Replacing light sources and the need to determine the technical luminous coefficients

In this work, the authors present the necessity of photometric measurements in order to determine quality parameters when changing light sources with other types of light sources. To emphasize this we conducted a case study, measuring luminous parameters on two different streets, and we determined t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IOP conference series. Materials Science and Engineering 2018-08, Vol.393 (1), p.12014
Hauptverfasser: Spunei, E, Piroi, I, Chioncel, C P, Piroi, F
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page 12014
container_title IOP conference series. Materials Science and Engineering
container_volume 393
creator Spunei, E
Piroi, I
Chioncel, C P
Piroi, F
description In this work, the authors present the necessity of photometric measurements in order to determine quality parameters when changing light sources with other types of light sources. To emphasize this we conducted a case study, measuring luminous parameters on two different streets, and we determined the technical luminous coefficients that establish the lighting system quality. We made photometric measurements on a street with sodium vapours lamps and on a street with LED lamps, determined the technical light parameters and did a comparison of the results. The outcome of the case study underline the need of conducting photometric measurements and of the lighting system redesign such that, upon changing the light sources and the technical characteristics of the lighting systems, the system still fulfils the technical standards requirements. In conclusion, for each space that is to be illuminated, an optimal solution should be found, which ensures both a reduction of the energy consumptions (reducing the system's costs) and meets the technical lighting requirements.
doi_str_mv 10.1088/1757-899X/393/1/012014
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2557056705</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2557056705</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2694-3c29921a4c3f75fc0a930fa07d8c6552a0e2f24fe678a313584240710431e1223</originalsourceid><addsrcrecordid>eNqFkF1LwzAUhoMoOKd_QQLeeFObz6a9lDGnMBHUgXchpCdbRtfWpr3w35tZmQiCFyGHk-e8JzwIXVJyQ0mep1RJleRF8Zbygqc0JZQRKo7Q5PBwfKhzeorOQtgSkikhyAStnqGtjPX1Gld-velxaIbOQsCmLnG_AVwDxKLBJfTQ7XwNX90e7Kb21lS4GmKzGQK2DTjnrYe6D-foxJkqwMX3PUWru_nr7D5ZPi0eZrfLxLKsEAm3rCgYNcJyp6SzxBScOENUmdtMSmYIMMeEg0zlhlMuc8EEUZQIToEyxqfoasxtu-Z9gNDrbfx-HVdqJqUiMosnUtlI2a4JoQOn287vTPehKdF7hXpvR-9N6ahQUz0qjIPX46Bv2p_kx5f5L0y3pYso-wP9J_8TcW1_gA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2557056705</pqid></control><display><type>article</type><title>Replacing light sources and the need to determine the technical luminous coefficients</title><source>Institute of Physics IOPscience extra</source><source>IOP Publishing Free Content</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Free Full-Text Journals in Chemistry</source><creator>Spunei, E ; Piroi, I ; Chioncel, C P ; Piroi, F</creator><creatorcontrib>Spunei, E ; Piroi, I ; Chioncel, C P ; Piroi, F</creatorcontrib><description>In this work, the authors present the necessity of photometric measurements in order to determine quality parameters when changing light sources with other types of light sources. To emphasize this we conducted a case study, measuring luminous parameters on two different streets, and we determined the technical luminous coefficients that establish the lighting system quality. We made photometric measurements on a street with sodium vapours lamps and on a street with LED lamps, determined the technical light parameters and did a comparison of the results. The outcome of the case study underline the need of conducting photometric measurements and of the lighting system redesign such that, upon changing the light sources and the technical characteristics of the lighting systems, the system still fulfils the technical standards requirements. In conclusion, for each space that is to be illuminated, an optimal solution should be found, which ensures both a reduction of the energy consumptions (reducing the system's costs) and meets the technical lighting requirements.</description><identifier>ISSN: 1757-8981</identifier><identifier>ISSN: 1757-899X</identifier><identifier>EISSN: 1757-899X</identifier><identifier>DOI: 10.1088/1757-899X/393/1/012014</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Case studies ; Lamps ; Light emitting diodes ; Light sources ; Lighting ; Lighting systems ; Parameters ; Photometry ; Redesign</subject><ispartof>IOP conference series. Materials Science and Engineering, 2018-08, Vol.393 (1), p.12014</ispartof><rights>Published under licence by IOP Publishing Ltd</rights><rights>2018. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2694-3c29921a4c3f75fc0a930fa07d8c6552a0e2f24fe678a313584240710431e1223</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1757-899X/393/1/012014/pdf$$EPDF$$P50$$Giop$$Hfree_for_read</linktopdf><link.rule.ids>314,776,780,27901,27902,38845,38867,53815,53842</link.rule.ids></links><search><creatorcontrib>Spunei, E</creatorcontrib><creatorcontrib>Piroi, I</creatorcontrib><creatorcontrib>Chioncel, C P</creatorcontrib><creatorcontrib>Piroi, F</creatorcontrib><title>Replacing light sources and the need to determine the technical luminous coefficients</title><title>IOP conference series. Materials Science and Engineering</title><addtitle>IOP Conf. Ser.: Mater. Sci. Eng</addtitle><description>In this work, the authors present the necessity of photometric measurements in order to determine quality parameters when changing light sources with other types of light sources. To emphasize this we conducted a case study, measuring luminous parameters on two different streets, and we determined the technical luminous coefficients that establish the lighting system quality. We made photometric measurements on a street with sodium vapours lamps and on a street with LED lamps, determined the technical light parameters and did a comparison of the results. The outcome of the case study underline the need of conducting photometric measurements and of the lighting system redesign such that, upon changing the light sources and the technical characteristics of the lighting systems, the system still fulfils the technical standards requirements. In conclusion, for each space that is to be illuminated, an optimal solution should be found, which ensures both a reduction of the energy consumptions (reducing the system's costs) and meets the technical lighting requirements.