Comparison of ECG Baseline Wander Removal Techniques and Improvement Based on Moving Average of Wavelet Approximation Coefficients

The baseline wander is among the artifacts that corrupt the ECG signal. This noise can affect some signal features, in particular the ST segment, which is an important marker for the diagnosis of ischemia. This paper presents a study on the effectiveness of several methods and techniques for suppres...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Bioautomation 2021, Vol.25 (2), p.183-204
Hauptverfasser: Aqil, Mounaim, Jbari, Atman, Bourouhou, Abdennasser
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 204
container_issue 2
container_start_page 183
container_title Bioautomation
container_volume 25
creator Aqil, Mounaim
Jbari, Atman
Bourouhou, Abdennasser
description The baseline wander is among the artifacts that corrupt the ECG signal. This noise can affect some signal features, in particular the ST segment, which is an important marker for the diagnosis of ischemia. This paper presents a study on the effectiveness of several methods and techniques for suppressing the baseline wonder (BW) from the ECG signals. As a result, a new technique called moving average of wavelet approximation coefficients (DWT-MAV) is proposed. The techniques concerned are the moving average, the approximation of the baseline by polynomial fitting, the Savitzky-Golay filtering, and the discrete wavelet transform (DWT). The comparison of this techniques is performed using the main criteria for assessing the BW denoising quality criteria such mean square error (MSE), percent root mean square difference (PRD) and correlation coefficient (COR). In this paper, three other criteria of comparison are proposed namely the number of samples of the ECG signal, the baseline frequency variation and the time processing. Two of these new indices are related to possible real time ECG denoising. To improve the quality of BW suppression including the new indices, a new method is proposed. This technique is a combination of the DWT and the moving average methods. This new technique performs the best compromise in terms of MSE, PRD, coefficient correlation and the time processing. The simulations were performed on ECG recording from MIT-BIH database with synthetic and real baselines.
doi_str_mv 10.7546/ijba.2021.25.2.000770
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2548295757</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2548295757</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1910-11b9f2e594a13ab2318c176b37734402217ad34a1ebb6fa4fe61b1ba9f43f2933</originalsourceid><addsrcrecordid>eNotUN9LwzAQLqLgmPsThIDPrbmkbdbHWeYcTASZ7DGk3WVmtM1MtqKv_uWmbvdyB9-Pu_ui6B5oIrI0fzT7SiWMMkhYlrCEUioEvYpGwCGNGWdwfZmhoOw2mni_p0MJmhX5KPotbXtQznjbEavJvFyQJ-WxMR2Sjeq26Mg7trZXDVlj_dmZrxN6EgCybA_O9thid_yXbEmweLW96XZk1qNTOxwcN6rHBo9kdgj0b9Oqowm80qLWpjZB7O-iG60aj5NLH0cfz_N1-RKv3hbLcraKayiAxgBVoRlmRaqAq4pxmNYg8ooLwdOUMgZCbXkAsapyrVKNOVRQqUKnXLOC83H0cPYNhwxfHOXenlwXVkqWpVNWZCITgZWdWbWz3jvU8uDC1e5HApVD4nJIXA6JB5lk8pw4_wPlZXV7</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2548295757</pqid></control><display><type>article</type><title>Comparison of ECG Baseline Wander Removal Techniques and Improvement Based on Moving Average of Wavelet Approximation Coefficients</title><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Aqil, Mounaim ; Jbari, Atman ; Bourouhou, Abdennasser</creator><creatorcontrib>Aqil, Mounaim ; Jbari, Atman ; Bourouhou, Abdennasser ; Engineering and Applied Technologies Laboratory, Superior School of Technology, Sultan Moulay Slimane University in Beni Mellal, Morocco ; Electronic Systems Sensors and Nanobiotechnologies Research Team, High School of Technical Education, Mohammed V University in Rabat, Morocco</creatorcontrib><description>The baseline wander is among the artifacts that corrupt the ECG signal. This noise can affect some signal features, in particular the ST segment, which is an important marker for the diagnosis of ischemia. This paper presents a study on the effectiveness of several methods and techniques for suppressing the baseline wonder (BW) from the ECG signals. As a result, a new technique called moving average of wavelet approximation coefficients (DWT-MAV) is proposed. The techniques concerned are the moving average, the approximation of the baseline by polynomial fitting, the Savitzky-Golay filtering, and the discrete wavelet transform (DWT). The comparison of this techniques is performed using the main criteria for assessing the BW denoising quality criteria such