A Novel Calibration Method for Signal Leakage between Multiple Channels in Array Imaging

In this paper, the array imaging process with the presence of signal leakage between channels is derived and analyzed in short-range imaging applications. The echo wave of the system can be divided into two parts: the echo signals we expected, and the echo signal that resulted from the leaked signal...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electronics (Basel) 2020-10, Vol.9 (10), p.1628
Hauptverfasser: Cui, Zhenmao, Cheng, Binbin, Deng, Xianjin, Wu, Qiang, An, Jianfei, Yu, Yang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 10
container_start_page 1628
container_title Electronics (Basel)
container_volume 9
creator Cui, Zhenmao
Cheng, Binbin
Deng, Xianjin
Wu, Qiang
An, Jianfei
Yu, Yang
description In this paper, the array imaging process with the presence of signal leakage between channels is derived and analyzed in short-range imaging applications. The echo wave of the system can be divided into two parts: the echo signals we expected, and the echo signal that resulted from the leaked signals. Signals leaked to the adjacent channels can lead to ghosts which can deeply deteriorate the system cross resolution. To solve this problem, a concise calibration method is proposed to remove the impacts of the signal leakages on the imaging quality. Furthermore, the results based on the simulation and the real-world data validate the effectiveness of the proposed method, which indicates that this calibration method can mostly cancel the influence of the signal leakages.
doi_str_mv 10.3390/electronics9101628
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2548436582</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2548436582</sourcerecordid><originalsourceid>FETCH-LOGICAL-c319t-b3b94a631c8f1f23e61dc13d1443504c80f6c69b05eb066d8440056e539b71163</originalsourceid><addsrcrecordid>eNplkE1LAzEYhIMoWLR_wFPA82q-Nt0cy-JHoepBBW9Lkn13m5omNdkq_feu1IPgXGYOD8MwCF1QcsW5ItfgwQ4pBmezooRKVh2hCSMzVSim2PGffIqmOa_JKEV5xckEvc3xY_wEj2vtnUl6cDHgBxhWscVdTPjZ9UF7vAT9rnvABoYvgJHY-cFtPeB6pUMAn7ELeJ6S3uPFRvcu9OfopNM-w_TXz9Dr7c1LfV8sn-4W9XxZWE7VUBhulNCSU1t1tGMcJG0t5S0VgpdE2Ip00kplSAmGSNlWQhBSSii5MjNKJT9Dl4febYofO8hDs467NG7ODStFJbgsKzZS7EDZFHNO0DXb5DY67RtKmp8Tm_8n8m_r9WaK</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2548436582</pqid></control><display><type>article</type><title>A Novel Calibration Method for Signal Leakage between Multiple Channels in Array Imaging</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>MDPI - Multidisciplinary Digital Publishing Institute</source><creator>Cui, Zhenmao ; Cheng, Binbin ; Deng, Xianjin ; Wu, Qiang ; An, Jianfei ; Yu, Yang</creator><creatorcontrib>Cui, Zhenmao ; Cheng, Binbin ; Deng, Xianjin ; Wu, Qiang ; An, Jianfei ; Yu, Yang</creatorcontrib><description>In this paper, the array imaging process with the presence of signal leakage between channels is derived and analyzed in short-range imaging applications. The echo wave of the system can be divided into two parts: the echo signals we expected, and the echo signal that resulted from the leaked signals. Signals leaked to the adjacent channels can lead to ghosts which can deeply deteriorate the system cross resolution. To solve this problem, a concise calibration method is proposed to remove the impacts of the signal leakages on the imaging quality. Furthermore, the results based on the simulation and the real-world data validate the effectiveness of the proposed method, which indicates that this calibration method can mostly cancel the influence of the signal leakages.</description><identifier>ISSN: 2079-9292</identifier><identifier>EISSN: 2079-9292</identifier><identifier>DOI: 10.3390/electronics9101628</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Antennas ; Arrays ; Calibration ; Channels ; Ghosts ; Imaging ; Leakage ; Noise ; Receivers &amp; amplifiers ; Signal processing</subject><ispartof>Electronics (Basel), 2020-10, Vol.9 (10), p.1628</ispartof><rights>2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c319t-b3b94a631c8f1f23e61dc13d1443504c80f6c69b05eb066d8440056e539b71163</citedby><cites>FETCH-LOGICAL-c319t-b3b94a631c8f1f23e61dc13d1443504c80f6c69b05eb066d8440056e539b71163</cites><orcidid>0000-0002-1804-2095</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,27911,27912</link.rule.ids></links><search><creatorcontrib>Cui, Zhenmao</creatorcontrib><creatorcontrib>Cheng, Binbin</creatorcontrib><creatorcontrib>Deng, Xianjin</creatorcontrib><creatorcontrib>Wu, Qiang</creatorcontrib><creatorcontrib>An, Jianfei</creatorcontrib><creatorcontrib>Yu, Yang</creatorcontrib><title>A Novel Calibration Method for Signal Leakage between Multiple Channels in Array Imaging</title><title>Electronics (Basel)</title><description>In this paper, the array imaging process with the presence of signal leakage between channels is derived and analyzed in short-range imaging applications. The echo wave of the system can be divided into two parts: the echo signals we expected, and the echo signal that resulted from the leaked signals. Signals leaked to the adjacent channels can lead to ghosts which can deeply deteriorate the system cross resolution. To solve this problem, a concise calibration method is proposed to remove the impacts of the signal leakages on the imaging quality. Furthermore, the results based on the simulation and the real-world data validate the effectiveness of the proposed method, which indicates that this calibration method can mostly cancel the influence of the signal leakages.