A low-cost Holter monitor design equipped with external memory and Bluetooth connection

Monitoring the heart activity is critical for a patient with heart disease. Twenty-hour detecting of the ECG signal will help the clinician to diagnose the hearth. This device is usually called a Holter monitor. However, the price of this device is very expensive, therefore the development of a Holt...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IOP conference series. Materials Science and Engineering 2020-05, Vol.850 (1), p.12020
Hauptverfasser: Nofitasari, D, Wisana, I D G H, Triwiyanto, T, Setioningsih, E D, Mak'ruf, M R, Nugraha, P C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page 12020
container_title IOP conference series. Materials Science and Engineering
container_volume 850
creator Nofitasari, D
Wisana, I D G H
Triwiyanto, T
Setioningsih, E D
Mak'ruf, M R
Nugraha, P C
description Monitoring the heart activity is critical for a patient with heart disease. Twenty-hour detecting of the ECG signal will help the clinician to diagnose the hearth. This device is usually called a Holter monitor. However, the price of this device is very expensive, therefore the development of a Holter is required. The purpose of this study is to develop a portable and low-cost Holter system to record the ECG signal in twenty-four hours. The mainboard is composed of a pre-amplifier, bandpass filter, notch filter, summing amplifier, Arduino microcontroller, SD Card Memory, and a Bluetooth transmitter. ECG signal is collected from the body based on the standard measurement of LEAD II. The ECG signal is sampled with a frequency sampling of 200 Hz. To record the raw data of the ECG signal, the SD Card Memory was used to save the data for further data analysis. Calibration was conducted by using an ECG phantom. The calibration was performed in order to make this design to be a standard ECG machine. The design was also equipped with a Bluetooth transmitter to transmit the data to the computer. The total price to develop this device is 460,000 IDR. After the evaluation, the BPM error of this Holter is ±0.0273% and the Holter able to operate in 24 hours. The developed ECG Holter is portable in dimension and low cost to be fabricated for mass production to help people with heart disease.
doi_str_mv 10.1088/1757-899X/850/1/012020
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2562481948</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2562481948</sourcerecordid><originalsourceid>FETCH-LOGICAL-c407t-d6e0aa9126dd5ef10ec74dea1852b7edaf020d4f66331edf05eb8e9e2e55271c3</originalsourceid><addsrcrecordid>eNqFkFFLwzAQx4MoOKdfQQK--FKbZE2bPs6xOWHig4q-hay5akfbdEnK3Le3pTIRBJ_u4H735-6H0CUlN5QIEdKEJ4FI07dQcBLSkFBGGDlCo8Pg-NALeorOnNsQEidRREbodYpLswsy4zxemtKDxZWpC28s1uCK9xrDti2aBjTeFf4Dw2eH1KrEFVTG7rGqNb4tW_DGdNPM1DVkvjD1OTrJVeng4ruO0cti_jxbBqvHu_vZdBVkEUl8oGMgSqWUxVpzyCmBLIk0KCo4WyegVd69oqM8jicTCjonHNYCUmDAOUtoNhmjqyG3sWbbgvNyY9r-QCcZj1kkaBqJjooHKrPGOQu5bGxRKbuXlMheouz9yN6V7CRKKgeJ3eL1sFiY5if54Wn-C5ONzjuU_YH-k_8FzPOCqA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2562481948</pqid></control><display><type>article</type><title>A low-cost Holter monitor design equipped with external memory and Bluetooth connection</title><source>Institute of Physics Open Access Journal Titles</source><source>Institute of Physics IOPscience extra</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Free Full-Text Journals in Chemistry</source><creator>Nofitasari, D ; Wisana, I D G H ; Triwiyanto, T ; Setioningsih, E D ; Mak'ruf, M R ; Nugraha, P C</creator><creatorcontrib>Nofitasari, D ; Wisana, I D G H ; Triwiyanto, T ; Setioningsih, E D ; Mak'ruf, M R ; Nugraha, P C</creatorcontrib><description>Monitoring the heart activity is critical for a patient with heart disease. Twenty-hour detecting of the ECG signal will help the clinician to diagnose the hearth. This device is usually called a Holter monitor. However, the price of this device is very expensive, therefore the development of a Holter is required. The purpose of this study is to develop a portable and low-cost Holter system to record the ECG signal in twenty-four hours. The mainboard is composed of a pre-amplifier, bandpass filter, notch filter, summing amplifier, Arduino microcontroller, SD Card Memory, and a Bluetooth transmitter. ECG signal is collected from the body based on the standard measurement of LEAD II. The ECG signal is sampled with a frequency sampling of 200 Hz. To record the raw data of the ECG signal, the SD Card Memory was used to save the data for further data analysis. Calibration was conducted by using an ECG phantom. The calibration was performed in order to make this design to be a standard ECG machine. The design was also equipped with a Bluetooth transmitter to transmit the data to the computer. The total price to develop this device is 460,000 IDR. After the evaluation, the BPM error of this Holter is ±0.0273% and the Holter able to operate in 24 hours. The developed ECG Holter is portable in dimension and low cost to be fabricated for mass production to help people with heart disease.