mean square error (MSE), percent root mean square difference (PRD) and correlation coefficient (COR). In this paper, three other criteria of comparison are proposed namely the number of samples of the ECG signal, the baseline frequency variation and the time processing. Two of these new indices are related to possible real time ECG denoising. To improve the quality of BW suppression including the new indices, a new method is proposed. This technique is a combination of the DWT and the moving average methods. This new technique performs the best compromise in terms of MSE, PRD, coefficient correlation and the time processing. The simulations were performed on ECG recording from MIT-BIH database with synthetic and real baselines.</description><identifier>ISSN: 1314-1902</identifier><identifier>EISSN: 1314-2321</identifier><identifier>DOI: 10.7546/ijba.2021.25.2.000770</identifier><language>eng</language><publisher>Sophia: Bulgarska Akademiya na Naukite / Bulgarian Academy of Sciences</publisher><subject>Approximation ; Wavelet transforms</subject><ispartof>Bioautomation, 2021, Vol.25 (2), p.183-204</ispartof><rights>2021. This work is published under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,865,4025,27928,27929,27930</link.rule.ids></links><search><creatorcontrib>Aqil, Mounaim</creatorcontrib><creatorcontrib>Jbari, Atman</creatorcontrib><creatorcontrib>Bourouhou, Abdennasser</creatorcontrib><creatorcontrib>Engineering and Applied Technologies Laboratory, Superior School of Technology, Sultan Moulay Slimane University in Beni Mellal, Morocco</creatorcontrib><creatorcontrib>Electronic Systems Sensors and Nanobiotechnologies Research Team, High School of Technical Education, Mohammed V University in Rabat, Morocco</creatorcontrib><title>Comparison of ECG Baseline Wander Removal Techniques and Improvement Based on Moving Average of Wavelet Approximation Coefficients</title><title>Bioautomation</title><description>The baseline wander is among the artifacts that corrupt the ECG signal. This noise can affect some signal features, in particular the ST segment, which is an important marker for the diagnosis of ischemia. This paper presents a study on the effectiveness of several methods and techniques for suppressing the baseline wonder (BW) from the ECG signals. As a result, a new technique called moving average of wavelet approximation coefficients (DWT-MAV) is proposed. The techniques concerned are the moving average, the approximation of the baseline by polynomial fitting, the Savitzky-Golay filtering, and the discrete wavelet transform (DWT). The comparison of this techniques is performed using the main criteria for assessing the BW denoising quality criteria such mean square error (MSE), percent root mean square difference (PRD) and correlation coefficient (COR). In this paper, three other criteria of comparison are proposed namely the number of samples of the ECG signal, the baseline frequency variation and the time processing. Two of these new indices are related to possible real time ECG denoising. To improve the quality of BW suppression including the new indices, a new method is proposed. This technique is a combination of the DWT and the moving average methods. This new technique performs the best compromise in terms of MSE, PRD, coefficient correlation and the time processing. The simulations were performed on ECG recording from MIT-BIH database with synthetic and real baselines.</description><subject>Approximation</subject><subject>Wavelet transforms</subject><issn>1314-1902</issn><issn>1314-2321</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNotUN9LwzAQLqLgmPsThIDPrbmkbdbHWeYcTASZ7DGk3WVmtM1MtqKv_uWmbvdyB9-Pu_ui6B5oIrI0fzT7SiWMMkhYlrCEUioEvYpGwCGNGWdwfZmhoOw2mni_p0MJmhX5KPotbXtQznjbEavJvFyQJ-WxMR2Sjeq26Mg7trZXDVlj_dmZrxN6EgCybA_O9thid_yXbEmweLW96XZk1qNTOxwcN6rHBo9kdgj0b9Oqowm80qLWpjZB7O-iG60aj5NLH0cfz_N1-RKv3hbLcraKayiAxgBVoRlmRaqAq4pxmNYg8ooLwdOUMgZCbXkAsapyrVKNOVRQqUKnXLOC83H0cPYNhwxfHOXenlwXVkqWpVNWZCITgZWdWbWz3jvU8uDC1e5HApVD4nJIXA6JB5lk8pw4_wPlZXV7</recordid><startdate>2021</startdate><enddate>2021</enddate><creator>Aqil, Mounaim</creator><creator>Jbari, Atman</creator><creator>Bourouhou, Abdennasser</creator><general>Bulgarska Akademiya na Naukite / Bulgarian Academy of Sciences</general><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>2021</creationdate><title>Comparison of ECG Baseline Wander Removal Techniques and Improvement Based on Moving Average of Wavelet Approximation Coefficients</title><author>Aqil, Mounaim ; Jbari, Atman ; Bourouhou, Abdennasser</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1910-11b9f2e594a13ab2318c176b37734402217ad34a1ebb6fa4fe61b1ba9f43f2933</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Approximation</topic><topic>Wavelet transforms</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Aqil, Mounaim</creatorcontrib><creatorcontrib>Jbari, Atman</creatorcontrib><creatorcontrib>Bourouhou, Abdennasser</creatorcontrib><creatorcontrib>Engineering and Applied Technologies Laboratory, Superior School of Technology, Sultan Moulay Slimane University in Beni Mellal, Morocco</creatorcontrib><creatorcontrib>Electronic Systems Sensors and Nanobiotechnologies Research Team, High School of Technical Education, Mohammed V University in Rabat, Morocco</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Access via ProQuest (Open Access)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Bioautomation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Aqil, Mounaim</au><au>Jbari, Atman</au><au>Bourouhou, Abdennasser</au><aucorp>Engineering and Applied Technologies Laboratory, Superior School of Technology, Sultan Moulay Slimane University in Beni Mellal, Morocco</aucorp><aucorp>Electronic Systems Sensors and Nanobiotechnologies Research Team, High School of Technical Education, Mohammed V University in Rabat, Morocco</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of ECG Baseline Wander Removal Techniques and Improvement Based on Moving Average of Wavelet Approximation Coefficients</atitle><jtitle>Bioautomation</jtitle><date>2021</date><risdate>2021</risdate><volume>25</volume><issue>2</issue><spage>183</spage><epage>204</epage><pages>183-204</pages><issn>1314-1902</issn><eissn>1314-2321</eissn><abstract>The baseline wander is among the artifacts that corrupt the ECG signal. This noise can affect some signal features, in particular the ST segment, which is an important marker for the diagnosis of ischemia. This paper presents a study on the effectiveness of several methods and techniques for suppressing the baseline wonder (BW) from the ECG signals. As a result, a new technique called moving average of wavelet approximation coefficients (DWT-MAV) is proposed. The techniques concerned are the moving average, the approximation of the baseline by polynomial fitting, the Savitzky-Golay filtering, and the discrete wavelet transform (DWT). The comparison of this techniques is performed using the main criteria for assessing the BW denoising quality criteria such mean square error (MSE), percent root mean square difference (PRD) and correlation coefficient (COR). In this paper, three other criteria of comparison are proposed namely the number of samples of the ECG signal, the baseline frequency variation and the time processing. Two of these new indices are related to possible real time ECG denoising. To improve the quality of BW suppression including the new indices, a new method is proposed. This technique is a combination of the DWT and the moving average methods. This new technique performs the best compromise in terms of MSE, PRD, coefficient correlation and the time processing. The simulations were performed on ECG recording from MIT-BIH database with synthetic and real baselines.</abstract><cop>Sophia</cop><pub>Bulgarska Akademiya na Naukite / Bulgarian Academy of Sciences</pub><doi>10.7546/ijba.2021.25.2.000770</doi><tpages>22</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1314-1902
ispartof Bioautomation, 2021, Vol.25 (2), p.183-204
issn 1314-1902
1314-2321
language eng
recordid cdi_proquest_journals_2548295757
source DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals
subjects Approximation
Wavelet transforms
title Comparison of ECG Baseline Wander Removal Techniques and Improvement Based on Moving Average of Wavelet Approximation Coefficients
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-12T15%3A46%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20ECG%20Baseline%20Wander%20Removal%20Techniques%20and%20Improvement%20Based%20on%20Moving%20Average%20of%20Wavelet%20Approximation%20Coefficients&rft.jtitle=Bioautomation&rft.au=Aqil,%20Mounaim&rft.aucorp=Engineering%20and%20Applied%20Technologies%20Laboratory,%20Superior%20School%20of%20Technology,%20Sultan%20Moulay%20Slimane%20University%20in%20Beni%20Mellal,%20Morocco&rft.date=2021&rft.volume=25&rft.issue=2&rft.spage=183&rft.epage=204&rft.pages=183-204&rft.issn=1314-1902&rft.eissn=1314-2321&rft_id=info:doi/10.7546/ijba.2021.25.2.000770&rft_dat=%3Cproquest_cross%3E2548295757%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2548295757&rft_id=info:pmid/&rfr_iscdi=true