Toward a High Performance IPMC Soft Actuator using A disturbance-aided method
Besides the advantages of Ionic polymer-metal composites (IPMCs) for biomedical applications, there are some drawbacks in their performance, which can be enhanced. One of those critical drawbacks is "back relaxation" (BR). If we apply a step voltage to IPMC, it will bend in the anode direc...
Gespeichert in:
Veröffentlicht in: | arXiv.org 2021-06 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | |
container_title | arXiv.org |
container_volume | |
creator | Annabestani, Mohsen Mohammad Hossein Sayad Esmaeili-Dokht, Pouria Fardmanesh, Mehdi |
description | Besides the advantages of Ionic polymer-metal composites (IPMCs) for biomedical applications, there are some drawbacks in their performance, which can be enhanced. One of those critical drawbacks is "back relaxation" (BR). If we apply a step voltage to IPMC, it will bend in the anode direction. Afterward, there is an unwanted and relatively slow counter-bending toward the cathode side. There are some disadvantages in the current BR control methods of IPMC actuators that prevent them from being used in real applications. This paper presents a new non-feedback method for eliminating the BR effect of non-patterned IPMCs by using a relatively high-frequency disturbance and proving it by theoretical and experimental explanations. The results show that the proposed method, needless to have any pattern on the electrodes of the IPMCs, can significantly eliminate the BR effect. Unlike the patterned IPMCs, no reduction will occur in the bending amplitude of IPMC, and even we can see the increased bending amplitude. |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2544999306</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2544999306</sourcerecordid><originalsourceid>FETCH-proquest_journals_25449993063</originalsourceid><addsrcrecordid>eNqNykELgjAYgOERBEn5Hz7oLKxNLY8ihR0Eoe6y3NRJuvq20d-voB_Q6T28z4IEjPNddIgZW5HQ2pFSytI9SxIekOpqXgIlCCh1P0CtsDM4iblVcK6rAi6mc5C3zgtnELzVcw85SG2dx9uXRUJLJWFSbjByQ5aduFsV_rom29PxWpTRA83TK-ua0XicP6thSRxnWcZpyv9Tb_uJPOQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2544999306</pqid></control><display><type>article</type><title>Toward a High Performance IPMC Soft Actuator using A disturbance-aided method</title><source>Free E- Journals</source><creator>Annabestani, Mohsen ; Mohammad Hossein Sayad ; Esmaeili-Dokht, Pouria ; Fardmanesh, Mehdi</creator><creatorcontrib>Annabestani, Mohsen ; Mohammad Hossein Sayad ; Esmaeili-Dokht, Pouria ; Fardmanesh, Mehdi</creatorcontrib><description>Besides the advantages of Ionic polymer-metal composites (IPMCs) for biomedical applications, there are some drawbacks in their performance, which can be enhanced. One of those critical drawbacks is "back relaxation" (BR). If we apply a step voltage to IPMC, it will bend in the anode direction. Afterward, there is an unwanted and relatively slow counter-bending toward the cathode side. There are some disadvantages in the current BR control methods of IPMC actuators that prevent them from being used in real applications. This paper presents a new non-feedback method for eliminating the BR effect of non-patterned IPMCs by using a relatively high-frequency disturbance and proving it by theoretical and experimental explanations. The results show that the proposed method, needless to have any pattern on the electrodes of the IPMCs, can significantly eliminate the BR effect. Unlike the patterned IPMCs, no reduction will occur in the bending amplitude of IPMC, and even we can see the increased bending amplitude.</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Actuators ; Amplitudes ; Bending ; Biomedical materials ; Control methods ; Polymer matrix composites ; Step voltage</subject><ispartof>arXiv.org, 2021-06</ispartof><rights>2021. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>776,780</link.rule.ids></links><search><creatorcontrib>Annabestani, Mohsen</creatorcontrib><creatorcontrib>Mohammad Hossein Sayad</creatorcontrib><creatorcontrib>Esmaeili-Dokht, Pouria</creatorcontrib><creatorcontrib>Fardmanesh, Mehdi</creatorcontrib><title>Toward a High Performance IPMC Soft Actuator using A disturbance-aided method</title><title>arXiv.org</title><description>Besides the advantages of Ionic polymer-metal composites (IPMCs) for biomedical applications, there are some drawbacks in their performance, which can be enhanced. One of those critical drawbacks is "back relaxation" (BR). If we apply a step voltage to IPMC, it will bend in the anode direction. Afterward, there