Evaluation of the analytical performance of the Beckman Coulter Unicel DXI 800 Access Total 25(OH) Vitamin D immunoassay

As vitamin D has recently been implicated in various diseases, vitamin D testing has gained a lot more significance. Vitamin D deficiency is quite prevalent, and detection of this condition is important. Several manufacturers have developed new automated immunoassays for this purpose. In this study,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Laboratoriumsmedizin 2018-10, Vol.42 (5), p.205-211
Hauptverfasser: Topçuoğlu, Canan, Sezer, Sevilay, Yılmaz, Fatma Meriç, Kösem, Arzu, Ercan, Mujgan, Turhan, Turan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 211
container_issue 5
container_start_page 205
container_title Laboratoriumsmedizin
container_volume 42
creator Topçuoğlu, Canan
Sezer, Sevilay
Yılmaz, Fatma Meriç
Kösem, Arzu
Ercan, Mujgan
Turhan, Turan
description As vitamin D has recently been implicated in various diseases, vitamin D testing has gained a lot more significance. Vitamin D deficiency is quite prevalent, and detection of this condition is important. Several manufacturers have developed new automated immunoassays for this purpose. In this study, we aimed to evaluate the analytical performance of the Access Total 25(OH) Vitamin D immunoassay on the Beckman Coulter Unicel DXI 800 analyzer, through comparison with the reference method, liquid chromatography/tandem mass spectrometry (LC-MS/MS).Methods The study was conducted with 148 patient samples which were sent to Ankara Numune Training and Research Hospital for routine vitamin D testing. Every sample was analyzed with both Unicel DXI 800 immunoassay analyzer and LC-MS/MS. The concordance of the results was evaluated with Passing-Bablok regression analysis and Bland-Altman plot. Additionally, imprecision, interference, limit of blank (LOB), recovery, linearity and carry-over studies were performed for the Beckman Coulter Unicel DXI 800 analyzer.Results When compared to LC-MS/MS, the Access Total 25(OH) Vitamin D immunoassay on the Beckman Coulter Unicel DXI 800 analyzer had an R-value of 0.957 (intercept: −3.938, slope: 1.185) and a mean bias of 9.5%. The concordance correlation coefficient (CCC) between the two methods was 0.916. The intra-assay, inter-assay and total coefficient of variation (CV%) for the Unicel DXI 800 vitamin D immunoassay were 3.3%, 5.3% and 8.3%, respectively, at 31.7 ng/mL concentration, and 2.1%, 3.2% and 7%, respectively, at 66.8 ng/mL concentration.Conclusions The Access Total 25(OH) Vitamin D immunoassay method has acceptable analytical performance, and the results are in concordance with the LC-MS/MS results.
doi_str_mv 10.1515/labmed-2018-0068
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2531871960</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2531871960</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-9828d6343470376d9d3cef46b48d26be4587e3e19d81dd5b0aeeda889b018fb03</originalsourceid><addsrcrecordid>eNp1kE1LxDAQhoMouK7ePQa86KE6-WibXoR1_VoQvKh4K2ky1a5tsyatuv_ellU8eZph5n0G5iHkkMEpi1l8VuuiQRtxYCoCSNQWmTApsghkmm6TCQjJIwE82SV7ISwBWJpxmJCvqw9d97qrXEtdSbtXpLrV9bqrjK7pCn3pfKNbg7_bCzRvw4DOXV936OljWxms6eXzgioAOjMGQ6APrhtwHh_f357Qp6rTTdXSS1o1Td86HYJe75OdUtcBD37qlDxeXz3Mb6O7-5vFfHYXGZGoLsoUVzYRUsgURJrYzAqDpUwKqSxPCpSxSlEgy6xi1sYFaESrlcqKQURZgJiSo83dlXfvPYYuX7reDy-GnMeCqZRlyZiCTcp4F4LHMl_5qtF-nTPIR7_5xm8--s1HvwNyvkE-9SjC4ovv10Pzd_8_VPKYQyy-ASt1grs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2531871960</pqid></control><display><type>article</type><title>Evaluation of the analytical performance of the Beckman Coulter Unicel DXI 800 Access Total 25(OH) Vitamin D immunoassay</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>Topçuoğlu, Canan ; Sezer, Sevilay ; Yılmaz, Fatma Meriç ; Kösem, Arzu ; Ercan, Mujgan ; Turhan, Turan</creator><creatorcontrib>Topçuoğlu, Canan ; Sezer, Sevilay ; Yılmaz, Fatma Meriç ; Kösem, Arzu ; Ercan, Mujgan ; Turhan, Turan</creatorcontrib><description>As vitamin D has recently been implicated in various diseases, vitamin