</description><identifier>ISSN: 1757-8981</identifier><identifier>EISSN: 1757-899X</identifier><identifier>DOI: 10.1088/1757-899X/850/1/012020</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Amplifiers ; Bandpass filters ; Bluetooth ; Calibration ; Cardiovascular disease ; Data analysis ; Design standards ; Heart diseases ; Low cost ; Mass production ; Microcontrollers ; Motherboards ; Notch filters</subject><ispartof>IOP conference series. Materials Science and Engineering, 2020-05, Vol.850 (1), p.12020</ispartof><rights>Published under licence by IOP Publishing Ltd</rights><rights>2020. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c407t-d6e0aa9126dd5ef10ec74dea1852b7edaf020d4f66331edf05eb8e9e2e55271c3</citedby><cites>FETCH-LOGICAL-c407t-d6e0aa9126dd5ef10ec74dea1852b7edaf020d4f66331edf05eb8e9e2e55271c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1757-899X/850/1/012020/pdf$$EPDF$$P50$$Giop$$Hfree_for_read</linktopdf><link.rule.ids>314,780,784,27924,27925,38868,38890,53840,53867</link.rule.ids></links><search><creatorcontrib>Nofitasari, D</creatorcontrib><creatorcontrib>Wisana, I D G H</creatorcontrib><creatorcontrib>Triwiyanto, T</creatorcontrib><creatorcontrib>Setioningsih, E D</creatorcontrib><creatorcontrib>Mak'ruf, M R</creatorcontrib><creatorcontrib>Nugraha, P C</creatorcontrib><title>A low-cost Holter monitor design equipped with external memory and Bluetooth connection</title><title>IOP conference series. Materials Science and Engineering</title><addtitle>IOP Conf. Ser.: Mater. Sci. Eng</addtitle><description>Monitoring the heart activity is critical for a patient with heart disease. Twenty-hour detecting of the ECG signal will help the clinician to diagnose the hearth. This device is usually called a Holter monitor. However, the price of this device is very expensive, therefore the development of a Holter is required. The purpose of this study is to develop a portable and low-cost Holter system to record the ECG signal in twenty-four hours. The mainboard is composed of a pre-amplifier, bandpass filter, notch filter, summing amplifier, Arduino microcontroller, SD Card Memory, and a Bluetooth transmitter. ECG signal is collected from the body based on the standard measurement of LEAD II. The ECG signal is sampled with a frequency sampling of 200 Hz. To record the raw data of the ECG signal, the SD Card Memory was used to save the data for further data analysis. Calibration was conducted by using an ECG phantom. The calibration was performed in order to make this design to be a standard ECG machine. The design was also equipped with a Bluetooth transmitter to transmit the data to the computer. The total price to develop this device is 460,000 IDR. After the evaluation, the BPM error of this Holter is ±0.0273% and the Holter able to operate in 24 hours. The developed ECG Holter is portable in dimension and low cost to be fabricated for mass production to help people with heart disease.</description><subject>Amplifiers</subject><subject>Bandpass filters</subject><subject>Bluetooth</subject><subject>Calibration</subject><subject>Cardiovascular disease</subject><subject>Data analysis</subject><subject>Design standards</subject><subject>Heart diseases</subject><subject>Low cost</subject><subject>Mass production</subject><subject>Microcontrollers</subject><subject>Motherboards</subject><subject>Notch filters</subject><issn>1757-8981</issn><issn>1757-899X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>O3W</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqFkFFLwzAQx4MoOKdfQQK--FKbZE2bPs6xOWHig4q-hay5akfbdEnK3Le3pTIRBJ_u4H735-6H0CUlN5QIEdKEJ4FI07dQcBLSkFBGGDlCo8Pg-NALeorOnNsQEidRREbodYpLswsy4zxemtKDxZWpC28s1uCK9xrDti2aBjTeFf4Dw2eH1KrEFVTG7rGqNb4tW_DGdNPM1DVkvjD1OTrJVeng4ruO0cti_jxbBqvHu_vZdBVkEUl8oGMgSqWUxVpzyCmBLIk0KCo4WyegVd69oqM8jicTCjonHNYCUmDAOUtoNhmjqyG3sWbbgvNyY9r-QCcZj1kkaBqJjooHKrPGOQu5bGxRKbuXlMheouz9yN6V7CRKKgeJ3eL1sFiY5if54Wn-C5ONzjuU_YH-k_8FzPOCqA</recordid><startdate>20200501</startdate><enddate>20200501</enddate><creator>Nofitasari, D</creator><creator>Wisana, I D G H</creator><creator>Triwiyanto, T</creator><creator>Setioningsih, E D</creator><creator>Mak'ruf, M R</creator><creator>Nugraha, P C</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>KB.