpxDk5kXlpx8V374HE8Wg4nwXR2dz8cTIMiQcwFImY5yYiM6TqR_uZIMlEIhllC8QpjhBMi04xiykiOiS9ZhkiRIsqKNU7iNO6Dq85bG_3aCOv4Vjem8it5RNIIeRGLPEU7qjDaWiMkr416yc07x4i3GfM2Pt5GyX3GHPMuYz943Q0qXf-YH-bDxS-O12vp2egP9p8Fn244iXM</recordid><startdate>20180301</startdate><enddate>20180301</enddate><creator>Prasetyo, Ari</creator><creator>Kristiawan, Budi</creator><creator>Danardono, Dominicus</creator><creator>Hadi, Syamsul</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>H8D</scope><scope>HCIFZ</scope><scope>L7M</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20180301</creationdate><title>The Effect of Deflector Angle in Savonius Water Turbine with Horizontal Axis on the Power Output of Water Flow in Pipe</title><author>Prasetyo, Ari ; Kristiawan, Budi ; Danardono, Dominicus ; Hadi, Syamsul</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c408t-e38a595f36d4f0032f8ece818461b110145f7961685a151689905c7068cd14373</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Circuits</topic><topic>Coefficients</topic><topic>Deflectors</topic><topic>Hydraulic turbines</topic><topic>Physics</topic><topic>Turbines</topic><topic>Water discharge</topic><topic>Water flow</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Prasetyo, Ari</creatorcontrib><creatorcontrib>Kristiawan, Budi</creatorcontrib><creatorcontrib>Danardono, Dominicus</creatorcontrib><creatorcontrib>Hadi, Syamsul</creatorcontrib><collection>Institute of Physics Open Access Journal Titles</collection><collection>IOPscience (Open Access)</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Aerospace Database</collection><collection>SciTech Premium Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Advanced Technologies &amp; Aerospace Database</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Journal of physics. Conference series</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Prasetyo, Ari</au><au>Kristiawan, Budi</au><au>Danardono, Dominicus</au><au>Hadi, Syamsul</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Effect of Deflector Angle in Savonius Water Turbine with Horizontal Axis on the Power Output of Water Flow in Pipe</atitle><jtitle>Journal of physics. Conference series</jtitle><addtitle>J. Phys.: Conf. Ser</addtitle><date>2018-03-01</date><risdate>2018</risdate><volume>979</volume><issue>1</issue><spage>12043</spage><pages>12043-</pages><issn>1742-6588</issn><eissn>1742-6596</eissn><abstract>Savonius turbine is one type of turbines with simple design and low manufacture. However, this turbine has a relatively low efficiency. This condition can be solved by installing fluid deflectors in the system's circuit. The deflector is used to direct the focus of the water flow, thus increasing the torque working moment. In this study, a single stage horizontal axis Savonius water turbine was installed on a 3 inch diameter pipeline. This experiment aims to obtain optimal deflector angle design on each water discharge level. The deflector performance is analyzed through power output, TSR, and power coefficient generated by the turbine. The deflector angles tested are without deflector, 20°, 30°, 40°, and 50° with a deflector ratio of 50%. The experimental results at 10.67x10−3m3/s discharge show that turbine equipped with 30° deflector has the most optimal performance of 18.04 Watt power output, TSR of 1.12 and power coefficient 0.127. While with the same discharge, turbine without deflector produces only 9.77 Watt power output, TSR of 0.93, and power coefficient of 0.09. Thus, it can be concluded that the deflector increases power output equal to 85%.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1742-6596/979/1/012043</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1742-6588
ispartof Journal of physics. Conference series, 2018-03, Vol.979 (1), p.12043
issn 1742-6588
1742-6596
language eng
recordid cdi_proquest_journals_2572084682
source Institute of Physics Open Access Journal Titles; EZB-FREE-00999 freely available EZB journals; IOPscience extra; Alma/SFX Local Collection; Free Full-Text Journals in Chemistry
subjects Circuits
Coefficients
Deflectors
Hydraulic turbines
Physics
Turbines
Water discharge
Water flow
title The Effect of Deflector Angle in Savonius Water Turbine with Horizontal Axis on the Power Output of Water Flow in Pipe
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-11T13%3A36%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Effect%20of%20Deflector%20Angle%20in%20Savonius%20Water%20Turbine%20with%20Horizontal%20Axis%20on%20the%20Power%20Output%20of%20Water%20Flow%20in%20Pipe&rft.jtitle=Journal%20of%20physics.%20Conference%20series&rft.au=Prasetyo,%20Ari&rft.date=2018-03-01&rft.volume=979&rft.issue=1&rft.spage=12043&rft.pages=12043-&rft.issn=1742-6588&rft.eissn=1742-6596&rft_id=info:doi/10.1088/1742-6596/979/1/012043&rft_dat=%3Cproquest_cross%3E2572084682%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2572084682&rft_id=info:pmid/&rfr_iscdi=true