D testing has gained a lot more significance. Vitamin D deficiency is quite prevalent, and detection of this condition is important. Several manufacturers have developed new automated immunoassays for this purpose. In this study, we aimed to evaluate the analytical performance of the Access Total 25(OH) Vitamin D immunoassay on the Beckman Coulter Unicel DXI 800 analyzer, through comparison with the reference method, liquid chromatography/tandem mass spectrometry (LC-MS/MS).Methods The study was conducted with 148 patient samples which were sent to Ankara Numune Training and Research Hospital for routine vitamin D testing. Every sample was analyzed with both Unicel DXI 800 immunoassay analyzer and LC-MS/MS. The concordance of the results was evaluated with Passing-Bablok regression analysis and Bland-Altman plot. Additionally, imprecision, interference, limit of blank (LOB), recovery, linearity and carry-over studies were performed for the Beckman Coulter Unicel DXI 800 analyzer.Results When compared to LC-MS/MS, the Access Total 25(OH) Vitamin D immunoassay on the Beckman Coulter Unicel DXI 800 analyzer had an R-value of 0.957 (intercept: −3.938, slope: 1.185) and a mean bias of 9.5%. The concordance correlation coefficient (CCC) between the two methods was 0.916. The intra-assay, inter-assay and total coefficient of variation (CV%) for the Unicel DXI 800 vitamin D immunoassay were 3.3%, 5.3% and 8.3%, respectively, at 31.7 ng/mL concentration, and 2.1%, 3.2% and 7%, respectively, at 66.8 ng/mL concentration.Conclusions The Access Total 25(OH) Vitamin D immunoassay method has acceptable analytical performance, and the results are in concordance with the LC-MS/MS results.</description><identifier>ISSN: 0342-3026</identifier><identifier>EISSN: 1439-0477</identifier><identifier>DOI: 10.1515/labmed-2018-0068</identifier><language>eng</language><publisher>Berlin: De Gruyter</publisher><subject>25(OH) vitamin D ; Calciferol ; Coefficient of variation ; Correlation coefficient ; Correlation coefficients ; Immunoassay ; Immunoassays ; Liquid chromatography ; liquid chromatography/tandem mass spectrometry (LC-MS/MS) ; Mass spectrometry ; Mass spectroscopy ; Mathematical analysis ; method comparison ; Performance evaluation ; Regression analysis ; Unicel DXI ; Vitamin D ; Vitamin deficiency</subject><ispartof>Laboratoriumsmedizin, 2018-10, Vol.42 (5), p.205-211</ispartof><rights>2018. This work is published under http://creativecommons.org/licenses/by-nc-nd/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-9828d6343470376d9d3cef46b48d26be4587e3e19d81dd5b0aeeda889b018fb03</citedby><cites>FETCH-LOGICAL-c368t-9828d6343470376d9d3cef46b48d26be4587e3e19d81dd5b0aeeda889b018fb03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Topçuoğlu, Canan</creatorcontrib><creatorcontrib>Sezer, Sevilay</creatorcontrib><creatorcontrib>Yılmaz, Fatma Meriç</creatorcontrib><creatorcontrib>Kösem, Arzu</creatorcontrib><creatorcontrib>Ercan, Mujgan</creatorcontrib><creatorcontrib>Turhan, Turan</creatorcontrib><title>Evaluation of the analytical performance of the Beckman Coulter Unicel DXI 800 Access Total 25(OH) Vitamin D immunoassay</title><title>Laboratoriumsmedizin</title><description>As vitamin D has recently been implicated in various diseases, vitamin D testing has gained a lot more significance. Vitamin D deficiency is quite prevalent, and detection of this condition is important. Several manufacturers have developed new automated immunoassays for this purpose. In this study, we aimed to evaluate the analytical performance of the Access Total 25(OH) Vitamin D immunoassay on the Beckman Coulter Unicel DXI 800 analyzer, through comparison with the reference method, liquid chromatography/tandem mass spectrometry (LC-MS/MS).Methods The study was conducted with 148 patient samples which were sent to Ankara Numune Training and Research Hospital for routine vitamin D testing. Every sample was analyzed with both Unicel DXI 800 immunoassay analyzer and LC-MS/MS. The concordance of the results was evaluated