Multi-scale analysis of the under-ventilated combustion regime for the case of a fire event in a confined and mechanically ventilated compartment
This work deals with under-ventilated pool fires in confined and mechanically ventilated enclosures. The objective is to demonstrate the suitability of reduced-scale experiments to investigate under-ventilated combustion regimes in the case of a mechanically ventilated enclosure, by analysing combus...
Gespeichert in:
Veröffentlicht in: | Fire safety journal 2021-03, Vol.120, p.103069, Article 103069 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | 103069 |
container_title | Fire safety journal |
container_volume | 120 |
creator | Prétrel, Hugues Bouaza, Lafdal Suard, Sylvain |
description | This work deals with under-ventilated pool fires in confined and mechanically ventilated enclosures. The objective is to demonstrate the suitability of reduced-scale experiments to investigate under-ventilated combustion regimes in the case of a mechanically ventilated enclosure, by analysing combustion regimes at two different scales. The fire scenario consists in a dodecane liquid pool fire located in a mechanically ventilated room. Reduced-scale experiments concern a 0.031 m2 pool size inside a 1.875 m3 enclosure and large-scale experiments concern a 0.4 m2 pool size inside a 120 m3 enclosure. The varying parameter is the ventilation flow rate, which allows the fire behaviour to be investigated, from free-burning to confined situations. At both scales, results show that the burning rate decreases with the ventilation flow rate and a linear relationship between oxygen concentration and fuel mass loss rate is revealed. Comparison between the well-stirred reactor model and the experimental results shows good agreement for both scales. The work demonstrates the suitability of the reduced-scale approach to reproduce the combustion process in a vitiated environment, provided that appropriate dimensionless parameters are used: a reduced heat-release rate, a thermal ratio parameter and the global equivalence ratio.
•Multi-scale analysis of pool fires in a mechanically ventilated enclosure.•Reduced and large-scale experiments.•Identification of main scaling parameters.•Identification of the burning rate regime in a vitiated environment. |
doi_str_mv | 10.1016/j.firesaf.2020.103069 |
format | Article |
fullrecord | <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_proquest_journals_2524410981</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0379711220300527</els_id><sourcerecordid>2524410981</sourcerecordid><originalsourceid>FETCH-LOGICAL-c418t-e4a93fd6afbcd31ef8351121cbec7fd43088e9414c72d26bbfbffd308b90d33b3</originalsourceid><addsrcrecordid>eNqFkc1qGzEUhUVpoK6TRygIsupiHP2M52dVjEnigEs3zVpopKtaZkZyJI3Bj9E3rqZjCll1JXT4ztG9Ogh9oWRFCa0ejitjA0RpVoywSeOkaj-gBW1qXtSMVR_RgvC6LWpK2Sf0OcYjIbQmpF2g39_HPtkiKtkDlk72l2gj9ganA-DRaQjFGVyyvUygsfJDN8ZkvcMBftkBsPHhL6pkhMkm8TQLhsmErct35Z2xLpul03gAdZDO5tf6C34ffJIhDVm5RTdG9hHurucSvT49_tzuiv2P55ftZl-okjapgFK23OhKmk5pTsE0fJ3Xo6oDVRtdctI00Ja0VDXTrOo60xmjs9q1RHPe8SX6OuceZC9OwQ4yXISXVuw2ezFphPOasIqcaWbvZ_YU_NsIMYmjH0P-rSjYmpUlJW0zUeuZUsHHGMD8i6VETE2Jo7g2JaamxNxU9n2bfZDXPVsIIioLToHOsEpCe_ufhD9X_6Fq</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2524410981</pqid></control><display><type>article</type><title>Multi-scale analysis of the under-ventilated combustion regime for the case of a fire event in a confined and mechanically ventilated compartment</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Prétrel, Hugues ; Bouaza, Lafdal ; Suard, Sylvain</creator><creatorcontrib>Prétrel, Hugues ; Bouaza, Lafdal ; Suard, Sylvain</creatorcontrib><description>This work deals with under-ventilated pool fires in confined and mechanically ventilated enclosures. The objective is to demonstrate the suitability of reduced-scale experiments to investigate under-ventilated combustion regimes in the case of a mechanically ventilated enclosure, by analysing combustion regimes at two different scales. The fire scenario consists in a dodecane liquid pool fire located in a mechanically ventilated room. Reduced-scale