Calculation of Working Spaces Irradiation in the Steel-Melting Plant of Pjsc «Tagmet» at its Reconstruction by the Method of Construction of Epyures of Irradiation

With the growth of thermal capacity of the equipment, the tasks of designing new and modernizing existing thermal workshops, taking into account the safe working conditions of staff, are of great importance. However, there are often no experimental data for measuring irradiation and temperature of e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IOP conference series. Earth and environmental science 2019-01, Vol.224 (1), p.12052
Hauptverfasser: Bulygin, Y I, Azimova, N N, Kuptsova, I S, Popov, D S, Maslensky, V V
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page 12052
container_title IOP conference series. Earth and environmental science
container_volume 224
creator Bulygin, Y I
Azimova, N N
Kuptsova, I S
Popov, D S
Maslensky, V V
description With the growth of thermal capacity of the equipment, the tasks of designing new and modernizing existing thermal workshops, taking into account the safe working conditions of staff, are of great importance. However, there are often no experimental data for measuring irradiation and temperature of equipment and workplaces, and the results of a special assessment of working conditions are available only for existing industries and then the method of constructing radiation exposure diagrams comes to the rescue. The article presents the results of calculations of the exposure levels of open and closed workplaces, which showed that the sanitary and hygienic standard on the working area of the EAF-150 was significantly exceeded. Experimental studies of the temperature of the surfaces of the equipment placed on the working platform of DSP-150 showed that the requirements of sanitary and hygienic standards for temperature are met only on the outer wall of the furnace control panel, which is not acceptable. Thus, at the design stage of the steel-smelting shop, when modernizing the furnaces (switching to super-power furnaces DSP-150), the possible negative effects of radiation sources were not taken into account and the distance protection in the shop was practically not effective.
doi_str_mv 10.1088/1755-1315/224/1/012052
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2557500299</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2557500299</sourcerecordid><originalsourceid>FETCH-LOGICAL-c465t-7163b95312ef3ad1056d5fa3b098429b65baba7fa6d1bfcb4debfccc6fb930c23</originalsourceid><addsrcrecordid>eNqFUctKxDAULaLg-PgFCbhxU5tH006XUsYHKA7OiMuQpInTsTY1SRfzQa78BHd-me1URgXB1b2X84J7guAIwVMEx-MIpZSGiCAaYRxHKIIIQ4q3gtEG2N7sMN0N9pxbQpikMclGwWvOK9lW3JemBkaDB2OfyvoRzBoulQNX1vKiHNCyBn6hwMwrVYU3qvI9b1rx2vfC6dJJ8PE254_Pyn-8A-5B6R24U9LUzttWrj3Eau1xo_zCFL0s_4l296RZtbYL7tYf2QfBjuaVU4dfcz-4P5_M88vw-vbiKj-7DmWcUB-mKCEiowRhpQkvEKRJQTUnAmbjGGcioYILnmqeFEhoKeJCdUPKRIuMQInJfnA8-DbWvLTKebY0ra27SIYpTSmEOMs6VjKwpDXOWaVZY8tnblcMQdZXwvpvs_7zrKuEITZU0gnxICxN8-38r-jkD9FkMvtFY02hyScuQJ9q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2557500299</pqid></control><display><type>article</type><title>Calculation of Working Spaces Irradiation in the Steel-Melting Plant of Pjsc «Tagmet» at its Reconstruction by the Method of Construction of Epyures of Irradiation</title><source>IOP Publishing Free Content</source><source>EZB-FREE-00999 freely available EZB journals</source><source>IOPscience extra</source><creator>Bulygin, Y I ; Azimova, N N ; Kuptsova, I S ; Popov, D S ; Maslensky, V V</creator><creatorcontrib>Bulygin, Y I ; Azimova, N N ; Kuptsova, I S ; Popov, D S ; Maslensky, V V</creatorcontrib><description>With the growth of thermal capacity of the equipment, the tasks of designing new and modernizing existing thermal workshops, taking into account the safe working conditions of staff, are of great importance. However, there are often no experimental data for measuring irradiation and temperature of equipment and workplaces, and the results of a special assessment of working conditions are available only for existing industries and then the method of constructing radiation exposure diagrams comes to the rescue. The article presents the results of calculations of the exposure levels of open and closed workplaces, which showed that the sanitary and hygienic standard on the working area of the EAF-150 was significantly exceeded. Experimental studies of the temperature of the surfaces of the equipment placed on the working platform of DSP-150 showed that the requirements of sanitary and hygienic standards for temperature are met only on the outer wall of the furnace control panel, which is not acceptable. Thus, at the design stage of the steel-smelting shop, when modernizing the furnaces (switching to super-power furnaces DSP-150), the possible negative effects of radiation sources were not taken into account and the distance protection in the shop was practically not effective.