with Passing-Bablok regression analysis and Bland-Altman plot. Additionally, imprecision, interference, limit of blank (LOB), recovery, linearity and carry-over studies were performed for the Beckman Coulter Unicel DXI 800 analyzer.Results When compared to LC-MS/MS, the Access Total 25(OH) Vitamin D immunoassay on the Beckman Coulter Unicel DXI 800 analyzer had an R-value of 0.957 (intercept: −3.938, slope: 1.185) and a mean bias of 9.5%. The concordance correlation coefficient (CCC) between the two methods was 0.916. The intra-assay, inter-assay and total coefficient of variation (CV%) for the Unicel DXI 800 vitamin D immunoassay were 3.3%, 5.3% and 8.3%, respectively, at 31.7 ng/mL concentration, and 2.1%, 3.2% and 7%, respectively, at 66.8 ng/mL concentration.Conclusions The Access Total 25(OH) Vitamin D immunoassay method has acceptable analytical performance, and the results are in concordance with the LC-MS/MS results.</description><subject>25(OH) vitamin D</subject><subject>Calciferol</subject><subject>Coefficient of variation</subject><subject>Correlation coefficient</subject><subject>Correlation coefficients</subject><subject>Immunoassay</subject><subject>Immunoassays</subject><subject>Liquid chromatography</subject><subject>liquid chromatography/tandem mass spectrometry (LC-MS/MS)</subject><subject>Mass spectrometry</subject><subject>Mass spectroscopy</subject><subject>Mathematical analysis</subject><subject>method comparison</subject><subject>Performance evaluation</subject><subject>Regression analysis</subject><subject>Unicel DXI</subject><subject>Vitamin D</subject><subject>Vitamin deficiency</subject><issn>0342-3026</issn><issn>1439-0477</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp1kE1LxDAQhoMouK7ePQa86KE6-WibXoR1_VoQvKh4K2ky1a5tsyatuv_ellU8eZph5n0G5iHkkMEpi1l8VuuiQRtxYCoCSNQWmTApsghkmm6TCQjJIwE82SV7ISwBWJpxmJCvqw9d97qrXEtdSbtXpLrV9bqrjK7pCn3pfKNbg7_bCzRvw4DOXV936OljWxms6eXzgioAOjMGQ6APrhtwHh_f357Qp6rTTdXSS1o1Td86HYJe75OdUtcBD37qlDxeXz3Mb6O7-5vFfHYXGZGoLsoUVzYRUsgURJrYzAqDpUwKqSxPCpSxSlEgy6xi1sYFaESrlcqKQURZgJiSo83dlXfvPYYuX7reDy-GnMeCqZRlyZiCTcp4F4LHMl_5qtF-nTPIR7_5xm8--s1HvwNyvkE-9SjC4ovv10Pzd_8_VPKYQyy-ASt1grs</recordid><startdate>20181025</startdate><enddate>20181025</enddate><creator>Topçuoğlu, Canan</creator><creator>Sezer, Sevilay</creator><creator>Yılmaz, Fatma Meriç</creator><creator>Kösem, Arzu</creator><creator>Ercan, Mujgan</creator><creator>Turhan, Turan</creator><general>De Gruyter</general><general>Walter de Gruyter GmbH</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QL</scope><scope>7QO</scope><scope>7T7</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>P64</scope><scope>RC3</scope></search><sort><creationdate>20181025</creationdate><title>Evaluation of the analytical performance of the Beckman Coulter Unicel DXI 800 Access Total 25(OH) Vitamin D immunoassay</title><author>Topçuoğlu, Canan ; Sezer, Sevilay ; Yılmaz, Fatma Meriç ; Kösem, Arzu ; Ercan, Mujgan ; Turhan, Turan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-9828d6343470376d9d3cef46b48d26be4587e3e19d81dd5b0aeeda889b018fb03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>25(OH) vitamin D</topic><topic>Calciferol</topic><topic>Coefficient of variation</topic><topic>Correlation coefficient</topic><topic>Correlation coefficients</topic><topic>Immunoassay</topic><topic>Immunoassays</topic><topic>Liquid chromatography</topic><topic>liquid chromatography/tandem mass spectrometry (LC-MS/MS)</topic><topic>Mass spectrometry</topic><topic>Mass spectroscopy</topic><topic>Mathematical analysis</topic><topic>method comparison</topic><topic>Performance evaluation</topic><topic>Regression analysis</topic><topic>Unicel DXI</topic><topic>Vitamin D</topic><topic>Vitamin deficiency</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Topçuoğlu, Canan</creatorcontrib><creatorcontrib>Sezer, Sevilay</creatorcontrib><creatorcontrib>Yılmaz, Fatma Meriç</creatorcontrib><creatorcontrib>Kösem, Arzu</creatorcontrib><creatorcontrib>Ercan, Mujgan</creatorcontrib><creatorcontrib>Turhan, Turan</creatorcontrib><collection>CrossRef</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Biotechnology