Calculating the maximum penetration capacity of distributed generation considering current protection

With significant increasing penetration of the inverter interfaced distributed generations(IIDG), the radial network turns into a multipower-supply network. Working as an additional source, IIDG may increase the total fault level and altering the magnitude and direction of the fault current, which c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IOP conference series. Earth and environmental science 2018-10, Vol.186 (4), p.12034
Hauptverfasser: Deng, Jingsong, Wang, Yingming, Sun, Difei, Zheng, Chenling, Yan, Hanting, Gao, Xiaojing
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 4
container_start_page 12034
container_title IOP conference series. Earth and environmental science
container_volume 186
creator Deng, Jingsong
Wang, Yingming
Sun, Difei
Zheng, Chenling
Yan, Hanting
Gao, Xiaojing
description With significant increasing penetration of the inverter interfaced distributed generations(IIDG), the radial network turns into a multipower-supply network. Working as an additional source, IIDG may increase the total fault level and altering the magnitude and direction of the fault current, which compromise the correct operation of the overcurrent protection system. This paper presents a new method to calculate the optimal allocation of IIDG without any amendment of protection settings, which will make great convenience for operators to review the accessible capacity of IIDG reported by users. Under the consideration of low voltage ride through(LVRT), the method uses iterative correction to figure out the nonlinear relationship between the fault current of IIDG and the fault voltage of the point of common coupling(PCC) in order to get the optimal capacity which meets the constraints of the current protection's selectivity and sensitivity.
doi_str_mv 10.1088/1755-1315/186/4/012034
format Article
fullrecord <record><control><sourceid>proquest_iop_j</sourceid><recordid>TN_cdi_proquest_journals_2559495315</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2559495315</sourcerecordid><originalsourceid>FETCH-LOGICAL-c407t-60ef5f162ea571bb3c7baae725608efe3d7a61879ca751f7b8374b8329ed34d53</originalsourceid><addsrcrecordid>eNqFkE1LxDAQhoMouK7-BQl48VKbNE3THmVZP2DBg3oOaTpZs-y2NUnB_femVFcEwctkyDzzDjwIXVJyQ0lZplRwnlBGeUrLIs1TQjPC8iM0OwyODz0Rp-jM-w0hhchZNUOwUFs9bFWw7RqHN8A79WF3ww730EJw8b9rsVa90jbscWdwY31wth4CNHgdmW-ka71twI0xenAO2oB71wXQ4_gcnRi19XDx9c7R693yZfGQrJ7uHxe3q0TnRISkIGC4oUUGigta10yLWikQGS9ICQZYI1RBS1FpJTg1oi6ZyGPJKmhY3nA2R1dTbjz9PoAPctMNro0nZcZ5lVc82ohUMVHadd47MLJ3dqfcXlIiR6VytCVHczIqlbmclMbF62nRdv1P8nL5_AuTfWMimv2B_pP_CcMUh6c</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2559495315</pqid></control><display><type>article</type><title>Calculating the maximum penetration capacity of distributed generation considering current protection</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Institute of Physics Open Access Journal Titles</source><source>IOPscience extra</source><creator>Deng, Jingsong ; Wang, Yingming ; Sun, Difei ; Zheng, Chenling ; Yan, Hanting ; Gao, Xiaojing</creator><creatorcontrib>Deng, Jingsong ; Wang, Yingming ; Sun, Difei ; Zheng, Chenling ; Yan, Hanting ; Gao, Xiaojing</creatorcontrib><description>With significant increasing penetration of the inverter interfaced distributed generations(IIDG), the radial network turns into a multipower-supply network. Working as an additional source, IIDG may increase the total fault level and altering the magnitude and direction of the fault current, which compromise the correct operation of the overcurrent protection system. This paper presents a new method to calculate the optimal allocation of IIDG without any amendment of protection settings, which will make great convenience for operators to review the accessible capacity of IIDG reported by users. Under the consideration of low voltage ride through(LVRT), the method uses iterative correction to figure out the nonlinear relationship between the fault current of IIDG and the fault voltage of the point of common coupling(PCC) in order to get the optimal capacity which meets the constraints of the current protection's selectivity and sensitivity.