The aim of this study is to determine the difference in the quality of groundwater at an industrial location in MM2100 and a residential location, both in Cibuntu, West Java, Indonesia. The parameters used to establish whether or not the water is safe are: standard acidity of the water (pH), total d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IOP conference series. Materials Science and Engineering 2018-11, Vol.453 (1), p.12041
Hauptverfasser: Triana, Novera Elisa, Izzati, Titia, Hartanto, Aditya
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aim of this study is to determine the difference in the quality of groundwater at an industrial location in MM2100 and a residential location, both in Cibuntu, West Java, Indonesia. The parameters used to establish whether or not the water is safe are: standard acidity of the water (pH), total dissolved solid (TDS), and Electrical Conductivity (EC). The results of water tested in MM2100 revealed an average of pH 7-9.7 for acidity, 127.8ppt for total dissolved solid, and 258.5 μS for EC. The results of water tested from the residential location recorded an average of pH 8.0-10 for acidity, 89.4ppt for total dissolved solid, and 179.9 μS for EC. The quality of groundwater for both the industrial and residential locations have been found to be unsafe based on governmental and international standards.