</description><identifier>ISSN: 1755-1307</identifier><identifier>ISSN: 1755-1315</identifier><identifier>EISSN: 1755-1315</identifier><identifier>DOI: 10.1088/1755-1315/224/1/012052</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Control boards ; Furnaces ; Hygiene ; Irradiation ; Mathematical analysis ; Modernization ; Radiation ; Radiation effects ; Radiation sources ; Temperature requirements ; Thermal capacity ; Working conditions ; Workplaces</subject><ispartof>IOP conference series. Earth and environmental science, 2019-01, Vol.224 (1), p.12052</ispartof><rights>Published under licence by IOP Publishing Ltd</rights><rights>2019. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c465t-7163b95312ef3ad1056d5fa3b098429b65baba7fa6d1bfcb4debfccc6fb930c23</citedby><cites>FETCH-LOGICAL-c465t-7163b95312ef3ad1056d5fa3b098429b65baba7fa6d1bfcb4debfccc6fb930c23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1755-1315/224/1/012052/pdf$$EPDF$$P50$$Giop$$Hfree_for_read</linktopdf><link.rule.ids>314,777,781,27905,27906,38849,38871,53821,53848</link.rule.ids></links><search><creatorcontrib>Bulygin, Y I</creatorcontrib><creatorcontrib>Azimova, N N</creatorcontrib><creatorcontrib>Kuptsova, I S</creatorcontrib><creatorcontrib>Popov, D S</creatorcontrib><creatorcontrib>Maslensky, V V</creatorcontrib><title>Calculation of Working Spaces Irradiation in the Steel-Melting Plant of Pjsc «Tagmet» at its Reconstruction by the Method of Construction of Epyures of Irradiation</title><title>IOP conference series. Earth and environmental science</title><addtitle>IOP Conf. Ser.: Earth Environ. Sci</addtitle><description>With the growth of thermal capacity of the equipment, the tasks of designing new and modernizing existing thermal workshops, taking into account the safe working conditions of staff, are of great importance. However, there are often no experimental data for measuring irradiation and temperature of equipment and workplaces, and the results of a special assessment of working conditions are available only for existing industries and then the method of constructing radiation exposure diagrams comes to the rescue. The article presents the results of calculations of the exposure levels of open and closed workplaces, which showed that the sanitary and hygienic standard on the working area of the EAF-150 was significantly exceeded. Experimental studies of the temperature of the surfaces of the equipment placed on the working platform of DSP-150 showed that the requirements of sanitary and hygienic standards for temperature are met only on the outer wall of the furnace control panel, which is not acceptable. Thus, at the design stage of the steel-smelting shop, when modernizing the furnaces (switching to super-power furnaces DSP-150), the possible negative effects of radiation sources were not taken into account and the distance protection in the shop was practically not effective.</description><subject>Control boards</subject><subject>Furnaces</subject><subject>Hygiene</subject><subject>Irradiation</subject><subject>Mathematical analysis</subject><subject>Modernization</subject><subject>Radiation</subject><subject>Radiation effects</subject><subject>Radiation sources</subject><subject>Temperature requirements</subject><subject>Thermal capacity</subject><subject>Working conditions</subject><subject>Workplaces</subject><issn>1755-1307</issn><issn>1755-1315</issn><issn>1755-1315</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>O3W</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNqFUctKxDAULaLg-PgFCbhxU5tH006XUsYHKA7OiMuQpInTsTY1SRfzQa78BHd-me1URgXB1b2X84J7guAIwVMEx-MIpZSGiCAaYRxHKIIIQ4q3gtEG2N7sMN0N9pxbQpikMclGwWvOK9lW3JemBkaDB2OfyvoRzBoulQNX1vKiHNCyBn6hwMwrVYU3qvI9b1rx2vfC6dJJ8PE254_Pyn-8A-5B6R24U9LUzttWrj3Eau1xo_zCFL0s_4l296RZtbYL7tYf2QfBjuaVU4dfcz-4P5_M88vw-vbiKj-7DmWcUB-mKCEiowRhpQkvEKRJQTUnAmbjGGcioYILnmqeFEhoKeJCdUPKRIuMQInJfnA8-DbWvLTKebY0ra27SIYpTSmEOMs6VjKwpDXOWaVZY8tnblcMQdZXwvpvs_7zrKuEITZU0gnxICxN8-38r-jkD9FkMvtFY02hyScuQJ9q</recordid><startdate>20190101</startdate><enddate>20190101</enddate><creator>Bulygin, Y I</creator><creator>Azimova, N N</creator><creator>Kuptsova, I S</creator><creator>Popov, D S</creator><creator>Maslensky, V V</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>ABUWG</scope><scope>AEUYN</scope><scope>AFKRA</scope><scope>ATCPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>PATMY</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PYCSY</scope></search><sort><creationdate>20190101</creationdate><title>Calculation of Working Spaces Irradiation in the Steel-Melting Plant of Pjsc «Tagmet» at its Reconstruction by the Method of Construction of Epyures of Irradiation</title><author>Bulygin, Y I ; Azimova, N N ; Kuptsova, I S ; Popov, D S ; Maslensky, V