</description><subject>Case studies</subject><subject>Lamps</subject><subject>Light emitting diodes</subject><subject>Light sources</subject><subject>Lighting</subject><subject>Lighting systems</subject><subject>Parameters</subject><subject>Photometry</subject><subject>Redesign</subject><issn>1757-8981</issn><issn>1757-899X</issn><issn>1757-899X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>O3W</sourceid><sourceid>BENPR</sourceid><recordid>eNqFkF1LwzAUhoMoOKd_QQLeeFObz6a9lDGnMBHUgXchpCdbRtfWpr3w35tZmQiCFyGHk-e8JzwIXVJyQ0mep1RJleRF8Zbygqc0JZQRKo7Q5PBwfKhzeorOQtgSkikhyAStnqGtjPX1Gld-velxaIbOQsCmLnG_AVwDxKLBJfTQ7XwNX90e7Kb21lS4GmKzGQK2DTjnrYe6D-foxJkqwMX3PUWru_nr7D5ZPi0eZrfLxLKsEAm3rCgYNcJyp6SzxBScOENUmdtMSmYIMMeEg0zlhlMuc8EEUZQIToEyxqfoasxtu-Z9gNDrbfx-HVdqJqUiMosnUtlI2a4JoQOn287vTPehKdF7hXpvR-9N6ahQUz0qjIPX46Bv2p_kx5f5L0y3pYso-wP9J_8TcW1_gA</recordid><startdate>20180810</startdate><enddate>20180810</enddate><creator>Spunei, E</creator><creator>Piroi, I</creator><creator>Chioncel, C P</creator><creator>Piroi, F</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>KB.</scope><scope>L6V</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20180810</creationdate><title>Replacing light sources and the need to determine the technical luminous coefficients</title><author>Spunei, E ; Piroi, I ; Chioncel, C P ; Piroi, F</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2694-3c29921a4c3f75fc0a930fa07d8c6552a0e2f24fe678a313584240710431e1223</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Case studies</topic><topic>Lamps</topic><topic>Light emitting diodes</topic><topic>Light sources</topic><topic>Lighting</topic><topic>Lighting systems</topic><topic>Parameters</topic><topic>Photometry</topic><topic>Redesign</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Spunei, E</creatorcontrib><creatorcontrib>Piroi, I</creatorcontrib><creatorcontrib>Chioncel, C P</creatorcontrib><creatorcontrib>Piroi, F</creatorcontrib><collection>IOP Publishing Free Content</collection><collection>IOPscience (Open Access)</collection><collection>CrossRef</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>Materials Science Database</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>IOP conference series. Materials Science and Engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Spunei, E</au><au>Piroi, I</au><au>Chioncel, C P</au><au>Piroi, F</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Replacing light sources and the need to determine the technical luminous coefficients</atitle><jtitle>IOP conference series. Materials Science and Engineering</jtitle><addtitle>IOP Conf. Ser.: Mater. Sci. Eng</addtitle><date>2018-08-10</date><risdate>2018</risdate><volume>393</volume><issue>1</issue><spage>12014</spage><pages>12014-</pages><issn>1757-8981</issn><issn>1757-899X</issn><eissn>1757-899X</eissn><abstract>In this work, the authors present the necessity of photometric measurements in order to determine quality parameters when changing light sources with other types of light sources. To emphasize this we conducted a case study, measuring luminous parameters on two different streets, and we determined the technical luminous coefficients that establish the lighting system quality. We made photometric measurements on a street with sodium vapours lamps and on a street with LED lamps, determined the technical light parameters and did a comparison of the results. The outcome of the case study underline the need of conducting photometric measurements and of the lighting system redesign such that, upon changing the light sources and the technical characteristics of the lighting systems, the system still fulfils the technical standards requirements. In conclusion, for each space that is to be illuminated, an optimal solution should be found, which ensures both a reduction of the energy consumptions (reducing the system's costs) and meets the technical lighting requirements.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1757-899X/393/1/012014</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1757-8981
ispartof IOP conference series. Materials Science and Engineering, 2018-08, Vol.393 (1), p.12014
issn 1757-8981
1757-899X
1757-899X
language eng
recordid cdi_proquest_journals_2557056705
source Institute of Physics IOPscience extra; IOP Publishing Free Content; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Free Full-Text Journals in Chemistry
subjects Case studies
Lamps
Light emitting diodes
Light sources
Lighting
Lighting systems
Parameters
Photometry
Redesign
title Replacing light sources and the need to determine the technical luminous coefficients
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T02%3A45%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Replacing%20light%20sources%20and%20the%20need%20to%20determine%20the%20technical%20luminous%20coefficients&rft.jtitle=IOP%20conference%20series.%20Materials%20Science%20and%20Engineering&rft.au=Spunei,%20E&rft.date=2018-08-10&rft.volume=393&rft.issue=1&rft.spage=12014&rft.pages=12014-&rft.issn=1757-8981&rft.eissn=1757-899X&rft_id=info:doi/10.1088/1757-899X/393/1/012014&rft_dat=%3Cproquest_cross%3E2557056705%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2557056705&rft_id=info:pmid/&rfr_iscdi=true