</scope><scope>L6V</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PTHSS</scope></search><sort><creationdate>20200501</creationdate><title>A low-cost Holter monitor design equipped with external memory and Bluetooth connection</title><author>Nofitasari, D ; Wisana, I D G H ; Triwiyanto, T ; Setioningsih, E D ; Mak'ruf, M R ; Nugraha, P C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c407t-d6e0aa9126dd5ef10ec74dea1852b7edaf020d4f66331edf05eb8e9e2e55271c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Amplifiers</topic><topic>Bandpass filters</topic><topic>Bluetooth</topic><topic>Calibration</topic><topic>Cardiovascular disease</topic><topic>Data analysis</topic><topic>Design standards</topic><topic>Heart diseases</topic><topic>Low cost</topic><topic>Mass production</topic><topic>Microcontrollers</topic><topic>Motherboards</topic><topic>Notch filters</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nofitasari, D</creatorcontrib><creatorcontrib>Wisana, I D G H</creatorcontrib><creatorcontrib>Triwiyanto, T</creatorcontrib><creatorcontrib>Setioningsih, E D</creatorcontrib><creatorcontrib>Mak'ruf, M R</creatorcontrib><creatorcontrib>Nugraha, P C</creatorcontrib><collection>Institute of Physics Open Access Journal Titles</collection><collection>IOPscience (Open Access)</collection><collection>CrossRef</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>Materials Science Database</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>Engineering Collection</collection><jtitle>IOP conference series. Materials Science and Engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nofitasari, D</au><au>Wisana, I D G H</au><au>Triwiyanto, T</au><au>Setioningsih, E D</au><au>Mak'ruf, M R</au><au>Nugraha, P C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A low-cost Holter monitor design equipped with external memory and Bluetooth connection</atitle><jtitle>IOP conference series. Materials Science and Engineering</jtitle><addtitle>IOP Conf. Ser.: Mater. Sci. Eng</addtitle><date>2020-05-01</date><risdate>2020</risdate><volume>850</volume><issue>1</issue><spage>12020</spage><pages>12020-</pages><issn>1757-8981</issn><eissn>1757-899X</eissn><abstract>Monitoring the heart activity is critical for a patient with heart disease. Twenty-hour detecting of the ECG signal will help the clinician to diagnose the hearth. This device is usually called a Holter monitor. However, the price of this device is very expensive, therefore the development of a Holter is required. The purpose of this study is to develop a portable and low-cost Holter system to record the ECG signal in twenty-four hours. The mainboard is composed of a pre-amplifier, bandpass filter, notch filter, summing amplifier, Arduino microcontroller, SD Card Memory, and a Bluetooth transmitter. ECG signal is collected from the body based on the standard measurement of LEAD II. The ECG signal is sampled with a frequency sampling of 200 Hz. To record the raw data of the ECG signal, the SD Card Memory was used to save the data for further data analysis. Calibration was conducted by using an ECG phantom. The calibration was performed in order to make this design to be a standard ECG machine. The design was also equipped with a Bluetooth transmitter to transmit the data to the computer. The total price to develop this device is 460,000 IDR. After the evaluation, the BPM error of this Holter is ±0.0273% and the Holter able to operate in 24 hours. The developed ECG Holter is portable in dimension and low cost to be fabricated for mass production to help people with heart disease.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1757-899X/850/1/012020</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1757-8981
ispartof IOP conference series. Materials Science and Engineering, 2020-05, Vol.850 (1), p.12020
issn 1757-8981
1757-899X
language eng
recordid cdi_proquest_journals_2562481948
source Institute of Physics Open Access Journal Titles; Institute of Physics IOPscience extra; EZB-FREE-00999 freely available EZB journals; Free Full-Text Journals in Chemistry
subjects Amplifiers
Bandpass filters
Bluetooth
Calibration
Cardiovascular disease
Data analysis
Design standards
Heart diseases
Low cost
Mass production
Microcontrollers
Motherboards
Notch filters
title A low-cost Holter monitor design equipped with external memory and Bluetooth connection
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T17%3A33%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20low-cost%20Holter%20monitor%20design%20equipped%20with%20external%20memory%20and%20Bluetooth%20connection&rft.jtitle=IOP%20conference%20series.%20Materials%20Science%20and%20Engineering&rft.au=Nofitasari,%20D&rft.date=2020-05-01&rft.volume=850&rft.issue=1&rft.spage=12020&rft.pages=12020-&rft.issn=1757-8981&rft.eissn=1757-899X&rft_id=info:doi/10.1088/1757-899X/850/1/012020&rft_dat=%3Cproquest_cross%3E2562481948%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2562481948&rft_id=info:pmid/&rfr_iscdi=true