experiments concern a 0.031 m2 pool size inside a 1.875 m3 enclosure and large-scale experiments concern a 0.4 m2 pool size inside a 120 m3 enclosure. The varying parameter is the ventilation flow rate, which allows the fire behaviour to be investigated, from free-burning to confined situations. At both scales, results show that the burning rate decreases with the ventilation flow rate and a linear relationship between oxygen concentration and fuel mass loss rate is revealed. Comparison between the well-stirred reactor model and the experimental results shows good agreement for both scales. The work demonstrates the suitability of the reduced-scale approach to reproduce the combustion process in a vitiated environment, provided that appropriate dimensionless parameters are used: a reduced heat-release rate, a thermal ratio parameter and the global equivalence ratio.
•Multi-scale analysis of pool fires in a mechanically ventilated enclosure.•Reduced and large-scale experiments.•Identification of main scaling parameters.•Identification of the burning rate regime in a vitiated environment.</description><identifier>ISSN: 0379-7112</identifier><identifier>EISSN: 1873-7226</identifier><identifier>DOI: 10.1016/j.firesaf.2020.103069</identifier><language>eng</language><publisher>Lausanne: Elsevier Ltd</publisher><subject>Burning ; Burning rate ; Combustion ; Compartment fires ; Dodecane ; Enclosures ; Engineering Sciences ; Equivalence ratio ; Experiments ; Flow rates ; Flow velocity ; Multiscale analysis ; Nuclear fuels ; Parameters ; Pool fire ; Pool fires ; Scale modelling parameters ; Under-ventilated burning ; Ventilation</subject><ispartof>Fire safety journal, 2021-03, Vol.120, p.103069, Article 103069</ispartof><rights>2020 Elsevier Ltd</rights><rights>Copyright Elsevier BV Mar 2021</rights><rights>Attribution - NonCommercial - NoDerivatives</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c418t-e4a93fd6afbcd31ef8351121cbec7fd43088e9414c72d26bbfbffd308b90d33b3</citedby><cites>FETCH-LOGICAL-c418t-e4a93fd6afbcd31ef8351121cbec7fd43088e9414c72d26bbfbffd308b90d33b3</cites><orcidid>0000-0002-7669-3902 ; 0000-0003-3044-5695 ; 0000-0002-6906-0744</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.firesaf.2020.103069$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,309,314,780,784,885,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://hal.science/hal-03370260$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Prétrel, Hugues</creatorcontrib><creatorcontrib>Bouaza, Lafdal</creatorcontrib><creatorcontrib>Suard, Sylvain</creatorcontrib><title>Multi-scale analysis of the under-ventilated combustion regime for the case of a fire event in a confined and mechanically ventilated compartment</title><title>Fire safety journal</title><description>This work deals with under-ventilated pool fires in confined and mechanically ventilated enclosures. The objective is to demonstrate the suitability of reduced-scale experiments to investigate under-ventilated combustion regimes in the case of a mechanically ventilated enclosure, by analysing combustion regimes at two different scales. The fire scenario consists in a dodecane liquid pool fire located in a mechanically ventilated room. Reduced-scale experiments concern a 0.031 m2 pool size inside a 1.875 m3 enclosure and large-scale experiments concern a 0.4 m2 pool size inside a 120 m3 enclosure. The varying parameter is the ventilation flow rate, which allows the fire behaviour to be investigated, from free-burning to confined situations. At both scales, results show that the burning rate decreases with the ventilation flow rate and a linear relationship between oxygen concentration and fuel mass loss rate is revealed. Comparison between the well-stirred reactor model and the experimental results shows good agreement for both scales. The work demonstrates the suitability of the reduced-scale approach to reproduce the combustion process in a vitiated environment, provided that appropriate dimensionless parameters are used: a reduced heat-release rate, a thermal ratio parameter and the global equivalence ratio.