V</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c465t-7163b95312ef3ad1056d5fa3b098429b65baba7fa6d1bfcb4debfccc6fb930c23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Control boards</topic><topic>Furnaces</topic><topic>Hygiene</topic><topic>Irradiation</topic><topic>Mathematical analysis</topic><topic>Modernization</topic><topic>Radiation</topic><topic>Radiation effects</topic><topic>Radiation sources</topic><topic>Temperature requirements</topic><topic>Thermal capacity</topic><topic>Working conditions</topic><topic>Workplaces</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bulygin, Y I</creatorcontrib><creatorcontrib>Azimova, N N</creatorcontrib><creatorcontrib>Kuptsova, I S</creatorcontrib><creatorcontrib>Popov, D S</creatorcontrib><creatorcontrib>Maslensky, V V</creatorcontrib><collection>IOP Publishing Free Content</collection><collection>IOPscience (Open Access)</collection><collection>CrossRef</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest One Sustainability</collection><collection>ProQuest Central UK/Ireland</collection><collection>Agricultural &amp; Environmental Science Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>Environmental Science Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Environmental Science Collection</collection><jtitle>IOP conference series. Earth and environmental science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bulygin, Y I</au><au>Azimova, N N</au><au>Kuptsova, I S</au><au>Popov, D S</au><au>Maslensky, V V</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calculation of Working Spaces Irradiation in the Steel-Melting Plant of Pjsc «Tagmet» at its Reconstruction by the Method of Construction of Epyures of Irradiation</atitle><jtitle>IOP conference series. Earth and environmental science</jtitle><addtitle>IOP Conf. Ser.: Earth Environ. Sci</addtitle><date>2019-01-01</date><risdate>2019</risdate><volume>224</volume><issue>1</issue><spage>12052</spage><pages>12052-</pages><issn>1755-1307</issn><issn>1755-1315</issn><eissn>1755-1315</eissn><abstract>With the growth of thermal capacity of the equipment, the tasks of designing new and modernizing existing thermal workshops, taking into account the safe working conditions of staff, are of great importance. However, there are often no experimental data for measuring irradiation and temperature of equipment and workplaces, and the results of a special assessment of working conditions are available only for existing industries and then the method of constructing radiation exposure diagrams comes to the rescue. The article presents the results of calculations of the exposure levels of open and closed workplaces, which showed that the sanitary and hygienic standard on the working area of the EAF-150 was significantly exceeded. Experimental studies of the temperature of the surfaces of the equipment placed on the working platform of DSP-150 showed that the requirements of sanitary and hygienic standards for temperature are met only on the outer wall of the furnace control panel, which is not acceptable. Thus, at the design stage of the steel-smelting shop, when modernizing the furnaces (switching to super-power furnaces DSP-150), the possible negative effects of radiation sources were not taken into account and the distance protection in the shop was practically not effective.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1755-1315/224/1/012052</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1755-1307
ispartof IOP conference series. Earth and environmental science, 2019-01, Vol.224 (1), p.12052
issn 1755-1307
1755-1315
1755-1315
language eng
recordid cdi_proquest_journals_2557500299
source IOP Publishing Free Content; EZB-FREE-00999 freely available EZB journals; IOPscience extra
subjects Control boards
Furnaces
Hygiene
Irradiation
Mathematical analysis
Modernization
Radiation
Radiation effects
Radiation sources
Temperature requirements
Thermal capacity
Working conditions
Workplaces
title Calculation of Working Spaces Irradiation in the Steel-Melting Plant of Pjsc «Tagmet» at its Reconstruction by the Method of Construction of Epyures of Irradiation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T19%3A00%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calculation%20of%20Working%20Spaces%20Irradiation%20in%20the%20Steel-Melting%20Plant%20of%20Pjsc%20%C2%ABTagmet%C2%BB%20at%20its%20Reconstruction%20by%20the%20Method%20of%20Construction%20of%20Epyures%20of%20Irradiation&rft.jtitle=IOP%20conference%20series.%20Earth%20and%20environmental%20science&rft.au=Bulygin,%20Y%20I&rft.date=2019-01-01&rft.volume=224&rft.issue=1&rft.spage=12052&rft.pages=12052-&rft.issn=1755-1307&rft.eissn=1755-1315&rft_id=info:doi/10.1088/1755-1315/224/1/012052&rft_dat=%3Cproquest_cross%3E2557500299%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2557500299&rft_id=info:pmid/&rfr_iscdi=true