is an unwanted and relatively slow counter-bending toward the cathode side. There are some disadvantages in the current BR control methods of IPMC actuators that prevent them from being used in real applications. This paper presents a new non-feedback method for eliminating the BR effect of non-patterned IPMCs by using a relatively high-frequency disturbance and proving it by theoretical and experimental explanations. The results show that the proposed method, needless to have any pattern on the electrodes of the IPMCs, can significantly eliminate the BR effect. Unlike the patterned IPMCs, no reduction will occur in the bending amplitude of IPMC, and even we can see the increased bending amplitude.</description><subject>Actuators</subject><subject>Amplitudes</subject><subject>Bending</subject><subject>Biomedical materials</subject><subject>Control methods</subject><subject>Polymer matrix composites</subject><subject>Step voltage</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>BENPR</sourceid><recordid>eNqNykELgjAYgOERBEn5Hz7oLKxNLY8ihR0Eoe6y3NRJuvq20d-voB_Q6T28z4IEjPNddIgZW5HQ2pFSytI9SxIekOpqXgIlCCh1P0CtsDM4iblVcK6rAi6mc5C3zgtnELzVcw85SG2dx9uXRUJLJWFSbjByQ5aduFsV_rom29PxWpTRA83TK-ua0XicP6thSRxnWcZpyv9Tb_uJPOQ</recordid><startdate>20210613</startdate><enddate>20210613</enddate><creator>Annabestani, Mohsen</creator><creator>Mohammad Hossein Sayad</creator><creator>Esmaeili-Dokht, Pouria</creator><creator>Fardmanesh, Mehdi</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20210613</creationdate><title>Toward a High Performance IPMC Soft Actuator using A disturbance-aided method</title><author>Annabestani, Mohsen ; Mohammad Hossein Sayad ; Esmaeili-Dokht, Pouria ; Fardmanesh, Mehdi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_25449993063</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Actuators</topic><topic>Amplitudes</topic><topic>Bending</topic><topic>Biomedical materials</topic><topic>Control methods</topic><topic>Polymer matrix composites</topic><topic>Step voltage</topic><toplevel>online_resources</toplevel><creatorcontrib>Annabestani, Mohsen</creatorcontrib><creatorcontrib>Mohammad Hossein Sayad</creatorcontrib><creatorcontrib>Esmaeili-Dokht, Pouria</creatorcontrib><creatorcontrib>Fardmanesh, Mehdi</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Annabestani, Mohsen</au><au>Mohammad Hossein Sayad</au><au>Esmaeili-Dokht, Pouria</au><au>Fardmanesh, Mehdi</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>Toward a High Performance IPMC Soft Actuator using A disturbance-aided method</atitle><jtitle>arXiv.org</jtitle><date>2021-06-13</date><risdate>2021</risdate><eissn>2331-8422</eissn><abstract>Besides the advantages of Ionic polymer-metal composites (IPMCs) for biomedical applications, there are some drawbacks in their performance, which can be enhanced. One of those critical drawbacks is "back relaxation" (BR). If we apply a step voltage to IPMC, it will bend in the anode direction. Afterward, there is an unwanted and relatively slow counter-bending toward the cathode side. There are some disadvantages in the current BR control methods of IPMC actuators that prevent them from being used in real applications. This paper presents a new non-feedback method for eliminating the BR effect of non-patterned IPMCs by using a relatively high-frequency disturbance and proving it by theoretical and experimental explanations. The results show that the proposed method, needless to have any pattern on the electrodes of the IPMCs, can significantly eliminate the BR effect. Unlike the patterned IPMCs, no reduction will occur in the bending amplitude of IPMC, and even we can see the increased bending amplitude.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | EISSN: 2331-8422 |
ispartof | arXiv.org, 2021-06 |
issn | 2331-8422 |
language | eng |
recordid | cdi_proquest_journals_2544999306 |
source | Free E- Journals |
subjects | Actuators Amplitudes Bending Biomedical materials Control methods Polymer matrix composites Step voltage |
title | Toward a High Performance IPMC Soft Actuator using A disturbance-aided method |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T19%3A43%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=Toward%20a%20High%20Performance%20IPMC%20Soft%20Actuator%20using%20A%20disturbance-aided%20method&rft.jtitle=arXiv.org&rft.au=Annabestani,%20Mohsen&rft.date=2021-06-13&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E2544999306%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2544999306&rft_id=info:pmid/&rfr_iscdi=true |