•Multi-scale analysis of pool fires in a mechanically ventilated enclosure.•Reduced and large-scale experiments.•Identification of main scaling parameters.•Identification of the burning rate regime in a vitiated environment.</description><subject>Burning</subject><subject>Burning rate</subject><subject>Combustion</subject><subject>Compartment fires</subject><subject>Dodecane</subject><subject>Enclosures</subject><subject>Engineering Sciences</subject><subject>Equivalence ratio</subject><subject>Experiments</subject><subject>Flow rates</subject><subject>Flow velocity</subject><subject>Multiscale analysis</subject><subject>Nuclear fuels</subject><subject>Parameters</subject><subject>Pool fire</subject><subject>Pool fires</subject><subject>Scale modelling parameters</subject><subject>Under-ventilated burning</subject><subject>Ventilation</subject><issn>0379-7112</issn><issn>1873-7226</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNqFkc1qGzEUhUVpoK6TRygIsupiHP2M52dVjEnigEs3zVpopKtaZkZyJI3Bj9E3rqZjCll1JXT4ztG9Ogh9oWRFCa0ejitjA0RpVoywSeOkaj-gBW1qXtSMVR_RgvC6LWpK2Sf0OcYjIbQmpF2g39_HPtkiKtkDlk72l2gj9ganA-DRaQjFGVyyvUygsfJDN8ZkvcMBftkBsPHhL6pkhMkm8TQLhsmErct35Z2xLpul03gAdZDO5tf6C34ffJIhDVm5RTdG9hHurucSvT49_tzuiv2P55ftZl-okjapgFK23OhKmk5pTsE0fJ3Xo6oDVRtdctI00Ja0VDXTrOo60xmjs9q1RHPe8SX6OuceZC9OwQ4yXISXVuw2ezFphPOasIqcaWbvZ_YU_NsIMYmjH0P-rSjYmpUlJW0zUeuZUsHHGMD8i6VETE2Jo7g2JaamxNxU9n2bfZDXPVsIIioLToHOsEpCe_ufhD9X_6Fq</recordid><startdate>202103</startdate><enddate>202103</enddate><creator>Prétrel, Hugues</creator><creator>Bouaza, Lafdal</creator><creator>Suard, Sylvain</creator><general>Elsevier Ltd</general><general>Elsevier BV</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7T2</scope><scope>7TB</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>KR7</scope><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0002-7669-3902</orcidid><orcidid>https://orcid.org/0000-0003-3044-5695</orcidid><orcidid>https://orcid.org/0000-0002-6906-0744</orcidid></search><sort><creationdate>202103</creationdate><title>Multi-scale analysis of the under-ventilated combustion regime for the case of a fire event in a confined and mechanically ventilated compartment</title><author>Prétrel, Hugues ; Bouaza, Lafdal ; Suard, Sylvain</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c418t-e4a93fd6afbcd31ef8351121cbec7fd43088e9414c72d26bbfbffd308b90d33b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Burning</topic><topic>Burning rate</topic><topic>Combustion</topic><topic>Compartment fires</topic><topic>Dodecane</topic><topic>Enclosures</topic><topic>Engineering Sciences</topic><topic>Equivalence ratio</topic><topic>Experiments</topic><topic>Flow rates</topic><topic>Flow velocity</topic><topic>Multiscale analysis</topic><topic>Nuclear fuels</topic><topic>Parameters</topic><topic>Pool fire</topic><topic>Pool fires</topic><topic>Scale modelling parameters</topic><topic>Under-ventilated burning</topic><topic>Ventilation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Prétrel, Hugues</creatorcontrib><creatorcontrib>Bouaza, Lafdal</creatorcontrib><creatorcontrib>Suard, Sylvain</creatorcontrib><collection>CrossRef</collection><collection>Health and Safety Science Abstracts (Full archive)</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Fire safety journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Prétrel, Hugues</au><au>Bouaza, Lafdal</au><au>Suard, Sylvain</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Multi-scale analysis of the under-ventilated combustion regime for the case of a fire