Research Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Genetics Abstracts</collection><jtitle>Laboratoriumsmedizin</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Topçuoğlu, Canan</au><au>Sezer, Sevilay</au><au>Yılmaz, Fatma Meriç</au><au>Kösem, Arzu</au><au>Ercan, Mujgan</au><au>Turhan, Turan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of the analytical performance of the Beckman Coulter Unicel DXI 800 Access Total 25(OH) Vitamin D immunoassay</atitle><jtitle>Laboratoriumsmedizin</jtitle><date>2018-10-25</date><risdate>2018</risdate><volume>42</volume><issue>5</issue><spage>205</spage><epage>211</epage><pages>205-211</pages><issn>0342-3026</issn><eissn>1439-0477</eissn><abstract>As vitamin D has recently been implicated in various diseases, vitamin D testing has gained a lot more significance. Vitamin D deficiency is quite prevalent, and detection of this condition is important. Several manufacturers have developed new automated immunoassays for this purpose. In this study, we aimed to evaluate the analytical performance of the Access Total 25(OH) Vitamin D immunoassay on the Beckman Coulter Unicel DXI 800 analyzer, through comparison with the reference method, liquid chromatography/tandem mass spectrometry (LC-MS/MS).Methods The study was conducted with 148 patient samples which were sent to Ankara Numune Training and Research Hospital for routine vitamin D testing. Every sample was analyzed with both Unicel DXI 800 immunoassay analyzer and LC-MS/MS. The concordance of the results was evaluated with Passing-Bablok regression analysis and Bland-Altman plot. Additionally, imprecision, interference, limit of blank (LOB), recovery, linearity and carry-over studies were performed for the Beckman Coulter Unicel DXI 800 analyzer.Results When compared to LC-MS/MS, the Access Total 25(OH) Vitamin D immunoassay on the Beckman Coulter Unicel DXI 800 analyzer had an R-value of 0.957 (intercept: −3.938, slope: 1.185) and a mean bias of 9.5%. The concordance correlation coefficient (CCC) between the two methods was 0.916. The intra-assay, inter-assay and total coefficient of variation (CV%) for the Unicel DXI 800 vitamin D immunoassay were 3.3%, 5.3% and 8.3%, respectively, at 31.7 ng/mL concentration, and 2.1%, 3.2% and 7%, respectively, at 66.8 ng/mL concentration.Conclusions The Access Total 25(OH) Vitamin D immunoassay method has acceptable analytical performance, and the results are in concordance with the LC-MS/MS results.</abstract><cop>Berlin</cop><pub>De Gruyter</pub><doi>10.1515/labmed-2018-0068</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0342-3026
ispartof Laboratoriumsmedizin, 2018-10, Vol.42 (5), p.205-211
issn 0342-3026
1439-0477
language eng
recordid cdi_proquest_journals_2531871960
source EZB-FREE-00999 freely available EZB journals
subjects 25(OH) vitamin D
Calciferol
Coefficient of variation
Correlation coefficient
Correlation coefficients
Immunoassay
Immunoassays
Liquid chromatography
liquid chromatography/tandem mass spectrometry (LC-MS/MS)
Mass spectrometry
Mass spectroscopy
Mathematical analysis
method comparison
Performance evaluation
Regression analysis
Unicel DXI
Vitamin D
Vitamin deficiency
title Evaluation of the analytical performance of the Beckman Coulter Unicel DXI 800 Access Total 25(OH) Vitamin D immunoassay
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T07%3A37%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20the%20analytical%20performance%20of%20the%20Beckman%20Coulter%20Unicel%20DXI%20800%20Access%20Total%2025(OH)%20Vitamin%20D%20immunoassay&rft.jtitle=Laboratoriumsmedizin&rft.au=Top%C3%A7uo%C4%9Flu,%20Canan&rft.date=2018-10-25&rft.volume=42&rft.issue=5&rft.spage=205&rft.epage=211&rft.pages=205-211&rft.issn=0342-3026&rft.eissn=1439-0477&rft_id=info:doi/10.1515/labmed-2018-0068&rft_dat=%3Cproquest_cross%3E2531871960%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2531871960&rft_id=info:pmid/&rfr_iscdi=true