</description><identifier>ISSN: 1755-1307</identifier><identifier>ISSN: 1755-1315</identifier><identifier>EISSN: 1755-1315</identifier><identifier>DOI: 10.1088/1755-1315/186/4/012034</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Distributed generation ; Low voltage ; Mathematical analysis ; Overcurrent ; Penetration ; Selectivity ; Voltage</subject><ispartof>IOP conference series. Earth and environmental science, 2018-10, Vol.186 (4), p.12034</ispartof><rights>Published under licence by IOP Publishing Ltd</rights><rights>2018. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c407t-60ef5f162ea571bb3c7baae725608efe3d7a61879ca751f7b8374b8329ed34d53</citedby><cites>FETCH-LOGICAL-c407t-60ef5f162ea571bb3c7baae725608efe3d7a61879ca751f7b8374b8329ed34d53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1755-1315/186/4/012034/pdf$$EPDF$$P50$$Giop$$Hfree_for_read</linktopdf><link.rule.ids>315,781,785,27929,27930,38873,38895,53845,53872</link.rule.ids></links><search><creatorcontrib>Deng, Jingsong</creatorcontrib><creatorcontrib>Wang, Yingming</creatorcontrib><creatorcontrib>Sun, Difei</creatorcontrib><creatorcontrib>Zheng, Chenling</creatorcontrib><creatorcontrib>Yan, Hanting</creatorcontrib><creatorcontrib>Gao, Xiaojing</creatorcontrib><title>Calculating the maximum penetration capacity of distributed generation considering current protection</title><title>IOP conference series. Earth and environmental science</title><addtitle>IOP Conf. Ser.: Earth Environ. Sci</addtitle><description>With significant increasing penetration of the inverter interfaced distributed generations(IIDG), the radial network turns into a multipower-supply network. Working as an additional source, IIDG may increase the total fault level and altering the magnitude and direction of the fault current, which compromise the correct operation of the overcurrent protection system. This paper presents a new method to calculate the optimal allocation of IIDG without any amendment of protection settings, which will make great convenience for operators to review the accessible capacity of IIDG reported by users. Under the consideration of low voltage ride through(LVRT), the method uses iterative correction to figure out the nonlinear relationship between the fault current of IIDG and the fault voltage of the point of common coupling(PCC) in order to get the optimal capacity which meets the constraints of the current protection's selectivity and sensitivity.</description><subject>Distributed generation</subject><subject>Low voltage</subject><subject>Mathematical analysis</subject><subject>Overcurrent</subject><subject>Penetration</subject><subject>Selectivity</subject><subject>Voltage</subject><issn>1755-1307</issn><issn>1755-1315</issn><issn>1755-1315</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>O3W</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNqFkE1LxDAQhoMouK7-BQl48VKbNE3THmVZP2DBg3oOaTpZs-y2NUnB_femVFcEwctkyDzzDjwIXVJyQ0lZplRwnlBGeUrLIs1TQjPC8iM0OwyODz0Rp-jM-w0hhchZNUOwUFs9bFWw7RqHN8A79WF3ww730EJw8b9rsVa90jbscWdwY31wth4CNHgdmW-ka71twI0xenAO2oB71wXQ4_gcnRi19XDx9c7R693yZfGQrJ7uHxe3q0TnRISkIGC4oUUGigta10yLWikQGS9ICQZYI1RBS1FpJTg1oi6ZyGPJKmhY3nA2R1dTbjz9PoAPctMNro0nZcZ5lVc82ohUMVHadd47MLJ3dqfcXlIiR6VytCVHczIqlbmclMbF62nRdv1P8nL5_AuTfWMimv2B_pP_CcMUh6c</recordid><startdate>20181011</startdate><enddate>20181011</enddate><creator>Deng, Jingsong</creator><creator>Wang, Yingming</creator><creator>Sun, Difei</creator><creator>Zheng, Chenling</creator><creator>Yan, Hanting</creator><creator>Gao, Xiaojing</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ATCPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>PATMY</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PYCSY</scope></search><sort><creationdate>20181011</creationdate><title>Calculating the maximum penetration capacity of distributed generation considering current protection</title><author>Deng, Jingsong ; Wang, Yingming ; Sun, Difei ; Zheng, Chenling ; Yan, Hanting ; Gao, Xiaojing</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c407t-60ef5f162ea571bb3c7baae725608efe3d7a61879ca751f7b8374b8329ed34d53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Distributed generation</topic><topic>Low voltage</topic><topic>Mathematical analysis</topic><topic>Overcurrent</topic><topic>Penetration</topic><topic>Selectivity</topic><topic>Voltage</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Deng, Jingsong</creatorcontrib><creatorcontrib>Wang, Yingming</creatorcontrib><creatorcontrib>Sun, Difei</creatorcontrib><creatorcontrib>Zheng, Chenling</creatorcontrib><creatorcontrib>Yan, Hanting</creatorcontrib><creatorcontrib>Gao, Xiaojing</creatorcontrib><collection>Institute of Physics Open Access Journal Titles</collection><collection>IOPscience (Open Access)</collection><collection>CrossRef</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Agricultural &amp; Environmental Science Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>Environmental Science Database</collection><collection>Access via ProQuest (Open Access)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Environmental Science Collection</collection><jtitle>IOP conference series. Earth and environmental science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Deng, Jingsong</au><au>Wang, Yingming</au><au>Sun, Difei</au><au>Zheng, Chenling</au><au>Yan, Hanting</au><au>Gao, Xiaojing</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calculating the maximum penetration capacity of distributed generation considering current protection</atitle><jtitle>IOP conference series. Earth and environmental science</jtitle><addtitle>IOP Conf. Ser.: Earth Environ. Sci</addtitle><date>2018-10-11</date><risdate>2018</risdate><volume>186</volume><issue>4</issue><spage>12034</spage><pages>12034-</pages><issn>1755-1307</issn><issn>1755-1315</issn><eissn>1755-1315</eissn><abstract>With significant increasing penetration of the inverter interfaced distributed generations(IIDG), the radial network turns into a multipower-supply network. Working as an additional source, IIDG may increase the total fault level and altering the magnitude and direction of the fault current, which compromise the correct operation of the overcurrent protection system. This paper presents a new method to calculate the optimal allocation of IIDG without any amendment of protection settings, which will make great convenience for operators to review the accessible capacity of IIDG reported by users. Under the consideration of low voltage ride through(LVRT), the method uses iterative correction to figure out the nonlinear relationship between the fault current of IIDG and the fault voltage of the point of common coupling(PCC) in order to get the optimal capacity which meets the constraints of the current protection's selectivity and sensitivity.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1755-1315/186/4/012034</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1755-1307
ispartof IOP conference series. Earth and environmental science, 2018-10, Vol.186 (4), p.12034
issn 1755-1307
1755-1315
1755-1315
language eng
recordid cdi_proquest_journals_2559495315
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Institute of Physics Open Access Journal Titles; IOPscience extra
subjects Distributed generation
Low voltage
Mathematical analysis
Overcurrent
Penetration
Selectivity
Voltage
title Calculating the maximum penetration capacity of distributed generation considering current protection
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-11T21%3A41%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calculating%20the%20maximum%20penetration%20capacity%20of%20distributed%20generation%20considering%20current%20protection&rft.jtitle=IOP%20conference%20series.%20Earth%20and%20environmental%20science&rft.au=Deng,%20Jingsong&rft.date=2018-10-11&rft.volume=186&rft.issue=4&rft.spage=12034&rft.pages=12034-&rft.issn=1755-1307&rft.eissn=1755-1315&rft_id=info:doi/10.1088/1755-1315/186/4/012034&rft_dat=%3Cproquest_iop_j%3E2559495315%3C/proquest_iop_j%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2559495315&rft_id=info:pmid/&rfr_iscdi=true