event in a confined and mechanically ventilated compartment</atitle><jtitle>Fire safety journal</jtitle><date>2021-03</date><risdate>2021</risdate><volume>120</volume><spage>103069</spage><pages>103069-</pages><artnum>103069</artnum><issn>0379-7112</issn><eissn>1873-7226</eissn><abstract>This work deals with under-ventilated pool fires in confined and mechanically ventilated enclosures. The objective is to demonstrate the suitability of reduced-scale experiments to investigate under-ventilated combustion regimes in the case of a mechanically ventilated enclosure, by analysing combustion regimes at two different scales. The fire scenario consists in a dodecane liquid pool fire located in a mechanically ventilated room. Reduced-scale experiments concern a 0.031 m2 pool size inside a 1.875 m3 enclosure and large-scale experiments concern a 0.4 m2 pool size inside a 120 m3 enclosure. The varying parameter is the ventilation flow rate, which allows the fire behaviour to be investigated, from free-burning to confined situations. At both scales, results show that the burning rate decreases with the ventilation flow rate and a linear relationship between oxygen concentration and fuel mass loss rate is revealed. Comparison between the well-stirred reactor model and the experimental results shows good agreement for both scales. The work demonstrates the suitability of the reduced-scale approach to reproduce the combustion process in a vitiated environment, provided that appropriate dimensionless parameters are used: a reduced heat-release rate, a thermal ratio parameter and the global equivalence ratio.
•Multi-scale analysis of pool fires in a mechanically ventilated enclosure.•Reduced and large-scale experiments.•Identification of main scaling parameters.•Identification of the burning rate regime in a vitiated environment.</abstract><cop>Lausanne</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.firesaf.2020.103069</doi><orcidid>https://orcid.org/0000-0002-7669-3902</orcidid><orcidid>https://orcid.org/0000-0003-3044-5695</orcidid><orcidid>https://orcid.org/0000-0002-6906-0744</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0379-7112 |
ispartof | Fire safety journal, 2021-03, Vol.120, p.103069, Article 103069 |
issn | 0379-7112 1873-7226 |
language | eng |
recordid | cdi_proquest_journals_2524410981 |
source | ScienceDirect Journals (5 years ago - present) |
subjects | Burning Burning rate Combustion Compartment fires Dodecane Enclosures Engineering Sciences Equivalence ratio Experiments Flow rates Flow velocity Multiscale analysis Nuclear fuels Parameters Pool fire Pool fires Scale modelling parameters Under-ventilated burning Ventilation |
title | Multi-scale analysis of the under-ventilated combustion regime for the case of a fire event in a confined and mechanically ventilated compartment |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T20%3A38%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Multi-scale%20analysis%20of%20the%20under-ventilated%20combustion%20regime%20for%20the%20case%20of%20a%20fire%20event%20in%20a%20confined%20and%20mechanically%20ventilated%20compartment&rft.jtitle=Fire%20safety%20journal&rft.au=Pr%C3%A9trel,%20Hugues&rft.date=2021-03&rft.volume=120&rft.spage=103069&rft.pages=103069-&rft.artnum=103069&rft.issn=0379-7112&rft.eissn=1873-7226&rft_id=info:doi/10.1016/j.firesaf.2020.103069&rft_dat=%3Cproquest_hal_p%3E2524410981%3C/proquest_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2524410981&rft_id=info:pmid/&rft_els_id=S0379711220300527&rfr_iscdi=true |