</description><subject>Antennas</subject><subject>Arrays</subject><subject>Calibration</subject><subject>Channels</subject><subject>Ghosts</subject><subject>Imaging</subject><subject>Leakage</subject><subject>Noise</subject><subject>Receivers &amp; amplifiers</subject><subject>Signal processing</subject><issn>2079-9292</issn><issn>2079-9292</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNplkE1LAzEYhIMoWLR_wFPA82q-Nt0cy-JHoepBBW9Lkn13m5omNdkq_feu1IPgXGYOD8MwCF1QcsW5ItfgwQ4pBmezooRKVh2hCSMzVSim2PGffIqmOa_JKEV5xckEvc3xY_wEj2vtnUl6cDHgBxhWscVdTPjZ9UF7vAT9rnvABoYvgJHY-cFtPeB6pUMAn7ELeJ6S3uPFRvcu9OfopNM-w_TXz9Dr7c1LfV8sn-4W9XxZWE7VUBhulNCSU1t1tGMcJG0t5S0VgpdE2Ip00kplSAmGSNlWQhBSSii5MjNKJT9Dl4febYofO8hDs467NG7ODStFJbgsKzZS7EDZFHNO0DXb5DY67RtKmp8Tm_8n8m_r9WaK</recordid><startdate>20201001</startdate><enddate>20201001</enddate><creator>Cui, Zhenmao</creator><creator>Cheng, Binbin</creator><creator>Deng, Xianjin</creator><creator>Wu, Qiang</creator><creator>An, Jianfei</creator><creator>Yu, Yang</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L7M</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><orcidid>https://orcid.org/0000-0002-1804-2095</orcidid></search><sort><creationdate>20201001</creationdate><title>A Novel Calibration Method for Signal Leakage between Multiple Channels in Array Imaging</title><author>Cui, Zhenmao ; Cheng, Binbin ; Deng, Xianjin ; Wu, Qiang ; An, Jianfei ; Yu, Yang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c319t-b3b94a631c8f1f23e61dc13d1443504c80f6c69b05eb066d8440056e539b71163</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Antennas</topic><topic>Arrays</topic><topic>Calibration</topic><topic>Channels</topic><topic>Ghosts</topic><topic>Imaging</topic><topic>Leakage</topic><topic>Noise</topic><topic>Receivers &amp; amplifiers</topic><topic>Signal processing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cui, Zhenmao</creatorcontrib><creatorcontrib>Cheng, Binbin</creatorcontrib><creatorcontrib>Deng, Xianjin</creatorcontrib><creatorcontrib>Wu, Qiang</creatorcontrib><creatorcontrib>An, Jianfei</creatorcontrib><creatorcontrib>Yu, Yang</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection (ProQuest)</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Advanced Technologies &amp; Aerospace Database</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Electronics (Basel)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cui, Zhenmao</au><au>Cheng, Binbin</au><au>Deng, Xianjin</au><au>Wu, Qiang</au><au>An, Jianfei</au><au>Yu, Yang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Novel Calibration Method for Signal Leakage between Multiple Channels in Array Imaging</atitle><jtitle>Electronics (Basel)</jtitle><date>2020-10-01</date><risdate>2020</risdate><volume>9</volume><issue>10</issue><spage>1628</spage><pages>1628-</pages><issn>2079-9292</issn><eissn>2079-9292</eissn><abstract>In this paper, the array imaging process with the presence of signal leakage between channels is derived and analyzed in short-range imaging applications. The echo wave of the system can be divided into two parts: the echo signals we expected, and the echo signal that resulted from the leaked signals. Signals leaked to the adjacent channels can lead to ghosts which can deeply deteriorate the system cross resolution. To solve this problem, a concise calibration method is proposed to remove the impacts of the signal leakages on the imaging quality. Furthermore, the results based on the simulation and the real-world data validate the effectiveness of the proposed method, which indicates that this calibration method can mostly cancel the influence of the signal leakages.</abstract><cop>Basel</cop><pub>MDPI AG</pub><doi>10.3390/electronics9101628</doi><orcidid>https://orcid.org/0000-0002-1804-2095</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2079-9292
ispartof Electronics (Basel), 2020-10, Vol.9 (10), p.1628
issn 2079-9292
2079-9292
language eng
recordid cdi_proquest_journals_2548436582
source Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; MDPI - Multidisciplinary Digital Publishing Institute
subjects Antennas
Arrays
Calibration
Channels
Ghosts
Imaging
Leakage
Noise
Receivers & amplifiers
Signal processing
title A Novel Calibration Method for Signal Leakage between Multiple Channels in Array Imaging
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T16%3A21%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Novel%20Calibration%20Method%20for%20Signal%20Leakage%20between%20Multiple%20Channels%20in%20Array%20Imaging&rft.jtitle=Electronics%20(Basel)&rft.au=Cui,%20Zhenmao&rft.date=2020-10-01&rft.volume=9&rft.issue=10&rft.spage=1628&rft.pages=1628-&rft.issn=2079-9292&rft.eissn=2079-9292&rft_id=info:doi/10.3390/electronics9101628&rft_dat=%3Cproquest_cross%3E2548436582%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2548436582&rft_id=info:pmid/&rfr_iscdi=true